電(dian)(dian)(dian)(dian)(dian)力設(she)備(bei)的(de)(de)接(jie)(jie)地(di)(di)引下線與地(di)(di)網(wang)的(de)(de)可(ke)靠、有效連接(jie)(jie)是設(she)備(bei)**運(yun)行的(de)(de)根(gen)(gen)本保障(zhang)。接(jie)(jie)地(di)(di)引下線是電(dian)(dian)(dian)(dian)(dian)力設(she)備(bei)與地(di)(di)網(wang)的(de)(de)連接(jie)(jie)部分,在電(dian)(dian)(dian)(dian)(dian)力設(she)備(bei)的(de)(de)長時(shi)間運(yun)行過程(cheng)中(zhong),連接(jie)(jie)處(chu)(chu)有可(ke)能(neng)因(yin)受潮等(deng)因(yin)素影響,出現(xian)節(jie)點銹蝕、甚至斷(duan)裂等(deng)現(xian)象,導(dao)致(zhi)接(jie)(jie)地(di)(di)引下線與主接(jie)(jie)地(di)(di)網(wang)連接(jie)(jie)點電(dian)(dian)(dian)(dian)(dian)阻增(zeng)大(da),從而(er)不(bu)能(neng)滿足電(dian)(dian)(dian)(dian)(dian)力規程(cheng)的(de)(de)要求,使(shi)設(she)備(bei)在運(yun)行中(zhong)存在不(bu)**隱患,嚴(yan)重時(shi)會(hui)造成(cheng)(cheng)設(she)備(bei)失地(di)(di)運(yun)行。我(wo)公司利用自身技術(shu)優勢研制了系列接(jie)(jie)地(di)(di)引下線導(dao)通測(ce)試儀(yi)(yi)(yi)。該(gai)儀(yi)(yi)(yi)器采用全新電(dian)(dian)(dian)(dian)(dian)源(yuan)技術(shu),具有體(ti)積小、重量輕、輸出電(dian)(dian)(dian)(dian)(dian)流大(da)并且可(ke)根(gen)(gen)據(ju)負載大(da)小自動(dong)(dong)調整等(deng)特點。整機由單片機控制,自動(dong)(dong)完成(cheng)(cheng)自檢、數據(ju)處(chu)(chu)理、顯示(shi)、打印等(deng)功(gong)能(neng),具有自動(dong)(dong)放(fang)(fang)電(dian)(dian)(dian)(dian)(dian)和放(fang)(fang)電(dian)(dian)(dian)(dian)(dian)指示(shi)功(gong)能(neng)。儀(yi)(yi)(yi)器測(ce)試精(jing)度高(gao),操(cao)作(zuo)簡(jian)便,可(ke)實(shi)現(xian)接(jie)(jie)地(di)(di)電(dian)(dian)(dian)(dian)(dian)阻的(de)(de)快(kuai)速測(ce)量。
一(yi)、WBDT-V接地引(yin)下線(xian)導通電阻分(fen)析儀**措施(shi)
使用本儀器(qi)前(qian)一(yi)定要認真(zhen)閱(yue)讀本手(shou)冊。
儀器(qi)的操作者應具(ju)備(bei)一(yi)般(ban)電氣設(she)備(bei)或儀器(qi)的使(shi)用常識。
本儀器戶內外均可使用(yong),但應避開雨淋、腐蝕氣體、塵埃過(guo)濃、高溫(wen)、陽光直射(she)等場(chang)所(suo)。
儀(yi)表應避(bi)免劇烈振動。
對儀器的(de)維修、護理和調整應由專業人員進行。
測(ce)試(shi)完畢后(hou)一定要等(deng)放電報警聲停止后(hou)再關閉電源,拆除測(ce)試(shi)線。
在測試(shi)(shi)過程中,禁止移動測試(shi)(shi)夾和供電(dian)線路。
二、WBDT-V接地(di)引下線導通電阻分析儀(yi)性能(neng)特(te)點
儀(yi)器(qi)輸出電流(liu)大(da),測量范圍寬,操作簡便;
儀器具(ju)有完善的反電(dian)勢(shi)保護功(gong)能,音響放電(dian)報警,放電(dian)指示清(qing)晰(xi),減少誤操作;
儀器裝有打(da)印(yin)(yin)機(ji),可隨(sui)時打(da)印(yin)(yin)測試(shi)數據;
儀器具有實時時鐘,并(bing)可連同測(ce)試記錄(lu)一起保(bao)存(cun)、打印,方便用戶保(bao)存(cun)、查(cha)閱;
儀器內部(bu)可以長久存儲測試數(shu)據200條(可擴展),還(huan)可以使用優盤存儲(chu)數據方便(bian)用戶導入電(dian)腦處理。
儀器具有適用溫度寬,精度高(gao),防震,抗干擾(rao),體積小,重量輕,攜帶(dai)方便(bian)等特點。
三(san)、WBDT-V接(jie)地引下線導通電(dian)阻分析儀(yi)技術指(zhi)標
測試(shi)電流:0.2A、1A、5A、10A四檔
測試范(fan)圍:0.2 A 10 Ω ~ 100Ω
1 A 100mΩ
~ 20 Ω
5 A 10 mΩ
~ 4 Ω
10 A 1 mΩ ~ 2 Ω
準確(que)度:±(讀數(shu)×0.2%+2字)
*高分辨率: 0.1μΩ
工作溫度:-5~40℃;環境濕度:≤90%RH,無結露
工(gong)作電(dian)源:AC220V±10%,50HZ±1HZ
體積:390×280×200mm
重量:7Kg(不包括(kuo)測試線)
四、WBDT-V接地引下線導通電阻分析儀面(mian)板功(gong)能介(jie)紹
儀器面(mian)板(ban)見圖一。
電源開關(guan):整機電源輸入(ru)口,帶(dai)有(you)交(jiao)流(liu)插座,保險(xian)倉和開關(guan)。
: 接(jie)地柱(zhu),為整機外殼(ke)接(jie)地用(yong),屬保護地。
V+、V-: 電壓輸(shu)入端子。
I+、I-: 電流輸出端子。
顯示器: 128×64點(dian)陣液晶顯示器(qi),人機交互界面。
打印機: 打印輸出直流電阻測試結果。
USB: 優(you)盤接(jie)口
RS232: 儀器與計算機連(lian)接的通訊接口(kou)
返回鍵: 返(fan)回上級菜單(dan)界面或取消當前操作。
選擇(ze)鍵: 在儀器操作過程中移動光標(biao)。
確(que)認鍵(jian): 修改參數或(huo)執行所(suo)選操作。
五、WBDT-V接地(di)引下線導通(tong)電阻分析儀使用說明
1、儀器開機顯示畫面
打開(kai)電源開(kai)關(guan)(開(kai)關(guan)上I為開(kai),O為關(guan)),儀器顯示(shi)區將(jiang)顯示(shi)圖(tu)三(san)界面。
2、時鐘(zhong)界面
放電(dian)檢(jian)測完畢后,儀器自動進入時鐘界面。
此界(jie)面(mian)實(shi)(shi)時(shi)(shi)(shi)顯(xian)示系統(tong)時(shi)(shi)(shi)鐘(zhong)(zhong),用戶可(ke)按“確認(ren)(ren)(ren)(ren)”鍵(jian)(jian)(jian)直接(jie)進(jin)入主(zhu)菜(cai)單界(jie)面(mian)。如用戶想(xiang)修改時(shi)(shi)(shi)鐘(zhong)(zhong),可(ke)按選(xuan)擇鍵(jian)(jian)(jian)移動(dong)光標(字體反白(bai)顯(xian)示為(wei)光標選(xuan)中狀態(tai)),此時(shi)(shi)(shi)按“確認(ren)(ren)(ren)(ren)”鍵(jian)(jian)(jian)可(ke)實(shi)(shi)現數值加一功(gong)能,當光標移動(dong)到“確定”按鈕(niu)時(shi)(shi)(shi),按“確認(ren)(ren)(ren)(ren)”鍵(jian)(jian)(jian)即可(ke)設定時(shi)(shi)(shi)鐘(zhong)(zhong)并進(jin)入主(zhu)菜(cai)單界(jie)面(mian),如中途(tu)用戶不想(xiang)修改時(shi)(shi)(shi)鐘(zhong)(zhong)了(le),可(ke)按“返回”鍵(jian)(jian)(jian)推(tui)出(chu)設定界(jie)面(mian),儀器仍將實(shi)(shi)時(shi)(shi)(shi)刷(shua)新時(shi)(shi)(shi)鐘(zhong)(zhong),再(zai)按“確認(ren)(ren)(ren)(ren)”鍵(jian)(jian)(jian)即可(ke)進(jin)入主(zhu)菜(cai)單界(jie)面(mian)。
3、主菜單界(jie)面(mian)
按(an)“選擇(ze)”鍵移動光(guang)標,按(an)“確認”鍵進(jin)入所選菜(cai)單,按(an)“返(fan)回”鍵回到上(shang)一頁。
3.1導通測試菜(cai)單
按(an)“選(xuan)擇(ze)(ze)”移(yi)動光標,當光標選(xuan)中“電流選(xuan)擇(ze)(ze):xxxA”時,按(an)“確認”可修改(gai)電流值(0.2A→1A→5A→10A→0.2A循環顯示);當(dang)光(guang)標移(yi)動到“確定”按(an)鈕時,按(an)確認鍵(jian)即可(ke)按(an)當(dang)前選定的測試電流進行測試,進入(ru)圖七→圖八→圖九界面(mian)。
當進度條到達右端(duan),表示測試(shi)完畢,將顯示測試(shi)結(jie)果如(ru)圖十(shi)
此時界面顯示的電阻值為實時測(ce)量值,用戶可(ke)按(an)“選擇(ze)”鍵(jian)選擇(ze)“保存”或是(shi)“打印(yin)”,按(an)“確認”鍵(jian)執(zhi)行所(suo)選操作,按(an)“返回”鍵(jian)儀器停止測(ce)試并開始放電如圖十一
放電完畢后,儀器(qi)將返(fan)回到圖(tu)六界(jie)面。
當在圖(tu)十界面中用戶(hu)選擇保存時,儀器將(jiang)提示用戶(hu)選擇存儲介(jie)質如圖(tu)十二(er)
按(an)“選擇”鍵移(yi)動光標,按(an)“確認(ren)”鍵保存(cun)到(dao)相(xiang)應存(cun)儲介質并返回(hui)到(dao)圖十界面,實時刷新(xin)測量結果,也可不保存(cun)按(an)“返回(hui)”回(hui)到(dao)圖十界面,實時刷新(xin)測量結果。
注:整個測(ce)試過程中切(qie)勿(wu)拆線,待放電完畢方可拆線。
3.2、數據存取菜(cai)單(dan)
按(an)“選(xuan)擇”鍵(jian)移動光標,按(an)“確(que)認”鍵(jian)執行所(suo)選(xuan)操作,按(an)“返回”鍵(jian)回到主菜單。
六(liu)、注意(yi)事項
測(ce)(ce)試過程中嚴(yan)禁拆除測(ce)(ce)試下(xia)和切斷系(xi)統電源。
在拆線前,一定要等放電結(jie)束后,報警聲停止,再進行拆線。
如果測(ce)試線沒(mei)接(jie)好,儀器會自動提示“電源開路”。這時須(xu)檢查線路是否有正確(que)或(huo)沒(mei)接(jie)牢(lao)固,然(ran)后(hou)按(an)復位(wei)鍵重(zhong)新測(ce)量。
七、售后服務
1、凡購(gou)本公司(si)產(chan)品(pin)(pin)隨機攜帶產(chan)品(pin)(pin)保(bao)修(xiu)單(dan),訂購(gou)產(chan)品(pin)(pin)交貨時,請當場檢驗并填好保(bao)修(xiu)單(dan)。
2、自購機之日起,憑保修(xiu)(xiu)(xiu)單保修(xiu)(xiu)(xiu)二年,終身(shen)維(wei)護。在(zai)保修(xiu)(xiu)(xiu)期內,維(wei)修(xiu)(xiu)(xiu)不收維(wei)修(xiu)(xiu)(xiu)費(fei);保修(xiu)(xiu)(xiu)期外,維(wei)修(xiu)(xiu)(xiu)調(diao)試收取(qu)適當費(fei)用。
3、屬下列情況之一者不予(yu)保修(xiu):
1)用戶對儀(yi)器有自行拆卸或對儀(yi)器工藝結構有人為改變。
2)因用(yong)戶保管或使用(yong)不當造成儀(yi)器的嚴重(zhong)損壞。
3)屬(shu)于用戶其它原因(yin)造成(cheng)的損壞(huai)。
裝箱單
儀器名稱:接(jie)地引下線(xian)導通測(ce)試儀
測試儀主機(ji)
|
一(yi)臺
|
測試(shi)線
|
二(er)條(tiao)(紅黑)
|
三芯(xin)電源線
|
一(yi)條
|
接地(di)線
|
一(yi)條
|
保險管(3A)
|
三(san)支
|
打印紙
|
二(er)卷
|
測試報告
|
一份
|
裝箱(xiang)單
|
一(yi)張
|
使(shi)用說明(ming)書(shu)
|
一本(ben)
|
合(he)格證(zheng) 保修卡(ka)
|
一張
|