一(yi)、WBHL-2000高壓開關回路電阻分析儀產品簡介
WBHL-2000回路電(dian)阻測試儀是(shi)公司根(gen)據IEC標準(zhun)及(ji)中華人民共(gong)和國*新電力執(zhi)行(xing)標準(zhun)DL/T845.4- 2004有關規定,發揮(hui)自身(shen)技(ji)術(shu)優勢,精心研制的(de)高(gao)(gao)精度(du)、數字化開(kai)關檢測(ce)(ce)儀器。該(gai)儀器采用(yong)高(gao)(gao)頻大功率恒(heng)流(liu)開(kai)關電(dian)(dian)(dian)(dian)源技(ji)術(shu),可(ke)測(ce)(ce)得微歐姆級接(jie)觸(chu)電(dian)(dian)(dian)(dian)阻(zu)(zu)(zu)。廣(guang)泛(fan)適用(yong)于各種開(kai)關及(ji)電(dian)(dian)(dian)(dian)器的(de)接(jie)觸(chu)電(dian)(dian)(dian)(dian)阻(zu)(zu)(zu)、回路(lu)電(dian)(dian)(dian)(dian)阻(zu)(zu)(zu)及(ji)電(dian)(dian)(dian)(dian)纜電(dian)(dian)(dian)(dian)線、焊(han)縫接(jie)觸(chu)電(dian)(dian)(dian)(dian)阻(zu)(zu)(zu)的(de)測(ce)(ce)量,儀器測(ce)(ce)量數據準確(que),性能穩定,滿足(zu)電(dian)(dian)(dian)(dian)力、供電(dian)(dian)(dian)(dian)部門(men)現場高(gao)(gao)壓(ya)開(kai)關維修和(he)高(gao)(gao)壓(ya)開(kai)關廠回路(lu)電(dian)(dian)(dian)(dian)阻(zu)(zu)(zu)測(ce)(ce)試的(de)要(yao)求(qiu)。輸出(chu)電(dian)(dian)(dian)(dian)流(liu)和(he)測(ce)(ce)量電(dian)(dian)(dian)(dian)阻(zu)(zu)(zu)同(tong)時輸出(chu)在65K真彩色液晶上,測(ce)量結果即可電壓輸出(chu)也可U盤存(cun)儲(chu),掉電存(cun)儲(chu)可滿(man)足(zu)隨時數據查詢(xun)。
二、WBHL-2000高壓開關回路電阻分析儀性能特點
1、測試電(dian)流大,完全(quan)符合有關測試接觸(chu)電(dian)阻的國家標準(zhun)要求。
2、輸出電壓高(gao),測量量程寬。
3、測試電(dian)(dian)流(liu)(liu)來自高精(jing)度的大(da)電(dian)(dian)流(liu)(liu)恒流(liu)(liu)電(dian)(dian)源,無需(xu)人工調節,測試迅速準確。
4、采用四端(duan)子(zi)接線(xian)法,有(you)效(xiao)地排除(chu)了測(ce)試線(xian)電阻對(dui)測(ce)試結果(guo)的影響。
5、320X240點陣的超小像素點的65K真彩色液晶,
6、儀(yi)器(qi)自帶萬(wan)年歷時(shi)鐘和掉(diao)電存儲,可存儲測試(shi)數據,隨時(shi)查閱
7、儀器配備微型打印(yin)機(ji)、RS232和(he)USB接口,可和計算機通訊以(yi)及U盤存儲
8、智(zhi)能化(hua)功(gong)率(lv)管(guan)理技術,儀(yi)器總是工作在*小功(gong)率(lv)狀態,有效節約能源。
三、WBHL-2000高壓開關回路電阻分析儀技術指標(biao)
1、測(ce)試電流:100A,200A,400A,600A;
2、量(liang)程:0~200mΩ
3、分辨率:*小0.1μΩ
4、精(jing)度(du):±(0.5%±2個字)
5、功率:1000-4000W
6、工作方式:連續測量(liang)
7、工(gong)作電源:AC220V±10% 50HZ
8、使用溫(wen)度:0~40℃
9、相對濕度:小于等于90% 無(wu)結露
10、外形尺寸:355*275*147
11、重量(liang):9.5-20KG
四、WBHL-2000高壓開關回路電阻分析儀操作(zuo)功能介紹(shao)
1、電源開關:“I”按下儀器開(kai)始供電,“O”按下(xia)關斷(duan)儀器電源
2、AC220V:儀器(qi)(qi)供電源輸入端(duan),本(ben)儀器(qi)(qi)采用交流220V供(gong)電
3、I+、I-:為電流輸出端子,通過專用測(ce)試線為試品提供100A恒定電流
4、V+、V-:為試(shi)品(pin)電壓信(xin)號的輸入端子
5、液晶(jing):采用320X240真(zhen)彩色液晶,強光下字(zi)體(ti)也可清晰(xi)觀察,顯示操(cao)作(zuo)設置,測試結果,接觸電阻值和輸(shu)出電流值
6、RS232:串(chuan)口輸出端(duan)
7、復位(wei)鍵:整機初始化,儀器處在(zai)準備(bei)狀態
8、選擇鍵:按下此(ci)鍵,選擇儀(yi)器(qi)各項設置,測量結(jie)束可打(da)印(yin)數據
9、循環鍵:主菜單循環選擇鍵或(huo)U盤存儲(chu)
9、確(que)(que)認鍵:按下(xia)確(que)(que)認鍵儀器開始(shi)啟動電流進行測試
10、:儀(yi)器接(jie)地端。
11、 USB:U盤接口
12、打印機(ji):熱敏打印機(ji),打印測量(liang)結果
五、WBHL-2000高壓開關回路電阻分析儀菜單(dan)操作
開機菜(cai)單顯示如下(xia):
按循環(huan)鍵(jian)光(guang)標可在(zai)(zai)參數(shu)設(she)置、數(shu)據查詢、時(shi)(shi)鐘(zhong)修(xiu)改(gai)、測量時(shi)(shi)間(jian)、選(xuan)(xuan)擇電流之間(jian)循環(huan)移動,光(guang)標在(zai)(zai)參數(shu)設(she)置、數(shu)據查詢、時(shi)(shi)鐘(zhong)修(xiu)改(gai)時(shi)(shi)按選(xuan)(xuan)擇鍵(jian)可進入選(xuan)(xuan)中(zhong)菜單的下**菜單,光(guang)標在(zai)(zai)測量時(shi)(shi)間(jian)項按選(xuan)(xuan)擇鍵(jian)時(shi)(shi)間(jian)可在(zai)(zai)脈(mo)沖、30秒、1分鐘、5分鐘、10分鐘、連(lian)續之間循環移動,任何時候按啟動鍵(jian)可進入測量狀態(tai),
六、測量方法
注意:測試鉗的全部連接面(mian)應與試品可(ke)靠接觸,若發(fa)現接觸面(mian)有氧化(hua)現象,應首先去(qu)除接觸面(mian)的氧化(hua)層。
1、接(jie)(jie)線(xian)方法:如圖二所(suo)示,將專用測試(shi)線(xian)按(an)照(zhao)顏色紅(hong)對紅(hong),黑對黑,粗的(de)電流(liu)線(xian)接(jie)(jie)到對應的(de)I+、I-接線柱扭緊(jin),細的電(dian)源線插入到V+、V-的插座內,兩把夾鉗夾住被測試品的兩端。
2、測(ce)量(liang):接圖(tu)二完成接線后,打開電源開關,選擇好測(ce)試(shi)時間進行測(ce)試(shi),儀器(qi)會自動完成充電、穩流和電阻(zu)測(ce)量(liang)。
3、操(cao)作步驟(zou):
1)、按要求完成儀器端(duan)和被(bei)測量(liang)試品端(duan)的(de)接線
2)、接通AC220V交流(liu)電源,打開(kai)電源開(kai)關,屏幕如(ru)前(qian)面講到的開(kai)機界面,通過選擇鍵(jian)(jian)選擇適合(he)的測量時間(jian)后(hou),按下啟動鍵(jian)(jian)柯(ke)進入測量過程
3)、當(dang)選擇好(hao)測量時(shi)間時(shi),按(an)下啟動鍵儀(yi)器啟動電流(liu)(liu),屏幕(mu)顯(xian)示“正在充(chong)電”同時(shi)顯(xian)示儀(yi)器輸出電流(liu)(liu),電流(liu)(liu)輸出達(da)到預定值(zhi)且穩定后(hou),屏幕(mu)顯(xian)示“正在測試”,幾秒(miao)鐘(zhong)后(hou)顯(xian)示被測阻值(zhi)及電流(liu)(liu)值(zhi)
4)、測試過程中如(ru)果想保存測試值,按下選擇鍵(jian)約2秒開始(shi)打印當前數據(ju),測(ce)量時間到達后儀器停(ting)止測(ce)量,屏幕不(bu)再閃動,并顯示提示儀器如何打印和U盤存(cun)儲
5)、測試過程中(zhong)按(an)下復(fu)位鍵或(huo)測試結(jie)(jie)束,儀器輸出電流均變為零(ling),測量結(jie)(jie)束后,應先關(guan)閉電源,然(ran)后拆除引(yin)線,準備下一個試驗項目(mu)。
七、**措施
1、操作者應具備一般(ban)電(dian)器設備或儀器的使用常識。
2、測試(shi)結束后,按復位鍵(jian),關掉電(dian)(dian)源開關。注意:嚴禁帶電(dian)(dian)拆裝各測試(shi)電(dian)(dian)纜。
3、儀器出現不正常(chang)現象,首先按復位鍵,使儀器復位。
4、對(dui)儀器進(jin)行(xing)(xing)維(wei)修必須由(you)專業人員進(jin)行(xing)(xing),不得自行(xing)(xing)處(chu)理。
5、本儀器(qi)為(wei)測(ce)量回路電阻使(shi)用,不允(yun)許測(ce)量感性回路。
八、儀器(qi)成套組(zu)成
主機(ji)
|
一臺
|
測試線
|
一套(tao)
|
電源線
|
一條
|
操作手冊
|
一本
|
九、售后服務
儀器自購買之日起壹(yi)年內屬產(chan)品(pin)質量問題免(mian)費包修(xiu)包換,終身(shen)提供保修(xiu)和(he)技術服(fu)務。如發現儀器有不(bu)正常(chang)情況或故障,請與公司及(ji)時聯系,以(yi)便(bian)為您安排*便(bian)捷的處理方(fang)案。