電(dian)力(li)設(she)備(bei)(bei)的(de)(de)接(jie)(jie)地(di)引下(xia)線與地(di)網(wang)的(de)(de)可(ke)(ke)靠(kao)、有效(xiao)連(lian)(lian)接(jie)(jie)是設(she)備(bei)(bei)**運行(xing)的(de)(de)根本保障。接(jie)(jie)地(di)引下(xia)線是電(dian)力(li)設(she)備(bei)(bei)與地(di)網(wang)的(de)(de)連(lian)(lian)接(jie)(jie)部分,在電(dian)力(li)設(she)備(bei)(bei)的(de)(de)長時(shi)間運行(xing)過(guo)程(cheng)中,連(lian)(lian)接(jie)(jie)處有可(ke)(ke)能(neng)因受潮等(deng)因素影(ying)響,出現(xian)節點(dian)銹蝕、甚至斷(duan)裂(lie)等(deng)現(xian)象,導(dao)致(zhi)接(jie)(jie)地(di)引下(xia)線與主接(jie)(jie)地(di)網(wang)連(lian)(lian)接(jie)(jie)點(dian)電(dian)阻增大(da),從而不能(neng)滿足(zu)電(dian)力(li)規程(cheng)的(de)(de)要求,使設(she)備(bei)(bei)在運行(xing)中存在不**隱患(huan),嚴(yan)重時(shi)會造(zao)成(cheng)設(she)備(bei)(bei)失地(di)運行(xing)。我(wo)公司利(li)用自(zi)(zi)(zi)身(shen)技術優勢研制了(le)系列接(jie)(jie)地(di)引下(xia)線導(dao)通(tong)測試(shi)儀。該儀器采用全新(xin)電(dian)源(yuan)技術,具有體積(ji)小、重量輕、輸出電(dian)流大(da)并且可(ke)(ke)根據負載大(da)小自(zi)(zi)(zi)動(dong)(dong)調(diao)整等(deng)特點(dian)。整機由單(dan)片機控(kong)制,自(zi)(zi)(zi)動(dong)(dong)完成(cheng)自(zi)(zi)(zi)檢、數據處理、顯示(shi)、打印等(deng)功能(neng),具有自(zi)(zi)(zi)動(dong)(dong)放電(dian)和放電(dian)指示(shi)功能(neng)。儀器測試(shi)精(jing)度(du)高,操作(zuo)簡便,可(ke)(ke)實現(xian)接(jie)(jie)地(di)電(dian)阻的(de)(de)快速(su)測量。
一、WBDT-V接地導通測試儀
y>
??電流變頻地網接地電阻儀**措施
使用本儀器前一定要(yao)認(ren)真閱(yue)讀本手冊。
儀器的操作者應(ying)具備(bei)一般(ban)電氣設(she)備(bei)或(huo)儀器的使(shi)用常識。
本儀器戶內外均(jun)可使用,但應避開雨淋、腐蝕氣體、塵(chen)埃過濃、高溫、陽(yang)光直射等場所。
儀表應避免(mian)劇(ju)烈振動(dong)。
對(dui)儀(yi)器的維修、護理和調整(zheng)應(ying)由專業(ye)人員進行。
測試(shi)完畢后(hou)一定要等放(fang)電報(bao)警(jing)聲停(ting)止后(hou)再關閉電源,拆除測試(shi)線。
在測試過程中,禁止移動(dong)測試夾(jia)和供電線路。
二(er)、WBDT-V接地導通測試儀
y>
??電流變頻地網接地電阻儀性能特(te)點
儀器輸出電(dian)流大,測量范(fan)圍寬,操作簡便;
儀器(qi)具有完善的反電(dian)勢(shi)保(bao)護功能,音響放(fang)電(dian)報(bao)警(jing),放(fang)電(dian)指示清(qing)晰,減少誤操作;
儀器裝有打印機,可隨時打印測試數據;
儀(yi)器具有實時時鐘,并可連同(tong)測試記錄一(yi)起保存、打印,方便用戶保存、查(cha)閱;
儀器(qi)內部(bu)可以長久(jiu)存儲測(ce)試數據200條(tiao)(可擴展(zhan)),還可以(yi)使用優盤存儲數據(ju)方便用戶導入電腦處理。
儀器具有適(shi)用溫度寬,精(jing)度高(gao),防震,抗干擾,體積小,重量輕,攜(xie)帶(dai)方(fang)便等(deng)特點。
三、WBDT-V接地導通測試儀
y>
??電流變頻地網接地電阻儀技術指標
測試電流:0.2A、1A、5A、10A四檔
測試范圍:0.2 A 10 Ω ~ 100Ω
1 A 100mΩ
~ 20 Ω
5 A 10 mΩ
~ 4 Ω
10 A 1 mΩ ~ 2 Ω
準確度(du):±(讀數×0.2%+2字)
*高分(fen)辨(bian)率: 0.1μΩ
工作溫度:-5~40℃;環境濕度:≤90%RH,無(wu)結(jie)露
工作電源:AC220V±10%,50HZ±1HZ
體(ti)積:390×280×200mm
重量:7Kg(不包(bao)括測試線)
四、WBDT-V接地導通測試儀
y>
??電流變頻地網接地電阻儀面板(ban)功(gong)能介紹
儀器面板(ban)見圖一。
電源開關(guan):整機(ji)電源輸(shu)入(ru)口,帶有(you)交流插座(zuo),保(bao)險(xian)倉和開關(guan)。
: 接地柱,為整機外(wai)殼接地用,屬保(bao)護地。
V+、V-: 電(dian)壓輸入端子。
I+、I-: 電流輸出端(duan)子。
顯示(shi)器: 128×64點(dian)陣液(ye)晶(jing)顯示器,人機交(jiao)互界面。
打印機: 打印(yin)輸(shu)出(chu)直流(liu)電(dian)阻測(ce)試結(jie)果(guo)。
USB: 優盤接口
RS232: 儀器與計算機連(lian)接的通訊接口
返回鍵: 返(fan)回上級菜單界面或取消當前操作(zuo)。
選擇鍵: 在儀器操作過程中移(yi)動(dong)光標(biao)。
確認(ren)鍵: 修改參數(shu)或執行(xing)所選操作。
五(wu)、WBDT-V接地導通測試儀
y>
??電流變頻地網接地電阻儀使用說(shuo)明(ming)
1、儀器開(kai)機顯示畫面(mian)
打(da)開電源開關(開關上I為開,O為關),儀(yi)器(qi)顯示區將顯示圖三界面。
2、時鐘界面
放電檢(jian)測完畢(bi)后,儀器自動進入時鐘界面。
此(ci)界面(mian)實時顯示(shi)系統時鐘,用(yong)戶可按(an)(an)“確(que)(que)(que)認”鍵(jian)(jian)(jian)直接進(jin)入主菜(cai)單界面(mian)。如(ru)用(yong)戶想(xiang)修改(gai)時鐘,可按(an)(an)選擇鍵(jian)(jian)(jian)移動(dong)光標(字體反白顯示(shi)為(wei)光標選中狀態),此(ci)時按(an)(an)“確(que)(que)(que)認”鍵(jian)(jian)(jian)可實現數(shu)值加一功能(neng),當光標移動(dong)到“確(que)(que)(que)定(ding)(ding)”按(an)(an)鈕時,按(an)(an)“確(que)(que)(que)認”鍵(jian)(jian)(jian)即(ji)可設(she)定(ding)(ding)時鐘并進(jin)入主菜(cai)單界面(mian),如(ru)中途用(yong)戶不想(xiang)修改(gai)時鐘了,可按(an)(an)“返(fan)回(hui)”鍵(jian)(jian)(jian)推(tui)出設(she)定(ding)(ding)界面(mian),儀(yi)器仍將實時刷新(xin)時鐘,再按(an)(an)“確(que)(que)(que)認”鍵(jian)(jian)(jian)即(ji)可進(jin)入主菜(cai)單界面(mian)。
3、主菜單界面(mian)
按“選(xuan)擇”鍵(jian)移動(dong)光標(biao),按“確(que)認”鍵(jian)進入所選(xuan)菜(cai)單,按“返回(hui)”鍵(jian)回(hui)到上(shang)一頁。
3.1導通測試菜單(dan)
按“選擇”移動(dong)光標,當光標選中(zhong)“電(dian)流選擇:xxxA”時,按(an)“確認”可修改電流值(0.2A→1A→5A→10A→0.2A循環顯示(shi));當(dang)光(guang)標移動到“確定”按(an)(an)鈕(niu)時,按(an)(an)確認鍵(jian)即可按(an)(an)當(dang)前選定的(de)測(ce)試電流進(jin)行(xing)測(ce)試,進(jin)入圖(tu)(tu)七→圖(tu)(tu)八→圖(tu)(tu)九界面(mian)。
當進度條到達右端(duan),表示測試完畢,將顯示測試結果如(ru)圖十
此時界面顯示的電(dian)阻值(zhi)為實時測量值(zhi),用戶可按(an)“選擇(ze)”鍵(jian)選擇(ze)“保存”或是“打印”,按(an)“確認”鍵(jian)執行所選操作,按(an)“返(fan)回(hui)”鍵(jian)儀器停止測試并開(kai)始放電(dian)如圖十一
放電完畢后,儀(yi)器將返(fan)回到圖六界(jie)面。
當在(zai)圖(tu)十(shi)界面中(zhong)用戶(hu)選擇保存時,儀器將提示用戶(hu)選擇存儲介質如(ru)圖(tu)十(shi)二
按“選擇”鍵移動光標,按“確認”鍵保存到(dao)相應(ying)存儲(chu)介質(zhi)并(bing)返回(hui)到(dao)圖十界面,實(shi)時(shi)刷(shua)新測(ce)量結果(guo)(guo),也(ye)可不保存按“返回(hui)”回(hui)到(dao)圖十界面,實(shi)時(shi)刷(shua)新測(ce)量結果(guo)(guo)。
注:整(zheng)個(ge)測試過(guo)程(cheng)中切(qie)勿拆(chai)線(xian),待放電完畢方(fang)可拆(chai)線(xian)。
3.2、數據存取菜單(dan)
按(an)“選擇(ze)”鍵移動(dong)光標,按(an)“確(que)認”鍵執(zhi)行所(suo)選操作,按(an)“返(fan)回”鍵回到主菜單。
六、注意事項
測(ce)試(shi)過程(cheng)中嚴禁拆(chai)除測(ce)試(shi)下(xia)和切斷(duan)系(xi)統電源。
在拆線(xian)前(qian),一定要等放電結束后,報警聲停止,再進行(xing)拆線(xian)。
如果測(ce)試線沒接好,儀器會自動提示“電(dian)源(yuan)開路(lu)”。這時須檢查線路(lu)是否有(you)正確或沒接牢固,然后按復位鍵(jian)重新測(ce)量。
七、售后服務
1、凡購(gou)本公司產品隨機(ji)攜帶產品保(bao)修(xiu)(xiu)單(dan),訂(ding)購(gou)產品交貨時,請當(dang)場檢驗并(bing)填好保(bao)修(xiu)(xiu)單(dan)。
2、自購(gou)機之日起,憑保(bao)修(xiu)(xiu)單保(bao)修(xiu)(xiu)二(er)年,終(zhong)身(shen)維護。在保(bao)修(xiu)(xiu)期內,維修(xiu)(xiu)不收維修(xiu)(xiu)費;保(bao)修(xiu)(xiu)期外,維修(xiu)(xiu)調試(shi)收取適當費用。
3、屬下(xia)列(lie)情況之一者不予保修:
1)用戶對(dui)儀器有(you)自行拆卸或對(dui)儀器工藝結構(gou)有(you)人為改變。
2)因用戶保管(guan)或使用不當造成儀器的嚴重損壞。
3)屬(shu)于用戶其它原因造成的(de)損壞。
裝箱單
儀器(qi)名稱:接地引下線導(dao)通測試(shi)儀
測試儀主機
|
一(yi)臺
|
測試線(xian)
|
二條(紅黑)
|
三芯電源線
|
一條(tiao)
|
接地線
|
一條(tiao)
|
保險管(3A)
|
三支
|
打印(yin)紙
|
二卷
|
測(ce)試報告
|
一份(fen)
|
裝箱單
|
一張
|
使用說明書
|
一本
|
合格證 保修(xiu)卡
|
一張(zhang)
|