產品資料您的位置:主頁 > 產品中心 > 高壓成套、耐壓測試、電氣設備 > 變頻串并聯諧振耐壓試驗

諧振變

如(ru)果您(nin)對(dui)該產品感興(xing)趣的話,可以
產品名稱: 諧振變
產品型號: WBYD2000
產品展商: 其(qi)它(ta)品牌
產品文檔: 無相關文檔
產品簡介

WBYD2000諧振變就是一臺幅值和頻率可調的正弦波交流調頻電源,給諧振回路提供激勵源,同時提供電壓顯示、電流顯示、計時、保護、報警等功能。諧振變就是一個大電感線圈,與被試品(相當于電容)構成回路,可配置電抗器多節電抗器,使用時通過不同的串聯、并聯組合、實現不同的電感量以適用不同的試驗條件。

詳細介紹


一、WBYD2000諧振變基本原理

耐(nai)壓試(shi)驗(yan)是利用電(dian)(dian)抗器的(de)電(dian)(dian)感與被(bei)試(shi)品(pin)電(dian)(dian)容組成LC串聯回(hui)路(lu),調(diao)節變頻電(dian)(dian)源輸出的(de)電(dian)(dian)壓頻率,在被(bei)試(shi)品(pin)上獲得(de)高(gao)電(dian)(dian)壓,是當前高(gao)電(dian)(dian)壓試(shi)驗(yan)的(de)一(yi)種新方(fang)法(fa),深受專(zhuan)家(jia)好評,在國內外已經得(de)到廣泛的(de)使(shi)用。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

根據諧振(zhen)原理,我們知道當電抗(kang)器L的感抗(kang)值Xl與回(hui)(hui)路中(zhong)的容(rong)抗(kang)值Xc相等(deng)時,回(hui)(hui)路達到諧振(zhen)狀態,此(ci)時回(hui)(hui)路中(zhong)僅(jin)回(hui)(hui)路電阻R消耗有功(gong)功(gong)率,而(er)無功(gong)功(gong)率則在(zai)電抗(kang)器與試品(pin)電容(rong)之(zhi)間(jian)來回(hui)(hui)振(zhen)蕩,從而(er)在(zai)試品(pin)上產(chan)生高壓(ya)。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

二、WBYD2000諧振變系統構成

全(quan)套試驗系統(tong)由(you)調頻電(dian)源主(zhu)機(ji)、電(dian)抗器(qi)、分壓(ya)器(qi)、激勵變壓(ya)器(qi)和補償電(dian)容器(qi)(可選器(qi)件)組成,接入被試品后(hou)組成一個諧振(zhen)系統(tong)進行交流耐(nai)壓(ya)實(shi)驗。

主(zhu)機: 就是一臺幅(fu)值和頻率可調(diao)的正弦(xian)波(bo)交流調(diao)頻電源,給(gei)諧振(zhen)回路(lu)提(ti)供(gong)(gong)激(ji)勵源,同(tong)時(shi)提(ti)供(gong)(gong)電壓(ya)顯(xian)示(shi)、電流顯(xian)示(shi)、計時(shi)、保護(hu)、報警等功能。

電(dian)抗(kang)器(qi):就是(shi)一個大(da)電(dian)感(gan)線圈(quan),與(yu)被試(shi)品(相(xiang)當(dang)于電(dian)容)構成(cheng)回路,可配(pei)置電(dian)抗(kang)器(qi)多節電(dian)抗(kang)器(qi),使(shi)用(yong)時通過不(bu)同的(de)(de)串聯(lian)、并聯(lian)組合、實(shi)現不(bu)同的(de)(de)電(dian)感(gan)量以適用(yong)不(bu)同的(de)(de)試(shi)驗(yan)條件(jian)。

分壓器:內部通過(guo)電(dian)(dian)容(rong)器分壓,從試(shi)品上高電(dian)(dian)壓分得低電(dian)(dian)壓供主(zhu)機測量、控制使用。

勵磁變(bian)壓器:隔離主機電(dian)(dian)源與諧振回(hui)路(lu)電(dian)(dian)源,并升高主機的輸出電(dian)(dian)壓。

補(bu)償電容(rong)(rong)器:當試品電容(rong)(rong)量很小時,如果要實現(xian)系統諧(xie)振可能要求(qiu)的電源頻率超出試驗標準(zhun)的規(gui)定(ding),可在試品上并聯一個補(bu)償電容(rong)(rong),以(yi)實現(xian)試驗要求(qiu),稱(cheng)此(ci)電容(rong)(rong)器為補(bu)償電容(rong)(rong)器。

三、WBYD2000諧振變主要技術性能

功率電源(yuan)電壓:AC380V±10%、50Hz;

儀(yi)器電源:220V±10%、50Hz;

諧振輸出容(rong)量:200kVA;

儀器(qi)額(e)定電壓(ya):0~200kV;

輸出頻率范圍(wei):30~300Hz;

輸出(chu)電(dian)壓(ya)波(bo)(bo)形:正(zheng)弦波(bo)(bo),波(bo)(bo)形畸變率(lv)<0.5%;

頻率調節靈(ling)敏度(du):0.1Hz,不穩定度(du)≤0.05%;

系統噪(zao)聲(sheng):≤60db;

9、系統測量精度:<1級;

10.輸(shu)出電壓不穩定:<0.5%;

11.保護(hu)響應時間:1us;

12.電(dian)感非線性度:≤0.05%;;

13.滿功(gong)率輸出(chu)下,連(lian)續(xu)工作時間(jian)為60min

14.環境溫度:-15℃~+50℃;

15.相(xiang)對濕度:≤90%RH;

16.海拔高度(du):≤2000米。

四、WBYD2000諧振變面板及部件名稱

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

五、WBYD2000諧振變操作步驟

1、正確連線,檢查無誤后方可(ke)送電。

必要時(shi)工作(zuo)電源的跳過現(xian)場漏電保安(an)器,以免不必要的跳閘。

2、打開電源開關,主機開始工(gong)作,液晶屏顯示版(ban)權頁(ye),該頁(ye)標明本裝置的軟件版(ban)本號。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

觸按確(que)認(ren)鍵(jian),進入系統(tong)(tong)菜單(dan)(dan),該(gai)主菜單(dan)(dan)下有:試驗(yan)方(fang)案、開始試驗(yan)、試驗(yan)幫(bang)助、系統(tong)(tong)設置(zhi)、實(shi)用工具和試驗(yan)記錄等六(liu)個子菜單(dan)(dan)項。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

3、 系(xi)統設(she)(she)置(zhi)菜單(dan)下有電(dian)抗(kang)器(qi)電(dian)感、日期時間(jian)設(she)(she)置(zhi)和采(cai)樣(yang)系(xi)數(shu)設(she)(she)置(zhi)等三個子菜單(dan)項。按上下鍵,上下移動光標系(xi)統參(can)數(shu)設(she)(she)置(zhi)菜單(dan)項,觸按確定(ding)鈕(niu)后(hou),進入系(xi)統參(can)數(shu)設(she)(she)置(zhi)菜單(dan),可以分別設(she)(she)定(ding)電(dian)抗(kang)器(qi)的(de)電(dian)感—H、-年(nian)-月(yue)-日、-時-分-秒和電(dian)壓和電(dian)流(liu)的(de)采(cai)樣(yang)系(xi)數(shu)也就是采(cai)樣(yang)倍率(lv),設(she)(she)定(ding)完成后(hou),觸按返還(huan)鍵返回(hui)上**菜單(dan)。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

電(dian)抗(kang)器電(dian)感量的(de)設定:按確定鍵(jian)選(xuan)擇到(dao)此(ci)項(xiang),按左右(you)鍵(jian)移動光標需要改變的(de)數(shu)位,按上下鍵(jian)改變數(shu)值,達到(dao)所(suo)要達到(dao)的(de)數(shu)值按確定鍵(jian)確認。

日(ri)(ri)期時間的設(she)定(ding):按(an)確(que)定(ding)鍵(jian)(jian)選擇到(dao)此項,按(an)左右鍵(jian)(jian)移動光標需要改(gai)變的數位,按(an)上下鍵(jian)(jian)改(gai)變數值,按(an)照所要設(she)置(zhi)的年月日(ri)(ri)時間數值按(an)確(que)定(ding)鍵(jian)(jian)確(que)認。

采樣(yang)系數的(de)設定(ding)(ding):按確定(ding)(ding)鍵選擇到高壓(ya)/電流采樣(yang)系數項(xiang)(xiang),此項(xiang)(xiang)為(wei)電壓(ya)或(huo)電流采樣(yang)倍率的(de)設定(ding)(ding)。一(yi)般出廠前設定(ding)(ding)好了(le)。如需修改,要輸(shu)入密碼(ma)。(密碼(ma)廠家與設備一(yi)起提供一(yi)般設定(ding)(ding)為(wei):188888)

警告(gao):系統默認上一次電(dian)(dian)(dian)抗器(qi)電(dian)(dian)(dian)感(gan)、日(ri)期時間和采樣(yang)系數(shu)設定值。如果需改變要重新設定。電(dian)(dian)(dian)抗器(qi)電(dian)(dian)(dian)感(gan)量(liang)設定值與(yu)實際使用的電(dian)(dian)(dian)抗器(qi)電(dian)(dian)(dian)感(gan)量(liang)不對(dui),會導致(zhi)試驗報告(gao)中(zhong)的被試品電(dian)(dian)(dian)容量(liang)不準。其他(ta)并不會影響。采樣(yang)系數(shu)設置(zhi)不正確,會導致(zhi)顯示電(dian)(dian)(dian)壓電(dian)(dian)(dian)流不準將很有可能會對(dui)被試品或(huo)試驗設備造(zao)成損壞。

4、試驗方案菜單下有預(yu)置(zhi)保(bao)護(hu)(hu)電流、找(zhao)頻(pin)(pin)(pin)(pin)起(qi)始頻(pin)(pin)(pin)(pin)率(lv)(lv)、找(zhao)頻(pin)(pin)(pin)(pin)結束頻(pin)(pin)(pin)(pin)率(lv)(lv)、預(yu)定(ding)起(qi)始功(gong)率(lv)(lv)四個子(zi)菜單項,分別設(she)定(ding)本(ben)次試驗的保(bao)護(hu)(hu)電流、找(zhao)頻(pin)(pin)(pin)(pin)起(qi)始頻(pin)(pin)(pin)(pin)率(lv)(lv)、找(zhao)頻(pin)(pin)(pin)(pin)結束頻(pin)(pin)(pin)(pin)率(lv)(lv)、輸出起(qi)始功(gong)率(lv)(lv),全部設(she)定(ding)完成后,觸按返還鍵(jian)進(jin)入(ru)預(yu)置(zhi)試驗電壓和(he)預(yu)置(zhi)試驗時間設(she)置(zhi)菜單。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

可(ke)以(yi)分3段時(shi)(shi)間(jian)設(she)置(zhi)試驗(yan)電壓(ya)和(he)試驗(yan)時(shi)(shi)間(jian), 實際試驗(yan)時(shi)(shi),若設(she)定為(wei)自(zi)動試驗(yan), 裝置(zhi)將按設(she)定的3段電壓(ya)及時(shi)(shi)間(jian),按順序分別加(jia)壓(ya), 全部完成后(hou)自(zi)動退出.

如果**段(duan)電(dian)壓(ya)(ya)設(she)為0, 或時間設(she)為0, 那么執行完**段(duan)試(shi)(shi)驗(yan)電(dian)壓(ya)(ya)加(jia)壓(ya)(ya)后(hou)退出(chu)試(shi)(shi)驗(yan), 只加(jia)壓(ya)(ya)**段(duan)設(she)定的電(dian)壓(ya)(ya).

如果第三(san)段電壓(ya)設為0, 或時間設為0, 不執行(xing)第三(san)段加(jia)壓(ya).

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

試(shi)(shi)(shi)驗(yan)(yan)(yan)方(fang)(fang)案(an)設(she)置的(de)(de)設(she)定(ding)(ding):在(zai)試(shi)(shi)(shi)驗(yan)(yan)(yan)電壓(ya)項中,按確定(ding)(ding)單(dan)鈕(niu)(niu),移(yi)動(dong)左右光標到(dao)需要(yao)改變的(de)(de)數(shu)(shu)(shu)位,按上(shang)下單(dan)鈕(niu)(niu)以改變當(dang)前數(shu)(shu)(shu)位的(de)(de)數(shu)(shu)(shu)值大小,觸按返(fan)回鈕(niu)(niu)完(wan)成當(dang)前數(shu)(shu)(shu)位的(de)(de)數(shu)(shu)(shu)值設(she)定(ding)(ding),依次(ci)選擇下一項數(shu)(shu)(shu)值的(de)(de)設(she)定(ding)(ding),直(zhi)至分別完(wan)成試(shi)(shi)(shi)驗(yan)(yan)(yan)時間、起始頻(pin)率、起始功(gong)率的(de)(de)設(she)置,方(fang)(fang)可(ke)完(wan)成本(ben)次(ci)試(shi)(shi)(shi)驗(yan)(yan)(yan)的(de)(de)試(shi)(shi)(shi)驗(yan)(yan)(yan)方(fang)(fang)案(an)設(she)置的(de)(de)設(she)定(ding)(ding)。

出廠(chang)默認值:試驗電壓(ya) 20kV、加壓(ya)時(shi)間 2min、激(ji)勵強度&nbsp;2%、輸出電流20A、頻率范圍30-300Hz。

5、實用工具菜單下(xia)有

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

頻(pin)率(lv)計算:在實驗(yan)(yan)前可對諧(xie)振頻(pin)率(lv)進行計算。只需輸入具(ju)體參與(yu)試驗(yan)(yan)的電感、電容值(zhi)并按確(que)定鍵試驗(yan)(yan)頻(pin)率(lv)即直接(jie)生成(cheng)。


6、開(kai)始試(shi)驗菜單下有自動試(shi)驗模(mo)式和手動試(shi)驗模(mo)式兩種子菜單可供選擇(ze)。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

按確認鍵進(jin)入所(suo)選試驗步驟.

自(zi)(zi)動試驗模式(shi)的操作:選中自(zi)(zi)動試驗模式(shi)后,觸按菜單鈕進入正在自(zi)(zi)動尋找諧振點(dian)(dian)菜單項,裝置在設(she)(she)定的頻率(lv)(lv)(lv)范(fan)(fan)圍(wei)內自(zi)(zi)動尋找諧振點(dian)(dian)(如果被試品(pin)(pin)電(dian)容C和電(dian)抗器電(dian)感(gan)L的實際諧振頻率(lv)(lv)(lv)不(bu)在設(she)(she)定的頻率(lv)(lv)(lv)范(fan)(fan)圍(wei)內,將找不(bu)到諧振點(dian)(dian),此時(shi)根據(ju)需要(yao)調整頻率(lv)(lv)(lv)范(fan)(fan)圍(wei)或調整被試品(pin)(pin)回路(lu)的LC參數)。當找到諧振點(dian)(dian)時(shi),會有聲(sheng)音提(ti)示。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

找到諧振點后,裝置(zhi)自動進入(ru)正在自動升(sheng)壓菜(cai)單項(xiang),當升(sheng)到試驗電壓設定的電壓時,裝置(zhi)停止加壓。

當裝置升到(dao)試(shi)驗(yan)(yan)(yan)(yan)電壓設定的電壓時(shi),設備(bei)停止加壓,自動進入(ru)正在加壓試(shi)驗(yan)(yan)(yan)(yan)菜(cai)單項,并自動記錄試(shi)驗(yan)(yan)(yan)(yan)的加壓時(shi)間,當加壓時(shi)間到(dao)達設定時(shi)間時(shi),設備(bei)逐步降壓退出試(shi)驗(yan)(yan)(yan)(yan),完成(cheng)本(ben)次試(shi)驗(yan)(yan)(yan)(yan),進入(ru)試(shi)驗(yan)(yan)(yan)(yan)結(jie)束(shu)菜(cai)單項。并可選擇保存(cun)試(shi)驗(yan)(yan)(yan)(yan)數據(ju)(ju)或打印(yin)試(shi)驗(yan)(yan)(yan)(yan)數據(ju)(ju)。

試驗(yan)時間(jian)的一(yi)行顯示(shi)末端,會(hui)顯示(shi)[一(yi)段(duan)]或(huo)(huo)[二(er)(er)段(duan)]或(huo)(huo)[三段(duan)]字(zi)樣,表示(shi)當(dang)前正在(zai)進行的加壓試驗(yan)是預置的一(yi)段(duan),二(er)(er)段(duan)或(huo)(huo)三段(duan).


手動(dong)試(shi)驗(yan)(yan)模式(shi)的操作:選中手動(dong)試(shi)驗(yan)(yan)模式(shi)后觸(chu)按(an)確定鈕(niu),進入正在試(shi)驗(yan)(yan)菜單項;手動(dong)按(an)調(diao)(diao)頻(pin)(pin)(pin)鈕(niu),對應的光(guang)標隨之改變(bian)到輸(shu)出頻(pin)(pin)(pin)率(lv)(lv)(lv)項,可以通過上(shang)(shang)下左右鍵(jian)改變(bian)頻(pin)(pin)(pin)率(lv)(lv)(lv)大(da)小使(shi)其(qi)試(shi)驗(yan)(yan)電壓(ya)(ya)(ya)逐(zhu)步升高(gao),當升到*高(gao)電壓(ya)(ya)(ya)時,繼續向(xiang)上(shang)(shang)或向(xiang)下調(diao)(diao)整頻(pin)(pin)(pin)率(lv)(lv)(lv)按(an)鈕(niu),直至試(shi)驗(yan)(yan)電壓(ya)(ya)(ya)開始下降;這時反(fan)調(diao)(diao)頻(pin)(pin)(pin)率(lv)(lv)(lv),試(shi)驗(yan)(yan)電壓(ya)(ya)(ya)又逐(zhu)步回升,上(shang)(shang)下回調(diao)(diao)頻(pin)(pin)(pin)率(lv)(lv)(lv),從頻(pin)(pin)(pin)率(lv)(lv)(lv)的高(gao)位(wei)(wei)到低位(wei)(wei)逐(zhu)位(wei)(wei)調(diao)(diao)整*高(gao)電壓(ya)(ya)(ya)值時的頻(pin)(pin)(pin)率(lv)(lv)(lv)就是(shi)當前的諧振頻(pin)(pin)(pin)率(lv)(lv)(lv)。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

找到(dao)諧振點后,手動(dong)按(an)電(dian)壓(ya)(ya)鈕(niu),光標到(dao)了輸出(chu)功(gong)率(lv)(lv),隨之按(an)上下(xia)鍵增(zeng)加(jia)(jia)輸出(chu)功(gong)率(lv)(lv),試(shi)(shi)驗(yan)電(dian)壓(ya)(ya)也逐步升高,當(dang)升到(dao)試(shi)(shi)驗(yan)電(dian)壓(ya)(ya)設定電(dian)壓(ya)(ya)值時(shi),裝置停止(zhi)加(jia)(jia)壓(ya)(ya),并有屏(ping)幕顯示提示和聲音(yin)提示;自(zi)動(dong)進入正在加(jia)(jia)壓(ya)(ya)試(shi)(shi)驗(yan)菜單項,并自(zi)動(dong)記錄試(shi)(shi)驗(yan)的加(jia)(jia)壓(ya)(ya)時(shi)間,當(dang)到(dao)達加(jia)(jia)壓(ya)(ya)時(shi)間設定時(shi)間時(shi),設備(bei)逐步降壓(ya)(ya)退出(chu)試(shi)(shi)驗(yan),完成本次試(shi)(shi)驗(yan),進入試(shi)(shi)驗(yan)結束(shu)菜單項。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

注(zhu)意(yi):在(zai)調(diao)(diao)節頻(pin)率(lv)調(diao)(diao)整鈕的(de)(de)過程(cheng)中,觸按左右鈕,可以改(gai)變頻(pin)率(lv)調(diao)(diao)節的(de)(de)速(su)度實(shi)現粗細調(diao)(diao)的(de)(de)切換(huan)(huan)。在(zai)調(diao)(diao)節電壓(ya)(ya)調(diao)(diao)整鈕的(de)(de)過程(cheng)中,向下觸按左右鈕,可以改(gai)變電壓(ya)(ya)的(de)(de)升(sheng)降的(de)(de)速(su)度實(shi)現粗細調(diao)(diao)的(de)(de)切換(huan)(huan)。觸按調(diao)(diao)頻(pin)、調(diao)(diao)壓(ya)(ya)鈕,實(shi)現調(diao)(diao)頻(pin)與調(diao)(diao)壓(ya)(ya)間的(de)(de)切換(huan)(huan)。

7、進(jin)入試驗記錄查(cha)詢(xun)(xun)菜單項,查(cha)詢(xun)(xun)以往和當(dang)前(qian)試驗數(shu)據。選擇(ze)(ze)上下鍵(jian)翻看前(qian)一(yi)組數(shu)據后(hou)一(yi)組數(shu)據;選擇(ze)(ze)左右鍵(jian)可(ke)選擇(ze)(ze)打印或刪除當(dang)前(qian)頁的內容。

125/456為(wei)試(shi)(shi)驗數(shu)(shu)據(ju)庫指(zhi)針(zhen),分(fen)子是(shi)(shi)試(shi)(shi)驗數(shu)(shu)據(ju)的(de)在數(shu)(shu)據(ju)庫的(de)順序數(shu)(shu),分(fen)母是(shi)(shi)當前(qian)的(de)數(shu)(shu)據(ju)總數(shu)(shu),*多可儲(chu)存999組試(shi)(shi)驗數(shu)(shu)據(ju)。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

8、裝(zhuang)置和(he)試(shi)驗(yan)狀態菜(cai)單提示:設(she)備(bei)的使用(yong)和(he)升壓(ya)和(he)耐壓(ya)試(shi)驗(yan)過程中,如果出現影響試(shi)驗(yan)設(she)備(bei)、被試(shi)驗(yan)設(she)備(bei)以及操(cao)作人的**情(qing)況,設(she)備(bei)可能出現自動保(bao)護轉(zhuan)臺,并在屏幕有相(xiang)應的提示。

不(bu)(bu)(bu)(bu)能(neng)諧振(zhen):如果諧振(zhen)點不(bu)(bu)(bu)(bu)在諧振(zhen)頻率設(she)置(zhi)的范圍內;系(xi)統連線不(bu)(bu)(bu)(bu)正確等現(xian)象,裝置(zhi)將(jiang)找不(bu)(bu)(bu)(bu)到諧振(zhen)點,這時裝置(zhi)和試驗狀態菜(cai)單中的不(bu)(bu)(bu)(bu)能(neng)諧振(zhen)項被(bei)反白并閃(shan)爍。

輸(shu)(shu)出(chu)保(bao)(bao)護(hu)(hu)(hu):如(ru)果裝置的(de)電源輸(shu)(shu)出(chu)電流大于輸(shu)(shu)出(chu)保(bao)(bao)護(hu)(hu)(hu)設(she)定的(de)電流值,裝置自動保(bao)(bao)護(hu)(hu)(hu),這時裝置和試驗狀(zhuang)態菜單中的(de)輸(shu)(shu)出(chu)保(bao)(bao)護(hu)(hu)(hu)項被(bei)反白并閃爍。

試驗(yan)中止:如果在試驗(yan)升壓或加壓過程(cheng)出現閃絡現象,裝置(zhi)自動保護(hu),這時裝置(zhi)和試驗(yan)狀態菜單中的(de)輸出保護(hu)項(xiang)被反白并閃爍(shuo)。

9、試驗幫助內(nei)容包括五(wu)大項分別為:1.版本(ben)信息(xi)2.接線示(shi)意(yi)3.使用(yong)說(shuo)明4.常見問(wen)題5.參考資料(liao).如常見問(wen)題FAQ分五(wu)幅(fu)畫面顯示(shi)、各種被(bei)試品電(dian)(dian)力電(dian)(dian)纜、變(bian)壓器、發電(dian)(dian)機電(dian)(dian)容參數的查詢:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

接線示意圖:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

10、設(she)備(bei)出(chu)廠參(can)(can)(can)數設(she)置(zhi)是生產(chan)廠家(jia)的(de)出(chu)廠設(she)置(zhi)參(can)(can)(can)術和校驗參(can)(can)(can)數,不適當的(de)設(she)置(zhi)和修(xiu)改(gai)(gai)會影響設(she)備(bei)性(xing)能和高壓試(shi)驗的(de)**性(xing),未(wei)經廠家(jia)授(shou)權密碼,無法修(xiu)改(gai)(gai)。

警告:正常試(shi)驗(yan)狀態(tai)下(xia),按(an)返回鍵即可中止試(shi)驗(yan)。中止或(huo)(huo)結束(shu)試(shi)驗(yan)后(hou),應分離刀閘切斷電源。在(zai)升壓(ya)或(huo)(huo)加壓(ya)過(guo)程中,非緊急(ji)情況,不要按(an)下(xia)急(ji)停鍵。

六、本說明書的專屬名詞的定義

自動試驗:高壓試驗全過(guo)程由主機(ji)按程序和預置參數(shu)自動完成。

自動(dong)調諧:調諧由主機(ji)按程序自動(dong)完(wan)成(cheng),升壓手動(dong)完(wan)成(cheng)。

手(shou)動試驗:尋找諧(xie)振點和(he)升壓(ya)均(jun)為手(shou)動,通過面(mian)板旋(xuan)鈕完成。

系統參(can)數(shu)設(she)(she)置(zhi)是指對設(she)(she)備(bei)部件參(can)數(shu)的設(she)(she)置(zhi)。

試驗參(can)(can)數設置是指對(dui)試驗過程參(can)(can)數的(de)設置。

試(shi)驗(yan)模式選(xuan)擇是(shi)指對試(shi)驗(yan)模式的(de)選(xuan)擇。

試驗(yan)結果(guo)查詢(xun)是指對試驗(yan)數據的查詢(xun)。

分壓器變比是指對分壓器的分壓比設(she)置。

電抗(kang)器電感是指對電抗(kang)器電抗(kang)值的設置。

激勵(li)變變比(bi)是(shi)指對勵(li)磁變壓器的變比(bi)設置。

設置電(dian)壓是高壓試驗時的(de)保護電(dian)壓設置。

試驗電(dian)壓是高壓試驗時的試驗電(dian)壓。

加壓時(shi)間是(shi)施加試驗電壓的(de)時(shi)間。

激勵(li)強度是指主(zhu)機電源輸出的大小。

輸出電(dian)流(liu)是主機(ji)電(dian)源(yuan)的輸出電(dian)流(liu)。

頻率(lv)范圍(wei)是(shi)試驗的(de)頻率(lv)范圍(wei)。

自(zi)動試驗模式是指試驗過(guo)程全(quan)部自(zi)動完成。

自(zi)動調諧模式是指自(zi)動尋找(zhao)諧振點(dian)后,手動加壓(ya)完(wan)成試驗。

手動試驗模(mo)式全部(bu)由人工完成試驗過(guo)程。

未接(jie)地(di)線主機電源(yuan)為接(jie)地(di)。

不能(neng)諧(xie)振未能(neng)找到諧(xie)振點。

輸出保(bao)護主機(ji)電(dian)(dian)源輸出電(dian)(dian)流(liu)(liu)大于整定(ding)電(dian)(dian)流(liu)(liu)。

試驗中止指在升壓(ya)或加壓(ya)過程裝置自動(dong)保(bao)護。

設(she)備(bei)出(chu)廠參(can)數設(she)置是廠家對(dui)設(she)備(bei)有關參(can)數的設(she)置。

確認鍵:確認當前(qian)操作。

返(fan)回(hui)鍵(jian):返(fan)回(hui)上**菜單。

七、變頻電源技術(shu)參數:

1.額定輸出容量:15kvA;

2.儀器電源:220v±10%  50Hz;

功率(lv)電(dian)源:380v±10%  50Hz;

3.額(e)定輸入電流(liu):39.5A;

4.額(e)定輸出電(dian)壓(ya):0-340v可調、單相、輸出電(dian)壓(ya)不(bu)穩(wen)定度0.05%;

5.額定輸出電流:44A;

6.頻率(lv)調節(jie)范圍:25~320Hz;

7.額定(ding)容量下(xia)連續運行為(wei)規定(ding)工作時間下(xia)*高溫(wen)升≤60K;

8.顯示以下參數:

a.經(jing)變頻輸出的(de)頻率、電壓、電流;

b.過壓保護電(dian)壓值,并可(ke)任(ren)意整(zheng)(zheng)定,當(dang)成(cheng)套裝置的輸出電(dian)壓值達到保護整(zheng)(zheng)定時,可(ke)自(zi)動切(qie)除成(cheng)套裝置;

c.過流保護(hu):當調頻電源的輸出電流達到保護(hu)整定值時,可自動(dong)切除成(cheng)套裝置(zhi);

d.擊(ji)穿(chuan)保護(hu):當高壓(ya)側(ce)發生對(dui)地閃絡(luo)時,可自(zi)動切除成套(tao)裝置(zhi),裝置(zhi)帶有(you)隔離裝置(zhi),可確保設備和人身不(bu)受損害;

e.具(ju)有全電(dian)壓(ya)(ya)輸出保護(hu),在調壓(ya)(ya)過程(cheng)中,一(yi)旦調壓(ya)(ya)失(shi)控,調頻電(dian)源立即閉鎖;

9.可(ke)實現以下操作:

a.頻(pin)率的調節,上(shang)升和(he)下(xia)降頻(pin)率調節分粗(cu)調和(he)細調兩種(zhong),并可自動(dong)尋找(zhao)試驗諧振(zhen)點,保證諧振(zhen)頻(pin)率在整個試驗過程中不發(fa)生漂(piao)移(yi);

b.帶有設(she)(she)置(zhi)電壓、設(she)(she)置(zhi)時(shi)間,電壓自動上升到設(she)(she)置(zhi)值而停止并自動計時(shi);

c.帶有各(ge)種(zhong)保護功能的整定(ding)按(an)鈕(niu),可(ke)在面板上對各(ge)種(zhong)保護值進(jin)行整定(ding);

d.帶有手動試驗(yan)功(gong)能和自(zi)動試驗(yan)功(gong)能;

e.帶有試(shi)驗數據打印功能。

八(ba)、勵磁變壓器(qi)技術參數(shu):

1.結構形(xing)式:干(gan)式;

2.額定容(rong)量(liang):15kVA;

3.輸入電壓:0~340V;

4.輸出電壓:四組并聯(lian)3.75KV;四組串聯(lian)15KV;二串二并7.5KV;

5.輸出電流:四(si)(si)組并聯4A;四(si)(si)組串聯1A;二(er)串二(er)并2A;

6.工(gong)作(zuo)頻率(lv)范(fan)圍:30~300Hz;

勵磁(ci)變壓器(qi)的接線端子,如圖所示:

1.輸出端(duan)尾—與(yu)接(jie)地端(duan)連接(jie)。

2.輸出(chu)端(duan)頭—與電抗器連接。

3.接(jie)地端—與變頻電源、分壓器及被試品(pin)共同接(jie)地。

4.輸(shu)入(ru)端(duan)—接調頻電源功率輸(shu)出(chu)端(duan)。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

九、諧(xie)振(zhen)電抗(kang)器技術參數:

額(e)定容量:55KVA;

額定電壓:55kV;

額定(ding)電流:1.5A;

電 感(gan) 量:160H;

品質(zhi)因數:Q≥30

采用環氧(yang)干式。

7.接線端了(le)如圖所示:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

a.高(gao)壓側接線端子(zi)—與被試(shi)品高(gao)壓端連接。

b.低壓側接(jie)線端(duan)子—與(yu)勵磁變輸出端(duan)連接(jie)。

c.多(duo)臺電(dian)抗器串聯時上節的(de)(de)低壓側與下節高壓側連接。諧(xie)振電(dian)抗器采用多(duo)臺串聯或并(bing)聯的(de)(de)連接方式。

8.額定容量下連續(xu)運行為規定工作時(shi)間下,電抗器對空氣的溫升不大于60K;

9.性能(neng)及特點:電(dian)抗器設計干(gan)式、環(huan)氧澆(jiao)鑄,電(dian)抗器可以(yi)自由方便疊裝(zhuang)。環(huan)氧樹脂絕緣筒外(wai)殼,具有足夠(gou)的(de)(de)電(dian)氣、機械(xie)強(qiang)度(du),必要(yao)的(de)(de)散(san)熱能(neng)力以(yi)及油熱脹冷縮的(de)(de)裕度(du)。外(wai)殼上下蓋板,顏色為橘紅(hong)色。

十、電容(rong)分壓器技(ji)術(shu)參數:

額定電(dian)壓:200kV;

工作(zuo)頻率:30~300Hz;

分壓比(bi):2000:1;

分壓比誤差:1%;

電容分壓器接線(xian)端子如圖所示(shi):

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

高壓(ya)(ya)端(duan)—與電抗器高壓(ya)(ya)側及被試品高壓(ya)(ya)側相連。

測(ce)量(liang)插座—采用專配(pei)的測(ce)量(liang)電(dian)纜(lan)與控制箱背板測(ce)量(liang)輸入端連接。

接地(di)(di)端(duan)—采用(yong)專配(pei)接地(di)(di)線按接線圖指示接地(di)(di)。

4.性(xing)能及(ji)特點(dian):

a.額定(ding)電壓下(xia)可連續運行2小時。

b.在30~300Hz范(fan)圍內(nei),其(qi)精(jing)度(du)和穩(wen)定度(du)保持不變。

c.在20℃溫度下電容分壓器介質損耗(hao)值≤0.0025

d.電容(rong)分壓器配有支撐底架,具有足夠的穩定性。

e.電壓測(ce)(ce)量(liang)(liang)通(tong)過專(zhuan)用測(ce)(ce)試引線(xian)引至調頻電源進行(xing)測(ce)(ce)量(liang)(liang)。


試(shi)驗接線圖:

110kv主變、GIS試(shi)驗接線

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

35kv電纜試驗接線圖

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

10kv電(dian)纜試驗接線圖(tu)

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

十二、設(she)備(bei)保(bao)存和(he)維護

1、存放于干燥、清潔場地,防止雨(yu)水、灰塵進入部件內部;

2、如若長期(qi)不使用(yong),正常(chang)天氣(qi)至少2個(ge)月應(ying)通(tong)電(dian)(dian)(dian)一次時間不少于半小時,雨季及潮(chao)濕期(qi)應(ying)每(mei)隔一個(ge)月通(tong)電(dian)(dian)(dian)一次,通(tong)電(dian)(dian)(dian)時間半小時,以(yi)驅除設備內的潮(chao)氣(qi)防止電(dian)(dian)(dian)子元器件的銹(xiu)蝕,影(ying)響正常(chang)使用(yong)。

3、定期檢查(cha)裝(zhuang)置各(ge)部件,確保各(ge)接頭緊(jin)固無(wu)松動;

4、更換打印紙(zhi),機(ji)器采用熱敏打印紙(zhi)并且(qie)是前換紙(zhi)式當需要(yao)換紙(zhi)時只要(yao)按POST鍵鈕(niu)打印紙(zhi)艙門就會打開(kai)可以將新打印紙(zhi)裝(zhuang)入;

十三、常見(jian)故障排除(chu)


故障現象

發 生 原 因

排(pai) 除 方(fang) 法

找不到諧振點(dian)


接線有誤(wu)。

輸出開關未開,;

3、做GIS時PT二(er)次回路未打開;

4、試品Q值太低;

5、起始激勵功率(lv)太低;

6、試驗回(hui)路有短路現(xian)象;

7、找(zhao)頻范圍不對。

退出(chu)試(shi)驗(yan)狀(zhuang)態,合上輸出(chu)開(kai)關,檢查接線;打開(kai)PT二次回路;

調高起始(shi)功率(∠30%);


用(yong)兆歐表測量試品絕(jue)緣

重新設置找頻范圍

諧振后(hou),電壓升(sheng)不(bu)上去

1、試品Q值太低;

2、激勵電(dian)壓不夠;

3、電抗器(qi)底(di)部有(you)鐵磁(ci)物體;

4、3次諧(xie)波諧(xie)振(zhen)。

檢查試品;

改(gai)變激勵(li)變壓器繞組(zu)接法,提(ti)高勵(li)磁電(dian)壓

絕(jue)緣(yuan)筒架高電抗器或離開鐵磁(ci)物體。

主機自動(dong)復位


供電電源容量不夠;

電源(yuan)引線(xian)(xian)過(guo)長或線(xian)(xian)徑過(guo)小;

接頭處接觸**;

供電(dian)電(dian)壓(ya)波動;

按鍵死接觸。

增加供電電源容量(liang);

換較粗導(dao)線,減小導(dao)線長度;

檢查接頭;

減(jian)小供電(dian)電(dian)壓波動。

開機后線路跳閘

線路漏(lou)電(dian)保護器較為(wei)敏(min)感;

空氣開關(guan)容量不夠(gou)。

跨(kua)過(guo)漏電保(bao)護器或(huo)空氣開關的(de)接線;

改換較大容量的空氣開關。

電壓跌落

試品放電(dian)或擊穿

檢查(cha)試(shi)品

輸出短路

電流(liu)超過本機限流(liu)值。

檢(jian)查接線和試品。

試品電壓不準(zhun)

分壓(ya)比設置錯誤或分壓(ya)器信號傳輸有問題。

重設分壓比或檢查分壓器接(jie)線(xian)。

電(dian)壓閃變

試驗電壓劇烈波動,變(bian)化率超過(guo)本機限定(ding)值。

檢查供電(dian)電(dian)源電(dian)壓穩定(ding)性或試品(pin)參數(shu)的變化。

回路無電流(liu)


檢查接線和試品。

未接好地線(xian)


檢查(cha)接(jie)地線和地樁,按說(shuo)明(ming)書要求連接(jie)。

試(shi)品過電壓

手動升壓太快或(huo)失控。

改變調壓(ya)步距(ju)或改用自動升壓(ya) 。

系統不(bu)諧振

接線(xian)有誤(wu)或試品Q值(zhi)太低。

檢查接線和試品


十四(si)、常用設備資料參考

交聯聚乙烯(xi)電纜單位長度(du)電容量

電纜導體(ti)截面積(平方毫米)

電        容   (μ/km)

YJV、YJLV

YJV、YJLV

YJV、YJV、YJLV

YJV、YJLV

YJV、YJLV

6/6kV、6/10kV

8.7/10kV、8.7/15kV

12/35kV

21/35kV

26/35kV

1×35

0.212

0.173

0.152



1×50

0.237

0.192

0.166

0.118

0.114

1×70

0.270

0.217

0.187

0.131

0.125

1×95

0.301

0.240

0.206

0.143

0.135

1×120

0.327

0.261

0.223

0.153

0.143

1×150

0.358

0.284

0.241

0.164

0.153

1×185

0.388

0.307

0.267

0.180

0.163

1×240

0.430

0.339

0.291

0.194

0.176

1×300

0.472

0.370

0.319

0.211

0.190

1×400

0.531

0.418

0.352

0.231

0.209

1×500

0.603

0.438

0.388

0.254

0.232

1×600

0.667

0.470

0.416

0.287

0.256

2、交聯(lian)聚乙(yi)烯電(dian)纜單位長度電(dian)容量

電(dian)纜導體(ti)截面積(ji)(平方毫米)

電   &nbsp;    容   (μF/km)

YJV、YJLV

YJV、YJLV

YJV、YJV、YJLV

YJV、YJLV

YJV、YJLV

6/6kV、6/10kV

8.7/10kV、8.7/15kV

12/35kV

21/35kV

26/35kV

3×35

0.212

0.173

0.152



3×50

0.237

0.192

0.166

0.118

0.114

3×70

0.270

0.217

0.187

0.131

0.125

3×95

0.301

0.240

0.206

0.143

0.135

3×120

0.327

0.261

0.223

0.153

0.143

3×150

0.358

0.284

0.241

0.164

0.153

3×185

0.388

0.307

0.267

0.180

0.163

3×240

0.430

0.339

0.291

0.194

0.176

3×300

0.472

0.370

0.319

0.211

0.190

3×400

0.531

0.418

0.352

0.231

0.209

3×500

0.603

0.438

0.388

0.254

0.232

3×600

0.667

0.470

0.416

0.287

0.256

3、交聯(lian)聚乙烯電(dian)纜單位長度電(dian)容(rong)量

電(dian)纜導(dao)體截面積(ji)(平方毫(hao)米)

電      &nbsp; 容   (μF/km)

YJV、YJLV

YJV、YJLV

64/110kV

128/220kV

3×240

0.129


3×300

0.139


3×400

0.156

0.118

3×500

0.169

0.124

3×630

0.188

0.138

3×800

0.214

0.155

3×1000

0.231

0.172

3×1200

0.242

0.179

3×1400

0.259

0.190

3×1600

0.273

0.198

3×1800

0.284

0.297

3×2000

0.296

0.215

3×2200


0.221

3×2500


0.232

4、60kV級全絕(jue)緣(yuan)變壓器(qi)的電容(pF)


類 型(xing)

變  壓(ya) &nbsp;器  容  量(liang)     kVA

630

2000

3150

6300

8000

1600

高壓-地

2700

4100

4600

5900

7000

8200

低壓-地

4200

6600

7900

10000

11000

15300

對于(yu)表中(zhong)(zhong)沒有的(de)(de)產(chan)品(pin),可根據(ju)表中(zhong)(zhong)的(de)(de)上、下容(rong)量近似地估算。同(tong)容(rong)量的(de)(de)雙繞(rao)組變壓器(qi),其繞(rao)組電容(rong)要比三繞(rao)組產(chan)品(pin)小。

5、110kV級(ji)中性點分(fen)級(ji)絕緣變壓器的電容(pF)


類  型(xing)

變 壓(ya) 器 容 量kVA

50000

31500

20000

10000

5600

高(gao)壓-中壓、低(di)壓、地

14200

11400

8700

6150

4200

中壓(ya)-高壓(ya)、低壓(ya)、地

24800

11800

13200

9600

-

低壓(ya)-高壓(ya)、中壓(ya)、地

19300

19300

12000

9400

6800

6、220kV級中性點非全級絕緣部(bu)分變壓器的電容(pF)


試 品 型 號

SEPSL-63000

SSPSL-120000

SSPSL-240000

類  型

高壓(ya)-中(zhong)壓(ya)、低(di)壓(ya)及地

12100

13500

17050

中壓(ya)-高壓(ya)、低壓(ya)及地

18500

19700

23260

低壓(ya)-高壓(ya)、中壓(ya)及地

18200

23600

29940

試 品 型 號(hao)

SFPL-240000

SFP-360000

SFPSZL-120000

類  型

高壓(ya)-中(zhong)壓(ya)、低壓(ya)及地

32230

33910

38020

中壓(ya)-高壓(ya)、低壓(ya)及地

-

-

23260

低(di)壓(ya)(ya)-高壓(ya)(ya)、中(zhong)壓(ya)(ya)及(ji)地(di)

22470

23790

22160

7、油(you)浸式電力變(bian)壓(ya)器(qi)交(jiao)流試(shi)驗電壓(ya)

額定電壓(ya)

(k V)

*高工作

電壓(k V)

線端交流試驗電壓(ya)值(kV)

中性點交流試驗電壓值(kV)

全部更換(huan)繞組

部分更換繞(rao)組或交接

全部更換(huan)繞組

部分更換繞組或交(jiao)接(jie)

<1

≤1

3

2.5

3

2.5

3

3.5

18

15

18

15

6

6.9

25

21

25

21

10

11.5

35

30

35

30

15

17.5

45

38

45

38

20

23.0

55

47

55

47

35

40.5

85

72

85

72

110

126.0

200

170(195)

95

80

220

252.0

360

306

85

72

395

336

(200)

(170)

500

550.0

630

536

85

72

680

578

140

120


8、部分型(xing)號(hao)發電機定子(zi)繞組(zu)的單相對地電容量(liang)


類別

發      電(dian)   &nbsp;  機(ji)

型號

生產廠(chang)家

額定容量(MW)

額定(ding)電壓(kV)

相電容(mF)


電(dian)

QFS-125-2

上(shang)海電(dian)機(ji)廠

125

13.8

0.08-0.12

QFSN-200-2

哈爾濱(bin)電(dian)機廠(chang)

200

15.75

0.19-0.21

QFQS-200-2

東方電(dian)機廠

200

15.75

0.1928-0.21

QFQS-200-2

北(bei)京重型(xing)電(dian)機廠(chang)

200

15.75

0.18-0.19

QFS-300-2

上海(hai)電機廠

300

18.0

0.16-0.20

QFSN-300-2

上(shang)海電機廠

300

18.0

0.18-0.20

ATB-2

美(mei)國GE公(gong)司(si)

352

23.0

0.268(設計值)

TBB-320-2

(前蘇聯)

320

20.0

0.31

2-105×234

美(mei)國西屋(wu)公司

600

20.0

0.2(工廠(chang)試驗值)

50WT23E-138

ABB

600

22.0

0.253(設計值)

水(shui) 發

力 電



72.5 - 85

10.5

0.694



300

15.75

1.7-2.5



400

18.0

2-2.5

9、同步發電(dian)機定子繞組交流試驗(yan)電(dian)壓



1

全部更(geng)換(huan)定(ding)子繞組并(bing)修(xiu)好后的試驗(yan)電壓

容量kW或kVA

小于10000

10000及以上

額定(ding)電壓(ya)Un (V)

36以上

6000以下

6000~18000

18000以(yi)上

試(shi)驗電壓V

2Un+1000但(dan)*低(di)為1500

2.5Un

2Un

+3000

按(an)專門協議


2

大修(xiu)前或局部更換(huan)定(ding)子繞組并(bing)修(xiu)好(hao)后的試驗電壓

運(yun)行20年(nian)及以(yi)下(xia)者

1.5 Un

運行20年以上與架空線路(lu)直(zhi)接(jie)連接(jie)者

1.5 Un

運(yun)行20年以上不與架空線路直接連接者(zhe)

(1.3~1.5)Un

十五、設備(bei)成套(tao)性:

變(bian)頻電源(yuan)                             1臺

勵磁變壓器            &nbsp;     &nbsp;        1臺

電抗器                  &nbsp;           ; 4臺

電容分壓器(qi)                           1臺

附件(jian)及測試(shi)線(xian)                    &nbsp;    1套

支架(jia)              15KV   &nbsp;           1只

均(jun)壓罩            200KV            &nbsp; 2只

絕緣底板(ban)            &nbsp;                2塊

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

一(yi)、產品(pin)概述

YDQC系列輕(qing)型交直(zhi)流(liu)高(gao)(gao)壓(ya)(ya)試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)器是(shi)在同類產(chan)品(pin)YDJ(G)型高(gao)(gao)壓(ya)(ya)試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)器的基礎上,按(an)試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)器國家(jia)標準ZBK41006—89要求,經改進后生產(chan)的一種新型產(chan)品(pin),本系列產(chan)品(pin)具有體積小、重(zhong)量(liang)輕(qing)、結(jie)構緊湊、功能(neng)齊全、使用方便等特點。實(shi)用于(yu)電力、工(gong)礦(kuang)、科(ke)研等部門(men),對各(ge)種高(gao)(gao)壓(ya)(ya)電氣(qi)設備、電氣(qi)元件、絕緣材(cai)料進行(xing)工(gong)頻耐壓(ya)(ya)試(shi)驗(yan)和直(zhi)流(liu)泄漏(lou)試(shi)驗(yan),是(shi)高(gao)(gao)壓(ya)(ya)試(shi)驗(yan)中必不可少的儀器。

二、產(chan)品結(jie)構

YDQC系列輕(qing)型高(gao)壓試(shi)驗變壓器(qi)鐵芯(xin)為單框式(shi)(shi)。線(xian)圈采(cai)用(yong)同(tong)芯(xin)圓筒多層塔式(shi)(shi)結(jie)(jie)構(gou),初級(ji)低(di)壓繞組(zu)(zu)繞在鐵芯(xin)上,次級(ji)高(gao)壓繞組(zu)(zu)繞在低(di)壓繞組(zu)(zu)外(wai)側,這種(zhong)同(tong)軸布(bu)置減少了繞組(zu)(zu)間(jian)的(de)藕合(he)損(sun)耗。高(gao)壓硅(gui)堆用(yong)特殊工藝(yi)封裝(zhuang)在套管內,產品的(de)外(wai)殼(ke)制成(cheng)與器(qi)芯(xin)配合(he)較佳的(de)八角形結(jie)(jie)構(gou),整體外(wai)型美觀大(da)方。其內外(wai)部結(jie)(jie)構(gou)見(jian)圖(tu)1。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

1-均壓(ya)(ya)(ya)(ya)球;2-硅堆短路桿;3-高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)套管;4-油(you)閥;5-殼(ke)體(ti);6、7-調整(zheng)電壓(ya)(ya)(ya)(ya)輸入a、x端(duan)子(zi);8、9-儀表(biao)測量E、F端(duan)子(zi);10-高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)尾(wei)X端(duan)子(zi);11-變壓(ya)(ya)(ya)(ya)器外殼(ke)接地端(duan);12-高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)輸出A端(duan)子(zi);13-高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)整(zheng)流硅堆;14-內(nei)部均壓(ya)(ya)(ya)(ya)環;15-變壓(ya)(ya)(ya)(ya)器鐵芯;16-初級(ji)低壓(ya)(ya)(ya)(ya)繞組;17-測量儀表(biao)繞組;18-二(er)次級(ji)高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)繞組;19-變壓(ya)(ya)(ya)(ya)器油(you)。

三、工作原理

YDQC系列(lie)輕(qing)型高壓(ya)(ya)試驗變壓(ya)(ya)器(qi)為(wei)單相變壓(ya)(ya)器(qi),聯結組(zu)標(biao)號II。單臺(tai)高壓(ya)(ya)試驗變壓(ya)(ya)器(qi)的(de)工作過程,用交流220V(10KVA以上(shang)為(wei)380V)電(dian)(dian)(dian)(dian)壓(ya)(ya)接(jie)入電(dian)(dian)(dian)(dian)源(yuan)(yuan)控制箱(xiang)(臺(tai)),經電(dian)(dian)(dian)(dian)源(yuan)(yuan)控制箱(xiang)(臺(tai))內自(zi)藕調壓(ya)(ya)器(qi)(50KVA以上(shang)調壓(ya)(ya)器(qi)外附)調節0~200V(10KVA以上(shang)0~400V)電(dian)(dian)(dian)(dian)壓(ya)(ya)至試驗變壓(ya)(ya)器(qi)的(de)初(chu)級繞組(zu),根據電(dian)(dian)(dian)(dian)磁感應原理(li),在試驗變壓(ya)(ya)器(qi)高壓(ya)(ya)繞組(zu)可獲得試驗所需(xu)的(de)高電(dian)(dian)(dian)(dian)壓(ya)(ya)。其工作原理(li)圖見圖2所示。

1、單臺YDQC高壓試驗變壓器工作原理示(shi)意(yi)圖

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

在(zai)試驗變壓器中(zhong):a、x為低(di)壓輸入端;A、X 為高壓輸出端;E、F為儀表測量端。

2、單臺交直流兩用型高壓試驗變壓器工作原理見圖3。圖中所示:高壓套管內裝有高壓硅堆,串接在高壓回路中作高壓整流,以獲得直流高電壓。當用一短路桿將高壓硅堆短接時,可獲得交流高電壓,其狀態為交流輸出;反之在抽出短路桿時,其狀態為直流輸出。
3、三臺高壓試驗變壓器串激獲得更高電壓原理見圖4,串激高壓試驗變壓器有很大的優越性,因為整個試驗裝置由多個單臺串激式試驗變壓器組成,單臺試驗變壓器有著體積小、重量輕、便于運輸的特點,它既可以串接成高出幾倍的單臺試驗變壓器輸出電壓組合使用,又可以分開單獨使用。整套試驗裝置投資小、經濟實惠。圖3所示:在三臺串激式試驗變壓器串激使用中,單臺試驗變壓器B1、B2、B3的輸出電壓都是U,**、二級的試驗變壓器內部都有一個激磁繞組,分別為A1、C1 和A2、C2。當控制電壓加在第**試驗變壓器B1的初級繞組a1、x1上,激磁繞組A1、C1給予試驗變壓器B2初級繞組供電,**級試驗變壓器B2的激磁繞組A2、C2給試驗變壓器B3的初級繞組供電。由于第**試驗變壓器B1的高壓尾及殼體接地,**、三級的試驗變壓器B2和B3對地有絕緣支架的隔離,這樣試驗變壓器B1、B2、B3對地輸出電壓分別為1U、2U、3U。

B1、B2、B3- 串(chuan)激(ji)式高(gao)壓變壓器;1U、2U、3U-各(ge)級對地電壓;

PV- 高壓示(shi)值表(KV); ZJ1、ZJ2-絕緣支架(jia)。

四、使用(yong)方法及(ji)注意事項

1、YDQC高壓(ya)(ya)(ya)試(shi)(shi)驗變壓(ya)(ya)(ya)器(qi)做工頻耐壓(ya)(ya)(ya)試(shi)(shi)驗使用接線(xian)方法見圖5。做工頻耐壓(ya)(ya)(ya)試(shi)(shi)驗前,先根(gen)據試(shi)(shi)驗變壓(ya)(ya)(ya)器(qi)的(de)額(e)定容(rong)量選擇好限(xian)流(liu)電(dian)阻,(水電(dian)阻)的(de)阻值(zhi),再根(gen)據被試(shi)(shi)品(pin)需加(jia)的(de)高壓(ya)(ya)(ya)電(dian)壓(ya)(ya)(ya)值(zhi)調整好放(fang)電(dian)球隙的(de)球間(jian)距,為了(le)提(ti)高對被試(shi)(shi)品(pin)施加(jia)電(dian)壓(ya)(ya)(ya)的(de)測量精度,應在高壓(ya)(ya)(ya)側接入FRC阻容(rong)分壓(ya)(ya)(ya)器(qi)來測量電(dian)壓(ya)(ya)(ya)。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

R1、R2- 限流(liu)電阻; Qx- 放電球隙; ;Zx- 被試(shi)品;

FRC- 阻容分壓器; V- 分壓器高壓表。 
按照圖4、結合圖2所進行的工頻耐壓試驗接好工作線路,試驗變壓器的高壓繞阻的X端(高壓尾)、儀表測量繞組的F端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
用三臺試驗變壓器串激做工頻耐壓試驗時、**、三級試驗變壓器的初級繞組X端,儀表測量繞組的F端,以及高壓繞組的X端(高壓尾)均接本級試驗變壓器的外殼,**、三級試驗變壓器的主體必須放置在絕緣支架上。除第**以外、**、三級試驗變壓器的主體不要接地線。其接線方式見圖3所示。
接電源前,電源控制箱(臺)的調壓器必須調到零位。接通電源后,綠色指示燈亮,按一下啟動按鈕,紅色指示燈亮,表示試驗變壓器已接通控制電源,開始升壓。
從零位開始按順時針方向勻速旋轉調壓器手輪升壓。(升壓方式有:快速升壓法,即20S逐級升壓法,慢速升壓法,即60S逐級升壓法,極慢速升壓法供選用)電壓從零開始按選定的升壓速度升到您所需額定試驗電壓的75%后,再以每秒2%額定試驗電壓的速度升到您所需試驗電壓,并密切注意測量儀表的指示以及被試品的情況,被試品施加電壓的時間到后。應在數秒內勻速將調壓器返回,高壓降至1/3試驗電壓以下,按一下停止按鈕,高壓、低壓輸出停止,然后切斷電源線,試驗完畢。

工頻(pin)耐壓(ya)試驗操作過程注意事項

1、試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
2、被試品主要部位應**干凈,保持**干燥,以免損壞被試品和帶來試驗數值的誤差。
3、對大型設備的試驗,一般都應先進行試驗變壓器的空升試驗,即不接試品時升壓至試驗電壓,以便校對好儀表的指示精度,調整好放電球隙的球間距。
4、做耐壓試驗時升壓速度不能過快,并防止突然加壓,例如調壓器不在零位的突然合閘,也不能突然斷電,一般應在調壓器降至零位時分閘。
5、在升壓或耐壓試驗過程中,如發現下列不正常情況,1 電壓、電流表指針擺動很大,2 被試品發出不正常響聲,3 發現絕緣有燒焦或冒煙現象,應立即降壓,切斷電源,停止試驗并查明原因。
6、使用本產品做高壓試驗時,除熟悉本說明書外,還必須嚴格執行國家有關標準和操作規程。

2、YDQ交直(zhi)流(liu)(liu)兩(liang)用高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)試(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)器(qi)做直(zhi)流(liu)(liu)耐壓(ya)(ya)(ya)(ya)和泄漏試(shi)驗(yan)(yan)使用接線方法(fa)見圖(tu)5。由于是交直(zhi)流(liu)(liu)兩(liang)用高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)試(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)器(qi),應把(ba)高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)硅堆短路桿從套管中(zhong)抽出(chu),使試(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)器(qi)為(wei)直(zhi)流(liu)(liu)輸(shu)出(chu)狀(zhuang)態。做直(zhi)流(liu)(liu)泄漏試(shi)驗(yan)(yan)前,先根(gen)據泄漏試(shi)驗(yan)(yan)中(zhong)輸(shu)出(chu)端(duan)斷路電(dian)(dian)流(liu)(liu)不超過高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)硅堆的(de)(de)(de)*大整(zheng)流(liu)(liu)為(wei)宜,選擇好限流(liu)(liu)電(dian)(dian)阻(zu)(水(shui)電(dian)(dian)阻(zu))的(de)(de)(de)阻(zu)值,再根(gen)據被(bei)(bei)試(shi)品(pin)對直(zhi)流(liu)(liu)高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)波形的(de)(de)(de)要求(qiu)選擇好高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)濾波電(dian)(dian)容(rong)的(de)(de)(de)電(dian)(dian)容(rong)值。為(wei)了提高(gao)(gao)(gao)對被(bei)(bei)試(shi)品(pin)施加電(dian)(dian)壓(ya)(ya)(ya)(ya)的(de)(de)(de)測(ce)量(liang)精度,應在高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)側接入(ru)FRC阻(zu)容(rong)分壓(ya)(ya)(ya)(ya)器(qi)來(lai)測(ce)量(liang)電(dian)(dian)壓(ya)(ya)(ya)(ya)。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

R- 限流電(dian)阻; C- 高(gao)壓(ya)濾波電(dian)容(rong); Zx- 被試(shi)品(pin); G-&nbsp;硅堆(dui)短路桿(gan);

FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高壓整流硅堆。
按照圖5、結合圖3所進行的直流泄漏試驗接好工作線路。試驗變壓器的高壓繞組的X端(高壓尾)、儀表測量繞組的F&nbsp;端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

接(jie)電(dian)(dian)(dian)源前、電(dian)(dian)(dian)源控制箱(臺)的調(diao)(diao)壓(ya)器必須調(diao)(diao)到(dao)零位。接(jie)通電(dian)(dian)(dian)源后(hou),綠色(se)指示燈亮,按(an)一下啟動(dong)按(an)鈕,紅色(se)指示燈亮,表示試驗(yan)變(bian)壓(ya)器已接(jie)通控制電(dian)(dian)(dian)源,開(kai)始升壓(ya)。

從零位開(kai)始按順(shun)時(shi)針方(fang)向勻(yun)速(su)旋轉(zhuan)調壓(ya)(ya)(ya)(ya)器手輪(lun)升(sheng)壓(ya)(ya)(ya)(ya)。(升(sheng)壓(ya)(ya)(ya)(ya)方(fang)式有:快速(su)升(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa)(fa)即(ji)20S逐(zhu)級(ji)(ji)升(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa)(fa);慢(man)速(su)升(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa)(fa),即(ji)60S逐(zhu)級(ji)(ji)升(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa)(fa);級(ji)(ji)慢(man)速(su)升(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa)(fa)供(gong)選用)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)從零開(kai)始按選定(ding)(ding)的(de)升(sheng)壓(ya)(ya)(ya)(ya)速(su)度升(sheng)到您(nin)所需額定(ding)(ding)試(shi)(shi)驗電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)或額定(ding)(ding)直(zhi)流(liu)(liu)電(dian)(dian)(dian)流(liu)(liu)下(xia)的(de)參考電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)。試(shi)(shi)驗中(zhong)應(ying)嚴密注意直(zhi)流(liu)(liu)高(gao)(gao)壓(ya)(ya)(ya)(ya)表(biao)、泄漏電(dian)(dian)(dian)流(liu)(liu)表(biao)指示以及(ji)被(bei)試(shi)(shi)品(pin)的(de)情(qing)況(kuang)。試(shi)(shi)驗完畢后,應(ying)訊速(su)均勻(yun)將高(gao)(gao)壓(ya)(ya)(ya)(ya)降至零位,按一下(xia)停(ting)止按鈕,高(gao)(gao)壓(ya)(ya)(ya)(ya)、低壓(ya)(ya)(ya)(ya)輸出(chu)停(ting)止,然后切斷電(dian)(dian)(dian)源。此時(shi)應(ying)用直(zhi)流(liu)(liu)高(gao)(gao)壓(ya)(ya)(ya)(ya)放(fang)**給(gei)被(bei)試(shi)(shi)品(pin)及(ji)試(shi)(shi)驗裝置本身(shen)充(chong)分(fen)放(fang)電(dian)(dian)(dian)。

直流泄漏(lou)試驗(yan)操作過程(cheng)注意(yi)事項(xiang)

(1)試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
(2)被試品做試驗前,應拆除所有對外連線,并充分放電,主要部位應**干凈,保持**干燥,以免損壞被試品及帶來試驗數值的誤差。
(3)對于大容量試品(電容器、超長電纜等)試驗時應緩慢升壓,防止被試品的充電電流過大而燒壞微安表,必要時應分級加壓分別讀取各電壓下微安表的穩定讀數。
(4)試驗過程中,應嚴密監視被試品、微安表及試驗裝置等,一旦發生閃爍、擊穿等現象應立即降壓,切斷電源,并查明原因。

五、配套選購產(chan)品

下列產品僅供選擇,購買時需另行計價。
1.KZX系列電源控制箱 容量:1KVA-5KVA、輸入電壓:220V
2.KZT系列電源控制臺 容量:10KVA~300KVA輸入電壓:220V或380V
3.數字微安表:SWB-II
4.高壓濾波電容: 0.01MF、40 ~ 100KV
5.高壓直流放**: FBR— 70、140、210KV
6.放電球隙: Q—50、100、150、200、250、500
7.標準試油杯: 400ml
8.折疊式手推車: 150、300型
9.絕緣支架: 50、100、200、300、400KV
10.阻容分壓器: FRC —50、100、150、200KV
11.高壓硅堆: 2DL—150、300、450KV
12.水 電 阻: 50、100

六、主要試驗設備(bei)的選(xuan)擇

1、試驗變壓器
其高壓側額定電壓應不小于被試品的*高試驗電壓,額定電流不小于被試品的*大電容電流。被試品的電容電流和試驗變壓器所需容量計算式為:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

被(bei)試品(pin)電(dian)(dian)容量(liang)Cx可(ke)由交流電(dian)(dian)橋(qiao)測出。常用的被(bei)試品(pin)電(dian)(dian)容量(liang)按表1選取。

幾種常用被試品的(de)電容量(pF) 表1

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

2、調(diao)壓設備

(1)自藕調壓器。其調壓范圍廣、功率損耗小、波形畸變小、選擇這種調壓方式為*好。自藕調壓器的容量按0.75 ~ 1倍的試驗變壓器的容量選擇,適用于容量為100KVA以下的試驗變壓器的調壓。
(2)感應調壓器。其調壓范圍大,波形畸形小、但結構復雜、價格較貴,當試驗變壓器的容量較大時(如100KVA以上)使用。
3、限流電阻
限流電阻的作用是,當被試品擊穿時,限制斷路電流,從而保護試驗變壓器,防止故障的擴大。其數值以*高試驗電壓為準,按0.5 ~ 1 Ω / V(有效值)選擇,限流電阻可用水電阻。注意水不能充滿玻璃管,應留有余地,以防爆裂。
4、放電球隙
放電球隙的布置方式有垂直和水平兩種,球隙間距S和球的直徑D的關系應保護在0.05D ≤S ≤0.5D范圍內,球隙上的水電阻阻值一般按0.1 ~ 1Ω/V選取,設置放電球隙的目的是為了對重要的被試品起保護作用,可以將由于誤操作或被試品擊穿引起的過電壓限制在允許的范圍內。

七、試驗(yan)變壓器技術指(zhi)示

型號

容量

高壓電壓

高壓(ya)電(dian)流

低壓(ya)輸入

變比(bi)

溫升℃

(KVA)

(KV)

(mA)

電壓(V)

電(dian)流(A)

高/儀

30分鐘

YDQC-1.5/50

1.5

50

30

200

7.5

500

10

YDQC-3/50

3

50

60

200

15

500

10

YDQC-5/50

5

50

100

200

25

500

10

YDQC-10/50

10

50

200

200

50

500

10

YDQC-15/50

15

50

300

200

75

500

10

YDQC-20/50

20

50

400

380

53

500

10

YDQC-30/50

30

50

600

380

79

500

10

YDQC-50/50

50

50

1000

380

12

500

10

YDQC-5/100

5

100

50

200

25

1000

10

YDQC-10/100

10

100

100

200

50

1000

10

YDQC-20/100

20

100

200

400

50

1000

10

YDQC-30/100

30

100

300

400

75

1000

10

YDQC-50/100

50

100

500

400

125

1000

10

YDQC-20/150

20

150

133

400

50

1500

10

YDQC-30/150

30

150

200

400

75

1500

10

YDQC-50/150

50

150

333

400

125

1500

10

YDQC-100/150

100

150

667

400

250

1500

10

YDQC-50/200

50

200

250

400

125

2000

10

YDQC-100/200

100

200

500

400

250

2000

10

YDQC-150/200

150

200

750

400

375

2000

10

YDQC-200/200

200

200

1000

400

500

2000

10

YDQC-300/200

300

200

1500

400

600

2000

10

YDQC-50/300

50

300

170

400

125

3000

10

YDQC-100/300

100

300

333

400

250

3000

10

YDQC-150/300

150

300

500

400

375

3000

10

YDQC-200/300

200

300

667

400

500

3000

10

YDQC-300/300

300

300

3000

500

600

3000

10

1、使用環境條件
環境溫度不高于+40℃、不低于—20℃;空氣相對濕度不大于90%;海拔高度不超過2000米;
2、工作電壓
電源控制箱(臺)輸入電壓為工頻220V或380V、相對誤差不超過±10%;(具體使用電壓根據用戶所定試驗變壓器規格選取)
八、隨貨文件

YDQC 系列試驗變壓器產品說明書 1份
產品出廠試驗報告 1份
產品合格證 1份
裝箱單 1份

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

一(yi)、概述

YDQ系列高(gao)壓(ya)(ya)試(shi)驗(yan)變(bian)壓(ya)(ya)器(qi)是(shi)(shi)根據《試(shi)驗(yan)變(bian)壓(ya)(ya)器(qi)》標準,在(zai)油(you)浸式試(shi)驗(yan)變(bian)壓(ya)(ya)器(qi)的(de)(de)(de)基(ji)礎(chu)上而設計生產的(de)(de)(de)。SF6氣(qi)(qi)體(ti)具有良好(hao)的(de)(de)(de)電(dian)(dian)氣(qi)(qi)絕緣(yuan)(yuan)(yuan)性能及優異的(de)(de)(de)滅弧性能,其耐壓(ya)(ya)強(qiang)度為同一(yi)壓(ya)(ya)力下(xia)氮氣(qi)(qi)的(de)(de)(de)2.5倍,擊(ji)穿(chuan)電(dian)(dian)壓(ya)(ya)的(de)(de)(de)空氣(qi)(qi)的(de)(de)(de)2.5倍。在(zai)0.25MPa下(xia)與油(you)的(de)(de)(de)擊(ji)穿(chuan)電(dian)(dian)壓(ya)(ya)相(xiang)等,在(zai)0.45MPa壓(ya)(ya)力下(xia)是(shi)(shi)油(you)的(de)(de)(de)擊(ji)穿(chuan)電(dian)(dian)壓(ya)(ya)的(de)(de)(de)2倍,是(shi)(shi)一(yi)種(zhong)優于油(you)的(de)(de)(de)新一(yi)代超高(gao)壓(ya)(ya)絕緣(yuan)(yuan)(yuan)介(jie)質材(cai)料。該(gai)(gai)產品(pin)技術要求(qiu)完(wan)全符合《ZBK-41006-89》標準,它是(shi)(shi)油(you)浸式輕(qing)(qing)型(xing)試(shi)驗(yan)變(bian)壓(ya)(ya)器(qi)的(de)(de)(de)換代產品(pin)。該(gai)(gai)產品(pin)具有體(ti)積小、重(zhong)量輕(qing)(qing)、不受氣(qi)(qi)候變(bian)化影響、電(dian)(dian)暈(yun)小、現場搬運無需靜止可(ke)使(shi)用(yong),使(shi)用(yong)壽命長、免維修等特點。適用(yong)于電(dian)(dian)力系統、工(gong)礦企業、科研部門等對各種(zhong)高(gao)壓(ya)(ya)電(dian)(dian)氣(qi)(qi)設備、電(dian)(dian)氣(qi)(qi)元件(jian)、絕緣(yuan)(yuan)(yuan)材(cai)料進行工(gong)頻(pin)或直(zhi)流高(gao)壓(ya)(ya)下(xia)的(de)(de)(de)絕緣(yuan)(yuan)(yuan)強(qiang)度試(shi)驗(yan)。

二、產品(pin)結構

YDQ系列高壓試驗變壓器采(cai)用(yong)單框芯(xin)(xin)式鐵(tie)芯(xin)(xin)結(jie)構,初級繞組(zu)繞在(zai)鐵(tie)芯(xin)(xin)上,高壓繞組(zu)在(zai)外,這種同軸布置減少(shao)了漏磁(ci)通,因而(er)增大了繞組(zu)間的(de)耦合。產品(pin)的(de)外殼(ke)為(wei)圓柱灌式容器結(jie)構,能耐受0.8MPa以上壓力(li)。其結(jie)構見(jian)圖1:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

三、工作原(yuan)理

YDQ系(xi)列高(gao)(gao)壓(ya)試(shi)驗(yan)(yan)變(bian)(bian)壓(ya)器(qi)(qi)為(wei)單(dan)相變(bian)(bian)壓(ya)器(qi)(qi),聯結(jie)組標號Ⅰ.Ⅰ. 用工頻220V(10kVA以上為(wei)380V)電源接(jie)入 (為(wei)本公司(si)生(sheng)產的試(shi)驗(yan)(yan)變(bian)(bian)壓(ya)器(qi)(qi)配套專用設備,詳細資(zi)料請見其具體使(shi)用說明(ming)書(shu))系(xi)列操作箱(臺),經操作箱內自(zi)偶(ou)調(diao)壓(ya)器(qi)(qi)(50kVA以上調(diao)壓(ya)器(qi)(qi)外附(fu))調(diao)節(jie)至0~200V(或0~400V)電壓(ya)輸(shu)出至YDQ試(shi)驗(yan)(yan)變(bian)(bian)壓(ya)器(qi)(qi)的初級繞組,根據(ju)電磁感應原理,在(zai)試(shi)驗(yan)(yan)變(bian)(bian)壓(ya)器(qi)(qi)高(gao)(gao)壓(ya)繞組可獲得試(shi)驗(yan)(yan)所需(xu)的高(gao)(gao)電壓(ya)。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

單臺YDQ系(xi)列交直流(liu)高(gao)(gao)壓(ya)(ya)試驗(yan)變壓(ya)(ya)器的工作原理圖(tu)見圖(tu)3,圖(tu)中(zhong)高(gao)(gao)壓(ya)(ya)套管(guan)中(zhong)裝有高(gao)(gao)壓(ya)(ya)硅堆(dui),串接(jie)在高(gao)(gao)壓(ya)(ya)回路(lu)中(zhong)作半波(bo)整流(liu),以獲得直流(liu)高(gao)(gao)電(dian)壓(ya)(ya)。當(dang)用一短(duan)路(lu)桿將(jiang)高(gao)(gao)壓(ya)(ya)硅堆(dui)短(duan)接(jie)時,可(ke)獲得工頻(pin)高(gao)(gao)電(dian)壓(ya)(ya),作為(wei)交流(liu)輸出狀(zhuang)態;取(qu)消短(duan)路(lu)桿時,作為(wei)直流(liu)輸出狀(zhuang)態。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

圖中:D—短路(lu)桿(gan)       &nbsp;    VD—高壓硅(gui)堆

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

試驗(yan)變壓(ya)器高壓(ya)套管(guan)中(zhong)的高壓(ya)硅堆(dui)未畫(hua)出(chu),其原理與(yu)上圖相同。

三(san)臺(tai)(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)串(chuan)級獲得(de)更高(gao)(gao)(gao)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)的(de)(de)(de)(de)接線原理見圖4。串(chuan)級高(gao)(gao)(gao)壓(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)有很(hen)大的(de)(de)(de)(de)優越性,因為整(zheng)個試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)裝(zhuang)置由(you)幾臺(tai)(tai)單臺(tai)(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)組(zu)成(cheng),單臺(tai)(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)容量(liang)小(xiao)、電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)低、重量(liang)輕,便(bian)于運輸和安裝(zhuang)。它既然(ran)可串(chuan)接成(cheng)高(gao)(gao)(gao)出幾倍的(de)(de)(de)(de)單臺(tai)(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)輸出電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)組(zu)合使(shi)(shi)用,又(you)可分(fen)開成(cheng)幾套單臺(tai)(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)單獨(du)使(shi)(shi)用。整(zheng)套裝(zhuang)置投資小(xiao),經(jing)濟實惠。圖5中(zhong),在(zai)第(di)**和**級的(de)(de)(de)(de)每個單元試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)中(zhong)都有一個勵(li)(li)磁(ci)繞(rao)組(zu)A1、C1和A2、C2。在(zai)三(san)臺(tai)(tai)串(chuan)級試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)基(ji)本(ben)原理中(zhong),低壓(ya)(ya)(ya)(ya)電(dian)(dian)(dian)源(yuan)加在(zai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅰ的(de)(de)(de)(de)初(chu)級繞(rao)組(zu)a1x1上(shang),單臺(tai)(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅰ、Ⅱ、Ⅲ的(de)(de)(de)(de)輸出電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)都是V。勵(li)(li)磁(ci)繞(rao)組(zu)A1、C1給(gei)**級試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅱ的(de)(de)(de)(de)初(chu)級繞(rao)組(zu)供(gong)電(dian)(dian)(dian);**級試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅱ的(de)(de)(de)(de)勵(li)(li)磁(ci)繞(rao)組(zu)A2、C2給(gei)第(di)三(san)級試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅲ的(de)(de)(de)(de)初(chu)級繞(rao)組(zu)供(gong)電(dian)(dian)(dian)。**級試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅱ和第(di)三(san)級試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅲ的(de)(de)(de)(de)箱體(ti)分(fen)別處在(zai)對地為1V和2V的(de)(de)(de)(de)高(gao)(gao)(gao)電(dian)(dian)(dian)位(wei)上(shang),所以箱體(ti)對地是絕緣的(de)(de)(de)(de),試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅰ的(de)(de)(de)(de)箱體(ti)是接地的(de)(de)(de)(de)。這(zhe)樣第(di)**、**級、第(di)三(san)級試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)對地的(de)(de)(de)(de)額定(ding)(ding)輸出電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)分(fen)別為1V、2V、3V;其額定(ding)(ding)容量(liang)分(fen)別為3P、2P、1P。

YDQ系(xi)列高壓試驗變壓器做被(bei)試品的工頻(pin)耐(nai)壓試驗使用接線原(yuan)理圖見(jian)圖5。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

圖中:R1—限流電阻 FRC—阻容(rong)分壓器(qi) RF—球間隙保護電阻 G—球間隙 CX—被試品(pin)

注:高(gao)壓尾必須(xu)可靠接地

工頻耐壓(ya)(ya)試驗(yan)中(zhong)限流(liu)電(dian)(dian)阻R1應根據(ju)試驗(yan)變壓(ya)(ya)器的(de)額(e)定容量來選(xuan)擇。如高壓(ya)(ya)側額(e)定輸(shu)出電(dian)(dian)流(liu)在100~300mA時,可取(qu)(qu)0.5~1Ω/V(試驗(yan)電(dian)(dian)壓(ya)(ya));高壓(ya)(ya)側額(e)定輸(shu)出電(dian)(dian)流(liu)為1A以上時,可取(qu)(qu)1Ω/V(試驗(yan)電(dian)(dian)壓(ya)(ya))。常(chang)用(yong)水電(dian)(dian)阻作為限流(liu)電(dian)(dian)阻,管(guan)子(zi)長度(du)可按(an)150kV/m考慮,管(guan)子(zi)粗(cu)細應具(ju)有(you)足夠的(de)熱容量(水阻液配制(zhi)方(fang)法:用(yong)蒸(zheng)餾水加入(ru)適量硫酸銅配制(zhi)成各種不同的(de)阻值)。

球間(jian)隙(xi)及保護電阻:當電壓超過(guo)球間(jian)隙(xi)整(zheng)定(ding)值時(一般取(qu)(qu)試驗(yan)(yan)電壓的110%~120%),球間(jian)隙(xi)放電,對(dui)被(bei)試品起(qi)到保護作用(yong)。球間(jian)隙(xi)保護電阻可按1Ω/V(試驗(yan)(yan)電壓)選取(qu)(qu)。

在工(gong)頻(pin)耐壓(ya)(ya)(ya)(ya)試(shi)(shi)驗中,低電壓(ya)(ya)(ya)(ya)側測量電壓(ya)(ya)(ya)(ya)(儀表電壓(ya)(ya)(ya)(ya))不是(shi)(shi)非常準確的(de)(de)(de)(de),其原因是(shi)(shi)由于試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)(ya)器存(cun)(cun)在著(zhu)漏抗,在這個漏抗上(shang)(shang)必然存(cun)(cun)在著(zhu)壓(ya)(ya)(ya)(ya)降或(huo)容(rong)升,使試(shi)(shi)品上(shang)(shang)的(de)(de)(de)(de)電壓(ya)(ya)(ya)(ya)低于或(huo)高于低壓(ya)(ya)(ya)(ya)側測量電壓(ya)(ya)(ya)(ya)表上(shang)(shang)反映出(chu)(chu)來的(de)(de)(de)(de)電壓(ya)(ya)(ya)(ya)。工(gong)頻(pin)耐壓(ya)(ya)(ya)(ya)試(shi)(shi)驗時,被試(shi)(shi)品上(shang)(shang)的(de)(de)(de)(de)電壓(ya)(ya)(ya)(ya)高于試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)(ya)器的(de)(de)(de)(de)輸出(chu)(chu)電壓(ya)(ya)(ya)(ya),也就是(shi)(shi)所謂容(rong)升現象。感應耐壓(ya)(ya)(ya)(ya)試(shi)(shi)驗時,試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)(ya)器的(de)(de)(de)(de)漏抗必然存(cun)(cun)在著(zhu)壓(ya)(ya)(ya)(ya)降。為了準確測量被試(shi)(shi)品上(shang)(shang)所施加的(de)(de)(de)(de)電壓(ya)(ya)(ya)(ya),因此(ci)常在高壓(ya)(ya)(ya)(ya)側接入FRC阻容(rong)分壓(ya)(ya)(ya)(ya)器來測量電壓(ya)(ya)(ya)(ya)(見圖5)。

工頻耐壓試驗(yan)操作注意事項

1)試驗人員應做好(hao)分(fen)工(gong),明確相互間聯系方法。并有專門人監護現場**及觀(guan)察試品狀(zhuang)態(tai)。

2)被試(shi)品(pin)應(ying)先清(qing)掃干凈(jing),并**干燥,以免損壞被試(shi)品(pin)和試(shi)驗帶來的誤差(cha)。

3)對(dui)于大型試(shi)驗(yan),一般都應(ying)先進行空升試(shi)驗(yan)。即(ji)不(bu)接試(shi)品時升壓至試(shi)驗(yan)電(dian)壓,校對(dui)各種表計,調整球間隙。

4)升壓(ya)(ya)速度不能太快,并必須(xu)防止突然加壓(ya)(ya)。例如調壓(ya)(ya)器不在(zai)零位(wei)時(shi)突然合閘(zha)。也不能突然切斷(duan)電(dian)源(yuan),一(yi)般應(ying)在(zai)調壓(ya)(ya)器降至零位(wei)時(shi)拉(la)閘(zha)。

5)當電壓(ya)(ya)升至試(shi)驗電壓(ya)(ya)時,開始計時,到1min后,迅速降(jiang)壓(ya)(ya)到1/3試(shi)驗電壓(ya)(ya)以下時,才能拉開電源。

6)在升壓或耐(nai)壓試(shi)驗過程中,如(ru)發現下列不正(zheng)常(chang)情況時,應立即降(jiang)壓,切斷電源。停止試(shi)驗并查明原因:①電壓表指針擺動很大;②發現絕緣(yuan)燒焦或冒煙;③被(bei)試(shi)品(pin)內有不正(zheng)常(chang)的聲(sheng)音。

7)耐(nai)壓試(shi)驗前(qian)后應測量絕緣(yuan)(yuan)電阻(zu),檢查絕緣(yuan)(yuan)情況。

試驗(yan)變壓器在做被試品的直流耐壓或泄(xie)露試驗(yan)時接線原理圖(tu)(tu)如圖(tu)(tu)6。

注:此試驗應先抽出短路桿(gan)“D”,圖(tu)6中所(suo)示。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

圖中(zhong):VD—高壓(ya)硅堆 R1—限(xian)流電(dian)阻 C1—高壓(ya)濾波電(dian)容 FRC—阻容分壓(ya)器 CX—被試品 μA—帶(dai)保(bao)護微安(an)表

泄露試(shi)驗中限流(liu)電(dian)(dian)阻(zu)R1選(xuan)擇在額定輸出電(dian)(dian)壓時(shi),輸出端短路電(dian)(dian)流(liu)不超過高(gao)壓硅堆的*大(da)整流(liu)。如電(dian)(dian)壓硅堆的*大(da)整流(liu)電(dian)(dian)流(liu)為100mA時(shi)用于60kV的試(shi)驗裝置中,限流(liu)電(dian)(dian)阻(zu)按R1=60/0.1=600kΩ選(xuan)擇。限流(liu)電(dian)(dian)阻(zu)還應具有足夠的容(rong)量和沿面(mian)放電(dian)(dian)距離。

高壓濾(lv)波電容C1一般選擇在0.01~0.1μF,當被試品的電容量很(hen)大時(shi),C1可(ke)省略不用(yong)。

泄露試驗的操(cao)作及注意(yi)事項

1)試(shi)驗(yan)前應先檢查被試(shi)品是否(fou)停電(dian),接地放電(dian),一切對外連線(xian)是否(fou)擦干凈。要嚴(yan)防將試(shi)驗(yan)電(dian)壓加到(dao)有(you)人工作(zuo)的(de)部位上去。

2)接好試(shi)驗裝置的(de)(de)接線后(hou),應(ying)復(fu)查(cha)無(wu)誤后(hou)才(cai)可加(jia)壓(ya)。應(ying)特別(bie)注意檢查(cha)高壓(ya)設備及引線與(yu)地、與(yu)操作人員的(de)(de)**距離(li),被(bei)試(shi)品的(de)(de)外殼(ke)是(shi)否可靠接地,要按**規程中所規定(ding)的(de)(de)內容進行(xing)試(shi)驗。

3)對于大電(dian)容量設備應(ying)緩慢升(sheng)壓,防(fang)止(zhi)被試品的充電(dian)電(dian)流燒壞(huai)微(wei)安(an)表。必要時應(ying)分(fen)級加壓,分(fen)別讀(du)取各級電(dian)壓下微(wei)安(an)表的穩定讀(du)數。

4)試驗(yan)過(guo)程中,應(ying)密(mi)切監視被(bei)試品、試驗(yan)裝(zhuang)置、微安表,一(yi)旦發生擊穿、閃爍等異(yi)常現象應(ying)立即(ji)降壓(ya),切斷電源(yuan),并(bing)查明原因,詳(xiang)細記錄。

5)試(shi)驗(yan)完畢,降壓,切斷(duan)電(dian)源后應將被試(shi)品(pin)及(ji)試(shi)驗(yan)裝(zhuang)置本身充分放電(dian)。

四、注意事項

1、按照您所進(jin)行的試(shi)驗(yan)接好(hao)工作(zuo)線路(lu)。試(shi)驗(yan)變壓器的外殼(ke)以及操作(zuo)系(xi)統的外殼(ke)必須(xu)可靠接地(di)。試(shi)驗(yan)變壓器高壓繞組的X端(高壓尾)以及測量繞組的F端必須(xu)可靠接地(di)。

2、做串級(ji)(ji)試(shi)(shi)驗(yan)時,**級(ji)(ji)、第(di)三級(ji)(ji)試(shi)(shi)驗(yan)變(bian)壓(ya)(ya)器(qi)的(de)(de)低壓(ya)(ya)繞(rao)組的(de)(de)X端,測量繞(rao)組的(de)(de)F端以及高(gao)壓(ya)(ya)繞(rao)組的(de)(de)X端(高(gao)壓(ya)(ya)尾)均接本級(ji)(ji)試(shi)(shi)驗(yan)變(bian)壓(ya)(ya)器(qi)的(de)(de)外殼(ke)。**級(ji)(ji)、第(di)三級(ji)(ji)試(shi)(shi)驗(yan)變(bian)壓(ya)(ya)器(qi)的(de)(de)外殼(ke)必(bi)須通(tong)過絕緣支架(jia)接地。

3、接通(tong)電(dian)源前,操作系統的調(diao)壓器必須調(diao)到零(ling)位后方可接通(tong)電(dian)源,合(he)閘,開始升壓。

4、從(cong)零(ling)開始均勻旋轉調壓(ya)(ya)(ya)(ya)器手(shou)輪升(sheng)壓(ya)(ya)(ya)(ya)。升(sheng)壓(ya)(ya)(ya)(ya)方法(fa)(fa)(fa)有:快速(su)(su)升(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa),即(ji)20s逐(zhu)級升(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa);慢(man)速(su)(su)升(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa),即(ji)60s逐(zhu)級升(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa);極慢(man)速(su)(su)升(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa)供選用。電(dian)壓(ya)(ya)(ya)(ya)從(cong)零(ling)開始按(an)一定(ding)的升(sheng)壓(ya)(ya)(ya)(ya)方式和(he)速(su)(su)度上升(sheng)到您(nin)所需(xu)的額(e)定(ding)試(shi)(shi)驗(yan)電(dian)壓(ya)(ya)(ya)(ya)的75%后,在以每秒(miao)2%額(e)定(ding)試(shi)(shi)驗(yan)電(dian)壓(ya)(ya)(ya)(ya)的速(su)(su)度升(sheng)到您(nin)所需(xu)的額(e)定(ding)電(dian)壓(ya)(ya)(ya)(ya),并密切(qie)注意(yi)測(ce)量(liang)儀表(biao)的指(zhi)示以及被試(shi)(shi)品的情況(kuang)(kuang)。升(sheng)壓(ya)(ya)(ya)(ya)過(guo)程(cheng)(cheng)中(zhong)或(huo)試(shi)(shi)驗(yan)過(guo)程(cheng)(cheng)中(zhong)如(ru)發現測(ce)量(liang)儀表(biao)的指(zhi)示及被試(shi)(shi)品情況(kuang)(kuang)異(yi)常,應立即(ji)降壓(ya)(ya)(ya)(ya),切(qie)斷電(dian)源(yuan),查明情況(kuang)(kuang)。

5、試驗完畢后(hou),應在數秒內勻速的將調壓器返回至零位,然后(hou)切斷電源。

6、本產品不得超(chao)過額(e)定參數使用。除試驗必須(xu)外,決不允許全電(dian)壓通電(dian)或斷電(dian)。

7、 再升壓(ya)(ya)或耐壓(ya)(ya)試驗(yan)過程中(zhong),如發現以下不正常情況時,應立即降壓(ya)(ya),切斷(duan)電源,停(ting)止(zhi)試驗(yan)并查明原因。

⑴電壓表指針擺動(或數字跳(tiao)動)很大

⑵電流(liu)表直線上升

被試品內有不正常(chang)的聲音(yin)

8、圖1中第(di)9項(xiang)系壓(ya)(ya)(ya)力(li)閥(fa)(fa)及壓(ya)(ya)(ya)力(li)表,為長期關閉狀態(tai)。每6個月開閥(fa)(fa)一次,以檢查(cha)SF6壓(ya)(ya)(ya)力(li),應不小于0.2MPa(檢查(cha)壓(ya)(ya)(ya)力(li)后(hou)立即關閉閥(fa)(fa)門),低(di)于0.2MPa時(shi)應加SF6氣體,以增加氣絕緣(yuan)。

9、耐(nai)壓實驗(yan)前(qian)后應測量(liang)被試設備的(de)絕緣電阻,檢查絕緣情況。

10、當試(shi)驗變壓(ya)器長期不使用(yong)時(shi),應放置(zhi)于通風、干燥、無陽光直射的地方。

11、該(gai)產品不允許在高于45℃的溫度下長期存放、使用、放氣。

12、運(yun)輸搬運(yun)途中不得重力沖擊。

13、產品(pin)緊固件及壓力(li)閥、壓力(li)表不得擅自松(song)動。

14、使用本產品做高壓(ya)試驗時(shi),出(chu)熟悉本說明(ming)書外,還必須嚴格(ge)執(zhi)行國家有關標(biao)準和(he)操作(zuo)規程(cheng)。可(ke)參照GB311-83《高壓(ya)輸變設(she)備的絕緣配合(he),高壓(ya)試驗技術(shu)》;《電氣設(she)備預(yu)防性(xing)試驗規程(cheng)》等。


五、試驗變壓(ya)器(qi)的容量選(xuan)擇

標(biao)稱試驗變(bian)壓器容量(liang)Pn的確(que)定(ding)公式:Pn=kVn 2ωCt×10-9

式中:

Pn——標(biao)稱試驗變(bian)壓(ya)器容量(kVA)

Vn——試(shi)驗變(bian)壓(ya)器的額定輸出高(gao)壓(ya)的有效值(kV)

k ——**系數(shu)。k≥1,標(biao)稱(cheng)電(dian)壓Vn≥1MV時,k=2;標(biao)稱(cheng)電(dian)壓較低時,k值可取高一(yi)些(xie)。

Ct——被試品的(de)電容(rong)量(pF)

ω——角頻(pin)率,ω=2πf,f——試驗(yan)電源的頻(pin)率

被試設(she)備的電容量Ct可由(you)交流電橋測出。Ct的變化很大,

可由設(she)備的類型而(er)定。

典型(xing)數據如下:

簡單的棒式或懸(xuan)式絕(jue)緣子      &nbsp;   ;   幾十微法

簡單(dan)的分級套管        &nbsp;            100~1000pF

電壓互感器     &nbsp; &nbsp;                 200 ~ 500pF

電力變壓器  < 1000kVA~1000pF

> 1000kVA  1000~10000pF

高壓電力(li)電纜和油浸紙絕緣     &nbsp;     250~300pF/m

氣體絕緣(yuan)                      &nbsp;    ~60pF/m

封(feng)閉(bi)變電站,SF6氣體絕緣 &nbsp;          100~10000Pf;


對于不同的試驗電壓(ya)Vn,選擇不同的(適當的)**系(xi)數k。

以下列出不同的Vn所選(xuan)用的k值供參考。

Vn =50~100kV        k = 4

Vn =150~300kV       k = 3

Vn > 300kV&nbsp;         k = 2

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

一、概述

工頻耐壓試(shi)驗是(shi)鑒定電力設(she)備絕(jue)緣強(qiang)度的*嚴格、*有效和*直接的方法(fa)。它能(neng)(neng)檢(jian)查出(chu)那些危險性較大的集中缺(que)陷,對判斷電力設(she)備能(neng)(neng)否(fou)繼續參加運行(xing)具有決(jue)定性作用,是(shi)保證(zheng)設(she)備絕(jue)緣水平、避免發生絕(jue)緣事故的重(zhong)要(yao)手段。

本(ben)裝(zhuang)置是根據(ju)國家*新電力行業標(biao)準而設(she)(she)計的(de)(de)(de)、性能先進的(de)(de)(de)耐壓(ya)試(shi)驗(yan)設(she)(she)備,用于(yu)對(dui)各種電器產品、電氣元件、絕(jue)緣材料(liao)等進行規(gui)定電壓(ya)下的(de)(de)(de)絕(jue)緣強度試(shi)驗(yan),以考核產品的(de)(de)(de)絕(jue)緣水(shui)平,發現(xian)被試(shi)品的(de)(de)(de)絕(jue)緣缺(que)陷,衡量過電壓(ya)的(de)(de)(de)能力。

二、產(chan)品特點(dian)

監視功能:高壓電(dian)壓 低壓電(dian)流  零位指示(shi)(shi)  電(dian)源指示(shi)(shi) 工作指示(shi)(shi) 計時指示(shi)(shi)

保護功能:過流保護、零(ling)位啟動保護、聲光語言(yan)報警(jing)提(ti)醒

采用(yong)新型時(shi)間繼電(dian)器,計時(shi)范圍(wei)更廣(1S~99H)

采用新型電(dian)流繼(ji)電(dian)器(qi),更**、更可(ke)靠,確(que)保人身及設(she)備**。

試驗變(bian)壓(ya)器高壓(ya)線圈為圓筒多(duo)層塔(ta)式,由上等(deng)聚酯漆包線及高耐(nai)壓(ya)值絕緣材料繞制而(er)成(cheng)。

試驗變壓器(qi)(5kVA以上)裝有可移動的鐵輪。具有重量輕、體積小(xiao)、移動方便、性(xing)能優(you)越(yue)等特點。

三、設備(bei)組成

1、選型配置

標準(zhun)配(pei)置

□ 分體式

操作部(bu)分:

□箱式(不大于5kVA) / □臺式

容量:    kVA(小于(yu)200kVA)

輸入:□AC220V / □AC380V

試驗變壓器:

□交(jiao)流 / □交(jiao)直(zhi)流

□油(you)變 / □干變 / □氣變

容量(liang):    kVA(小于200kVA)

輸出:AC  kV(小于(yu)300kVA)

□ 一(yi)體(ti)式

□箱式(不大(da)于20kV) / □臺式(不大(da)于30kV)

容(rong)量:     kVA(小于300kVA)

輸入:□AC220V / □AC380V  輸出(chu):AC &nbsp;  kV(不(bu)大于30kV)

客戶選(xuan)配(pei)

□標準高壓分壓器

□保(bao)護(hu)球(qiu)隙

□直流(liu)微安表

□放(fang)**

□保護水阻(zu)

□高(gao)壓濾(lv)波電容

其它:

2、對應實物

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

四、技術(shu)指(zhi)標

1、使用條件(jian):

(1)工作場所應(ying)無嚴重影響絕(jue)緣的氣體、蒸(zheng)汽(qi)、化(hua)學性(xing)(xing)塵埃及其它爆炸性(xing)(xing)和腐蝕性(xing)(xing)介(jie)質。

(2)環境溫度(du)  -20~+50℃

(3)環境濕度  ≤85% RH(無凝結水)


2、控制(zhi)箱(xiang)(臺)參數(shu):(常規(gui)參數(shu)見下表)

規(gui)格

容(rong)量(liang)

輸 入 電 源

輸  出 電 壓

重量(kg)

相數

(V)

(A)

(V)

(A)

2/220

2

1

220

10

0-250

8

14

3/220

3

1

220

15

0-250

12

16

5/220

5

1

220

25

0-250

20

18

10/220

10

1

220

50

0-250

40

80

15/380

15

2

380

37.5

0-430

34.8

90

20/380

20

2

380

50

0-430

46.5

100

25/380

25

2

380

62.5

0-430

58.1

120

30/380

30

2

380

75

0-430

69.7

140

50/380

50

2

380

125

0-430

116.2

160

100/380

100

2

380

250

0-430

232.5

250


















說明(ming):如有特殊參數(shu)要求(qiu),可按用(yong)戶的技術參數(shu)進行(xing)設計(ji)制作。

3、試驗(yan)變壓器(qi)參數:(常(chang)規(gui)參數見下表)


規格


容(rong)量

kVA

低壓側

高壓側

高壓側(交直流變壓器(qi))

測量變比

60分鐘溫升℃

阻抗電(dian)壓%

空載電流(liu)


質(zhi)量

kg

電壓

V

電流

A

交(jiao)流輸出

直流輸出

電壓kV

電流

電壓kV

電流

1.5/50

1.5

200

7.5

50

30

70

21.4

500

50

10

<4

19.5

3/50

3

200

15

50

60

70

42.9

500

50

10

<4

27

5/50

5

200

25

50

100

70

71.4

500

50

10

<4

52

10/50

10

200

50

50

200

70

142.9

500

50

10

<4

80

15/50

15

400

37.5

50

300

70

214.3

500

50

8

<4

120

20/50

20

400

50

50

400

70

285.7

500

50

8

<4

140

30/50

30

400

75

50

600

70

428.6

500

50

8

<4

155

50/50

50

400

125

50

1000

70

714.3

500

50

8

<4

184

10/100

10

200

50

100

100

140

71.4

1000

50

10

<4

135

15/100

15

400

37.5

100

150

140

107.1

1000

50

8

<4

150

20/100

20

400

50

100

200

140

142.9

1000

50

8

<4

215

30/100

30

400

75

100

300

140

214.3

1000

50

8

<4

250

50/100

50

400

125

100

500

140

357.1

1000

50

8

<4

290

10/150

10

200

50

100

66.7

140

47.6

1500

50

10

<4

180

15/150

15

400

37.5

150

100

210

71.4

1500

50

8

<4

200

20/150

30

400

50

150

133.3

210

95.2

1500

50

8

<4

220

30/150

30

400

75

150

200

210

142.9

1500

50

8

<4

280

50/150

50

400

125

150

333.3

210

238.1

1500

50

8

<4

340

說(shuo)明:如有特殊參數要求,可按用戶(hu)的技(ji)術(shu)參數進行(xing)設計制作。

上表的重量以油浸(jin)式試驗變(bian)壓器為(wei)例,干式試驗變(bian)壓器和充(chong)氣式試驗變(bian)壓器稍有(you)不(bu)同。

五、接線(xian)及工作原理(li)

1、調壓(ya)部(bu)分接線(xian)及(ji)原理

調壓(ya)部分(fen)由(you)控(kong)制(zhi)部分(fen)和試驗變壓(ya)器組成(cheng)(cheng)。控(kong)制(zhi)部分(fen)是由(you)接觸(chu)式調壓(ya)器及其控(kong)制(zhi)、保護、測量、信號電路組成(cheng)(cheng)。試驗變壓(ya)器由(you)低壓(ya)繞(rao)(rao)組、高(gao)壓(ya)繞(rao)(rao)組、儀表(biao)繞(rao)(rao)組三部分(fen)組成(cheng)(cheng)。

試(shi)驗(yan)變(bian)壓器為(wei)交直(zhi)流(liu)兩用時,試(shi)驗(yan)變(bian)壓器配置(zhi)(zhi)了高(gao)壓硅堆(油變(bian)、氣(qi)(qi)變(bian)為(wei)內(nei)置(zhi)(zhi),干(gan)變(bian)為(wei)外置(zhi)(zhi)),高(gao)壓可輸出交流(liu)和(he)直(zhi)流(liu)。輸出交流(liu)時,要(yao)求(qiu)接入短路(lu)桿(gan)(油變(bian)、氣(qi)(qi)變(bian))或去掉(diao)外置(zhi)(zhi)硅堆(干(gan)變(bian));輸出直(zhi)流(liu)時,要(yao)求(qiu)擰出短路(lu)桿(gan)(油變(bian)、氣(qi)(qi)變(bian))或加上外置(zhi)(zhi)硅堆(干(gan)變(bian))

通過接入工頻電源(yuan),調(diao)節調(diao)壓(ya)器,以獲得(de)所(suo)需要的(de)試驗(yan)高壓(ya)電壓(ya)值。其(qi)工作原理(li)見(jian)圖1:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

2、試驗部分接(jie)線及原理

做耐(nai)壓(ya)(ya)試驗(yan)時,控制部分(fen)、變(bian)壓(ya)(ya)器的接地(di)端(duan)及高壓(ya)(ya)尾必須可靠接地(di)。有條(tiao)件(jian)的情況下,做工(gong)頻耐(nai)壓(ya)(ya)試驗(yan)請加上(shang)限流電(dian)阻、標(biao)準(zhun)高壓(ya)(ya)分(fen)壓(ya)(ya)器、球隙保護電(dian)阻及保護球隙,如(ru)圖(tu)3。

做直(zhi)流(liu)耐壓(ya)(ya)(ya)試驗請另外加上(shang)(shang)微安表,微安表必須(xu)接(jie)在硅堆和被試器(qi)之(zhi)間(jian),油(you)變(bian)(bian)或氣變(bian)(bian)一般擰(ning)(ning)在高壓(ya)(ya)(ya)頭(tou)上(shang)(shang)面(mian)(要求擰(ning)(ning)出(chu)短路桿),干(gan)變(bian)(bian)擰(ning)(ning)在外置(zhi)硅堆上(shang)(shang)面(mian);為了更準確顯(xian)示(shi)高壓(ya)(ya)(ya)直(zhi)流(liu)泄(xie)漏電(dian)流(liu),請將分(fen)壓(ya)(ya)(ya)器(qi)的高壓(ya)(ya)(ya)線接(jie)在微安表和硅堆之(zhi)間(jian),(油(you)變(bian)(bian)、氣變(bian)(bian))如圖(tu)4,(干(gan)變(bian)(bian))如圖(tu)5。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

耐(nai)壓(ya)(ya)試(shi)(shi)驗(yan)中(zhong)限(xian)流(liu)電(dian)(dian)阻R1應根據(ju)試(shi)(shi)驗(yan)變壓(ya)(ya)器(qi)的額(e)定容量來選擇。如高(gao)壓(ya)(ya)側額(e)定輸出電(dian)(dian)流(liu)在100~300mA時,可(ke)取0.5~1Ω/V(試(shi)(shi)驗(yan)電(dian)(dian)壓(ya)(ya));高(gao)壓(ya)(ya)側額(e)定輸出電(dian)(dian)流(liu)為1A以(yi)上時,可(ke)取1Ω/V(試(shi)(shi)驗(yan)電(dian)(dian)壓(ya)(ya))。常用(yong)水(shui)電(dian)(dian)阻作為限(xian)流(liu)電(dian)(dian)阻,管(guan)子(zi)長度可(ke)按150kV/m考慮,管(guan)子(zi)粗(cu)細應具有(you)足夠的熱容量(水(shui)阻液配制(zhi)方法(fa):用(yong)蒸餾水(shui)加入適量硫酸銅(tong)配制(zhi)成各種不同的阻值)。

球(qiu)(qiu)(qiu)(qiu)間隙(xi)及保護電(dian)(dian)阻(zu):當電(dian)(dian)壓(ya)超過球(qiu)(qiu)(qiu)(qiu)間隙(xi)整定值時(shi)(一(yi)般取(qu)試驗(yan)電(dian)(dian)壓(ya)的110%~120%),球(qiu)(qiu)(qiu)(qiu)間隙(xi)放電(dian)(dian),對被(bei)試品起到(dao)保護作用。球(qiu)(qiu)(qiu)(qiu)間隙(xi)保護電(dian)(dian)阻(zu)可按(an)1Ω/V(試驗(yan)電(dian)(dian)壓(ya))選取(qu)。

在工頻(pin)耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗中,低電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側測(ce)量(liang)電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(儀表(biao)(biao)電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya))不是(shi)(shi)非常(chang)準(zhun)確(que)的(de)(de),其(qi)原因是(shi)(shi)由(you)于(yu)試(shi)(shi)驗變(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)存(cun)(cun)在著(zhu)漏(lou)抗(kang),在這個漏(lou)抗(kang)上(shang)(shang)必然(ran)存(cun)(cun)在著(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)降或(huo)容升,使試(shi)(shi)品上(shang)(shang)的(de)(de)電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)低于(yu)或(huo)高于(yu)低壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側測(ce)量(liang)電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)表(biao)(biao)上(shang)(shang)反映(ying)出來的(de)(de)電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)。工頻(pin)耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗時(shi),被試(shi)(shi)品上(shang)(shang)的(de)(de)電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)高于(yu)試(shi)(shi)驗變(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)的(de)(de)輸出電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya),也(ye)就(jiu)是(shi)(shi)所謂容升現(xian)象(xiang)。感應耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗時(shi),試(shi)(shi)驗變(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)的(de)(de)漏(lou)抗(kang)必然(ran)存(cun)(cun)在著(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)降。為了準(zhun)確(que)測(ce)量(liang)被試(shi)(shi)品上(shang)(shang)所施加的(de)(de)電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya),因此常(chang)在高壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側接入標準(zhun)高壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)分壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)來測(ce)量(liang)電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)。


五(wu)、面板結構說明

1、操作箱(xiang)面(mian)板(ban)

控制箱(xiang)為箱(xiang)式鋁合金結構,面(mian)板采用(yong)拉絲鋁合金工藝,所有電器元件均裝(zhuang)在骨架(jia)上,便于(yu)安(an)裝(zhuang)和維修。面(mian)板元件布置如(ru)下:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

2、操作臺面板

操作臺為臺式結(jie)構(gou),殼體(ti)為冷扎鋼板(ban)結(jie)構(gou),面(mian)板(ban)采用鋁合金拉絲工藝,面(mian)板(ban)元件(jian)布(bu)置如下:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

六、操作指(zhi)南

本裝置在操(cao)作(zuo)之前應(ying)根據不(bu)同被試品的(de)容量、電(dian)壓等級,先(xian)計算好*大工作(zuo)電(dian)流,并調整電(dian)流保護(hu)器。其(qi)試驗接(jie)線應(ying)參考本說明書中圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5,必須(xu)可靠(kao)接(jie)地。

1、操作要(yao)點(dian)

(1)試(shi)驗前,應(ying)了解被(bei)試(shi)品(pin)的試(shi)驗電壓(ya)(ya),同(tong)時了解被(bei)試(shi)品(pin)的其他試(shi)驗項目及以前的試(shi)驗結(jie)果。若被(bei)試(shi)品(pin)有缺陷或異常,應(ying)在(zai)消除后再進行耐壓(ya)(ya)試(shi)驗。

(2)試(shi)驗(yan)現場應圍好(hao)遮攔或圍繩,掛好(hao)標示牌,并派(pai)專人監護。

(3)試(shi)驗前,被(bei)(bei)(bei)試(shi)品表面應(ying)(ying)擦拭干凈,將被(bei)(bei)(bei)試(shi)品的(de)外殼和(he)非被(bei)(bei)(bei)試(shi)繞組(zu)可靠接地。被(bei)(bei)(bei)試(shi)品為新沖(chong)油設備(bei)時(shi),應(ying)(ying)按《規(gui)程(cheng)》規(gui)定使油靜(jing)(jing)止一定時(shi)間再升壓,對110kV及以下(xia)的(de)充油電(dian)力設備(bei),在注(zhu)滿油后(hou)靜(jing)(jing)置時(shi)間應(ying)(ying)不(bu)(bu)少(shao)于(yu)24小(xiao)時(shi),對220kV及330kV的(de)充油電(dian)力設備(bei),靜(jing)(jing)置時(shi)間應(ying)(ying)不(bu)(bu)少(shao)于(yu)48小(xiao)時(shi)。

(4)接好試驗接線后,應(ying)由有經驗的人(ren)員檢查,確(que)認(ren)無誤后方可升壓。

(5)升(sheng)壓(ya)前,首先檢查調(diao)壓(ya)器是否在零位。調(diao)壓(ya)器在零位方(fang)可升(sheng)壓(ya)。

(6)升(sheng)(sheng)(sheng)壓(ya)過程中不(bu)僅(jin)要監視電(dian)(dian)(dian)壓(ya)表(biao)的變化(hua)(hua),還應監視電(dian)(dian)(dian)流表(biao)的變化(hua)(hua),以及被試品(pin)電(dian)(dian)(dian)流的變化(hua)(hua)。升(sheng)(sheng)(sheng)壓(ya)時(shi)要均(jun)勻升(sheng)(sheng)(sheng)壓(ya),不(bu)能(neng)太快。升(sheng)(sheng)(sheng)至(zhi)規定(ding)試驗電(dian)(dian)(dian)壓(ya)時(shi),開(kai)始計算時(shi)間,時(shi)間到后,緩慢均(jun)勻降下(xia)電(dian)(dian)(dian)壓(ya)。絕不(bu)允許不(bu)降壓(ya)就先跳開(kai)電(dian)(dian)(dian)源開(kai)關。

(7)試驗中(zhong)發現表針擺(bai)動或被試品有異(yi)常聲響、冒(mao)煙等(deng)應立(li)即降下電(dian)(dian)壓(ya),拉開電(dian)(dian)源,在高壓(ya)側(ce)掛上(shang)接(jie)地線后,再查明原因。

(8)耐壓試驗前后均應測量被試品的絕緣(yuan)電阻。

2、操作步驟

(1) 按試驗(yan)要求將控制部分、試驗(yan)變壓器、被試品正確接(jie)好線(xian),必須可靠接(jie)地,請參考圖(tu)(tu)1、圖(tu)(tu)2、圖(tu)(tu)3、圖(tu)(tu)4、圖(tu)(tu)5。

(2) 根(gen)據試驗(yan)的要求,整定(ding)“時間繼電器(qi)”及“過流繼電器(qi)”。

A  時間繼電器設置:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

T1,T2,T3,T4設置0~9任意數字,T可設置為H(小時(shi)),M(分鐘),S(秒)。

根據(ju)試驗要(yao)求,在1S~99H內(nei)可以(yi)任意設置定時時間。

B 過流(liu)繼(ji)電器(qi)設置:

過流(liu)動作設定值(zhi)=過流(liu)繼電(dian)(dian)器(qi)(qi)刻度盤讀數×測(ce)量變(bian)比(bi)×K,其(qi)中K為(wei)(wei)電(dian)(dian)流(liu)倍(bei)率/切除(chu)(chu)開關(guan)的(de)狀態值(zhi),分別為(wei)(wei)X1,X2,OFF,電(dian)(dian)流(liu)倍(bei)率/切除(chu)(chu)開關(guan)處于×1,×2位(wei)置時(shi)(shi),K值(zhi)分別為(wei)(wei)1、2,切換為(wei)(wei)OFF擋時(shi)(shi),K值(zhi)為(wei)(wei)+∞。(注:不要(yao)使用OFF檔,因為(wei)(wei)會使變(bian)壓器(qi)(qi)失去過流(liu)保護(hu)功能而導致(zhi)設備損(sun)壞。測(ce)量變(bian)比(bi)為(wei)(wei)電(dian)(dian)流(liu)互(hu)感器(qi)(qi)的(de)變(bian)比(bi),沒有電(dian)(dian)流(liu)互(hu)感器(qi)(qi)時(shi)(shi)為(wei)(wei)1)。

(3) 接入(ru)電源,此時,“電源燈(deng)”亮(liang),表示(shi)外部電源已引入(ru)。如(ru)“零位燈(deng)”亮(liang),表示(shi)調(diao)壓(ya)器(qi)在零位。如(ru)“零位燈(deng)”不亮(liang),應逆(ni)時針(zhen)旋轉調(diao)節調(diao)壓(ya)器(qi)手柄(bing)至“零位燈(deng)”亮(liang),表示(shi)可進行調(diao)壓(ya)操(cao)作。

(4)按“啟動(dong)按鈕”。此時,“送(song)電燈(deng)”,“電源燈(deng)”和“零位燈(deng)”亮;進入送(song)電狀態(tai)。

(5)以2kV/S勻速順時針旋(xuan)轉調壓器手柄至(zhi)被試品(pin)規定(ding)的耐壓值,并密(mi)切注視電流(liu)(liu)表(biao)(直(zhi)流(liu)(liu)耐壓試驗時,同(tong)時密(mi)切注視直(zhi)流(liu)(liu)微(wei)安(an)表(biao))。此時,“電源(yuan)燈”,“工作燈”亮;“零(ling)位燈”滅(mie)。

(6)根據試(shi)驗啟動“計時(shi)按鈕”,計時(shi)開始,并(bing)注意被(bei)試(shi)品的情況。

(7)當耐壓(ya)計時到時,操作臺自動聲光報(bao)警。應立即逆時針(zhen)旋轉調壓(ya)器手柄至零位(wei),按(an)(an)下停止按(an)(an)鈕(niu)和解除計時按(an)(an)鈕(niu)自鎖(suo)狀態。此時“電源燈”, “零位(wei)燈”亮,“工作燈”滅。試驗即告完畢

(8)拔掉電(dian)源,拆除接線,試驗結束。

(9)在升壓(ya)或耐壓(ya)過(guo)(guo)程中,如發(fa)生短路(lu)、閃(shan)絡、擊穿過(guo)(guo)流(liu)時,過(guo)(guo)流(liu)繼(ji)電器(qi)(qi)動(dong)作,切斷(duan)主回路(lu)。此時應將(jiang)調(diao)壓(ya)器(qi)(qi)逆時針旋轉至零位(wei),切斷(duan)電源,并查明原因(yin),并作詳(xiang)細(xi)記錄。

(10)試(shi)驗完(wan)畢,降壓,切斷電(dian)(dian)源(yuan)后(hou)應用放**將被試(shi)品及試(shi)驗裝置本身充分放電(dian)(dian)。

七、產品(pin)維護(hu)

1、開箱(xiang)驗收時,應檢(jian)查主控回(hui)路接線是否(fou)松動(dong),調壓器電刷(shua)是否(fou)接觸良好;

2、長(chang)期不(bu)用時(shi),使用前(qian)應用500V兆歐表測量(liang)絕緣電阻(zu),其(qi)阻(zu)值不(bu)低于0.5MΩ;

3、電(dian)(dian)源電(dian)(dian)壓應符合控(kong)制箱(臺)銘牌上的輸入電(dian)(dian)壓值(zhi);

4、本裝置設有過電流保護,出廠已調整為額(e)定電流的50%。用于(yu)小負載時,應根(gen)據(ju)被試(shi)品的額(e)定容(rong)量(liang)電流重新設定;

5、使用完畢(bi)后,應關(guan)好(hao)控制箱(xiang)(臺)門,以保持(chi)控制箱(xiang)(臺)內(nei)部清(qing)潔(jie)。


八、注意事項

1、按照您(nin)所進行的試驗接好工作(zuo)線(xian)路。試驗變壓(ya)器的外殼(ke)以(yi)及(ji)操作(zuo)系統的外殼(ke)必須可靠(kao)接地(di)。試驗變壓(ya)器的高壓(ya)繞(rao)組(zu)的X端(高壓(ya)尾)以(yi)及(ji)測量繞(rao)組(zu)的F端必須可靠(kao)接地(di)。

2、做串(chuan)級(ji)(ji)試(shi)驗(yan)(yan)時,**級(ji)(ji)、第(di)三級(ji)(ji)試(shi)驗(yan)(yan)變壓器(qi)的(de)低壓繞組成(cheng)X端(duan)(duan),測量(liang)繞組的(de)F端(duan)(duan)以及高(gao)壓繞組的(de)X端(duan)(duan)(高(gao)壓端(duan)(duan))均接本級(ji)(ji)試(shi)驗(yan)(yan)變壓器(qi)具外殼。**級(ji)(ji)、第(di)三級(ji)(ji)試(shi)驗(yan)(yan)變壓器(qi)的(de)外殼必須通過(guo)絕緣支架接地。

3、接通電(dian)源前,操作(zuo)系統(tong)的(de)(de)調(diao)壓(ya)(ya)(ya)(ya)器必須調(diao)到零位(wei)后方(fang)可接通電(dian)源,合閘(zha),開始(shi)升(sheng)壓(ya)(ya)(ya)(ya)。從零開始(shi)勻速旋(xuan)轉調(diao)壓(ya)(ya)(ya)(ya)器手輪(lun)升(sheng)壓(ya)(ya)(ya)(ya)。升(sheng)壓(ya)(ya)(ya)(ya)方(fang)式有:快速升(sheng)壓(ya)(ya)(ya)(ya)法(fa),即20s逐級(ji)升(sheng)壓(ya)(ya)(ya)(ya)法(fa);慢速升(sheng)壓(ya)(ya)(ya)(ya)法(fa),即60s逐級(ji)升(sheng)壓(ya)(ya)(ya)(ya)法(fa);極(ji)慢速升(sheng)壓(ya)(ya)(ya)(ya)法(fa)供選用。電(dian)壓(ya)(ya)(ya)(ya)從零開始(shi)按(an)一定的(de)(de)升(sheng)壓(ya)(ya)(ya)(ya)方(fang)式和(he)速度上升(sheng)到您所(suo)需的(de)(de)額(e)定試(shi)驗電(dian)壓(ya)(ya)(ya)(ya)的(de)(de)75%后,再以(yi)每(mei)秒2%額(e)定試(shi)驗電(dian)壓(ya)(ya)(ya)(ya)的(de)(de)速度升(sheng)到您所(suo)需的(de)(de)試(shi)驗電(dian)壓(ya)(ya)(ya)(ya),并密切注(zhu)意(yi)測量儀(yi)表(biao)的(de)(de)及被試(shi)品的(de)(de)情況。升(sheng)壓(ya)(ya)(ya)(ya)過(guo)程(cheng)中或試(shi)驗過(guo)程(cheng)中如發現測量儀(yi)表(biao)的(de)(de)指示及被試(shi)品情況異常,應(ying)立即降壓(ya)(ya)(ya)(ya),切斷電(dian)源,查(cha)明情況。

4、試驗完畢后(hou),應在數秒(miao)內勻速(su)的將調壓器返(fan)回至零(ling)位,然后(hou)切斷電源。本產品不得超過(guo)額定參(can)數使用。

5、使(shi)用本產(chan)品做高(gao)壓(ya)試驗(yan)時,除熟悉(xi)本說明書外,還必須嚴格執(zhi)行(xing)國家有關標(biao)準和操(cao)作規程(cheng)。可(ke)參照GB311.1 – 97《高(gao)壓(ya)輸變設備的絕緣配合,高(gao)壓(ya)試驗(yan)技術》;《電氣設備預防(fang)性試驗(yan)規程(cheng)》等

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

一、概(gai)述

智能(neng)耐壓試(shi)驗(yan)裝置是根(gen)據國(guo)家*新電(dian)力行業(ye)標準而設計的(de)(de)、性(xing)能(neng)先進的(de)(de)智能(neng)型耐壓試(shi)驗(yan)設備,用于對各種電(dian)器(qi)產品、電(dian)氣元件、絕(jue)(jue)緣(yuan)材(cai)料等(deng)進行規定電(dian)壓下的(de)(de)絕(jue)(jue)緣(yuan)強度(du)試(shi)驗(yan),以(yi)考核(he)產品的(de)(de)絕(jue)(jue)緣(yuan)水平,發現被(bei)試(shi)品的(de)(de)絕(jue)(jue)緣(yuan)缺陷,衡量過電(dian)壓的(de)(de)能(neng)力。廣泛(fan)應用于電(dian)工(gong)制(zhi)造部門、電(dian)力運(yun)行部門、科研單(dan)位和(he)高等(deng)院(yuan)校。

二(er)、產品特(te)點

1. 320×240液晶顯示器、高(gao)速熱(re)敏打印機(ji)。

2. 高壓(ya)電(dian)(dian)壓(ya)、高壓(ya)電(dian)(dian)流、低壓(ya)電(dian)(dian)壓(ya)、低壓(ya)電(dian)(dian)流4路測量方式(shi),高精度(du)傳感(gan)器(qi)和高性能14位AD采集芯片。

3. 人機對(dui)話全(quan)鍵盤操作方式(shi),智能(neng)化工作全(quan)過程,任選自動方式(shi)和(he)手動方式(shi)。

4. 實時顯(xian)(xian)示高壓電(dian)壓、高壓電(dian)流、低(di)(di)壓電(dian)壓、低(di)(di)壓電(dian)流,時間及耐(nai)壓結果,顯(xian)(xian)示直觀明了。

5. 完(wan)善的過壓、過流保護,任意設定輸出電壓、高壓電流上(shang)限、低壓電流上(shang)限和計時(shi)(shi)時(shi)(shi)間。

6. 具有回(hui)零(ling)檢測(ce)功能,回(hui)零(ling)確定后(hou)才(cai)可(ke)(ke)進(jin)行(xing)試(shi)驗,**可(ke)(ke)靠。

7. 具有絕緣電(dian)阻測試功(gong)能,直(zhi)接(jie)反(fan)映被試品絕緣強度(du)。

8. 逼(bi)近式調壓算法,到達設定電壓后(hou)(hou)自(zi)動(dong)耐(nai)壓計(ji)時,計(ji)時結(jie)束后(hou)(hou)自(zi)動(dong)降壓回零。

9.&nbsp;超(chao)過設(she)定高(gao)壓(ya)(ya)電(dian)流或(huo)低壓(ya)(ya)電(dian)流時自動切斷電(dian)壓(ya)(ya)輸(shu)出,降壓(ya)(ya)回零,并(bing)發生聲(sheng)光報(bao)警。

10. 精良(liang)的(de)軟硬件抗干(gan)擾設計(ji),多種抗干(gan)擾手段,適應惡劣電(dian)磁環境。

11. 自動錯誤診(zhen)斷,易于發現和解(jie)決(jue)問題。

12. 可選(xuan)配無線遙控(kong)控(kong)制功能、遠程通信、門聯鎖警鈴、外接分壓器校驗(yan)接口(kou)等。


三、設備組成

1、選型(xing)配置

標準配置

□ 分體式

操作部(bu)分:

□箱(xiang)式(不(bu)大于5kVA) / □臺式

容量:    kVA(小(xiao)于200kVA)

輸入:□AC220V / □AC380V

試驗變壓(ya)器(qi):

□交流(liu) / □交直流(liu)

□油變(bian) / □干變(bian) / □氣變(bian)

容量:    kVA(小于200kVA)

輸出:AC  kV(小于300kVA)

□ 一體式

□箱式(shi)(不(bu)大于20kV) / □臺式(shi)(不(bu)大于30kV)

容(rong)量(liang): &nbsp;   kVA(小于300kVA)

輸入:□AC220V / □AC380V  輸出:AC    kV(不大于(yu)30kV)

客戶選(xuan)配

□標準(zhun)高(gao)壓(ya)分壓(ya)器

□保護球(qiu)隙

□直(zhi)流微安(an)表

□放(fang)**

□保護水阻

□高壓濾(lv)波(bo)電容

其它:

2、對應實物

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

四、技術指標

1、使用(yong)條件(jian):

(1)工作(zuo)場(chang)所(suo)應無(wu)嚴(yan)重影響絕緣的(de)氣體(ti)、蒸汽、化學性(xing)塵埃及其它爆炸性(xing)和腐(fu)蝕(shi)性(xing)介(jie)質。

(2)環(huan)境溫度 &nbsp;      -20~+50℃

(3)環境濕度&nbsp;&nbsp;      ≤85% RH(無凝結水)

2、控制箱(臺)參(can)數(shu):(常規(gui)參(can)數(shu)見下表)

(1)計時范圍:0-999S

(3)電壓精度  ≤1.5% ±1個字(F.S)

(4)電(dian)流精度  ≤1.5% ±1個字(F.S)

規(gui)格(ge)

容量

輸 入(ru) 電 源(yuan)

輸  出 電(dian) 壓

重量(liang)(kg)

相數

(V)

(A)

(V)

(A)

2/220

2

1

220

10

0-250

8

14

3/220

3

1

220

15

0-250

12

16

5/220

5

1

220

25

0-250

20

18

10/220

10

1

220

50

0-250

40

80

15/380

15

2

380

37.5

0-430

34.8

90

20/380

20

2

380

50

0-430

46.5

100

25/380

25

2

380

62.5

0-430

58.1

120

30/380

30

2

380

75

0-430

69.7

140

50/380

50

2

380

125

0-430

116.2

160

100/380

100

2

380

250

0-430

232.5

250


















說明:如有特殊(shu)參(can)數要求(qiu),可按(an)用戶的技術(shu)參(can)數進行設計制作。

3、試(shi)驗變(bian)壓器參數:(常規參數見下表(biao))


規格


容量

kVA

低壓側(ce)

高壓側

高(gao)壓(ya)側(ce)(交直流(liu)變壓(ya)器)

測量變比

60分(fen)鐘溫(wen)升℃

阻抗(kang)電壓%

空載電流


質量

kg

電壓

V

電流

A

交流輸(shu)出

直流輸出

電壓(ya)kV

電(dian)流

電壓kV

電流

1.5/50

1.5

200

7.5

50

30

70

21.4

500

50

10

<4

19.5

3/50

3

200

15

50

60

70

42.9

500

50

10

<4

27

5/50

5

200

25

50

100

70

71.4

500

50

10

<4

52

10/50

10

200

50

50

200

70

142.9

500

50

10

<4

80

15/50

15

400

37.5

50

300

70

214.3

500

50

8

<4

120

20/50

20

400

50

50

400

70

285.7

500

50

8

<4

140

30/50

30

400

75

50

600

70

428.6

500

50

8

<4

155

50/50

50

400

125

50

1000

70

714.3

500

50

8

<4

184

10/100

10

200

50

100

100

140

71.4

1000

50

10

<4

135

15/100

15

400

37.5

100

150

140

107.1

1000

50

8

<4

150

20/100

20

400

50

100

200

140

142.9

1000

50

8

<4

215

30/100

30

400

75

100

300

140

214.3

1000

50

8

<4

250

50/100

50

400

125

100

500

140

357.1

1000

50

8

<4

290

10/150

10

200

50

100

66.7

140

47.6

1500

50

10

<4

180

15/150

15

400

37.5

150

100

210

71.4

1500

50

8

<4

200

20/150

30

400

50

150

133.3

210

95.2

1500

50

8

<4

220

30/150

30

400

75

150

200

210

142.9

1500

50

8

<4

280

50/150

50

400

125

150

333.3

210

238.1

1500

50

8

<4

340

說明(ming):如(ru)有特(te)殊參(can)數(shu)要求(qiu),可按用戶的技術參(can)數(shu)進(jin)行設計(ji)制(zhi)作。

上表(biao)的(de)重(zhong)量以油浸式(shi)試驗變(bian)壓(ya)器(qi)為例,干(gan)式(shi)試驗變(bian)壓(ya)器(qi)和(he)充氣(qi)式(shi)試驗變(bian)壓(ya)器(qi)稍有不(bu)同。


五、接線及工作原理

1、調壓部分接線及原理

調壓(ya)(ya)部(bu)分(fen)由(you)控(kong)制(zhi)部(bu)分(fen)和試驗(yan)變壓(ya)(ya)器(qi)組成。控(kong)制(zhi)部(bu)分(fen)是由(you)接觸式調壓(ya)(ya)器(qi)、單片機控(kong)制(zhi)系(xi)統、液(ye)晶(jing)、打印機、信(xin)號測量、電(dian)路保護(hu)組成。試驗(yan)變壓(ya)(ya)器(qi)由(you)低(di)壓(ya)(ya)繞組、高壓(ya)(ya)繞組、儀表(biao)繞組三部(bu)分(fen)組成。

試驗變壓器為(wei)交直(zhi)(zhi)流兩用(yong)時(shi)(shi),試驗變壓器配置了高壓硅(gui)堆(油變、氣(qi)變為(wei)內置,干變為(wei)外置),高壓可輸出(chu)(chu)(chu)交流和(he)直(zhi)(zhi)流。輸出(chu)(chu)(chu)交流時(shi)(shi),要(yao)求(qiu)接入短路桿(油變、氣(qi)變)或去掉外置硅(gui)堆(干變);輸出(chu)(chu)(chu)直(zhi)(zhi)流時(shi)(shi),要(yao)求(qiu)擰出(chu)(chu)(chu)短路桿(油變、氣(qi)變)或加上外置硅(gui)堆(干變)

通過接入工頻(pin)電(dian)源,調節調壓器,以(yi)獲(huo)得所需(xu)要(yao)的(de)試驗高壓電(dian)壓值。其工作原理(li)見圖1:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

2、試(shi)驗部分接線及原理

做(zuo)(zuo)耐壓(ya)試(shi)驗時(shi),控制(zhi)部分、變壓(ya)器的接地端(duan)及高壓(ya)尾必(bi)須可靠接地。有條(tiao)件的情況下,做(zuo)(zuo)工頻(pin)耐壓(ya)試(shi)驗請加上限流(liu)電阻、標準高壓(ya)分壓(ya)器、球隙保護(hu)電阻及保護(hu)球隙,如圖(tu)3。

做直流耐壓試(shi)驗請另外加(jia)上微安表(biao),微安表(biao)必須接在(zai)(zai)硅(gui)堆(dui)(dui)和被試(shi)器之(zhi)間,油變(bian)(bian)或氣變(bian)(bian)一般擰在(zai)(zai)高壓頭(tou)上面(要求擰出短路桿),干變(bian)(bian)擰在(zai)(zai)外置硅(gui)堆(dui)(dui)上面;為了更準確顯示高壓直流泄(xie)漏電流,請將分壓器的高壓線接在(zai)(zai)微安表(biao)和硅(gui)堆(dui)(dui)之(zhi)間,(油變(bian)(bian)、氣變(bian)(bian))如(ru)圖(tu)4,(干變(bian)(bian))如(ru)圖(tu)5。

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

耐壓試(shi)(shi)驗(yan)中限流(liu)電(dian)(dian)阻R1應根據試(shi)(shi)驗(yan)變壓器(qi)的(de)額(e)定(ding)容量(liang)來選擇。如高壓側額(e)定(ding)輸出電(dian)(dian)流(liu)在100~300mA時,可取(qu)(qu)0.5~1Ω/V(試(shi)(shi)驗(yan)電(dian)(dian)壓);高壓側額(e)定(ding)輸出電(dian)(dian)流(liu)為1A以(yi)上時,可取(qu)(qu)1Ω/V(試(shi)(shi)驗(yan)電(dian)(dian)壓)。常(chang)用水(shui)電(dian)(dian)阻作為限流(liu)電(dian)(dian)阻,管子長度可按(an)150kV/m考(kao)慮,管子粗細應具有(you)足夠的(de)熱容量(liang)(水(shui)阻液配制方法:用蒸餾(liu)水(shui)加入適量(liang)硫酸銅(tong)配制成各(ge)種(zhong)不(bu)同(tong)的(de)阻值)。

球(qiu)間隙及保護(hu)電阻(zu):當(dang)電壓超過球(qiu)間隙整定值(zhi)時(一般取試(shi)驗(yan)電壓的(de)110%~120%),球(qiu)間隙放(fang)電,對(dui)被試(shi)品起到保護(hu)作用(yong)。球(qiu)間隙保護(hu)電阻(zu)可(ke)按1Ω/V(試(shi)驗(yan)電壓)選取。

在工(gong)頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)中,低(di)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)側測量電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(儀表(biao)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya))不是非常準(zhun)確的(de)(de)(de),其(qi)原(yuan)因是由于(yu)試(shi)驗(yan)變壓(ya)(ya)(ya)(ya)(ya)器存在著(zhu)漏(lou)抗,在這(zhe)個漏(lou)抗上(shang)必(bi)然存在著(zhu)壓(ya)(ya)(ya)(ya)(ya)降(jiang)或容(rong)升(sheng),使試(shi)品上(shang)的(de)(de)(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)低(di)于(yu)或高于(yu)低(di)壓(ya)(ya)(ya)(ya)(ya)側測量電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)表(biao)上(shang)反映(ying)出(chu)(chu)來的(de)(de)(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)。工(gong)頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)時(shi),被試(shi)品上(shang)的(de)(de)(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)高于(yu)試(shi)驗(yan)變壓(ya)(ya)(ya)(ya)(ya)器的(de)(de)(de)輸出(chu)(chu)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya),也就是所謂容(rong)升(sheng)現(xian)象。感應耐(nai)壓(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)時(shi),試(shi)驗(yan)變壓(ya)(ya)(ya)(ya)(ya)器的(de)(de)(de)漏(lou)抗必(bi)然存在著(zhu)壓(ya)(ya)(ya)(ya)(ya)降(jiang)。為了(le)準(zhun)確測量被試(shi)品上(shang)所施加的(de)(de)(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya),因此常在高壓(ya)(ya)(ya)(ya)(ya)側接入(ru)標(biao)準(zhun)高壓(ya)(ya)(ya)(ya)(ya)分壓(ya)(ya)(ya)(ya)(ya)器來測量電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)。

六、操(cao)作要(yao)點

1、試(shi)驗(yan)前,應了解被試(shi)品(pin)的(de)試(shi)驗(yan)電壓(ya)(ya),同時了解被試(shi)品(pin)的(de)其他試(shi)驗(yan)項(xiang)目及以(yi)前的(de)試(shi)驗(yan)結(jie)果。若被試(shi)品(pin)有缺陷(xian)或異(yi)常,應在消除后再進行耐壓(ya)(ya)試(shi)驗(yan)。

2、試驗(yan)現場應圍好遮攔或圍繩,掛(gua)好標示(shi)牌,并派專人(ren)監(jian)護。

3、試(shi)驗前,被(bei)試(shi)品(pin)表面應(ying)擦拭干(gan)凈,將被(bei)試(shi)品(pin)的(de)外殼(ke)和(he)非被(bei)試(shi)繞組可靠接地(di)。被(bei)試(shi)品(pin)為(wei)新沖油(you)設備(bei)(bei)時,應(ying)按《規程(cheng)》規定使油(you)靜止一(yi)定時間(jian)再升壓(ya),對110kV及以下的(de)充(chong)油(you)電(dian)力設備(bei)(bei),在注(zhu)滿(man)油(you)后(hou)靜置時間(jian)應(ying)不少于24小時,對220kV及330kV的(de)充(chong)油(you)電(dian)力設備(bei)(bei),靜置時間(jian)應(ying)不少于48小時。

4、接(jie)好(hao)試驗接(jie)線后,應由有(you)經驗的人員(yuan)檢查(cha),確認無誤后方可升(sheng)壓。

5、升壓前,首先檢查調壓器(qi)是否在(zai)零位。調壓器(qi)在(zai)零位方可升壓。

6、升(sheng)壓過程中不(bu)僅要監(jian)視電(dian)(dian)壓的(de)變(bian)化(hua),還應監(jian)視電(dian)(dian)流(liu)的(de)變(bian)化(hua),以及被試品(pin)泄漏電(dian)(dian)流(liu)的(de)變(bian)化(hua)。升(sheng)壓時要均(jun)勻(yun)升(sheng)壓,不(bu)能太快。升(sheng)至規定試驗(yan)電(dian)(dian)壓時,開始計時,時間(jian)到后,緩慢均(jun)勻(yun)降(jiang)下(xia)電(dian)(dian)壓。絕不(bu)允許不(bu)降(jiang)壓就先(xian)跳(tiao)開電(dian)(dian)源開關(guan)。

7、試驗中(zhong)發(fa)現被(bei)試品(pin)有異常聲響(xiang)、冒煙等應立即降下電壓,拉(la)開電源,在高壓側(ce)掛上(shang)接地線后,再查明(ming)原因。耐(nai)壓試驗前(qian)后均應測(ce)量被(bei)試品(pin)的絕緣電阻。

七、面板(ban)功能說明

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

打印(yin)(yin)機(ji):打印(yin)(yin)機(ji)是熱敏(min)打印(yin)(yin)機(ji),當試驗完(wan)成后按鍵(jian)盤上的“打印(yin)(yin)”按鈕打印(yin)(yin)試驗結果。

RS232:RS232是與計算機相連的串(chuan)口(kou)(kou)通信接(jie)口(kou)(kou),是用(yong)戶選配接(jie)口(kou)(kou),本裝置(zhi)沒有配置(zhi)這(zhe)個接(jie)口(kou)(kou)。

LCD對比(bi)度(du)(du):因為液晶(jing)顯示屏在溫(wen)度(du)(du)和光(guang)線有所(suo)不(bu)同時稍(shao)有些變(bian)化,可以通(tong)過(guo)LCD對比(bi)度(du)(du)調節背光(guang)到適(shi)合亮度(du)(du)。

液(ye)晶(jing): 320x240像素點(dian)陣白色(se)背光液(ye)晶(jing),在(zai)強(qiang)光和陰(yin)暗環境下都十分清楚。

指示(shi)燈(deng)(deng)(deng):由啟動燈(deng)(deng)(deng)、零位燈(deng)(deng)(deng)、指示(shi)燈(deng)(deng)(deng)三個燈(deng)(deng)(deng)組(zu)成,啟動燈(deng)(deng)(deng)和警示(shi)燈(deng)(deng)(deng)是(shi)高亮(liang)七彩燈(deng)(deng)(deng)。

操(cao)作(zuo)提示:有一些簡短的提示語句和安裝接線圖。

緊(jin)急開(kai)關:在(zai)緊(jin)急情況下按此開(kai)關,即可以(yi)切(qie)斷變壓器(qi)電(dian)源(yuan)(yuan),也可以(yi)切(qie)斷工作電(dian)源(yuan)(yuan)。(箱式安(an)裝在(zai)面板上,臺式安(an)裝在(zai)柜體上)

鍵(jian)盤:由上、下、左(zuo)、右、設置、打印、確定、取消8個(ge)鍵(jian)組成,是用戶和設備(bei)交(jiao)互(hu)的終端。

電源開關(guan):工(gong)作電源,帶通電指示燈。


八、軟件使(shi)用說明

按試(shi)驗要求將控制部(bu)分、試(shi)驗變壓器、被試(shi)品正(zheng)確接(jie)好線,必須可靠接(jie)地(di),請參考圖1、圖2、圖3、圖4、圖5。

1、開機使(shi)用

開機處(chu)于(yu)“歡迎界(jie)面”,如圖7:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

根據鍵盤的示(shi)圖8,按上↑、下↓、左(zuo)←,右(you)→可以(yi)切換“自動耐壓(ya)試驗(yan)(yan)(yan)”或(huo)“手動耐壓(ya)試驗(yan)(yan)(yan)”,在“自動試驗(yan)(yan)(yan)”或(huo)“手動試驗(yan)(yan)(yan)”里(li)面選擇“交流(liu)試驗(yan)(yan)(yan)方式”或(huo)“直流(liu)試驗(yan)(yan)(yan)方式”。如(ru)圖9

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

說明:

(1)當配(pei)置的是交直(zhi)(zhi)流兩(liang)用(yong)控制部分時,使用(yong)直(zhi)(zhi)流輸(shu)出(chu)時軟(ruan)件操(cao)作(zuo)請(qing)進入直(zhi)(zhi)流試驗(yan)方(fang)(fang)式(shi),交流輸(shu)出(chu)時軟(ruan)件操(cao)作(zuo)請(qing)進入交流試驗(yan)方(fang)(fang)式(shi),如果選擇(ze)錯誤(wu)會(hui)(hui)導致(zhi)儀器顯示電壓(ya)會(hui)(hui)和輸(shu)出(chu)實際電壓(ya)不一(yi)致(zhi)。

(2)當(dang)配置的是交(jiao)直流兩(liang)用(yong)變(bian)壓器時,使(shi)用(yong)直流時請將(jiang)變(bian)壓器的短(duan)路(lu)桿(gan)(gan)取出(chu),當(dang)使(shi)用(yong)交(jiao)流時請將(jiang)短(duan)路(lu)桿(gan)(gan)插(cha)入擰緊。

(3)如(ru)果(guo)配置的是交流控制部分時,軟件界面里就沒有交直流試驗方式(如(ru)圖(tu)9)的選擇項。

選中試驗方式后,按確定(ding)可以進入(ru)主界面,如圖10:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

動(dong)態顯示區:一直處于采(cai)集信號,并顯示高壓電(dian)壓、高壓電(dian)流、低壓電(dian)壓、低壓電(dian)流。

結果(guo)顯示區(qu):如果(guo)試(shi)驗(yan)沒有被擊穿時,顯示平(ping)均高壓(ya)電(dian)壓(ya),平(ping)均高壓(ya)電(dian)流(liu),平(ping)均低壓(ya)電(dian)壓(ya),平(ping)均低壓(ya)電(dian)流(liu),絕緣電(dian)阻;否(fou)之,顯示峰(feng)值(zhi)電(dian)壓(ya),峰(feng)值(zhi)電(dian)流(liu),低壓(ya)電(dian)壓(ya),低壓(ya)電(dian)流(liu)。

設置數據區(qu):設置試驗(yan)中需(xu)要的參數數據輸出電(dian)(dian)(dian)壓(ya)(ya)(ya)為(wei)(wei)在自動方式(shi)下的升壓(ya)(ya)(ya)目標耐(nai)壓(ya)(ya)(ya)值耐(nai)壓(ya)(ya)(ya)時間為(wei)(wei)耐(nai)壓(ya)(ya)(ya)過(guo)程的時間長(chang)度電(dian)(dian)(dian)流(liu)上限(xian)為(wei)(wei)高壓(ya)(ya)(ya)電(dian)(dian)(dian)流(liu)峰(feng)值的上限(xian),高壓(ya)(ya)(ya)電(dian)(dian)(dian)流(liu)超過(guo)電(dian)(dian)(dian)流(liu)上限(xian)將認(ren)為(wei)(wei)擊(ji)(ji)穿(chuan)過(guo)流(liu)保護(hu)為(wei)(wei)低壓(ya)(ya)(ya)電(dian)(dian)(dian)流(liu)峰(feng)值的上限(xian),低壓(ya)(ya)(ya)電(dian)(dian)(dian)流(liu)超過(guo)過(guo)流(liu)保護(hu)將認(ren)為(wei)(wei)擊(ji)(ji)穿(chuan)

信(xin)(xin)息顯示區:顯示試驗(yan)過程中的(de)試驗(yan)狀態和提示信(xin)(xin)息。

試(shi)驗操作(zuo)區:選擇設置、試(shi)驗、回零命令。

2、設置參(can)數

在主界面上,選中“設置”,然(ran)后(hou)按確定后(hou)進入設置界面,如圖11:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

按左←,右(you)→時切換光(guang)標(biao)移動位置(zhi)(zhi),按上↑、下↓時更改光(guang)標(biao)位置(zhi)(zhi)數(shu)據的值(zhi)。光(guang)標(biao)位置(zhi)(zhi)和(he)設置(zhi)(zhi)的數(shu)值(zhi)全部可以(yi)自動循環,前且在使(shi)用時有(you)默認的標(biao)準值(zhi)。如果所有(you)的參(can)數(shu)都設置(zhi)(zhi)完成,按取消退出設置(zhi)(zhi)回(hui)到主界面開始狀態。

3、手(shou)動試驗(yan)

零位檢查—當(dang)選中“試(shi)(shi)驗(yan)”后,按(an)確定就(jiu)進入提(ti)示試(shi)(shi)驗(yan)狀態。如果調壓(ya)器不在零位,將提(ti)示“試(shi)(shi)驗(yan)前請先回(hui)零”,退出(chu)試(shi)(shi)驗(yan)并且(qie)切換到回(hui)零命令。

試(shi)驗(yan)過程(cheng)—回零確認(ren)后,可以進行試(shi)驗(yan)。選(xuan)中“試(shi)驗(yan)”后按確定,接觸器合閘(zha),這時輸(shu)出電壓幾乎為0,如圖12:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

按上(shang)↑,高壓(ya)電壓(ya)將(jiang)不斷升(sheng)壓(ya),松開就(jiu)停(ting)止(zhi)升(sheng)壓(ya),如果到(dao)上(shang)限就(jiu)提示滿量程(cheng);

按下↓,高壓(ya)電壓(ya)將不(bu)斷降壓(ya),松開就(jiu)停(ting)止降壓(ya),如(ru)果到(dao)下限就(jiu)提示已回零;

按計(ji)時←,計(ji)時開始工作,到耐壓時間(jian)計(ji)時結束(shu)完成試(shi)驗;

按取消(xiao)→,取消(xiao)試驗(yan)過程;

在升(sheng)壓(ya)(ya)過程(cheng)中,如果(guo)高(gao)(gao)(gao)壓(ya)(ya)電(dian)流(liu)峰(feng)值超(chao)過“電(dian)流(liu)上(shang)(shang)限(xian)”值或(huo)低壓(ya)(ya)電(dian)流(liu)峰(feng)值超(chao)過“過流(liu)保護”值將認為被試(shi)品被擊(ji)穿(chuan),接觸器(qi)立(li)刻分(fen)閘并顯(xian)示試(shi)驗結(jie)果(guo),包括(kuo)峰(feng)值電(dian)壓(ya)(ya)、峰(feng)值電(dian)流(liu)、低壓(ya)(ya)電(dian)流(liu)等(deng),調壓(ya)(ya)器(qi)開始回(hui)零(ling),回(hui)零(ling)完(wan)成(cheng)試(shi)驗結(jie)束。如果(guo)在耐壓(ya)(ya)過程(cheng)中,高(gao)(gao)(gao)壓(ya)(ya)電(dian)流(liu)和低壓(ya)(ya)電(dian)流(liu)峰(feng)值沒有超(chao)設置上(shang)(shang)限(xian)值,認為被試(shi)品未(wei)擊(ji)穿(chuan),結(jie)果(guo)顯(xian)示區就顯(xian)示耐壓(ya)(ya)電(dian)壓(ya)(ya)、高(gao)(gao)(gao)壓(ya)(ya)電(dian)流(liu)、低壓(ya)(ya)電(dian)流(liu)、絕緣電(dian)阻等(deng),調壓(ya)(ya)器(qi)開始回(hui)零(ling),回(hui)零(ling)完(wan)成(cheng)后接觸器(qi)分(fen)閘試(shi)驗結(jie)束。

4、自動試驗

自動試(shi)(shi)驗(yan)和手動試(shi)(shi)驗(yan)的(de)試(shi)(shi)驗(yan)過程(cheng)類似,首先也進(jin)行回零檢查,確(que)認后進(jin)入如下界面,如圖13:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

按上方法(fa)切換到“開始”確(que)定后進(jin)(jin)行試驗,與手動(dong)試驗不同之處就(jiu)是(shi)升(sheng)(sheng)壓過(guo)程將自動(dong)升(sheng)(sheng)壓到“輸(shu)出電壓”值,然后進(jin)(jin)行計(ji)時。

升(sheng)壓(ya)過(guo)程為(wei)逼近方式,首先(xian)升(sheng)到到接近目標值(zhi),然后再進行微調(diao),保證高壓(ya)電壓(ya)值(zhi)幾(ji)乎為(wei)輸出電壓(ya)值(zhi)。

5、功能選擇

按(an)鍵盤上的“設(she)置”就進入功能界面,如圖14:

調頻式<strong><strong><strong><strong><strong><strong><strong><strong><strong>串聯諧振</strong></strong></strong></strong></strong></strong></strong></strong></strong>變

進入(ru)功能界面后(hou),可以(yi)選擇“時(shi)鐘設(she)置(zhi)”、“注意(yi)事項”等界面。

時鐘設置:設置時鐘的時間(jian),為打印報表提供時間(jian)依據。

注意事(shi)(shi)項(xiang):為(wei)用戶提供一(yi)些操作規范和**注意事(shi)(shi)項(xiang)。

6、打印

按鍵(jian)盤“打印(yin)”按鍵(jian)可以打印(yin)試驗果,在此不贅述。

七、產品維護

1、開箱(xiang)驗收時,應檢查主控回路接線是(shi)否(fou)松動(dong),調(diao)壓器(qi)電刷是(shi)否(fou)接觸良好。

2.、長(chang)期不(bu)用(yong)(yong)時,使(shi)用(yong)(yong)前應(ying)用(yong)(yong)500V兆歐表測量絕緣電阻(zu),其阻(zu)值(zhi)不(bu)低于0.5MΩ。

3、電源電壓應(ying)符合控(kong)制箱(臺)說明書上的輸入電壓值要求。

4、本控制箱(臺)設有過電(dian)流保護,出(chu)廠(chang)已調整(zheng)為額定(ding)電(dian)流的50%。用(yong)于(yu)小負載(zai)時,應根據被試品的額定(ding)容量電(dian)流重新設定(ding);

5、使(shi)用(yong)完畢(bi)后(hou),應(ying)關好控制(zhi)箱(臺(tai))門蓋,以保持(chi)內(nei)部清潔。

八、注意事項

1、按照您(nin)所(suo)進行(xing)的(de)試(shi)(shi)驗(yan)接好(hao)工作線路。試(shi)(shi)驗(yan)變壓器的(de)外殼(ke)以及操(cao)作系統(tong)的(de)外殼(ke)必(bi)須(xu)可(ke)靠(kao)接地。試(shi)(shi)驗(yan)變壓器的(de)測(ce)量繞(rao)組的(de)F端和外殼(ke)必(bi)須(xu)可(ke)靠(kao)接地。

2、做串(chuan)級試(shi)驗(yan)(yan)(yan)時,**級、第三級試(shi)驗(yan)(yan)(yan)變(bian)壓(ya)(ya)器的低壓(ya)(ya)繞組成X端,測量(liang)繞組的F端以及高壓(ya)(ya)繞組的X端(高壓(ya)(ya)端)均接本級試(shi)驗(yan)(yan)(yan)變(bian)壓(ya)(ya)器具(ju)外殼。**級、第三級試(shi)驗(yan)(yan)(yan)變(bian)壓(ya)(ya)器的外殼必須通(tong)過絕緣(yuan)支架(jia)接地。

接(jie)通電源前,控制箱(臺)的調壓器必(bi)須(xu)調到零位后(hou)方可(ke)接(jie)通電源,合閘(zha),開(kai)始升壓。

3、從零開始勻速(su)旋(xuan)轉調(diao)壓(ya)(ya)器手輪升(sheng)(sheng)(sheng)壓(ya)(ya)。升(sheng)(sheng)(sheng)壓(ya)(ya)方(fang)式(shi)有:快速(su)升(sheng)(sheng)(sheng)壓(ya)(ya)法(fa),即(ji)(ji)20s逐(zhu)級升(sheng)(sheng)(sheng)壓(ya)(ya)法(fa);慢(man)速(su)升(sheng)(sheng)(sheng)壓(ya)(ya)法(fa),即(ji)(ji)60s逐(zhu)級升(sheng)(sheng)(sheng)壓(ya)(ya)法(fa);極慢(man)速(su)升(sheng)(sheng)(sheng)壓(ya)(ya)法(fa)供選用。電壓(ya)(ya)從零開始按(an)一定(ding)的(de)(de)升(sheng)(sheng)(sheng)壓(ya)(ya)方(fang)式(shi)和速(su)度(du)上升(sheng)(sheng)(sheng)到(dao)您(nin)所(suo)需(xu)的(de)(de)額(e)定(ding)試(shi)(shi)(shi)驗(yan)電壓(ya)(ya)的(de)(de)75%后,再以(yi)每秒(miao)2%額(e)定(ding)試(shi)(shi)(shi)驗(yan)電壓(ya)(ya)的(de)(de)速(su)度(du)升(sheng)(sheng)(sheng)到(dao)您(nin)所(suo)需(xu)的(de)(de)試(shi)(shi)(shi)驗(yan)電壓(ya)(ya),并密切注(zhu)意(yi)測(ce)量儀表(biao)的(de)(de)及(ji)被試(shi)(shi)(shi)品的(de)(de)情(qing)況(kuang)。升(sheng)(sheng)(sheng)壓(ya)(ya)過程(cheng)(cheng)中或試(shi)(shi)(shi)驗(yan)過程(cheng)(cheng)中如發現測(ce)量儀表(biao)的(de)(de)指示及(ji)被試(shi)(shi)(shi)品情(qing)況(kuang)異常,應立(li)即(ji)(ji)降壓(ya)(ya),切斷(duan)電源(yuan),查(cha)明情(qing)況(kuang)。

4、試驗完(wan)畢后,應在等調壓器返回(hui)至零位,然(ran)后切斷電源。

5、本產品(pin)不得(de)超過額定參數使用。

6、使用(yong)本產品(pin)做高(gao)壓(ya)試驗(yan)時,除熟悉(xi)本說明書外,還(huan)必須嚴格執行國家有關標(biao)準和操作規程。可(ke)參照(zhao)GB311.1 – 97《高(gao)壓(ya)輸(shu)變設(she)備(bei)的絕緣配(pei)合,高(gao)壓(ya)試驗(yan)技術》;《電氣(qi)設(she)備(bei)預防性試驗(yan)規程》等(deng)。

7、控(kong)(kong)制(zhi)箱(xiang)(臺(tai))應(ying)與試驗(yan)變壓(ya)器(qi)配套使用,控(kong)(kong)制(zhi)箱(xiang)(臺(tai))的使用方法(fa),請詳細參(can)閱控(kong)(kong)制(zhi)器(qi)的使用說明書(shu)。

相關產品