一、WBYD2000諧振試驗裝置基本原理
耐壓(ya)試(shi)驗是利用(yong)電(dian)抗(kang)器的(de)電(dian)感與被試(shi)品(pin)電(dian)容組成LC串聯回路,調節(jie)變頻(pin)電(dian)源輸出的(de)電(dian)壓(ya)頻(pin)率,在(zai)(zai)被試(shi)品(pin)上獲得高(gao)電(dian)壓(ya),是當前高(gao)電(dian)壓(ya)試(shi)驗的(de)一種新方法,深受(shou)專(zhuan)家好評,在(zai)(zai)國內外已經(jing)得到廣泛(fan)的(de)使用(yong)。
根據(ju)諧(xie)振原理(li),我們(men)知道當電(dian)抗器(qi)L的感抗值Xl與回(hui)路(lu)中的容抗值Xc相等時,回(hui)路(lu)達到諧(xie)振狀態(tai),此時回(hui)路(lu)中僅回(hui)路(lu)電(dian)阻R消耗(hao)有功功率,而無(wu)功功率則在電(dian)抗器(qi)與試品(pin)(pin)電(dian)容之(zhi)間來回(hui)振蕩,從而在試品(pin)(pin)上產生高(gao)壓。
二、WBYD2000諧振試驗裝置系統構成
全(quan)套試驗(yan)(yan)系統由調頻電(dian)源主機、電(dian)抗器(qi)、分(fen)壓(ya)器(qi)、激勵變(bian)壓(ya)器(qi)和補償電(dian)容(rong)器(qi)(可選器(qi)件)組成(cheng),接(jie)入被試品(pin)后組成(cheng)一(yi)個諧振系統進行交流(liu)耐壓(ya)實驗(yan)(yan)。
主機: 就是一臺幅值和頻率可(ke)調(diao)的正弦波(bo)交(jiao)流(liu)調(diao)頻電源,給諧振回(hui)路提供激勵源,同時提供電壓顯(xian)示、電流(liu)顯(xian)示、計(ji)時、保護、報警(jing)等(deng)功能。
電(dian)抗器(qi):就是一(yi)個(ge)大電(dian)感(gan)線(xian)圈(quan),與被(bei)試品(相當(dang)于(yu)電(dian)容)構成回路(lu),可配置電(dian)抗器(qi)多(duo)節電(dian)抗器(qi),使(shi)用時通過(guo)不(bu)同(tong)的串聯、并聯組合、實(shi)現不(bu)同(tong)的電(dian)感(gan)量以適用不(bu)同(tong)的試驗條件。
分(fen)壓器(qi)(qi):內部通過電(dian)容器(qi)(qi)分(fen)壓,從試品上(shang)高電(dian)壓分(fen)得低電(dian)壓供主(zhu)機測(ce)量、控(kong)制使用。
勵磁變壓器:隔離主機電(dian)源與諧振回路電(dian)源,并升高主機的輸出電(dian)壓。
補(bu)償電(dian)容(rong)器(qi):當試(shi)品電(dian)容(rong)量很小時(shi),如果要實(shi)現(xian)系統諧振(zhen)可能要求(qiu)的電(dian)源頻率超出試(shi)驗標(biao)準的規(gui)定,可在試(shi)品上(shang)并聯一個(ge)補(bu)償電(dian)容(rong),以實(shi)現(xian)試(shi)驗要求(qiu),稱此(ci)電(dian)容(rong)器(qi)為補(bu)償電(dian)容(rong)器(qi)。
三、WBYD2000諧振試驗裝置主要技術性能
功率(lv)電源電壓(ya):AC380V±10%、50Hz;
儀器(qi)電(dian)源:220V±10%、50Hz;
諧振輸出容量:200kVA;
儀器額定電壓:0~200kV;
輸出頻率范圍:30~300Hz;
輸(shu)出電壓(ya)波形(xing):正弦波,波形(xing)畸變(bian)率(lv)<0.5%;
頻率調節靈敏度:0.1Hz,不穩定度≤0.05%;
系統(tong)噪聲:≤60db;
9、系(xi)統測量精(jing)度:<1級;
10.輸出電壓不穩(wen)定:<0.5%;
11.保護響應時(shi)間:1us;
12.電(dian)感非線性度:≤0.05%;;
13.滿功率(lv)輸出下,連續工(gong)作時(shi)間為60min
14.環境溫度:-15℃~+50℃;
15.相對濕度:≤90%RH;
16.海拔(ba)高度:≤2000米。
四、WBYD2000諧振試驗裝置面板及部件名稱
五、WBYD2000諧振試驗裝置操作步驟
1、正(zheng)確連(lian)線,檢查無誤后方可送(song)電。
必(bi)要時工作電(dian)源的跳(tiao)過(guo)現場漏電(dian)保安器(qi),以免不必(bi)要的跳(tiao)閘(zha)。
2、打開電源開關,主機開始工作,液晶屏(ping)顯示版(ban)權頁,該(gai)頁標(biao)明本(ben)裝置的軟件版(ban)本(ben)號。
觸(chu)按確認鍵,進入系(xi)統菜單,該(gai)主菜單下有:試(shi)驗(yan)(yan)(yan)方案、開(kai)始試(shi)驗(yan)(yan)(yan)、試(shi)驗(yan)(yan)(yan)幫助、系(xi)統設(she)置(zhi)、實用工(gong)具和(he)試(shi)驗(yan)(yan)(yan)記錄(lu)等六個子菜單項(xiang)。
3、 系統(tong)設(she)(she)置(zhi)菜單下(xia)有電(dian)(dian)抗器(qi)電(dian)(dian)感、日期時間(jian)設(she)(she)置(zhi)和采(cai)樣系數(shu)(shu)(shu)設(she)(she)置(zhi)等三個子菜單項。按(an)上下(xia)鍵,上下(xia)移動光標系統(tong)參數(shu)(shu)(shu)設(she)(she)置(zhi)菜單項,觸按(an)確定(ding)鈕后,進入(ru)系統(tong)參數(shu)(shu)(shu)設(she)(she)置(zhi)菜單,可以分別(bie)設(she)(she)定(ding)電(dian)(dian)抗器(qi)的(de)電(dian)(dian)感—H、-年-月(yue)-日、-時-分-秒(miao)和電(dian)(dian)壓和電(dian)(dian)流(liu)的(de)采(cai)樣系數(shu)(shu)(shu)也就(jiu)是采(cai)樣倍率,設(she)(she)定(ding)完成后,觸按(an)返(fan)還鍵返(fan)回(hui)上**菜單。
電(dian)抗器電(dian)感(gan)量(liang)的設定(ding):按確定(ding)鍵(jian)選擇到此項,按左右鍵(jian)移動(dong)光標需(xu)要改變(bian)的數位,按上下鍵(jian)改變(bian)數值(zhi),達到所要達到的數值(zhi)按確定(ding)鍵(jian)確認。
日(ri)期時間(jian)的設定:按確(que)定鍵(jian)選擇到此項,按左(zuo)右鍵(jian)移動光(guang)標(biao)需要(yao)改變(bian)的數(shu)位(wei),按上下鍵(jian)改變(bian)數(shu)值,按照所要(yao)設置的年月日(ri)時間(jian)數(shu)值按確(que)定鍵(jian)確(que)認。
采(cai)樣系數的設(she)定(ding)(ding):按確(que)定(ding)(ding)鍵選擇到高(gao)壓/電(dian)流(liu)采(cai)樣系數項,此項為(wei)電(dian)壓或電(dian)流(liu)采(cai)樣倍率的設(she)定(ding)(ding)。一般(ban)(ban)出(chu)廠(chang)前設(she)定(ding)(ding)好了。如需修改(gai),要輸入(ru)密碼。(密碼廠(chang)家與設(she)備一起(qi)提供一般(ban)(ban)設(she)定(ding)(ding)為(wei):188888)
警告:系統默認上一(yi)次電(dian)(dian)抗器(qi)電(dian)(dian)感(gan)、日期(qi)時間和采樣系數(shu)設(she)(she)定(ding)值(zhi)。如果需改(gai)變(bian)要重新設(she)(she)定(ding)。電(dian)(dian)抗器(qi)電(dian)(dian)感(gan)量設(she)(she)定(ding)值(zhi)與實(shi)際(ji)使用的電(dian)(dian)抗器(qi)電(dian)(dian)感(gan)量不(bu)(bu)(bu)對,會導(dao)致試(shi)(shi)驗報告中的被試(shi)(shi)品電(dian)(dian)容量不(bu)(bu)(bu)準。其他并(bing)不(bu)(bu)(bu)會影(ying)響(xiang)。采樣系數(shu)設(she)(she)置(zhi)不(bu)(bu)(bu)正確,會導(dao)致顯示電(dian)(dian)壓電(dian)(dian)流不(bu)(bu)(bu)準將很有可(ke)能會對被試(shi)(shi)品或試(shi)(shi)驗設(she)(she)備(bei)造成損(sun)壞(huai)。
4、試(shi)驗(yan)方案菜單(dan)下有預(yu)置(zhi)(zhi)保(bao)護電(dian)流、找頻(pin)起始頻(pin)率、找頻(pin)結束頻(pin)率、預(yu)定起始功率四個(ge)子菜單(dan)項,分別設(she)定本次試(shi)驗(yan)的保(bao)護電(dian)流、找頻(pin)起始頻(pin)率、找頻(pin)結束頻(pin)率、輸出起始功率,全部設(she)定完成后,觸按(an)返還(huan)鍵進入預(yu)置(zhi)(zhi)試(shi)驗(yan)電(dian)壓和預(yu)置(zhi)(zhi)試(shi)驗(yan)時間設(she)置(zhi)(zhi)菜單(dan)。
可以分(fen)3段(duan)時(shi)間設置(zhi)試(shi)驗(yan)(yan)電(dian)壓和試(shi)驗(yan)(yan)時(shi)間, 實際試(shi)驗(yan)(yan)時(shi),若設定(ding)為(wei)自動(dong)試(shi)驗(yan)(yan), 裝置(zhi)將按設定(ding)的(de)3段(duan)電(dian)壓及(ji)時(shi)間,按順序(xu)分(fen)別加(jia)壓, 全部完成后自動(dong)退出.
如果**段(duan)電壓設為0, 或時間設為0, 那么執行完**段(duan)試驗電壓加壓后退出試驗, 只加壓**段(duan)設定的(de)電壓.
如(ru)果(guo)第三段電壓(ya)設為(wei)0, 或時(shi)間設為(wei)0, 不(bu)執行第三段加壓(ya).
試驗(yan)方(fang)案設(she)(she)置的(de)(de)(de)(de)設(she)(she)定(ding):在試驗(yan)電壓項中(zhong),按(an)確定(ding)單鈕,移(yi)動左右光(guang)標到(dao)需要改變(bian)的(de)(de)(de)(de)數(shu)位(wei),按(an)上下單鈕以(yi)改變(bian)當前數(shu)位(wei)的(de)(de)(de)(de)數(shu)值大小,觸(chu)按(an)返回鈕完成(cheng)(cheng)當前數(shu)位(wei)的(de)(de)(de)(de)數(shu)值設(she)(she)定(ding),依(yi)次(ci)選擇下一項數(shu)值的(de)(de)(de)(de)設(she)(she)定(ding),直至分別(bie)完成(cheng)(cheng)試驗(yan)時間(jian)、起(qi)始(shi)頻率(lv)、起(qi)始(shi)功率(lv)的(de)(de)(de)(de)設(she)(she)置,方(fang)可完成(cheng)(cheng)本次(ci)試驗(yan)的(de)(de)(de)(de)試驗(yan)方(fang)案設(she)(she)置的(de)(de)(de)(de)設(she)(she)定(ding)。
出(chu)廠(chang)默認值:試(shi)驗電(dian)壓 20kV、加(jia)壓時間(jian) 2min、激(ji)勵(li)強度 2%、輸出(chu)電(dian)流20A、頻(pin)率范圍30-300Hz。
5、實用工具菜單(dan)下有
頻(pin)率(lv)計算(suan):在實(shi)驗(yan)前可(ke)對諧振頻(pin)率(lv)進行計算(suan)。只需輸入具體參與試(shi)驗(yan)的電(dian)感、電(dian)容值并按確(que)定鍵(jian)試(shi)驗(yan)頻(pin)率(lv)即直接(jie)生成。
6、開(kai)始試(shi)驗(yan)菜(cai)單(dan)下有自動(dong)試(shi)驗(yan)模式(shi)和手動(dong)試(shi)驗(yan)模式(shi)兩種子菜(cai)單(dan)可(ke)供選擇。
按(an)確認鍵進(jin)入(ru)所選試驗步(bu)驟.
自(zi)動(dong)試(shi)驗(yan)模(mo)式的(de)(de)操作:選中自(zi)動(dong)試(shi)驗(yan)模(mo)式后,觸按菜單鈕進(jin)入正在(zai)自(zi)動(dong)尋找(zhao)(zhao)(zhao)諧(xie)振點(dian)菜單項,裝置在(zai)設定的(de)(de)頻(pin)(pin)(pin)率范圍(wei)(wei)內自(zi)動(dong)尋找(zhao)(zhao)(zhao)諧(xie)振點(dian)(如果被(bei)試(shi)品(pin)電(dian)容C和電(dian)抗器電(dian)感L的(de)(de)實際諧(xie)振頻(pin)(pin)(pin)率不(bu)在(zai)設定的(de)(de)頻(pin)(pin)(pin)率范圍(wei)(wei)內,將找(zhao)(zhao)(zhao)不(bu)到諧(xie)振點(dian),此時(shi)根(gen)據需要調(diao)整(zheng)頻(pin)(pin)(pin)率范圍(wei)(wei)或調(diao)整(zheng)被(bei)試(shi)品(pin)回路(lu)的(de)(de)LC參數)。當找(zhao)(zhao)(zhao)到諧(xie)振點(dian)時(shi),會有聲音提(ti)示。
找到諧振點后,裝置(zhi)自動(dong)進入正(zheng)在(zai)自動(dong)升壓(ya)(ya)菜單項,當(dang)升到試驗電壓(ya)(ya)設定的(de)電壓(ya)(ya)時,裝置(zhi)停止加壓(ya)(ya)。
當裝置(zhi)升到(dao)試(shi)驗(yan)(yan)電(dian)壓設(she)定(ding)的電(dian)壓時(shi),設(she)備停止加(jia)(jia)壓,自(zi)動(dong)進入正在加(jia)(jia)壓試(shi)驗(yan)(yan)菜(cai)單項(xiang),并自(zi)動(dong)記錄試(shi)驗(yan)(yan)的加(jia)(jia)壓時(shi)間(jian),當加(jia)(jia)壓時(shi)間(jian)到(dao)達設(she)定(ding)時(shi)間(jian)時(shi),設(she)備逐(zhu)步降壓退出(chu)試(shi)驗(yan)(yan),完成本次試(shi)驗(yan)(yan),進入試(shi)驗(yan)(yan)結束菜(cai)單項(xiang)。并可選(xuan)擇保存試(shi)驗(yan)(yan)數據(ju)或打印試(shi)驗(yan)(yan)數據(ju)。
試驗時間的(de)(de)一行顯(xian)(xian)示(shi)(shi)末(mo)端,會顯(xian)(xian)示(shi)(shi)[一段(duan)]或(huo)[二(er)段(duan)]或(huo)[三(san)段(duan)]字(zi)樣,表(biao)示(shi)(shi)當前正在進行的(de)(de)加壓試驗是預(yu)置的(de)(de)一段(duan),二(er)段(duan)或(huo)三(san)段(duan).
手動(dong)試(shi)驗(yan)(yan)(yan)模(mo)式(shi)的操(cao)作:選中手動(dong)試(shi)驗(yan)(yan)(yan)模(mo)式(shi)后觸按確定鈕(niu),進入正在試(shi)驗(yan)(yan)(yan)菜單項;手動(dong)按調(diao)頻(pin)鈕(niu),對應的光標隨之改變到(dao)輸出(chu)頻(pin)率項,可(ke)以通過上下左右鍵改變頻(pin)率大小使其試(shi)驗(yan)(yan)(yan)電(dian)壓(ya)逐(zhu)步(bu)升(sheng)高,當升(sheng)到(dao)*高電(dian)壓(ya)時(shi),繼續向上或向下調(diao)整(zheng)頻(pin)率按鈕(niu),直至試(shi)驗(yan)(yan)(yan)電(dian)壓(ya)開始下降;這時(shi)反(fan)調(diao)頻(pin)率,試(shi)驗(yan)(yan)(yan)電(dian)壓(ya)又(you)逐(zhu)步(bu)回升(sheng),上下回調(diao)頻(pin)率,從頻(pin)率的高位到(dao)低(di)位逐(zhu)位調(diao)整(zheng)*高電(dian)壓(ya)值時(shi)的頻(pin)率就是當前的諧(xie)振頻(pin)率。
找到諧振點后,手動按電壓鈕,光標到了輸出(chu)功率(lv),隨之按上(shang)下鍵增加(jia)輸出(chu)功率(lv),試(shi)(shi)驗(yan)電壓也(ye)逐步(bu)升高,當(dang)升到試(shi)(shi)驗(yan)電壓設(she)(she)定電壓值時,裝置停止加(jia)壓,并有屏幕顯示提示和聲(sheng)音提示;自動進入正在加(jia)壓試(shi)(shi)驗(yan)菜單項,并自動記(ji)錄試(shi)(shi)驗(yan)的加(jia)壓時間,當(dang)到達加(jia)壓時間設(she)(she)定時間時,設(she)(she)備(bei)逐步(bu)降(jiang)壓退出(chu)試(shi)(shi)驗(yan),完成本(ben)次試(shi)(shi)驗(yan),進入試(shi)(shi)驗(yan)結束菜單項。
注意(yi):在調(diao)(diao)節(jie)頻(pin)率調(diao)(diao)整鈕的(de)(de)(de)過程中,觸按(an)(an)(an)左(zuo)右(you)鈕,可(ke)以改(gai)變(bian)頻(pin)率調(diao)(diao)節(jie)的(de)(de)(de)速(su)度(du)實現粗細調(diao)(diao)的(de)(de)(de)切換。在調(diao)(diao)節(jie)電壓(ya)調(diao)(diao)整鈕的(de)(de)(de)過程中,向(xiang)下觸按(an)(an)(an)左(zuo)右(you)鈕,可(ke)以改(gai)變(bian)電壓(ya)的(de)(de)(de)升降的(de)(de)(de)速(su)度(du)實現粗細調(diao)(diao)的(de)(de)(de)切換。觸按(an)(an)(an)調(diao)(diao)頻(pin)、調(diao)(diao)壓(ya)鈕,實現調(diao)(diao)頻(pin)與調(diao)(diao)壓(ya)間的(de)(de)(de)切換。
7、進入(ru)試驗記錄(lu)查詢菜單(dan)項,查詢以往和(he)當前試驗數據。選擇(ze)上下鍵(jian)(jian)翻看前一(yi)組數據后(hou)一(yi)組數據;選擇(ze)左右鍵(jian)(jian)可選擇(ze)打印或(huo)刪除當前頁(ye)的內(nei)容。
125/456為試驗數據庫指針,分(fen)子是(shi)試驗數據的(de)在數據庫的(de)順序數,分(fen)母是(shi)當(dang)前的(de)數據總數,*多(duo)可儲存999組試驗數據。
8、裝(zhuang)置(zhi)和試驗狀態(tai)菜(cai)單提(ti)示:設(she)備的(de)使(shi)用和升壓和耐壓試驗過(guo)程中,如果出(chu)現影響試驗設(she)備、被試驗設(she)備以及操作人(ren)的(de)**情況(kuang),設(she)備可能出(chu)現自動(dong)保(bao)護轉臺,并在屏幕有相應的(de)提(ti)示。
不(bu)能諧(xie)振(zhen):如(ru)果諧(xie)振(zhen)點(dian)(dian)不(bu)在(zai)諧(xie)振(zhen)頻率設置的范圍內;系統連線(xian)不(bu)正確等現(xian)象,裝(zhuang)置將找不(bu)到諧(xie)振(zhen)點(dian)(dian),這(zhe)時裝(zhuang)置和試驗(yan)狀態菜(cai)單中的不(bu)能諧(xie)振(zhen)項被反白并閃(shan)爍(shuo)。
輸出(chu)保(bao)護(hu)(hu):如果裝(zhuang)置的電(dian)源輸出(chu)電(dian)流(liu)大(da)于輸出(chu)保(bao)護(hu)(hu)設定的電(dian)流(liu)值,裝(zhuang)置自動保(bao)護(hu)(hu),這時裝(zhuang)置和試(shi)驗(yan)狀態(tai)菜單中的輸出(chu)保(bao)護(hu)(hu)項被反白并閃爍。
試(shi)驗(yan)(yan)中止:如(ru)果在試(shi)驗(yan)(yan)升(sheng)壓(ya)或加(jia)壓(ya)過程出現(xian)閃(shan)絡現(xian)象,裝(zhuang)置自動保(bao)護(hu)(hu),這時裝(zhuang)置和(he)試(shi)驗(yan)(yan)狀態菜單中的輸出保(bao)護(hu)(hu)項被反白并閃(shan)爍。
9、試驗幫助內容(rong)包括(kuo)五大項分別(bie)為(wei):1.版本信息(xi)2.接線示(shi)意3.使用說(shuo)明(ming)4.常(chang)見問題5.參考資料.如常(chang)見問題FAQ分五幅畫面(mian)顯示(shi)、各種被試品(pin)電力電纜(lan)、變壓器、發電機電容(rong)參數的查(cha)詢(xun):
接(jie)線(xian)示意圖:
10、設(she)(she)備出廠(chang)(chang)參(can)數設(she)(she)置是生產廠(chang)(chang)家的出廠(chang)(chang)設(she)(she)置參(can)術和(he)校驗參(can)數,不適當的設(she)(she)置和(he)修(xiu)改會(hui)影(ying)響設(she)(she)備性能和(he)高壓試驗的**性,未經廠(chang)(chang)家授權密碼,無法修(xiu)改。
警告:正(zheng)常(chang)試驗(yan)狀態下(xia),按(an)返回鍵即(ji)可中(zhong)止試驗(yan)。中(zhong)止或結(jie)束試驗(yan)后,應(ying)分離刀閘切斷(duan)電源。在升壓或加壓過程中(zhong),非緊(jin)急(ji)情況,不要按(an)下(xia)急(ji)停鍵。
六、本說明書(shu)的專(zhuan)屬名(ming)詞(ci)的定義(yi)
自動試驗:高壓試驗全過程(cheng)由(you)主機按程(cheng)序和(he)預置參數自動完成。
自動(dong)調諧(xie):調諧(xie)由主機(ji)按程序自動(dong)完成(cheng),升壓手動(dong)完成(cheng)。
手動試驗:尋找諧振點和升壓均為手動,通過(guo)面板旋鈕完成(cheng)。
系(xi)統參數設(she)置是指對設(she)備部件參數的(de)設(she)置。
試驗(yan)參數(shu)設置是(shi)指對試驗(yan)過程參數(shu)的設置。
試驗模式選擇是(shi)指(zhi)對試驗模式的選擇。
試驗結果查詢(xun)是指(zhi)對試驗數(shu)據的(de)查詢(xun)。
分(fen)壓(ya)器變比是指對分(fen)壓(ya)器的分(fen)壓(ya)比設置。
電(dian)抗(kang)(kang)器電(dian)感(gan)是指對電(dian)抗(kang)(kang)器電(dian)抗(kang)(kang)值的設(she)置。
激(ji)勵變變比是指對勵磁變壓器的變比設置。
設置電壓(ya)是高壓(ya)試驗時的(de)保護電壓(ya)設置。
試(shi)驗(yan)(yan)(yan)電壓(ya)(ya)是高(gao)壓(ya)(ya)試(shi)驗(yan)(yan)(yan)時的試(shi)驗(yan)(yan)(yan)電壓(ya)(ya)。
加壓時間是施加試驗(yan)電壓的(de)時間。
激勵強度是指(zhi)主機電源輸出的大小。
輸(shu)出(chu)電流(liu)是主機電源的(de)輸(shu)出(chu)電流(liu)。
頻(pin)率(lv)范(fan)圍是試驗的頻(pin)率(lv)范(fan)圍。
自(zi)動試(shi)驗模式是指試(shi)驗過(guo)程全(quan)部自(zi)動完成。
自(zi)動(dong)調諧模(mo)式(shi)是指自(zi)動(dong)尋找諧振點后,手(shou)動(dong)加壓(ya)完成試驗。
手動試驗(yan)模式全(quan)部由人工完成試驗(yan)過程。
未接(jie)地線(xian)主機電源為接(jie)地。
不能諧振(zhen)未能找到諧振(zhen)點。
輸出(chu)保護主(zhu)機電源輸出(chu)電流大(da)于整(zheng)定電流。
試驗中止指在升壓或加壓過程(cheng)裝置自(zi)動保護(hu)。
設備(bei)出廠(chang)參數設置是廠(chang)家對設備(bei)有關參數的設置。
確認鍵:確認當(dang)前操(cao)作(zuo)。
返回(hui)鍵:返回(hui)上**菜單。
七、變(bian)頻(pin)電源技術(shu)參數:
1.額(e)定輸出容量(liang):15kvA;
2.儀器電(dian)源(yuan):220v±10% 50Hz;
功率電源(yuan):380v±10% 50Hz;
3.額定輸(shu)入(ru)電流:39.5A;
4.額(e)定輸(shu)出電壓(ya):0-340v可調(diao)、單相、輸(shu)出電壓(ya)不穩定度(du)0.05%;
5.額(e)定輸出電流:44A;
6.頻(pin)率調(diao)節范(fan)圍:25~320Hz;
7.額定(ding)容量下(xia)連續運行為規定(ding)工作時間(jian)下(xia)*高溫升≤60K;
8.顯示以下(xia)參數:
a.經(jing)變頻(pin)(pin)輸(shu)出的頻(pin)(pin)率(lv)、電(dian)壓、電(dian)流(liu);
b.過壓保護(hu)電壓值,并(bing)可(ke)任意整(zheng)定(ding),當成套裝(zhuang)置的輸出電壓值達到(dao)保護(hu)整(zheng)定(ding)時,可(ke)自動切(qie)除(chu)成套裝(zhuang)置;
c.過流保護(hu):當調頻電(dian)源(yuan)的(de)輸出(chu)電(dian)流達到保護(hu)整定值(zhi)時(shi),可自動切除(chu)成套裝置;
d.擊穿(chuan)保(bao)護:當高(gao)壓側發生對地閃絡(luo)時,可自動切除成套裝置(zhi),裝置(zhi)帶有隔離裝置(zhi),可確(que)保(bao)設(she)備(bei)和人身不受損害;
e.具有全電(dian)壓輸出保護,在調(diao)壓過(guo)程中(zhong),一旦調(diao)壓失控,調(diao)頻電(dian)源(yuan)立即閉(bi)鎖;
9.可實現以(yi)下操作:
a.頻(pin)率(lv)的(de)調(diao)節,上(shang)升和(he)下(xia)降頻(pin)率(lv)調(diao)節分粗調(diao)和(he)細(xi)調(diao)兩種,并可自動尋找試驗(yan)諧(xie)振(zhen)點(dian),保(bao)證(zheng)諧(xie)振(zhen)頻(pin)率(lv)在整(zheng)個試驗(yan)過程中不發(fa)生漂移;
b.帶有設置(zhi)電(dian)壓、設置(zhi)時間,電(dian)壓自(zi)動上升到設置(zhi)值(zhi)而停止并自(zi)動計時;
c.帶有各(ge)種保護功能的整(zheng)定(ding)(ding)按鈕,可在面板上對各(ge)種保護值進(jin)行整(zheng)定(ding)(ding);
d.帶有手動(dong)試驗(yan)功能和自動(dong)試驗(yan)功能;
e.帶(dai)有試(shi)驗數(shu)據打印(yin)功能。
八、勵磁變壓器(qi)技術(shu)參數(shu):
1.結(jie)構(gou)形式(shi):干式(shi);
2.額定(ding)容量:15kVA;
3.輸入電(dian)壓(ya):0~340V;
4.輸出電壓:四組并(bing)聯3.75KV;四組串聯15KV;二(er)串二(er)并(bing)7.5KV;
5.輸出電流(liu):四組并聯(lian)4A;四組串聯(lian)1A;二串二并2A;
6.工作(zuo)頻率(lv)范圍:30~300Hz;
勵(li)磁變壓器的接線端(duan)子,如圖所示:
1.輸出端(duan)尾—與接地端(duan)連(lian)接。
2.輸出端頭—與電抗(kang)器連接。
3.接(jie)地(di)端—與(yu)變頻電源(yuan)、分壓器及被試品共(gong)同接(jie)地(di)。
4.輸入端(duan)—接(jie)調頻電源功率輸出(chu)端(duan)。
九、諧振電抗器技術參數:
額定容量:55KVA;
額定電壓:55kV;
額定電流:1.5A;
電 感 量:160H;
品質因數:Q≥30
采用(yong)環氧(yang)干(gan)式(shi)。
7.接線端了如(ru)圖所示:
a.高壓側接線端子(zi)—與(yu)被試(shi)品高壓端連(lian)接。
b.低壓(ya)側(ce)接(jie)線端(duan)子—與勵磁變輸出(chu)端(duan)連接(jie)。
c.多臺電(dian)(dian)抗器(qi)串(chuan)聯時上(shang)節(jie)的低壓(ya)側(ce)與(yu)下節(jie)高壓(ya)側(ce)連接。諧振電(dian)(dian)抗器(qi)采用(yong)多臺串(chuan)聯或(huo)并聯的連接方(fang)式(shi)。
8.額定(ding)容量下連續運行為(wei)規(gui)定(ding)工作時(shi)間下,電抗器對空氣的溫升不(bu)大于(yu)60K;
9.性能及(ji)特點:電抗器設(she)計干式、環氧(yang)澆鑄,電抗器可以(yi)自由方便疊裝。環氧(yang)樹脂絕緣筒外殼,具有足(zu)夠的(de)電氣、機械強度,必要的(de)散熱能力以(yi)及(ji)油熱脹(zhang)冷縮的(de)裕度。外殼上下蓋板,顏色為橘紅色。
十(shi)、電(dian)容分壓器技(ji)術參(can)數:
額定電壓:200kV;
工作(zuo)頻率(lv):30~300Hz;
分壓比(bi):2000:1;
分(fen)壓比誤差:1%;
電容分壓器(qi)接(jie)線端子如圖所示:
高(gao)壓(ya)端—與電抗器高(gao)壓(ya)側及(ji)被試品(pin)高(gao)壓(ya)側相連。
測量插(cha)座—采用專配的(de)測量電(dian)纜與控制箱背(bei)板測量輸入(ru)端連接。
接(jie)(jie)(jie)地(di)端—采用專配接(jie)(jie)(jie)地(di)線按(an)接(jie)(jie)(jie)線圖指示接(jie)(jie)(jie)地(di)。
4.性能及特點:
a.額定(ding)電壓下可連續運(yun)行2小時(shi)。
b.在30~300Hz范圍內,其(qi)精度和穩定度保持不變。
c.在(zai)20℃溫度下電容(rong)分(fen)壓器介質損耗值≤0.0025
d.電容分壓(ya)器配有支撐底架,具有足夠的(de)穩定(ding)性。
e.電壓測量通過專用測試(shi)引線引至(zhi)調(diao)頻電源進行(xing)測量。
試驗接線(xian)圖(tu):
110kv主變、GIS試驗接線
35kv電(dian)纜試驗接線圖
10kv電纜試驗接線圖
十(shi)二、設備保(bao)存(cun)和維護
1、存放于干(gan)燥、清潔場地,防(fang)止雨(yu)水、灰塵進(jin)入部(bu)件內(nei)部(bu);
2、如若長期不使用,正常天氣至少2個月(yue)應(ying)通電(dian)一(yi)次(ci)時(shi)間不少于半小時(shi),雨(yu)季及潮濕期應(ying)每隔一(yi)個月(yue)通電(dian)一(yi)次(ci),通電(dian)時(shi)間半小時(shi),以驅除設備內的潮氣防止(zhi)電(dian)子元器件的銹蝕,影響正常使用。
3、定(ding)期檢查裝(zhuang)置各部件(jian),確保各接頭緊(jin)固無松動;
4、更換打(da)印紙,機器采用熱(re)敏打(da)印紙并(bing)且是前換紙式當需要換紙時只要按POST鍵(jian)鈕打(da)印紙艙門就會(hui)打(da)開可以(yi)將新(xin)打(da)印紙裝入;
十三(san)、常(chang)見故障排除
故障(zhang)現象
|
發 生 原 因
|
排 除 方 法(fa)
|
找不到諧振點
|
接線有誤。
輸出(chu)開(kai)關(guan)未開(kai),;
3、做GIS時(shi)PT二次(ci)回路未打開(kai);
4、試品(pin)Q值太(tai)低;
5、起始激勵(li)功率太低;
6、試驗回路(lu)(lu)有短路(lu)(lu)現(xian)象;
7、找頻范圍不對。
|
退出(chu)試驗狀態,合上輸出(chu)開(kai)關(guan),檢查接線(xian);打開(kai)PT二次回路;
調高起始(shi)功率(∠30%);
用兆(zhao)歐表測量(liang)試品絕緣
重新設置找頻范(fan)圍
|
諧振后,電壓升不上去
|
1、試品(pin)Q值太(tai)低;
2、激(ji)勵電壓(ya)不夠;
3、電抗器(qi)底部有(you)鐵(tie)磁物(wu)體;
4、3次諧波諧振。
|
檢(jian)查(cha)試品;
改變(bian)激勵變(bian)壓器繞組接法,提高勵磁電壓
絕(jue)緣筒(tong)架高電抗器或離開鐵磁物體。
|
主機自動(dong)復(fu)位
|
供電電源容量不夠(gou);
電源(yuan)引(yin)線(xian)過長(chang)或線(xian)徑過小;
接頭處接觸**;
供電電壓波(bo)動;
按鍵死接觸。
|
增加(jia)供(gong)電(dian)電(dian)源容量;
換較粗導線,減小導線長度;
檢查接(jie)頭(tou);
減小供電(dian)電(dian)壓波動(dong)。
|
開機后線(xian)路跳閘
|
線(xian)路(lu)漏(lou)電保護器(qi)較為敏感;
空氣開(kai)關容量不(bu)夠。
|
跨過(guo)漏(lou)電(dian)保護器或空(kong)氣開關(guan)的接(jie)線;
改換較大容量的空氣開關。
|
電壓跌落(luo)
|
試(shi)品(pin)放電或擊穿
|
檢查試品
|
輸(shu)出短路
|
電流超(chao)過本機限流值(zhi)。
|
檢(jian)查接線和試(shi)品。
|
試品電壓不準
|
分壓比設置錯誤(wu)或分壓器信號(hao)傳輸有問題(ti)。
|
重(zhong)設分壓比或(huo)檢(jian)查(cha)分壓器接線(xian)。
|
電(dian)壓閃變(bian)
|
試驗電壓劇烈波動,變化率超過本機限定(ding)值。
|
檢查供電電源電壓穩定(ding)性或試品參數的變化。
|
回路無(wu)電流
|
|
檢查(cha)接線和(he)試品。
|
未接(jie)好地線
|
|
檢查接(jie)(jie)地(di)線和地(di)樁,按說明書要求連接(jie)(jie)。
|
試品(pin)過電壓
|
手動升壓太快或失(shi)控(kong)。
|
改變調(diao)壓步距或(huo)改用(yong)自動升(sheng)壓 。
|
系(xi)統不諧振
|
接線有(you)誤或試(shi)品Q值太(tai)低。
|
檢查接線和試品
|
十四(si)、常用設備(bei)資料參考
交(jiao)聯聚乙烯電(dian)纜單位長(chang)度電(dian)容量
電纜導體截面積(平方毫(hao)米(mi))
|
電 容 (μ/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
1×35
|
0.212
|
0.173
|
0.152
|
|
|
1×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
1×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
1×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
1×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
1×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
1×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
1×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
1×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
1×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
1×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
1×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
2、交聯(lian)聚乙烯電纜單位長度(du)電容量
電(dian)纜(lan)導體(ti)截面積(平方毫米)
|
電(dian) 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
3×35
|
0.212
|
0.173
|
0.152
|
|
|
3×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
3×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
3×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
3×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
3×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
3×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
3×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
3×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
3×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
3×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
3×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
3、交聯(lian)聚乙烯電纜單位長(chang)度電容量
電(dian)纜導體截(jie)面積(平方毫米)
|
電(dian) 容(rong) (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
64/110kV
|
128/220kV
|
3×240
|
0.129
|
|
3×300
|
0.139
|
|
3×400
|
0.156
|
0.118
|
3×500
|
0.169
|
0.124
|
3×630
|
0.188
|
0.138
|
3×800
|
0.214
|
0.155
|
3×1000
|
0.231
|
0.172
|
3×1200
|
0.242
|
0.179
|
3×1400
|
0.259
|
0.190
|
3×1600
|
0.273
|
0.198
|
3×1800
|
0.284
|
0.297
|
3×2000
|
0.296
|
0.215
|
3×2200
|
|
0.221
|
3×2500
|
|
0.232
|
4、60kV級(ji)全絕(jue)緣變(bian)壓器的電容(rong)(pF)
類(lei) 型
|
變 壓(ya) 器 容 量 kVA
|
630
|
2000
|
3150
|
6300
|
8000
|
1600
|
高壓-地
|
2700
|
4100
|
4600
|
5900
|
7000
|
8200
|
低壓-地
|
4200
|
6600
|
7900
|
10000
|
11000
|
15300
|
對于表(biao)中沒有的產品,可根據表(biao)中的上、下(xia)容(rong)量(liang)近(jin)似地估算。同容(rong)量(liang)的雙繞(rao)組變壓器,其繞(rao)組電容(rong)要比三繞(rao)組產品小(xiao)。
5、110kV級中性點分級絕緣變壓(ya)器的電(dian)容(pF)
類 型
|
變(bian) 壓(ya) 器 容(rong) 量kVA
|
50000
|
31500
|
20000
|
10000
|
5600
|
高壓-中(zhong)壓、低壓、地
|
14200
|
11400
|
8700
|
6150
|
4200
|
中壓-高壓、低壓、地
|
24800
|
11800
|
13200
|
9600
|
-
|
低壓(ya)-高壓(ya)、中壓(ya)、地(di)
|
19300
|
19300
|
12000
|
9400
|
6800
|
6、220kV級(ji)中性(xing)點(dian)非全級(ji)絕緣部分變壓(ya)器的(de)電容(pF)
試(shi) 品(pin) 型(xing) 號
|
SEPSL-63000
|
SSPSL-120000
|
SSPSL-240000
|
類(lei) 型
|
高壓(ya)-中(zhong)壓(ya)、低壓(ya)及(ji)地
|
12100
|
13500
|
17050
|
中壓(ya)(ya)-高(gao)壓(ya)(ya)、低壓(ya)(ya)及地(di)
|
18500
|
19700
|
23260
|
低(di)壓-高壓、中壓及地
|
18200
|
23600
|
29940
|
試 品 型 號
|
SFPL-240000
|
SFP-360000
|
SFPSZL-120000
|
類 型
|
高壓(ya)(ya)-中(zhong)壓(ya)(ya)、低(di)壓(ya)(ya)及地(di)
|
32230
|
33910
|
38020
|
中壓(ya)(ya)-高壓(ya)(ya)、低壓(ya)(ya)及地
|
-
|
-
|
23260
|
低壓(ya)-高壓(ya)、中壓(ya)及地
|
22470
|
23790
|
22160
|
7、油浸(jin)式電(dian)力變壓(ya)器交流試驗(yan)電(dian)壓(ya)
額定電壓
(k V)
|
*高工(gong)作
電壓(k V)
|
線端交流試(shi)驗電壓值(kV)
|
中性(xing)點交(jiao)流試驗電壓值(kV)
|
全部更(geng)換繞組
|
部分更換繞(rao)組或(huo)交(jiao)接(jie)
|
全部更換繞組
|
部分(fen)更換繞(rao)組或(huo)交接
|
<1
|
≤1
|
3
|
2.5
|
3
|
2.5
|
3
|
3.5
|
18
|
15
|
18
|
15
|
6
|
6.9
|
25
|
21
|
25
|
21
|
10
|
11.5
|
35
|
30
|
35
|
30
|
15
|
17.5
|
45
|
38
|
45
|
38
|
20
|
23.0
|
55
|
47
|
55
|
47
|
35
|
40.5
|
85
|
72
|
85
|
72
|
110
|
126.0
|
200
|
170(195)
|
95
|
80
|
220
|
252.0
|
360
|
306
|
85
|
72
|
395
|
336
|
(200)
|
(170)
|
500
|
550.0
|
630
|
536
|
85
|
72
|
680
|
578
|
140
|
120
|
8、部分型號發電機(ji)定子繞組的單相(xiang)對地電容量
類別
|
發 電(dian) 機
|
型號
|
生產(chan)廠(chang)家
|
額(e)定(ding)容量(MW)
|
額定電(dian)壓(kV)
|
相電容(mF)
|
火
力
發
電(dian)
機
|
QFS-125-2
|
上海電機廠
|
125
|
13.8
|
0.08-0.12
|
QFSN-200-2
|
哈(ha)爾濱電機廠
|
200
|
15.75
|
0.19-0.21
|
QFQS-200-2
|
東方電機廠
|
200
|
15.75
|
0.1928-0.21
|
QFQS-200-2
|
北京重型電機廠
|
200
|
15.75
|
0.18-0.19
|
QFS-300-2
|
上海電機廠
|
300
|
18.0
|
0.16-0.20
|
QFSN-300-2
|
上(shang)海電機廠(chang)
|
300
|
18.0
|
0.18-0.20
|
ATB-2
|
美(mei)國GE公司
|
352
|
23.0
|
0.268(設(she)計值(zhi))
|
TBB-320-2
|
(前蘇聯(lian))
|
320
|
20.0
|
0.31
|
2-105×234
|
美國西屋公司(si)
|
600
|
20.0
|
0.2(工廠試驗值)
|
50WT23E-138
|
ABB
|
600
|
22.0
|
0.253(設計值)
|
水 發(fa)
力 電(dian)
機(ji)
|
|
|
72.5 - 85
|
10.5
|
0.694
|
|
|
300
|
15.75
|
1.7-2.5
|
|
|
400
|
18.0
|
2-2.5
|
9、同步(bu)發電機定子繞組交流試驗電壓
1
|
全(quan)部(bu)更換(huan)定子繞組并修好后的試驗電壓
|
容量kW或kVA
|
小于(yu)10000
|
10000及以上
|
額定電壓Un (V)
|
36以上
|
6000以下
|
6000~18000
|
18000以上
|
試驗電壓V
|
2Un+1000但*低為(wei)1500
|
2.5Un
|
2Un
+3000
|
按專門協(xie)議
|
2
|
大修(xiu)前或局部更換(huan)定子繞組并(bing)修(xiu)好(hao)后的試驗電(dian)壓
|
運行(xing)20年及以(yi)下者
|
1.5 Un
|
運行20年以上與架空線路直接連接者
|
1.5 Un
|
運(yun)行20年以上不(bu)與架(jia)空線路直接連(lian)接者
|
(1.3~1.5)Un
|
十五、設備成(cheng)套(tao)性(xing):
變頻電(dian)源 1臺
勵磁變壓器 1臺(tai)
電抗器 4臺
電容(rong)分(fen)壓器(qi) 1臺(tai)
附件及(ji)測(ce)試線 1套(tao)
支架 15KV 1只
均壓罩(zhao) 200KV 2只
絕緣底板 2塊
一、產(chan)品概述
YDQC系列(lie)輕(qing)型(xing)交直(zhi)(zhi)流高(gao)壓(ya)(ya)試驗(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)器(qi)是在同類(lei)產(chan)品YDJ(G)型(xing)高(gao)壓(ya)(ya)試驗(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)器(qi)的基礎上,按試驗(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)器(qi)國家標準(zhun)ZBK41006—89要求,經改進后生產(chan)的一種新型(xing)產(chan)品,本系列(lie)產(chan)品具有體積小(xiao)、重(zhong)量輕(qing)、結構緊湊(cou)、功能齊全、使用(yong)方便等特(te)點。實用(yong)于電(dian)力、工(gong)礦、科研(yan)等部門(men),對各種高(gao)壓(ya)(ya)電(dian)氣設備、電(dian)氣元(yuan)件(jian)、絕緣材料進行工(gong)頻耐壓(ya)(ya)試驗(yan)(yan)(yan)和直(zhi)(zhi)流泄漏試驗(yan)(yan)(yan),是高(gao)壓(ya)(ya)試驗(yan)(yan)(yan)中必不(bu)可少的儀器(qi)。
二、產品結構
YDQC系(xi)列輕(qing)型高壓(ya)(ya)(ya)試驗變壓(ya)(ya)(ya)器(qi)(qi)鐵芯(xin)(xin)為單框式。線(xian)圈(quan)采用同芯(xin)(xin)圓筒多層塔式結構,初級低壓(ya)(ya)(ya)繞(rao)組繞(rao)在鐵芯(xin)(xin)上,次級高壓(ya)(ya)(ya)繞(rao)組繞(rao)在低壓(ya)(ya)(ya)繞(rao)組外側(ce),這種同軸布置減少(shao)了繞(rao)組間(jian)的(de)藕合損(sun)耗。高壓(ya)(ya)(ya)硅堆用特殊(shu)工藝封裝在套管內(nei),產(chan)品(pin)的(de)外殼制(zhi)成與(yu)器(qi)(qi)芯(xin)(xin)配合較(jiao)佳(jia)的(de)八角形(xing)結構,整體外型美觀大方。其(qi)內(nei)外部(bu)結構見圖(tu)1。
1-均壓(ya)球;2-硅堆短(duan)路桿;3-高壓(ya)套管(guan);4-油(you)閥;5-殼體;6、7-調(diao)整電壓(ya)輸入a、x端(duan)子(zi)(zi);8、9-儀(yi)表測量E、F端(duan)子(zi)(zi);10-高壓(ya)尾X端(duan)子(zi)(zi);11-變壓(ya)器外殼接(jie)地端(duan);12-高壓(ya)輸出(chu)A端(duan)子(zi)(zi);13-高壓(ya)整流硅堆;14-內部均壓(ya)環;15-變壓(ya)器鐵芯;16-初級低壓(ya)繞組(zu)(zu);17-測量儀(yi)表繞組(zu)(zu);18-二次級高壓(ya)繞組(zu)(zu);19-變壓(ya)器油(you)。
三、工作原(yuan)理
YDQC系列輕(qing)型高壓(ya)(ya)(ya)試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)器(qi)(qi)為單相變壓(ya)(ya)(ya)器(qi)(qi),聯結組標號(hao)II。單臺(tai)高壓(ya)(ya)(ya)試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)器(qi)(qi)的工作(zuo)(zuo)過程,用交流220V(10KVA以(yi)上為380V)電(dian)(dian)(dian)壓(ya)(ya)(ya)接入電(dian)(dian)(dian)源(yuan)控(kong)制箱(臺(tai)),經電(dian)(dian)(dian)源(yuan)控(kong)制箱(臺(tai))內自藕調壓(ya)(ya)(ya)器(qi)(qi)(50KVA以(yi)上調壓(ya)(ya)(ya)器(qi)(qi)外附)調節(jie)0~200V(10KVA以(yi)上0~400V)電(dian)(dian)(dian)壓(ya)(ya)(ya)至試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)器(qi)(qi)的初(chu)級繞(rao)組,根據電(dian)(dian)(dian)磁感應原(yuan)理(li),在試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)器(qi)(qi)高壓(ya)(ya)(ya)繞(rao)組可獲得試(shi)驗(yan)(yan)所需的高電(dian)(dian)(dian)壓(ya)(ya)(ya)。其工作(zuo)(zuo)原(yuan)理(li)圖見圖2所示(shi)。
1、單(dan)臺YDQC高壓試驗變壓器工(gong)作(zuo)原理示意圖
在試驗變壓(ya)器中(zhong):a、x為(wei)(wei)低壓(ya)輸(shu)入端;A、X 為(wei)(wei)高壓(ya)輸(shu)出端;E、F為(wei)(wei)儀表測(ce)量端。
2、單臺交直流兩用型高壓試驗變壓器工作原理見圖3。圖中所示:高壓套管內裝有高壓硅堆,串接在高壓回路中作高壓整流,以獲得直流高電壓。當用一短路桿將高壓硅堆短接時,可獲得交流高電壓,其狀態為交流輸出;反之在抽出短路桿時,其狀態為直流輸出。
3、三臺高壓試驗變壓器串激獲得更高電壓原理見圖4,串激高壓試驗變壓器有很大的優越性,因為整個試驗裝置由多個單臺串激式試驗變壓器組成,單臺試驗變壓器有著體積小、重量輕、便于運輸的特點,它既可以串接成高出幾倍的單臺試驗變壓器輸出電壓組合使用,又可以分開單獨使用。整套試驗裝置投資小、經濟實惠。圖3所示:在三臺串激式試驗變壓器串激使用中,單臺試驗變壓器B1、B2、B3的輸出電壓都是U,**、二級的試驗變壓器內部都有一個激磁繞組,分別為A1、C1 和A2、C2。當控制電壓加在第**試驗變壓器B1的初級繞組a1、x1上,激磁繞組A1、C1給予試驗變壓器B2初級繞組供電,**級試驗變壓器B2的激磁繞組A2、C2給試驗變壓器B3的初級繞組供電。由于第**試驗變壓器B1的高壓尾及殼體接地,**、三級的試驗變壓器B2和B3對地有絕緣支架的隔離,這樣試驗變壓器B1、B2、B3對地輸出電壓分別為1U、2U、3U。
B1、B2、B3- 串激式高壓變壓器;1U、2U、3U-各級對地電壓;
PV- 高壓示值(zhi)表(KV); ZJ1、ZJ2-絕(jue)緣支架。
四、使用方(fang)法及注意事項
1、YDQC高壓(ya)(ya)試驗(yan)(yan)變壓(ya)(ya)器(qi)做工頻(pin)耐壓(ya)(ya)試驗(yan)(yan)使用(yong)接(jie)線方法見圖5。做工頻(pin)耐壓(ya)(ya)試驗(yan)(yan)前,先根(gen)據(ju)試驗(yan)(yan)變壓(ya)(ya)器(qi)的(de)(de)額定容(rong)量(liang)選擇好(hao)限(xian)流電(dian)阻(zu),(水(shui)電(dian)阻(zu))的(de)(de)阻(zu)值,再根(gen)據(ju)被(bei)試品需加的(de)(de)高壓(ya)(ya)電(dian)壓(ya)(ya)值調整好(hao)放電(dian)球(qiu)隙的(de)(de)球(qiu)間距,為了提高對被(bei)試品施(shi)加電(dian)壓(ya)(ya)的(de)(de)測(ce)量(liang)精(jing)度(du),應在高壓(ya)(ya)側接(jie)入FRC阻(zu)容(rong)分(fen)壓(ya)(ya)器(qi)來測(ce)量(liang)電(dian)壓(ya)(ya)。
R1、R2- 限流電(dian)阻; Qx- 放電(dian)球隙(xi); Zx- 被試品;
FRC- 阻容分壓器; V- 分壓器高壓表。
按照圖4、結合圖2所進行的工頻耐壓試驗接好工作線路,試驗變壓器的高壓繞阻的X端(高壓尾)、儀表測量繞組的F端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
用三臺試驗變壓器串激做工頻耐壓試驗時、**、三級試驗變壓器的初級繞組X端,儀表測量繞組的F端,以及高壓繞組的X端(高壓尾)均接本級試驗變壓器的外殼,**、三級試驗變壓器的主體必須放置在絕緣支架上。除第**以外、**、三級試驗變壓器的主體不要接地線。其接線方式見圖3所示。
接電源前,電源控制箱(臺)的調壓器必須調到零位。接通電源后,綠色指示燈亮,按一下啟動按鈕,紅色指示燈亮,表示試驗變壓器已接通控制電源,開始升壓。
從零位開始按順時針方向勻速旋轉調壓器手輪升壓。(升壓方式有:快速升壓法,即20S逐級升壓法,慢速升壓法,即60S逐級升壓法,極慢速升壓法供選用)電壓從零開始按選定的升壓速度升到您所需額定試驗電壓的75%后,再以每秒2%額定試驗電壓的速度升到您所需試驗電壓,并密切注意測量儀表的指示以及被試品的情況,被試品施加電壓的時間到后。應在數秒內勻速將調壓器返回,高壓降至1/3試驗電壓以下,按一下停止按鈕,高壓、低壓輸出停止,然后切斷電源線,試驗完畢。
工頻耐壓(ya)試驗操作過(guo)程(cheng)注(zhu)意事項(xiang)
1、試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
2、被試品主要部位應**干凈,保持**干燥,以免損壞被試品和帶來試驗數值的誤差。
3、對大型設備的試驗,一般都應先進行試驗變壓器的空升試驗,即不接試品時升壓至試驗電壓,以便校對好儀表的指示精度,調整好放電球隙的球間距。
4、做耐壓試驗時升壓速度不能過快,并防止突然加壓,例如調壓器不在零位的突然合閘,也不能突然斷電,一般應在調壓器降至零位時分閘。
5、在升壓或耐壓試驗過程中,如發現下列不正常情況,1 電壓、電流表指針擺動很大,2 被試品發出不正常響聲,3 發現絕緣有燒焦或冒煙現象,應立即降壓,切斷電源,停止試驗并查明原因。
6、使用本產品做高壓試驗時,除熟悉本說明書外,還必須嚴格執行國家有關標準和操作規程。
2、YDQ交直(zhi)流(liu)(liu)(liu)(liu)兩用高(gao)壓(ya)(ya)(ya)(ya)試驗(yan)變壓(ya)(ya)(ya)(ya)器做直(zhi)流(liu)(liu)(liu)(liu)耐壓(ya)(ya)(ya)(ya)和泄(xie)(xie)漏試驗(yan)使用接線方法見圖5。由于是交直(zhi)流(liu)(liu)(liu)(liu)兩用高(gao)壓(ya)(ya)(ya)(ya)試驗(yan)變壓(ya)(ya)(ya)(ya)器,應(ying)把高(gao)壓(ya)(ya)(ya)(ya)硅堆短路桿(gan)從套管(guan)中抽出,使試驗(yan)變壓(ya)(ya)(ya)(ya)器為直(zhi)流(liu)(liu)(liu)(liu)輸出狀(zhuang)態。做直(zhi)流(liu)(liu)(liu)(liu)泄(xie)(xie)漏試驗(yan)前,先(xian)根據泄(xie)(xie)漏試驗(yan)中輸出端斷路電(dian)(dian)流(liu)(liu)(liu)(liu)不超過高(gao)壓(ya)(ya)(ya)(ya)硅堆的(de)*大(da)整流(liu)(liu)(liu)(liu)為宜,選(xuan)擇好限流(liu)(liu)(liu)(liu)電(dian)(dian)阻(水電(dian)(dian)阻)的(de)阻值(zhi)(zhi),再根據被試品(pin)對(dui)直(zhi)流(liu)(liu)(liu)(liu)高(gao)壓(ya)(ya)(ya)(ya)波(bo)(bo)形(xing)的(de)要求選(xuan)擇好高(gao)壓(ya)(ya)(ya)(ya)濾波(bo)(bo)電(dian)(dian)容(rong)的(de)電(dian)(dian)容(rong)值(zhi)(zhi)。為了提高(gao)對(dui)被試品(pin)施(shi)加(jia)電(dian)(dian)壓(ya)(ya)(ya)(ya)的(de)測(ce)量精度,應(ying)在高(gao)壓(ya)(ya)(ya)(ya)側接入FRC阻容(rong)分壓(ya)(ya)(ya)(ya)器來測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)。
R- 限流電(dian)阻(zu); C- 高壓(ya)濾波電(dian)容; Zx- 被試品; G- 硅(gui)堆短(duan)路桿;
FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高壓整流硅堆。
按照圖5、結合圖3所進行的直流泄漏試驗接好工作線路。試驗變壓器的高壓繞組的X端(高壓尾)、儀表測量繞組的F 端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
接電(dian)(dian)源前、電(dian)(dian)源控制(zhi)箱(xiang)(臺)的(de)調(diao)壓器(qi)必須(xu)調(diao)到零(ling)位。接通電(dian)(dian)源后,綠色指(zhi)示燈亮,按一下(xia)啟動(dong)按鈕,紅色指(zhi)示燈亮,表示試驗變(bian)壓器(qi)已接通控制(zhi)電(dian)(dian)源,開始升壓。
從零(ling)位(wei)開(kai)始按順時針方向勻(yun)速(su)(su)(su)旋轉(zhuan)調(diao)壓(ya)(ya)器手輪升(sheng)(sheng)壓(ya)(ya)。(升(sheng)(sheng)壓(ya)(ya)方式有:快速(su)(su)(su)升(sheng)(sheng)壓(ya)(ya)法(fa)即20S逐(zhu)級升(sheng)(sheng)壓(ya)(ya)法(fa);慢速(su)(su)(su)升(sheng)(sheng)壓(ya)(ya)法(fa),即60S逐(zhu)級升(sheng)(sheng)壓(ya)(ya)法(fa);級慢速(su)(su)(su)升(sheng)(sheng)壓(ya)(ya)法(fa)供選(xuan)用)電(dian)(dian)壓(ya)(ya)從零(ling)開(kai)始按選(xuan)定(ding)的(de)升(sheng)(sheng)壓(ya)(ya)速(su)(su)(su)度(du)升(sheng)(sheng)到您所(suo)需額定(ding)試驗(yan)(yan)電(dian)(dian)壓(ya)(ya)或(huo)額定(ding)直流(liu)電(dian)(dian)流(liu)下的(de)參考電(dian)(dian)壓(ya)(ya)。試驗(yan)(yan)中應嚴密(mi)注(zhu)意直流(liu)高壓(ya)(ya)表(biao)、泄漏(lou)電(dian)(dian)流(liu)表(biao)指(zhi)示以及被(bei)試品的(de)情(qing)況。試驗(yan)(yan)完畢后,應訊速(su)(su)(su)均勻(yun)將高壓(ya)(ya)降至零(ling)位(wei),按一(yi)下停止按鈕(niu),高壓(ya)(ya)、低壓(ya)(ya)輸出(chu)停止,然(ran)后切斷電(dian)(dian)源。此(ci)時應用直流(liu)高壓(ya)(ya)放**給被(bei)試品及試驗(yan)(yan)裝置本(ben)身充(chong)分放電(dian)(dian)。
直(zhi)流泄漏試驗操作(zuo)過程注意(yi)事項
(1)試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
(2)被試品做試驗前,應拆除所有對外連線,并充分放電,主要部位應**干凈,保持**干燥,以免損壞被試品及帶來試驗數值的誤差。
(3)對于大容量試品(電容器、超長電纜等)試驗時應緩慢升壓,防止被試品的充電電流過大而燒壞微安表,必要時應分級加壓分別讀取各電壓下微安表的穩定讀數。
(4)試驗過程中,應嚴密監視被試品、微安表及試驗裝置等,一旦發生閃爍、擊穿等現象應立即降壓,切斷電源,并查明原因。
五、配套選購產品
下列產品僅供選擇,購買時需另行計價。
1.KZX系列電源控制箱 容量:1KVA-5KVA、輸入電壓:220V
2.KZT系列電源控制臺 容量:10KVA~300KVA輸入電壓:220V或380V
3.數字微安表:SWB-II
4.高壓濾波電容: 0.01MF、40 ~ 100KV
5.高壓直流放**: FBR— 70、140、210KV
6.放電球隙: Q—50、100、150、200、250、500
7.標準試油杯: 400ml
8.折疊式手推車: 150、300型
9.絕緣支架: 50、100、200、300、400KV
10.阻容分壓器: FRC —50、100、150、200KV
11.高壓硅堆: 2DL—150、300、450KV
12.水 電 阻: 50、100
六、主要試驗設備的選擇
1、試驗變壓器
其高壓側額定電壓應不小于被試品的*高試驗電壓,額定電流不小于被試品的*大電容電流。被試品的電容電流和試驗變壓器所需容量計算式為:
被試品電容(rong)量(liang)(liang)Cx可由交流電橋測出。常用的被試品電容(rong)量(liang)(liang)按(an)表(biao)1選(xuan)取。
幾種常用(yong)被試(shi)品的(de)電(dian)容量(pF) 表1
2、調(diao)壓設備
(1)自藕調壓器。其調壓范圍廣、功率損耗小、波形畸變小、選擇這種調壓方式為*好。自藕調壓器的容量按0.75 ~ 1倍的試驗變壓器的容量選擇,適用于容量為100KVA以下的試驗變壓器的調壓。
(2)感應調壓器。其調壓范圍大,波形畸形小、但結構復雜、價格較貴,當試驗變壓器的容量較大時(如100KVA以上)使用。
3、限流電阻
限流電阻的作用是,當被試品擊穿時,限制斷路電流,從而保護試驗變壓器,防止故障的擴大。其數值以*高試驗電壓為準,按0.5 ~ 1 Ω / V(有效值)選擇,限流電阻可用水電阻。注意水不能充滿玻璃管,應留有余地,以防爆裂。
4、放電球隙
放電球隙的布置方式有垂直和水平兩種,球隙間距S和球的直徑D的關系應保護在0.05D ≤S ≤0.5D范圍內,球隙上的水電阻阻值一般按0.1 ~ 1Ω/V選取,設置放電球隙的目的是為了對重要的被試品起保護作用,可以將由于誤操作或被試品擊穿引起的過電壓限制在允許的范圍內。
七、試驗變壓(ya)器(qi)技術指示(shi)
型號
|
容量
|
高壓電壓
|
高壓電流
|
低壓輸入
|
變比
|
溫升℃
|
(KVA)
|
(KV)
|
(mA)
|
電壓(V)
|
電流(A)
|
高/儀
|
30分(fen)鐘
|
YDQC-1.5/50
|
1.5
|
50
|
30
|
200
|
7.5
|
500
|
10
|
YDQC-3/50
|
3
|
50
|
60
|
200
|
15
|
500
|
10
|
YDQC-5/50
|
5
|
50
|
100
|
200
|
25
|
500
|
10
|
YDQC-10/50
|
10
|
50
|
200
|
200
|
50
|
500
|
10
|
YDQC-15/50
|
15
|
50
|
300
|
200
|
75
|
500
|
10
|
YDQC-20/50
|
20
|
50
|
400
|
380
|
53
|
500
|
10
|
YDQC-30/50
|
30
|
50
|
600
|
380
|
79
|
500
|
10
|
YDQC-50/50
|
50
|
50
|
1000
|
380
|
12
|
500
|
10
|
YDQC-5/100
|
5
|
100
|
50
|
200
|
25
|
1000
|
10
|
YDQC-10/100
|
10
|
100
|
100
|
200
|
50
|
1000
|
10
|
YDQC-20/100
|
20
|
100
|
200
|
400
|
50
|
1000
|
10
|
YDQC-30/100
|
30
|
100
|
300
|
400
|
75
|
1000
|
10
|
YDQC-50/100
|
50
|
100
|
500
|
400
|
125
|
1000
|
10
|
YDQC-20/150
|
20
|
150
|
133
|
400
|
50
|
1500
|
10
|
YDQC-30/150
|
30
|
150
|
200
|
400
|
75
|
1500
|
10
|
YDQC-50/150
|
50
|
150
|
333
|
400
|
125
|
1500
|
10
|
YDQC-100/150
|
100
|
150
|
667
|
400
|
250
|
1500
|
10
|
YDQC-50/200
|
50
|
200
|
250
|
400
|
125
|
2000
|
10
|
YDQC-100/200
|
100
|
200
|
500
|
400
|
250
|
2000
|
10
|
YDQC-150/200
|
150
|
200
|
750
|
400
|
375
|
2000
|
10
|
YDQC-200/200
|
200
|
200
|
1000
|
400
|
500
|
2000
|
10
|
YDQC-300/200
|
300
|
200
|
1500
|
400
|
600
|
2000
|
10
|
YDQC-50/300
|
50
|
300
|
170
|
400
|
125
|
3000
|
10
|
YDQC-100/300
|
100
|
300
|
333
|
400
|
250
|
3000
|
10
|
YDQC-150/300
|
150
|
300
|
500
|
400
|
375
|
3000
|
10
|
YDQC-200/300
|
200
|
300
|
667
|
400
|
500
|
3000
|
10
|
YDQC-300/300
|
300
|
300
|
3000
|
500
|
600
|
3000
|
10
|
1、使用環境條件
環境溫度不高于+40℃、不低于—20℃;空氣相對濕度不大于90%;海拔高度不超過2000米;
2、工作電壓
電源控制箱(臺)輸入電壓為工頻220V或380V、相對誤差不超過±10%;(具體使用電壓根據用戶所定試驗變壓器規格選取)
八、隨貨文件
YDQC 系列試驗變壓器產品說明書 1份
產品出廠試驗報告 1份
產品合格證 1份
裝箱單 1份
一、概述(shu)
YDQ系(xi)列高壓(ya)(ya)試(shi)(shi)驗變(bian)(bian)壓(ya)(ya)器(qi)是(shi)根據《試(shi)(shi)驗變(bian)(bian)壓(ya)(ya)器(qi)》標(biao)準,在(zai)油(you)(you)浸式試(shi)(shi)驗變(bian)(bian)壓(ya)(ya)器(qi)的(de)(de)(de)(de)基礎上而設計生產的(de)(de)(de)(de)。SF6氣(qi)(qi)體具(ju)(ju)有(you)良好的(de)(de)(de)(de)電(dian)(dian)氣(qi)(qi)絕(jue)(jue)緣(yuan)(yuan)性(xing)能(neng)及優異的(de)(de)(de)(de)滅弧(hu)性(xing)能(neng),其耐壓(ya)(ya)強度為(wei)同一(yi)壓(ya)(ya)力下(xia)氮氣(qi)(qi)的(de)(de)(de)(de)2.5倍,擊(ji)穿電(dian)(dian)壓(ya)(ya)的(de)(de)(de)(de)空氣(qi)(qi)的(de)(de)(de)(de)2.5倍。在(zai)0.25MPa下(xia)與(yu)油(you)(you)的(de)(de)(de)(de)擊(ji)穿電(dian)(dian)壓(ya)(ya)相等,在(zai)0.45MPa壓(ya)(ya)力下(xia)是(shi)油(you)(you)的(de)(de)(de)(de)擊(ji)穿電(dian)(dian)壓(ya)(ya)的(de)(de)(de)(de)2倍,是(shi)一(yi)種優于油(you)(you)的(de)(de)(de)(de)新一(yi)代超高壓(ya)(ya)絕(jue)(jue)緣(yuan)(yuan)介(jie)質材料(liao)。該(gai)產品技術要求完全符合(he)《ZBK-41006-89》標(biao)準,它是(shi)油(you)(you)浸式輕型試(shi)(shi)驗變(bian)(bian)壓(ya)(ya)器(qi)的(de)(de)(de)(de)換代產品。該(gai)產品具(ju)(ju)有(you)體積(ji)小、重量輕、不受氣(qi)(qi)候變(bian)(bian)化影響、電(dian)(dian)暈小、現場搬運無需靜止可使用,使用壽(shou)命(ming)長、免維修等特點(dian)。適用于電(dian)(dian)力系(xi)統、工礦企業、科研(yan)部門等對各種高壓(ya)(ya)電(dian)(dian)氣(qi)(qi)設備、電(dian)(dian)氣(qi)(qi)元件、絕(jue)(jue)緣(yuan)(yuan)材料(liao)進(jin)行工頻或(huo)直(zhi)流(liu)高壓(ya)(ya)下(xia)的(de)(de)(de)(de)絕(jue)(jue)緣(yuan)(yuan)強度試(shi)(shi)驗。
二、產品結構
YDQ系列高(gao)壓試驗變壓器(qi)采用單(dan)框(kuang)芯(xin)式鐵(tie)芯(xin)結構,初級(ji)繞(rao)組繞(rao)在鐵(tie)芯(xin)上(shang),高(gao)壓繞(rao)組在外,這種同軸布置減(jian)少了漏(lou)磁通(tong),因而增大了繞(rao)組間的耦合。產品的外殼為圓柱灌式容器(qi)結構,能耐受0.8MPa以上(shang)壓力。其結構見圖(tu)1:
三、工作原理(li)
YDQ系列高壓(ya)(ya)試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)器(qi)(qi)為單相變(bian)(bian)壓(ya)(ya)器(qi)(qi),聯結組(zu)(zu)標號Ⅰ.Ⅰ. 用工頻220V(10kVA以上為380V)電(dian)源接入 (為本公司生產的試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)器(qi)(qi)配套(tao)專用設備,詳(xiang)細(xi)資(zi)料(liao)請見其具體使用說明書)系列操(cao)作(zuo)箱(臺(tai)),經操(cao)作(zuo)箱內自偶(ou)調壓(ya)(ya)器(qi)(qi)(50kVA以上調壓(ya)(ya)器(qi)(qi)外(wai)附(fu))調節(jie)至(zhi)0~200V(或0~400V)電(dian)壓(ya)(ya)輸出至(zhi)YDQ試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)器(qi)(qi)的初(chu)級繞(rao)(rao)組(zu)(zu),根據電(dian)磁感(gan)應原(yuan)理,在試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)器(qi)(qi)高壓(ya)(ya)繞(rao)(rao)組(zu)(zu)可獲得(de)試(shi)驗(yan)所(suo)需的高電(dian)壓(ya)(ya)。
單(dan)臺(tai)YDQ系(xi)列交直(zhi)(zhi)流(liu)高(gao)(gao)壓(ya)(ya)(ya)試驗變壓(ya)(ya)(ya)器的工作原理圖見圖3,圖中(zhong)高(gao)(gao)壓(ya)(ya)(ya)套管中(zhong)裝(zhuang)有(you)高(gao)(gao)壓(ya)(ya)(ya)硅(gui)堆,串(chuan)接(jie)在高(gao)(gao)壓(ya)(ya)(ya)回路中(zhong)作半波整流(liu),以獲得直(zhi)(zhi)流(liu)高(gao)(gao)電(dian)壓(ya)(ya)(ya)。當用(yong)一短路桿將高(gao)(gao)壓(ya)(ya)(ya)硅(gui)堆短接(jie)時(shi),可獲得工頻高(gao)(gao)電(dian)壓(ya)(ya)(ya),作為(wei)交流(liu)輸出狀(zhuang)態;取(qu)消短路桿時(shi),作為(wei)直(zhi)(zhi)流(liu)輸出狀(zhuang)態。
圖中(zhong):D—短路桿(gan) VD—高(gao)壓硅堆
試驗變壓器高壓套(tao)管中的高壓硅堆(dui)未畫出(chu),其原理與上圖相(xiang)同(tong)。
三(san)臺(tai)(tai)(tai)(tai)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)串(chuan)級(ji)獲得更(geng)高(gao)(gao)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)的(de)(de)接(jie)線原理見(jian)圖4。串(chuan)級(ji)高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)有很大(da)的(de)(de)優越性(xing),因(yin)為(wei)整個試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)裝(zhuang)(zhuang)置由幾(ji)(ji)臺(tai)(tai)(tai)(tai)單(dan)(dan)(dan)臺(tai)(tai)(tai)(tai)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)組(zu)成(cheng)(cheng)(cheng),單(dan)(dan)(dan)臺(tai)(tai)(tai)(tai)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)容(rong)量(liang)(liang)小、電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)低(di)、重(zhong)量(liang)(liang)輕(qing),便于(yu)運輸(shu)和(he)安裝(zhuang)(zhuang)。它既然(ran)可串(chuan)接(jie)成(cheng)(cheng)(cheng)高(gao)(gao)出(chu)幾(ji)(ji)倍的(de)(de)單(dan)(dan)(dan)臺(tai)(tai)(tai)(tai)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)輸(shu)出(chu)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)組(zu)合使用(yong),又可分(fen)(fen)開成(cheng)(cheng)(cheng)幾(ji)(ji)套單(dan)(dan)(dan)臺(tai)(tai)(tai)(tai)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)單(dan)(dan)(dan)獨使用(yong)。整套裝(zhuang)(zhuang)置投(tou)資小,經濟(ji)實惠。圖5中,在(zai)(zai)第(di)(di)(di)**和(he)**級(ji)的(de)(de)每個單(dan)(dan)(dan)元試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)中都有一個勵磁繞(rao)組(zu)A1、C1和(he)A2、C2。在(zai)(zai)三(san)臺(tai)(tai)(tai)(tai)串(chuan)級(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)基本原理中,低(di)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)電(dian)(dian)源加在(zai)(zai)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)Ⅰ的(de)(de)初級(ji)繞(rao)組(zu)a1x1上(shang),單(dan)(dan)(dan)臺(tai)(tai)(tai)(tai)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)Ⅰ、Ⅱ、Ⅲ的(de)(de)輸(shu)出(chu)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)都是(shi)(shi)V。勵磁繞(rao)組(zu)A1、C1給(gei)**級(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)Ⅱ的(de)(de)初級(ji)繞(rao)組(zu)供電(dian)(dian);**級(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)Ⅱ的(de)(de)勵磁繞(rao)組(zu)A2、C2給(gei)第(di)(di)(di)三(san)級(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)Ⅲ的(de)(de)初級(ji)繞(rao)組(zu)供電(dian)(dian)。**級(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)Ⅱ和(he)第(di)(di)(di)三(san)級(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)Ⅲ的(de)(de)箱(xiang)(xiang)體分(fen)(fen)別處在(zai)(zai)對地(di)為(wei)1V和(he)2V的(de)(de)高(gao)(gao)電(dian)(dian)位(wei)上(shang),所以箱(xiang)(xiang)體對地(di)是(shi)(shi)絕(jue)緣的(de)(de),試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)Ⅰ的(de)(de)箱(xiang)(xiang)體是(shi)(shi)接(jie)地(di)的(de)(de)。這樣第(di)(di)(di)**、**級(ji)、第(di)(di)(di)三(san)級(ji)試(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)(qi)(qi)對地(di)的(de)(de)額(e)定(ding)(ding)輸(shu)出(chu)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)分(fen)(fen)別為(wei)1V、2V、3V;其(qi)額(e)定(ding)(ding)容(rong)量(liang)(liang)分(fen)(fen)別為(wei)3P、2P、1P。
YDQ系列(lie)高壓試驗變(bian)壓器做被試品的工(gong)頻耐壓試驗使用接線原理圖見圖5。
圖中:R1—限流(liu)電(dian)(dian)阻 FRC—阻容(rong)分壓(ya)器 RF—球間隙保護電(dian)(dian)阻 G—球間隙 CX—被試品
注:高壓尾(wei)必須可靠接(jie)地
工(gong)頻(pin)耐壓(ya)(ya)試驗中限(xian)流電阻(zu)(zu)(zu)R1應(ying)(ying)根據試驗變(bian)壓(ya)(ya)器(qi)的額(e)定容量(liang)(liang)來選擇(ze)。如高(gao)壓(ya)(ya)側額(e)定輸出(chu)電流在100~300mA時,可(ke)(ke)取0.5~1Ω/V(試驗電壓(ya)(ya));高(gao)壓(ya)(ya)側額(e)定輸出(chu)電流為1A以上時,可(ke)(ke)取1Ω/V(試驗電壓(ya)(ya))。常用水(shui)(shui)電阻(zu)(zu)(zu)作(zuo)為限(xian)流電阻(zu)(zu)(zu),管子(zi)長度(du)可(ke)(ke)按150kV/m考慮,管子(zi)粗(cu)細應(ying)(ying)具有足夠的熱容量(liang)(liang)(水(shui)(shui)阻(zu)(zu)(zu)液配制方法:用蒸餾(liu)水(shui)(shui)加入適量(liang)(liang)硫酸銅配制成各(ge)種(zhong)不同的阻(zu)(zu)(zu)值)。
球(qiu)間(jian)(jian)隙(xi)(xi)及保護(hu)電(dian)(dian)阻:當電(dian)(dian)壓(ya)超過球(qiu)間(jian)(jian)隙(xi)(xi)整定值時(shi)(一般(ban)取試驗電(dian)(dian)壓(ya)的110%~120%),球(qiu)間(jian)(jian)隙(xi)(xi)放電(dian)(dian),對被試品起到(dao)保護(hu)作用(yong)。球(qiu)間(jian)(jian)隙(xi)(xi)保護(hu)電(dian)(dian)阻可按1Ω/V(試驗電(dian)(dian)壓(ya))選取。
在工(gong)頻耐壓(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)中(zhong),低(di)電(dian)(dian)壓(ya)(ya)(ya)(ya)側(ce)測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)(儀(yi)表電(dian)(dian)壓(ya)(ya)(ya)(ya))不是(shi)(shi)非常準(zhun)確的(de),其原因是(shi)(shi)由于試(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)存在著(zhu)漏抗,在這個漏抗上(shang)(shang)必(bi)然(ran)存在著(zhu)壓(ya)(ya)(ya)(ya)降或容(rong)升(sheng),使試(shi)(shi)品(pin)上(shang)(shang)的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)低(di)于或高(gao)于低(di)壓(ya)(ya)(ya)(ya)側(ce)測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)表上(shang)(shang)反映(ying)出來(lai)的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)。工(gong)頻耐壓(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)時,被試(shi)(shi)品(pin)上(shang)(shang)的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)高(gao)于試(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)的(de)輸出電(dian)(dian)壓(ya)(ya)(ya)(ya),也(ye)就是(shi)(shi)所謂(wei)容(rong)升(sheng)現象。感(gan)應耐壓(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)時,試(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)的(de)漏抗必(bi)然(ran)存在著(zhu)壓(ya)(ya)(ya)(ya)降。為了準(zhun)確測(ce)量被試(shi)(shi)品(pin)上(shang)(shang)所施加的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya),因此常在高(gao)壓(ya)(ya)(ya)(ya)側(ce)接入FRC阻(zu)容(rong)分壓(ya)(ya)(ya)(ya)器(qi)(qi)來(lai)測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)(見圖5)。
工頻(pin)耐壓試驗操作注意事(shi)項
1)試(shi)驗人員應做好分工(gong),明確相互間聯系方法。并有專(zhuan)門人監護現場**及(ji)觀察試(shi)品狀態。
2)被(bei)試(shi)品應先清掃干凈(jing),并**干燥,以免損壞被(bei)試(shi)品和試(shi)驗(yan)帶來的誤差。
3)對于大型試(shi)驗(yan),一般都應先進(jin)行空升試(shi)驗(yan)。即不接試(shi)品(pin)時升壓(ya)至試(shi)驗(yan)電壓(ya),校(xiao)對各種表(biao)計,調整球間隙。
4)升壓(ya)速度不(bu)能太快,并必須防止突然加壓(ya)。例(li)如調壓(ya)器不(bu)在(zai)零位時突然合(he)閘。也不(bu)能突然切(qie)斷電源(yuan),一般應在(zai)調壓(ya)器降至(zhi)零位時拉閘。
5)當電壓(ya)升至試(shi)驗電壓(ya)時(shi)(shi)(shi),開(kai)始計時(shi)(shi)(shi),到1min后,迅速降(jiang)壓(ya)到1/3試(shi)驗電壓(ya)以下時(shi)(shi)(shi),才(cai)能(neng)拉開(kai)電源(yuan)。
6)在升(sheng)壓(ya)(ya)(ya)(ya)或(huo)耐(nai)壓(ya)(ya)(ya)(ya)試(shi)驗過程中,如發現下(xia)列(lie)不正常情況時,應立即降壓(ya)(ya)(ya)(ya),切斷電源。停(ting)止試(shi)驗并查(cha)明(ming)原因:①電壓(ya)(ya)(ya)(ya)表指針擺動很大;②發現絕緣燒焦(jiao)或(huo)冒煙;③被試(shi)品內有不正常的聲音。
7)耐壓試驗前(qian)后應測量(liang)絕(jue)緣(yuan)電阻,檢查絕(jue)緣(yuan)情況。
試驗(yan)(yan)變壓器在做(zuo)被試品的(de)直(zhi)流耐壓或(huo)泄露試驗(yan)(yan)時(shi)接(jie)線原理圖(tu)如圖(tu)6。
注:此(ci)試驗應先抽出短路(lu)桿“D”,圖(tu)6中所示。
圖中:VD—高(gao)壓硅堆 R1—限流電阻 C1—高(gao)壓濾波(bo)電容(rong) FRC—阻容(rong)分壓器 CX—被試品 μA—帶保護微安表
泄(xie)露試(shi)驗(yan)中限(xian)流(liu)(liu)電(dian)(dian)阻R1選擇在(zai)額定輸出電(dian)(dian)壓(ya)時,輸出端(duan)短路電(dian)(dian)流(liu)(liu)不超過高壓(ya)硅(gui)(gui)堆(dui)的(de)(de)*大(da)整(zheng)(zheng)流(liu)(liu)。如電(dian)(dian)壓(ya)硅(gui)(gui)堆(dui)的(de)(de)*大(da)整(zheng)(zheng)流(liu)(liu)電(dian)(dian)流(liu)(liu)為100mA時用于(yu)60kV的(de)(de)試(shi)驗(yan)裝置中,限(xian)流(liu)(liu)電(dian)(dian)阻按(an)R1=60/0.1=600kΩ選擇。限(xian)流(liu)(liu)電(dian)(dian)阻還應具有足(zu)夠的(de)(de)容量和沿(yan)面放電(dian)(dian)距離(li)。
高壓濾(lv)波電(dian)容(rong)C1一般選擇在0.01~0.1μF,當被試品的電(dian)容(rong)量很(hen)大時,C1可省(sheng)略不用(yong)。
泄(xie)露(lu)試驗的操作及注意(yi)事項
1)試(shi)驗(yan)前(qian)應先檢查被試(shi)品(pin)是(shi)否停電,接地放電,一切對外連(lian)線是(shi)否擦干(gan)凈。要嚴防將試(shi)驗(yan)電壓加到有人工(gong)作的部位上去。
2)接好(hao)試驗(yan)裝置的接線后,應復查無誤后才可(ke)加壓。應特別(bie)注意檢查高(gao)壓設備及引(yin)線與地、與操作人(ren)員的**距離(li),被試品的外殼是否可(ke)靠接地,要按**規(gui)(gui)程(cheng)中所規(gui)(gui)定(ding)的內(nei)容(rong)進行試驗(yan)。
3)對于(yu)大電(dian)容量設(she)備應緩慢(man)升壓,防止被試品的(de)充電(dian)電(dian)流燒(shao)壞微安(an)表(biao)。必要時應分級加壓,分別讀取各級電(dian)壓下微安(an)表(biao)的(de)穩(wen)定(ding)讀數。
4)試(shi)驗過(guo)程中(zhong),應(ying)密切監視被試(shi)品、試(shi)驗裝置、微安表(biao),一旦發生擊穿、閃爍等(deng)異常現象應(ying)立即降壓,切斷電源,并查明原因,詳細記(ji)錄。
5)試(shi)驗完畢,降壓(ya),切斷電源后應將(jiang)被試(shi)品及試(shi)驗裝置本身充分放(fang)電。
四(si)、注(zhu)意(yi)事項(xiang)
1、按(an)照您所進行的(de)(de)試(shi)驗(yan)接(jie)好(hao)工作線路。試(shi)驗(yan)變(bian)壓器的(de)(de)外殼以及操作系統的(de)(de)外殼必須(xu)可(ke)靠(kao)接(jie)地(di)。試(shi)驗(yan)變(bian)壓器高壓繞組(zu)的(de)(de)X端(duan)(高壓尾)以及測量繞組(zu)的(de)(de)F端(duan)必須(xu)可(ke)靠(kao)接(jie)地(di)。
2、做串級(ji)試(shi)驗(yan)時,**級(ji)、第三(san)級(ji)試(shi)驗(yan)變(bian)壓(ya)器(qi)(qi)的低壓(ya)繞組(zu)的X端(duan),測量繞組(zu)的F端(duan)以及高壓(ya)繞組(zu)的X端(duan)(高壓(ya)尾)均接本級(ji)試(shi)驗(yan)變(bian)壓(ya)器(qi)(qi)的外殼。**級(ji)、第三(san)級(ji)試(shi)驗(yan)變(bian)壓(ya)器(qi)(qi)的外殼必須(xu)通過絕緣支架接地(di)。
3、接(jie)通電(dian)源前,操作系統的調壓器必須調到零位后方可(ke)接(jie)通電(dian)源,合閘,開始升壓。
4、從零(ling)開始(shi)均(jun)勻旋轉(zhuan)調壓(ya)(ya)(ya)器(qi)手輪升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)。升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)方(fang)法(fa)(fa)(fa)有:快速升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa)(fa)(fa),即(ji)(ji)20s逐級升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa)(fa)(fa);慢速升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa)(fa)(fa),即(ji)(ji)60s逐級升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa)(fa)(fa);極慢速升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa)(fa)(fa)供選用。電(dian)(dian)壓(ya)(ya)(ya)從零(ling)開始(shi)按一定(ding)的(de)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)方(fang)式和速度上升(sheng)(sheng)(sheng)到您所需的(de)額(e)定(ding)試驗(yan)電(dian)(dian)壓(ya)(ya)(ya)的(de)75%后,在以(yi)每秒2%額(e)定(ding)試驗(yan)電(dian)(dian)壓(ya)(ya)(ya)的(de)速度升(sheng)(sheng)(sheng)到您所需的(de)額(e)定(ding)電(dian)(dian)壓(ya)(ya)(ya),并密切注意測(ce)量儀表的(de)指(zhi)示(shi)以(yi)及被(bei)試品的(de)情(qing)(qing)(qing)況。升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)過(guo)程(cheng)中或試驗(yan)過(guo)程(cheng)中如發(fa)現測(ce)量儀表的(de)指(zhi)示(shi)及被(bei)試品情(qing)(qing)(qing)況異常,應立即(ji)(ji)降壓(ya)(ya)(ya),切斷電(dian)(dian)源(yuan),查明(ming)情(qing)(qing)(qing)況。
5、試(shi)驗完畢后,應在數秒內勻速的將調壓器返回至零(ling)位(wei),然后切斷電源。
6、本產(chan)品不(bu)得(de)超過額定參數使用(yong)。除試驗必須外,決不(bu)允許全(quan)電壓通電或斷電。
7、 再升壓(ya)或耐壓(ya)試(shi)驗過程(cheng)中,如發現以下不正常情況時,應立即降壓(ya),切斷電源,停止試(shi)驗并查明原因(yin)。
⑴電(dian)壓表指針擺(bai)動(dong)(或數字(zi)跳動(dong))很(hen)大
⑵電流表直線上(shang)升
被試(shi)品(pin)內有(you)不正常的聲音
8、圖1中第9項(xiang)系(xi)壓力閥及壓力表(biao),為長期關(guan)閉(bi)狀態。每6個月開(kai)閥一次,以檢(jian)查SF6壓力,應不(bu)小于0.2MPa(檢(jian)查壓力后立即關(guan)閉(bi)閥門),低于0.2MPa時應加SF6氣(qi)體,以增(zeng)加氣(qi)絕緣。
9、耐壓(ya)實驗前后應測量被試設備的絕緣(yuan)電(dian)阻,檢查絕緣(yuan)情況。
10、當(dang)試驗變(bian)壓器長(chang)期(qi)不使用時,應放(fang)置于通風、干燥、無(wu)陽(yang)光直射的地方。
11、該產品(pin)不允許(xu)在高于45℃的(de)溫度下長期存(cun)放、使用、放氣(qi)。
12、運(yun)輸搬運(yun)途中不(bu)得(de)重力沖擊。
13、產品(pin)緊固件及壓(ya)力(li)(li)閥、壓(ya)力(li)(li)表不得(de)擅自松動。
14、使用本產品做高壓試(shi)驗(yan)(yan)時,出熟(shu)悉本說明(ming)書外,還必須嚴格(ge)執(zhi)行國(guo)家有(you)關標準和操作(zuo)規(gui)程(cheng)。可(ke)參照GB311-83《高壓輸變設(she)備的絕緣配(pei)合,高壓試(shi)驗(yan)(yan)技術》;《電氣設(she)備預(yu)防性試(shi)驗(yan)(yan)規(gui)程(cheng)》等。
五、試驗變壓器的容量(liang)選擇
標稱試驗變(bian)壓器容量Pn的(de)確定公式:Pn=kVn 2ωCt×10-9
式(shi)中:
Pn——標(biao)稱(cheng)試驗變壓器容量(kVA)
Vn——試驗變壓器(qi)的額定輸出高壓的有效值(kV)
k ——**系數。k≥1,標稱電(dian)壓Vn≥1MV時(shi),k=2;標稱電(dian)壓較低時(shi),k值可取高一些(xie)。
Ct——被試品的電容量(pF)
ω——角頻(pin)率,ω=2πf,f——試驗電源(yuan)的(de)頻(pin)率
被試設備(bei)的電(dian)容量(liang)Ct可由交流電(dian)橋測出。Ct的變化很大,
可由設(she)備的類型而定。
典型數(shu)據如下:
簡單的棒式或懸(xuan)式絕緣(yuan)子 幾(ji)十(shi)微法
簡單的(de)分級套(tao)管 100~1000pF
電壓互感器 200 ~ 500pF
電力變(bian)壓器 < 1000kVA~1000pF
> 1000kVA 1000~10000pF
高壓電力電纜(lan)和油浸(jin)紙絕緣 250~300pF/m
氣體絕緣 ~60pF/m
封閉變電站(zhan),SF6氣體(ti)絕(jue)緣 100~10000Pf;
對于不同(tong)的(de)試(shi)驗電壓Vn,選(xuan)擇不同(tong)的(de)(適當(dang)的(de))**系數k。
以下列(lie)出不(bu)同的Vn所選用(yong)的k值供參考。
Vn =50~100kV k = 4
Vn =150~300kV k = 3
Vn > 300kV k = 2
一、概(gai)述
工頻耐(nai)壓試(shi)驗是鑒定(ding)電(dian)力(li)設備(bei)絕(jue)緣強度(du)的(de)*嚴格、*有(you)效(xiao)和(he)*直(zhi)接(jie)的(de)方法。它能檢查出(chu)那些危險性較大的(de)集(ji)中(zhong)缺陷,對判斷電(dian)力(li)設備(bei)能否(fou)繼續參加運行具有(you)決定(ding)性作用,是保證設備(bei)絕(jue)緣水平、避免發生絕(jue)緣事故的(de)重要(yao)手段。
本(ben)裝(zhuang)置是根據國(guo)家*新(xin)電(dian)(dian)力(li)(li)行業標準而設(she)計的(de)、性能先進(jin)的(de)耐壓(ya)(ya)試驗設(she)備,用于(yu)對(dui)各種電(dian)(dian)器產品(pin)、電(dian)(dian)氣(qi)元件(jian)、絕(jue)緣(yuan)材料等進(jin)行規定電(dian)(dian)壓(ya)(ya)下的(de)絕(jue)緣(yuan)強度試驗,以考核產品(pin)的(de)絕(jue)緣(yuan)水平,發現被試品(pin)的(de)絕(jue)緣(yuan)缺(que)陷,衡(heng)量過電(dian)(dian)壓(ya)(ya)的(de)能力(li)(li)。
二、產(chan)品特點
監(jian)視功能:高(gao)壓電壓 低壓電流 零位指示(shi) 電源(yuan)指示(shi) 工作指示(shi) 計時指示(shi)
保(bao)護(hu)功能:過流保(bao)護(hu)、零位(wei)啟動保(bao)護(hu)、聲(sheng)光(guang)語(yu)言報(bao)警(jing)提醒(xing)
采用新(xin)型時間(jian)繼電器,計時范圍更廣(1S~99H)
采(cai)用新型電流繼(ji)電器,更(geng)**、更(geng)可靠,確(que)保人身及設備**。
試驗變壓(ya)器高壓(ya)線圈為圓(yuan)筒多層塔式,由上等(deng)聚酯漆包線及高耐(nai)壓(ya)值絕(jue)緣(yuan)材料繞制而成。
試驗變(bian)壓器(5kVA以上(shang))裝有(you)可移動的鐵輪。具(ju)有(you)重量輕(qing)、體積小、移動方便、性(xing)能優(you)越(yue)等(deng)特點。
三(san)、設備組成
1、選型配(pei)置(zhi)
標(biao)準配置
|
□ 分(fen)體式
|
操(cao)作(zuo)部分:
□箱式(不大于5kVA) / □臺式
容(rong)量: kVA(小于200kVA)
輸入:□AC220V / □AC380V
|
試驗變壓器:
□交(jiao)流 / □交(jiao)直流
□油變(bian) / □干變(bian) / □氣變(bian)
容量: kVA(小于200kVA)
輸出(chu):AC kV(小于300kVA)
|
□ 一體式
|
□箱(xiang)式(shi)(不(bu)大于20kV) / □臺式(shi)(不(bu)大于30kV)
容量: kVA(小(xiao)于300kVA)
輸入:□AC220V / □AC380V 輸出:AC kV(不大于30kV)
|
客戶選配
|
□標準高壓分壓器
|
□保護球隙
|
□直流微安表
|
□放**
|
□保護水阻
|
□高壓濾波電容(rong)
|
其它:
|
2、對應實物(wu)
四(si)、技術指標(biao)
1、使(shi)用(yong)條(tiao)件:
(1)工作場所應無嚴重影響(xiang)絕(jue)緣的氣體、蒸汽、化學(xue)性塵埃及其它爆炸(zha)性和腐蝕性介(jie)質。
(2)環境溫(wen)度 -20~+50℃
(3)環(huan)境濕度 ≤85% RH(無凝結水(shui))
2、控制箱(臺)參(can)數(shu)(shu):(常規參(can)數(shu)(shu)見下表)
規(gui)格(ge)
|
容量
|
輸 入(ru) 電 源
|
輸 出 電 壓
|
重量(liang)(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說明:如有特殊參數要(yao)求,可按用戶的技術參數進(jin)行(xing)設計制作。
3、試(shi)驗變壓器參數:(常(chang)規參數見下表)
規格
|
容(rong)量
kVA
|
低壓(ya)側
|
高(gao)壓側
|
高壓(ya)側(交直(zhi)流變(bian)壓(ya)器)
|
測量(liang)變比
|
60分鐘溫升℃
|
阻抗電(dian)壓%
|
空載電流
%
|
質量
kg
|
電壓(ya)
V
|
電流
A
|
交流輸出
|
直流輸出
|
電壓kV
|
電流
|
電壓kV
|
電(dian)流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如(ru)有特殊參數要(yao)求,可按用戶的技術參數進行(xing)設(she)計制作。
上表(biao)的重量以油浸式(shi)試(shi)驗(yan)變壓(ya)器(qi)(qi)為例,干式(shi)試(shi)驗(yan)變壓(ya)器(qi)(qi)和充氣式(shi)試(shi)驗(yan)變壓(ya)器(qi)(qi)稍有不同。
五、接線及(ji)工作原理
1、調壓部分接線及原理
調壓(ya)部(bu)分由控(kong)制部(bu)分和(he)試驗變壓(ya)器組(zu)成(cheng)。控(kong)制部(bu)分是由接觸式調壓(ya)器及其控(kong)制、保護(hu)、測量(liang)、信號電(dian)路(lu)組(zu)成(cheng)。試驗變壓(ya)器由低壓(ya)繞(rao)組(zu)、高壓(ya)繞(rao)組(zu)、儀表(biao)繞(rao)組(zu)三部(bu)分組(zu)成(cheng)。
試驗變(bian)(bian)(bian)(bian)壓器為(wei)交(jiao)直流(liu)兩用時,試驗變(bian)(bian)(bian)(bian)壓器配置了高壓硅堆(dui)(油變(bian)(bian)(bian)(bian)、氣(qi)變(bian)(bian)(bian)(bian)為(wei)內置,干變(bian)(bian)(bian)(bian)為(wei)外置),高壓可輸出交(jiao)流(liu)和直流(liu)。輸出交(jiao)流(liu)時,要求接(jie)入短(duan)(duan)路桿(油變(bian)(bian)(bian)(bian)、氣(qi)變(bian)(bian)(bian)(bian))或去掉外置硅堆(dui)(干變(bian)(bian)(bian)(bian));輸出直流(liu)時,要求擰(ning)出短(duan)(duan)路桿(油變(bian)(bian)(bian)(bian)、氣(qi)變(bian)(bian)(bian)(bian))或加上外置硅堆(dui)(干變(bian)(bian)(bian)(bian))
通過(guo)接入工(gong)頻電(dian)源,調(diao)節調(diao)壓器,以獲(huo)得(de)所需要的試(shi)驗高(gao)壓電(dian)壓值。其工(gong)作原(yuan)理見(jian)圖1:
2、試驗部(bu)分接線及原理
做耐壓(ya)試驗時,控制部分、變壓(ya)器的(de)接地端及(ji)高(gao)壓(ya)尾必須可靠接地。有條件的(de)情況下,做工頻耐壓(ya)試驗請加(jia)上限流電(dian)(dian)阻(zu)、標準高(gao)壓(ya)分壓(ya)器、球(qiu)隙(xi)(xi)保護電(dian)(dian)阻(zu)及(ji)保護球(qiu)隙(xi)(xi),如圖3。
做直(zhi)(zhi)流耐壓(ya)試驗請(qing)另外(wai)加上(shang)微安(an)(an)表(biao),微安(an)(an)表(biao)必須(xu)接(jie)在硅(gui)堆(dui)和被試器(qi)之間(jian),油變(bian)(bian)或氣變(bian)(bian)一般(ban)擰(ning)在高壓(ya)頭(tou)上(shang)面(mian)(mian)(要求擰(ning)出短路(lu)桿),干變(bian)(bian)擰(ning)在外(wai)置硅(gui)堆(dui)上(shang)面(mian)(mian);為了更準確顯示高壓(ya)直(zhi)(zhi)流泄(xie)漏電流,請(qing)將(jiang)分壓(ya)器(qi)的高壓(ya)線接(jie)在微安(an)(an)表(biao)和硅(gui)堆(dui)之間(jian),(油變(bian)(bian)、氣變(bian)(bian))如圖(tu)4,(干變(bian)(bian))如圖(tu)5。
耐壓(ya)(ya)(ya)試(shi)驗中限流(liu)電阻R1應根據(ju)試(shi)驗變壓(ya)(ya)(ya)器的(de)額定容量來選擇。如高(gao)壓(ya)(ya)(ya)側額定輸出電流(liu)在100~300mA時(shi),可取0.5~1Ω/V(試(shi)驗電壓(ya)(ya)(ya));高(gao)壓(ya)(ya)(ya)側額定輸出電流(liu)為1A以上時(shi),可取1Ω/V(試(shi)驗電壓(ya)(ya)(ya))。常用水(shui)(shui)電阻作為限流(liu)電阻,管子(zi)長度可按150kV/m考慮,管子(zi)粗(cu)細(xi)應具有足夠的(de)熱容量(水(shui)(shui)阻液配制方法(fa):用蒸(zheng)餾水(shui)(shui)加入適量硫酸銅配制成(cheng)各種不同的(de)阻值)。
球間隙(xi)(xi)及保(bao)護電阻:當電壓超過(guo)球間隙(xi)(xi)整(zheng)定(ding)值時(一般取試驗電壓的(de)110%~120%),球間隙(xi)(xi)放電,對被試品起到保(bao)護作用(yong)。球間隙(xi)(xi)保(bao)護電阻可按1Ω/V(試驗電壓)選(xuan)取。
在(zai)(zai)工頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)中,低電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)測量(liang)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(儀表電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya))不是(shi)(shi)(shi)非(fei)常(chang)準確的(de)(de),其原因是(shi)(shi)(shi)由于(yu)試(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器存在(zai)(zai)著(zhu)(zhu)漏(lou)抗(kang),在(zai)(zai)這個漏(lou)抗(kang)上必(bi)然存在(zai)(zai)著(zhu)(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)降或(huo)容升,使試(shi)品上的(de)(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)低于(yu)或(huo)高于(yu)低壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)測量(liang)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)表上反(fan)映出(chu)來(lai)的(de)(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)。工頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)時(shi),被試(shi)品上的(de)(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)高于(yu)試(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器的(de)(de)輸出(chu)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya),也就是(shi)(shi)(shi)所(suo)謂(wei)容升現象。感應耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)時(shi),試(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器的(de)(de)漏(lou)抗(kang)必(bi)然存在(zai)(zai)著(zhu)(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)降。為(wei)了準確測量(liang)被試(shi)品上所(suo)施加的(de)(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya),因此常(chang)在(zai)(zai)高壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)接入標(biao)準高壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)分壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器來(lai)測量(liang)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)。
五、面板(ban)結構說明
1、操作箱面(mian)板
控(kong)制箱(xiang)(xiang)為(wei)箱(xiang)(xiang)式鋁合金結(jie)構,面板(ban)采用拉絲鋁合金工藝,所有電器元(yuan)件(jian)均(jun)裝(zhuang)在骨架(jia)上,便于(yu)安裝(zhuang)和維修。面板(ban)元(yuan)件(jian)布(bu)置如下:
2、操作臺面板
操作臺為(wei)臺式結構(gou),殼體為(wei)冷扎鋼板結構(gou),面板采用鋁合金拉絲工藝(yi),面板元件(jian)布置如下(xia):
六、操(cao)作指南
本(ben)(ben)裝置在操作(zuo)之前應根據(ju)不同被試(shi)品的容(rong)量、電(dian)壓(ya)等級,先計算(suan)好*大工作(zuo)電(dian)流(liu),并調(diao)整(zheng)電(dian)流(liu)保護器。其試(shi)驗接(jie)線應參考本(ben)(ben)說(shuo)明(ming)書中圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5,必(bi)須可靠接(jie)地。
1、操(cao)作(zuo)要點
(1)試(shi)(shi)驗(yan)(yan)前,應(ying)了(le)解(jie)被試(shi)(shi)品的(de)試(shi)(shi)驗(yan)(yan)電(dian)壓,同時了(le)解(jie)被試(shi)(shi)品的(de)其(qi)他試(shi)(shi)驗(yan)(yan)項目及以前的(de)試(shi)(shi)驗(yan)(yan)結果。若被試(shi)(shi)品有缺陷(xian)或異常,應(ying)在(zai)消除后(hou)再進行耐壓試(shi)(shi)驗(yan)(yan)。
(2)試驗現場應(ying)圍好(hao)遮攔或圍繩,掛好(hao)標示牌,并派專人監(jian)護(hu)。
(3)試(shi)(shi)驗前,被試(shi)(shi)品(pin)表面應(ying)(ying)擦拭干凈,將被試(shi)(shi)品(pin)的(de)外殼和非被試(shi)(shi)繞組(zu)可靠接地(di)。被試(shi)(shi)品(pin)為新(xin)沖(chong)油設備(bei)時(shi)(shi),應(ying)(ying)按(an)《規(gui)程》規(gui)定使油靜(jing)止(zhi)一(yi)定時(shi)(shi)間再升(sheng)壓(ya),對110kV及(ji)以下的(de)充油電力設備(bei),在注(zhu)滿油后靜(jing)置時(shi)(shi)間應(ying)(ying)不少(shao)于24小(xiao)時(shi)(shi),對220kV及(ji)330kV的(de)充油電力設備(bei),靜(jing)置時(shi)(shi)間應(ying)(ying)不少(shao)于48小(xiao)時(shi)(shi)。
(4)接好試驗(yan)接線后,應由有(you)經(jing)驗(yan)的人員檢查(cha),確認無(wu)誤后方可(ke)升壓(ya)。
(5)升(sheng)壓前,首先檢查調壓器(qi)是否在(zai)零(ling)位。調壓器(qi)在(zai)零(ling)位方可升(sheng)壓。
(6)升壓(ya)過程中不(bu)僅要監視電(dian)(dian)壓(ya)表的(de)變化(hua),還(huan)應監視電(dian)(dian)流(liu)表的(de)變化(hua),以及被試品電(dian)(dian)流(liu)的(de)變化(hua)。升壓(ya)時(shi)要均(jun)勻升壓(ya),不(bu)能太快(kuai)。升至(zhi)規定試驗電(dian)(dian)壓(ya)時(shi),開(kai)始計算(suan)時(shi)間,時(shi)間到(dao)后,緩慢均(jun)勻降下電(dian)(dian)壓(ya)。絕不(bu)允許不(bu)降壓(ya)就先跳開(kai)電(dian)(dian)源開(kai)關。
(7)試驗中(zhong)發現表針擺動或(huo)被試品有異常聲響、冒煙等應(ying)立即降下電壓(ya),拉(la)開電源(yuan),在(zai)高壓(ya)側掛上接地線(xian)后,再查明原因。
(8)耐壓試驗前后均應測量被試品的絕緣電阻。
2、操(cao)作步驟
(1) 按試驗要求(qiu)將控制部分、試驗變(bian)壓器、被(bei)試品正確接好(hao)線,必須可(ke)靠(kao)接地(di),請參考圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5。
(2) 根據試(shi)驗的要求,整定“時(shi)間繼(ji)電(dian)器”及“過流繼(ji)電(dian)器”。
A 時間繼電(dian)器設置:
T1,T2,T3,T4設置(zhi)(zhi)0~9任意數字,T可設置(zhi)(zhi)為H(小時(shi)),M(分鐘),S(秒)。
根(gen)據(ju)試(shi)驗要求,在1S~99H內可(ke)以任(ren)意(yi)設置定時時間。
B 過流(liu)繼電器(qi)設(she)置:
過(guo)流(liu)動作設(she)定(ding)值=過(guo)流(liu)繼電(dian)器(qi)(qi)刻(ke)度盤(pan)讀數×測(ce)量變比×K,其中K為電(dian)流(liu)倍率(lv)/切(qie)除開(kai)(kai)關的(de)(de)狀態值,分別為X1,X2,OFF,電(dian)流(liu)倍率(lv)/切(qie)除開(kai)(kai)關處于×1,×2位置時,K值分別為1、2,切(qie)換為OFF擋(dang)時,K值為+∞。(注:不要使用OFF檔,因為會(hui)使變壓器(qi)(qi)失(shi)去(qu)過(guo)流(liu)保護(hu)功(gong)能(neng)而(er)導致設(she)備(bei)損壞。測(ce)量變比為電(dian)流(liu)互(hu)感(gan)器(qi)(qi)的(de)(de)變比,沒有(you)電(dian)流(liu)互(hu)感(gan)器(qi)(qi)時為1)。
(3) 接入(ru)電源,此(ci)時(shi),“電源燈(deng)(deng)”亮(liang)(liang),表(biao)示外部電源已引(yin)入(ru)。如“零(ling)位(wei)燈(deng)(deng)”亮(liang)(liang),表(biao)示調(diao)(diao)壓(ya)器(qi)在零(ling)位(wei)。如“零(ling)位(wei)燈(deng)(deng)”不亮(liang)(liang),應(ying)逆時(shi)針旋轉調(diao)(diao)節(jie)調(diao)(diao)壓(ya)器(qi)手柄至(zhi)“零(ling)位(wei)燈(deng)(deng)”亮(liang)(liang),表(biao)示可進行調(diao)(diao)壓(ya)操作(zuo)。
(4)按“啟動按鈕”。此時,“送電(dian)燈”,“電(dian)源燈”和(he)“零位(wei)燈”亮;進(jin)入送電(dian)狀態(tai)。
(5)以2kV/S勻速順(shun)時(shi)針旋轉(zhuan)調壓(ya)(ya)器手柄至被試品規定的耐壓(ya)(ya)值(zhi),并密切注(zhu)視(shi)電流(liu)表(直(zhi)流(liu)耐壓(ya)(ya)試驗(yan)時(shi),同時(shi)密切注(zhu)視(shi)直(zhi)流(liu)微安表)。此時(shi),“電源燈(deng)”,“工(gong)作燈(deng)”亮(liang);“零(ling)位燈(deng)”滅(mie)。
(6)根據(ju)試驗啟動(dong)“計時(shi)按鈕”,計時(shi)開始,并注意(yi)被試品的情況。
(7)當耐壓計時(shi)到時(shi),操作臺自(zi)動聲光報(bao)警。應立即(ji)逆時(shi)針旋轉調壓器手柄至(zhi)零位,按下停止按鈕和解除計時(shi)按鈕自(zi)鎖狀(zhuang)態。此(ci)時(shi)“電源燈”, “零位燈”亮(liang),“工作燈”滅。試(shi)驗即(ji)告(gao)完(wan)畢
(8)拔(ba)掉電源,拆除接(jie)線,試驗結束。
(9)在升(sheng)壓或耐壓過程中,如發生短路、閃絡、擊穿過流時,過流繼電器動作(zuo),切斷主回路。此時應將調壓器逆時針旋轉至零位,切斷電源,并查明原因,并作(zuo)詳細記錄。
(10)試驗完畢(bi),降壓,切斷電源后應用放**將被試品及試驗裝置本身充分放電。
七(qi)、產品維護(hu)
1、開箱驗收時,應檢查(cha)主控回路接線是否(fou)松動(dong),調(diao)壓(ya)器(qi)電(dian)刷是否(fou)接觸良好(hao);
2、長(chang)期不用(yong)(yong)時,使用(yong)(yong)前(qian)應用(yong)(yong)500V兆歐表測(ce)量(liang)絕緣電(dian)阻(zu),其阻(zu)值(zhi)不低(di)于0.5MΩ;
3、電源電壓(ya)應符合控制箱(臺)銘牌上的輸入電壓(ya)值;
4、本(ben)裝置(zhi)設有過電流保(bao)護,出廠已調整(zheng)為額定電流的(de)50%。用于小負載(zai)時,應根據被試品的(de)額定容量電流重(zhong)新設定;
5、使用完畢(bi)后,應關(guan)好控制箱(臺)門,以(yi)保(bao)持控制箱(臺)內部清(qing)潔。
八、注意事項
1、按(an)照您所(suo)進行的試驗(yan)(yan)接(jie)好工作線路。試驗(yan)(yan)變壓器的外殼以(yi)及操作系統的外殼必(bi)須可靠(kao)接(jie)地。試驗(yan)(yan)變壓器的高(gao)壓繞組(zu)的X端(duan)(高(gao)壓尾)以(yi)及測量繞組(zu)的F端(duan)必(bi)須可靠(kao)接(jie)地。
2、做串級(ji)(ji)試驗(yan)時,**級(ji)(ji)、第(di)三(san)(san)級(ji)(ji)試驗(yan)變壓器的(de)低壓繞組(zu)成(cheng)X端,測量繞組(zu)的(de)F端以及(ji)高(gao)壓繞組(zu)的(de)X端(高(gao)壓端)均接(jie)(jie)本級(ji)(ji)試驗(yan)變壓器具(ju)外(wai)殼(ke)。**級(ji)(ji)、第(di)三(san)(san)級(ji)(ji)試驗(yan)變壓器的(de)外(wai)殼(ke)必須通(tong)過絕緣(yuan)支架接(jie)(jie)地。
3、接(jie)通(tong)電源前,操作系統(tong)的(de)調壓(ya)(ya)器必(bi)須調到(dao)零位后方可接(jie)通(tong)電源,合(he)閘(zha),開(kai)始升(sheng)(sheng)壓(ya)(ya)。從(cong)零開(kai)始勻速旋轉調壓(ya)(ya)器手輪(lun)升(sheng)(sheng)壓(ya)(ya)。升(sheng)(sheng)壓(ya)(ya)方式(shi)有(you):快(kuai)速升(sheng)(sheng)壓(ya)(ya)法,即(ji)20s逐(zhu)級升(sheng)(sheng)壓(ya)(ya)法;慢速升(sheng)(sheng)壓(ya)(ya)法,即(ji)60s逐(zhu)級升(sheng)(sheng)壓(ya)(ya)法;極慢速升(sheng)(sheng)壓(ya)(ya)法供(gong)選用。電壓(ya)(ya)從(cong)零開(kai)始按一定的(de)升(sheng)(sheng)壓(ya)(ya)方式(shi)和速度(du)上升(sheng)(sheng)到(dao)您(nin)所需的(de)額定試(shi)驗(yan)電壓(ya)(ya)的(de)75%后,再(zai)以每(mei)秒(miao)2%額定試(shi)驗(yan)電壓(ya)(ya)的(de)速度(du)升(sheng)(sheng)到(dao)您(nin)所需的(de)試(shi)驗(yan)電壓(ya)(ya),并(bing)密切注意測量(liang)儀(yi)表的(de)及被試(shi)品的(de)情況。升(sheng)(sheng)壓(ya)(ya)過程中或(huo)試(shi)驗(yan)過程中如發現測量(liang)儀(yi)表的(de)指示及被試(shi)品情況異常(chang),應立即(ji)降壓(ya)(ya),切斷電源,查明情況。
4、試驗完畢后,應在(zai)數(shu)秒(miao)內勻速的將調壓器(qi)返(fan)回至零位,然后切斷(duan)電源。本產品不得超過額(e)定參數(shu)使用(yong)。
5、使用本產品做高壓試驗(yan)時(shi),除熟悉本說明書外,還必須嚴格執行(xing)國家有關標準和操作規程(cheng)。可參照GB311.1 – 97《高壓輸變設備的絕緣配合,高壓試驗(yan)技(ji)術》;《電氣(qi)設備預(yu)防性試驗(yan)規程(cheng)》等(deng)
一、概述(shu)
智(zhi)能耐(nai)壓(ya)(ya)試(shi)驗(yan)裝置是根據國家*新電(dian)力行(xing)(xing)業標準而設(she)計的、性(xing)能先進的智(zhi)能型耐(nai)壓(ya)(ya)試(shi)驗(yan)設(she)備,用(yong)于(yu)對(dui)各種(zhong)電(dian)器產(chan)(chan)品(pin)、電(dian)氣(qi)元件(jian)、絕緣材(cai)料等進行(xing)(xing)規定電(dian)壓(ya)(ya)下的絕緣強度試(shi)驗(yan),以考核產(chan)(chan)品(pin)的絕緣水(shui)平,發現被試(shi)品(pin)的絕緣缺陷(xian),衡量(liang)過電(dian)壓(ya)(ya)的能力。廣泛應(ying)用(yong)于(yu)電(dian)工(gong)制(zhi)造部門、電(dian)力運行(xing)(xing)部門、科研單位(wei)和(he)高等院校。
二、產品特(te)點
1. 320×240液晶顯示器(qi)、高速(su)熱敏打印機。
2. 高(gao)(gao)(gao)壓電壓、高(gao)(gao)(gao)壓電流、低(di)壓電壓、低(di)壓電流4路測量方式(shi),高(gao)(gao)(gao)精度(du)傳感器和(he)高(gao)(gao)(gao)性能14位(wei)AD采集芯片。
3. 人機對(dui)話全(quan)鍵盤(pan)操作方(fang)(fang)式(shi)(shi),智能化工作全(quan)過程,任選自(zi)動方(fang)(fang)式(shi)(shi)和手動方(fang)(fang)式(shi)(shi)。
4. 實(shi)時顯示高壓(ya)(ya)(ya)電壓(ya)(ya)(ya)、高壓(ya)(ya)(ya)電流、低(di)壓(ya)(ya)(ya)電壓(ya)(ya)(ya)、低(di)壓(ya)(ya)(ya)電流,時間及耐(nai)壓(ya)(ya)(ya)結果(guo),顯示直觀明了。
5. 完善的過壓(ya)、過流(liu)(liu)保護,任(ren)意設定輸出電壓(ya)、高壓(ya)電流(liu)(liu)上限(xian)、低壓(ya)電流(liu)(liu)上限(xian)和計時時間(jian)。
6. 具有回(hui)零檢(jian)測(ce)功能,回(hui)零確定后才可進行試驗,**可靠(kao)。
7. 具(ju)有絕(jue)緣(yuan)電阻測試功(gong)能,直接反映被試品絕(jue)緣(yuan)強(qiang)度。
8. 逼近式調壓算(suan)法(fa),到(dao)達設(she)定電壓后自動耐壓計(ji)時,計(ji)時結束(shu)后自動降壓回零。
9. 超過(guo)設定(ding)高壓電(dian)流(liu)(liu)或低壓電(dian)流(liu)(liu)時自動切斷電(dian)壓輸(shu)出,降壓回(hui)零,并發生聲光報(bao)警。
10. 精(jing)良的軟硬件抗干(gan)擾設計,多種抗干(gan)擾手段,適(shi)應(ying)惡劣電(dian)磁環境。
11. 自動錯(cuo)誤診斷,易于發現(xian)和解(jie)決問(wen)題。
12. 可選配(pei)無線遙控(kong)控(kong)制(zhi)功(gong)能、遠程通信、門聯鎖(suo)警鈴、外(wai)接分(fen)壓(ya)器校驗接口等(deng)。
三、設備組成
1、選型配置
標(biao)準配(pei)置
|
□ 分體式
|
操作部分(fen):
□箱(xiang)式(不大(da)于(yu)5kVA) / □臺式
容(rong)量: kVA(小于(yu)200kVA)
輸入:□AC220V / □AC380V
|
試驗變壓器:
□交(jiao)流 / □交(jiao)直流
□油變(bian) / □干變(bian) / □氣變(bian)
容(rong)量: kVA(小于200kVA)
輸出:AC kV(小于300kVA)
|
□ 一體式
|
□箱式(不(bu)大于20kV) / □臺式(不(bu)大于30kV)
容量: kVA(小于(yu)300kVA)
輸入:□AC220V / □AC380V 輸出:AC kV(不大于30kV)
|
客戶選配
|
□標準高壓分壓器
|
□保護球隙(xi)
|
□直流微安表
|
□放**
|
□保護水阻
|
□高壓(ya)濾波(bo)電容
|
其它:
|
2、對應實物
四、技術指標(biao)
1、使用(yong)條件:
(1)工作場所應無嚴重影響(xiang)絕(jue)緣的氣體、蒸汽、化(hua)學性(xing)塵(chen)埃及其它爆炸性(xing)和(he)腐(fu)蝕性(xing)介質。
(2)環(huan)境溫度 -20~+50℃
(3)環境濕度 ≤85% RH(無凝結水)
2、控制箱(xiang)(臺)參數:(常(chang)規參數見下表)
(1)計(ji)時范圍(wei):0-999S
(3)電壓精度 ≤1.5% ±1個字(F.S)
(4)電流精度 ≤1.5% ±1個字(zi)(F.S)
規(gui)格
|
容量
|
輸 入 電(dian) 源
|
輸 出 電(dian) 壓(ya)
|
重量(kg)
|
相(xiang)數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說明:如(ru)有特殊(shu)參數(shu)(shu)要(yao)求,可按用戶的技術參數(shu)(shu)進行設計(ji)制作(zuo)。
3、試驗(yan)變壓器參數(shu):(常(chang)規參數(shu)見(jian)下表)
規格(ge)
|
容量
kVA
|
低壓(ya)側
|
高(gao)壓側(ce)
|
高壓(ya)側(交直流變壓(ya)器)
|
測量(liang)變比
|
60分鐘溫升℃
|
阻(zu)抗電壓%
|
空載電流
%
|
質(zhi)量(liang)
kg
|
電壓
V
|
電(dian)流
A
|
交流輸出
|
直流輸出
|
電壓kV
|
電流(liu)
|
電壓kV
|
電流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說(shuo)明:如有特(te)殊(shu)參數(shu)要求,可(ke)按用戶的技術參數(shu)進行設計制作。
上(shang)表的重量以油浸式試驗變壓器(qi)(qi)為例(li),干式試驗變壓器(qi)(qi)和(he)充(chong)氣式試驗變壓器(qi)(qi)稍有不同。
五、接線及工作(zuo)原(yuan)理
1、調壓部分接線及原理
調壓(ya)部(bu)(bu)分(fen)由控(kong)(kong)制部(bu)(bu)分(fen)和試驗(yan)變(bian)壓(ya)器(qi)(qi)組(zu)(zu)成(cheng)。控(kong)(kong)制部(bu)(bu)分(fen)是由接(jie)觸式調壓(ya)器(qi)(qi)、單片機(ji)控(kong)(kong)制系統、液晶、打印機(ji)、信號測量、電(dian)路(lu)保(bao)護組(zu)(zu)成(cheng)。試驗(yan)變(bian)壓(ya)器(qi)(qi)由低(di)壓(ya)繞(rao)組(zu)(zu)、高壓(ya)繞(rao)組(zu)(zu)、儀表繞(rao)組(zu)(zu)三部(bu)(bu)分(fen)組(zu)(zu)成(cheng)。
試(shi)驗(yan)(yan)變(bian)壓(ya)器為(wei)交直流兩(liang)用時(shi),試(shi)驗(yan)(yan)變(bian)壓(ya)器配置(zhi)了(le)高(gao)壓(ya)硅(gui)堆(dui)(油(you)變(bian)、氣(qi)變(bian)為(wei)內置(zhi),干(gan)(gan)變(bian)為(wei)外(wai)(wai)置(zhi)),高(gao)壓(ya)可輸(shu)出交流和直流。輸(shu)出交流時(shi),要求接入短路(lu)桿(油(you)變(bian)、氣(qi)變(bian))或去(qu)掉外(wai)(wai)置(zhi)硅(gui)堆(dui)(干(gan)(gan)變(bian));輸(shu)出直流時(shi),要求擰出短路(lu)桿(油(you)變(bian)、氣(qi)變(bian))或加(jia)上外(wai)(wai)置(zhi)硅(gui)堆(dui)(干(gan)(gan)變(bian))
通過(guo)接入工(gong)頻電(dian)源,調(diao)節(jie)調(diao)壓器,以(yi)獲得所需(xu)要(yao)的試驗高壓電(dian)壓值。其工(gong)作原理(li)見圖1:
2、試驗部分(fen)接線及(ji)原(yuan)理
做耐(nai)(nai)壓(ya)試(shi)驗(yan)時,控制部分(fen)、變壓(ya)器的(de)接(jie)地端及高壓(ya)尾必須(xu)可靠接(jie)地。有條件的(de)情況下,做工(gong)頻耐(nai)(nai)壓(ya)試(shi)驗(yan)請加(jia)上限流電阻、標(biao)準高壓(ya)分(fen)壓(ya)器、球(qiu)隙保護電阻及保護球(qiu)隙,如圖3。
做直流耐(nai)壓試(shi)驗請另外加上(shang)微(wei)安(an)表,微(wei)安(an)表必須接在(zai)(zai)硅(gui)堆和(he)被試(shi)器(qi)(qi)之間,油(you)變(bian)(bian)或氣變(bian)(bian)一(yi)般擰在(zai)(zai)高壓頭上(shang)面(要求擰出短路桿),干變(bian)(bian)擰在(zai)(zai)外置硅(gui)堆上(shang)面;為了更準確顯示高壓直流泄漏電流,請將分壓器(qi)(qi)的高壓線接在(zai)(zai)微(wei)安(an)表和(he)硅(gui)堆之間,(油(you)變(bian)(bian)、氣變(bian)(bian))如(ru)圖(tu)4,(干變(bian)(bian))如(ru)圖(tu)5。
耐壓試(shi)驗(yan)中限流(liu)電(dian)阻(zu)R1應(ying)根據試(shi)驗(yan)變壓器的額定(ding)容(rong)量來選(xuan)擇。如高壓側額定(ding)輸(shu)出電(dian)流(liu)在(zai)100~300mA時,可(ke)取(qu)0.5~1Ω/V(試(shi)驗(yan)電(dian)壓);高壓側額定(ding)輸(shu)出電(dian)流(liu)為(wei)1A以上時,可(ke)取(qu)1Ω/V(試(shi)驗(yan)電(dian)壓)。常用(yong)水電(dian)阻(zu)作為(wei)限流(liu)電(dian)阻(zu),管子長(chang)度(du)可(ke)按150kV/m考慮,管子粗(cu)細應(ying)具有足(zu)夠(gou)的熱容(rong)量(水阻(zu)液配(pei)制方法(fa):用(yong)蒸餾水加入適量硫酸(suan)銅配(pei)制成(cheng)各(ge)種不同的阻(zu)值(zhi))。
球(qiu)間(jian)隙及(ji)保(bao)護(hu)電(dian)(dian)阻:當電(dian)(dian)壓超過球(qiu)間(jian)隙整定值時(一般取試(shi)驗電(dian)(dian)壓的(de)110%~120%),球(qiu)間(jian)隙放電(dian)(dian),對被試(shi)品(pin)起到保(bao)護(hu)作用。球(qiu)間(jian)隙保(bao)護(hu)電(dian)(dian)阻可按1Ω/V(試(shi)驗電(dian)(dian)壓)選取。
在(zai)(zai)工(gong)頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)中,低電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)測(ce)量(liang)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(儀表電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya))不是非常準(zhun)確的(de),其原因是由于(yu)試(shi)(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)存在(zai)(zai)著漏抗(kang),在(zai)(zai)這個漏抗(kang)上(shang)(shang)必(bi)然存在(zai)(zai)著壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)降或容(rong)升,使試(shi)(shi)(shi)品上(shang)(shang)的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)低于(yu)或高(gao)于(yu)低壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)測(ce)量(liang)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)表上(shang)(shang)反映出來的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)。工(gong)頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)時(shi),被試(shi)(shi)(shi)品上(shang)(shang)的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)高(gao)于(yu)試(shi)(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)的(de)輸出電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya),也(ye)就是所謂容(rong)升現象(xiang)。感應耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)時(shi),試(shi)(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)的(de)漏抗(kang)必(bi)然存在(zai)(zai)著壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)降。為(wei)了準(zhun)確測(ce)量(liang)被試(shi)(shi)(shi)品上(shang)(shang)所施(shi)加的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya),因此常在(zai)(zai)高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)接入標(biao)準(zhun)高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)分(fen)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)來測(ce)量(liang)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)。
六、操作要(yao)點
1、試(shi)驗(yan)前,應了解(jie)被(bei)試(shi)品(pin)的試(shi)驗(yan)電壓,同時了解(jie)被(bei)試(shi)品(pin)的其他試(shi)驗(yan)項目及以前的試(shi)驗(yan)結果(guo)。若被(bei)試(shi)品(pin)有缺(que)陷或異常,應在消除后再進行耐壓試(shi)驗(yan)。
2、試驗現場應圍好遮(zhe)攔(lan)或圍繩,掛(gua)好標(biao)示牌,并派專人監護。
3、試驗前,被試品(pin)表面(mian)應(ying)擦拭干凈,將被試品(pin)的外(wai)殼(ke)和非被試繞組(zu)可靠接地。被試品(pin)為新(xin)沖油(you)設備時(shi)(shi),應(ying)按《規(gui)程(cheng)》規(gui)定使油(you)靜(jing)止一定時(shi)(shi)間(jian)(jian)再升壓(ya),對(dui)110kV及以下的充(chong)油(you)電力(li)設備,在注滿油(you)后靜(jing)置(zhi)(zhi)時(shi)(shi)間(jian)(jian)應(ying)不少(shao)于24小時(shi)(shi),對(dui)220kV及330kV的充(chong)油(you)電力(li)設備,靜(jing)置(zhi)(zhi)時(shi)(shi)間(jian)(jian)應(ying)不少(shao)于48小時(shi)(shi)。
4、接好(hao)試(shi)驗(yan)接線后(hou),應由有經驗(yan)的人員檢查,確認無誤后(hou)方可升壓。
5、升壓(ya)前,首先檢查(cha)調壓(ya)器是否(fou)在(zai)零(ling)位(wei)。調壓(ya)器在(zai)零(ling)位(wei)方可升壓(ya)。
6、升壓(ya)(ya)(ya)過程(cheng)中不(bu)僅要監(jian)視電壓(ya)(ya)(ya)的變化(hua),還應監(jian)視電流的變化(hua),以及被試品泄(xie)漏(lou)電流的變化(hua)。升壓(ya)(ya)(ya)時(shi)要均(jun)勻(yun)升壓(ya)(ya)(ya),不(bu)能(neng)太快。升至規定試驗電壓(ya)(ya)(ya)時(shi),開始(shi)計時(shi),時(shi)間到后(hou),緩(huan)慢均(jun)勻(yun)降下電壓(ya)(ya)(ya)。絕不(bu)允許(xu)不(bu)降壓(ya)(ya)(ya)就先跳(tiao)開電源開關。
7、試驗(yan)中(zhong)發現被試品有異(yi)常聲響、冒煙等應(ying)立即降下電壓(ya),拉(la)開(kai)電源,在高壓(ya)側掛上接地線后,再查明原因。耐壓(ya)試驗(yan)前(qian)后均應(ying)測量(liang)被試品的絕緣電阻。
七、面板功能說明
打(da)(da)印(yin)機(ji):打(da)(da)印(yin)機(ji)是熱敏(min)打(da)(da)印(yin)機(ji),當試驗完成后(hou)按(an)鍵盤上的“打(da)(da)印(yin)”按(an)鈕(niu)打(da)(da)印(yin)試驗結果(guo)。
RS232:RS232是與計算機(ji)相連的串口(kou)通(tong)信接口(kou),是用戶選配(pei)接口(kou),本裝置沒有配(pei)置這個接口(kou)。
LCD對比度(du):因為液晶顯示屏(ping)在溫度(du)和光線有所不同時(shi)稍有些變化,可(ke)以通(tong)過LCD對比度(du)調節(jie)背光到適合亮(liang)度(du)。
液晶: 320x240像素點陣白(bai)色(se)背光(guang)液晶,在強光(guang)和陰暗(an)環境(jing)下都十(shi)分清楚。
指示(shi)燈:由啟動燈、零位燈、指示(shi)燈三(san)個燈組成(cheng),啟動燈和警示(shi)燈是高亮七彩燈。
操(cao)作(zuo)提示:有一些簡(jian)短(duan)的提示語句和安裝(zhuang)接線圖。
緊(jin)急開(kai)(kai)關:在(zai)緊(jin)急情(qing)況下按(an)此開(kai)(kai)關,即可以切斷變(bian)壓器(qi)電(dian)源(yuan),也(ye)可以切斷工作電(dian)源(yuan)。(箱式(shi)安裝在(zai)面板(ban)上(shang),臺(tai)式(shi)安裝在(zai)柜體上(shang))
鍵盤:由(you)上、下、左、右、設(she)置、打印(yin)、確定、取消8個鍵組成,是(shi)用戶和設(she)備交互的終端。
電源(yuan)開(kai)關:工作(zuo)電源(yuan),帶通電指(zhi)示燈。
八、軟件使用說明
按試(shi)(shi)驗要(yao)求(qiu)將(jiang)控(kong)制(zhi)部分、試(shi)(shi)驗變壓器、被試(shi)(shi)品正確接好線,必須可靠接地,請參考(kao)圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5。
1、開機使用
開機處于(yu)“歡迎界面”,如圖(tu)7:
根據鍵盤的示圖8,按上↑、下↓、左←,右→可以切換(huan)“自(zi)動(dong)耐壓試(shi)驗(yan)”或“手(shou)(shou)動(dong)耐壓試(shi)驗(yan)”,在“自(zi)動(dong)試(shi)驗(yan)”或“手(shou)(shou)動(dong)試(shi)驗(yan)”里面選擇(ze)“交流試(shi)驗(yan)方(fang)式”或“直流試(shi)驗(yan)方(fang)式”。如圖9
說(shuo)明:
(1)當(dang)配置的是交直流兩用控制部分(fen)時(shi),使用直流輸出時(shi)軟件操(cao)作(zuo)(zuo)請(qing)進入(ru)直流試驗方式(shi),交流輸出時(shi)軟件操(cao)作(zuo)(zuo)請(qing)進入(ru)交流試驗方式(shi),如果選擇(ze)錯誤會導致(zhi)儀器(qi)顯示電壓(ya)會和輸出實(shi)際電壓(ya)不一致(zhi)。
(2)當配置的(de)是交直(zhi)流(liu)兩用變壓器(qi)時,使(shi)用直(zhi)流(liu)時請(qing)將變壓器(qi)的(de)短路(lu)桿(gan)取出(chu),當使(shi)用交流(liu)時請(qing)將短路(lu)桿(gan)插入擰緊。
(3)如果(guo)配置的是交流(liu)控制部分時,軟(ruan)件界面里(li)就沒有交直流(liu)試(shi)驗方(fang)式(shi)(如圖(tu)9)的選擇項。
選中(zhong)試(shi)驗方式(shi)后,按確定可以進入主界(jie)面,如圖10:
動態(tai)顯示(shi)區:一直處于采集(ji)信號,并顯示(shi)高壓(ya)(ya)(ya)電(dian)(dian)壓(ya)(ya)(ya)、高壓(ya)(ya)(ya)電(dian)(dian)流(liu)、低壓(ya)(ya)(ya)電(dian)(dian)壓(ya)(ya)(ya)、低壓(ya)(ya)(ya)電(dian)(dian)流(liu)。
結果顯(xian)示區:如果試驗沒有被擊穿時,顯(xian)示平(ping)均(jun)高(gao)壓(ya)(ya)電壓(ya)(ya),平(ping)均(jun)高(gao)壓(ya)(ya)電流,平(ping)均(jun)低(di)壓(ya)(ya)電壓(ya)(ya),平(ping)均(jun)低(di)壓(ya)(ya)電流,絕緣電阻;否之,顯(xian)示峰(feng)值電壓(ya)(ya),峰(feng)值電流,低(di)壓(ya)(ya)電壓(ya)(ya),低(di)壓(ya)(ya)電流。
設置數據區:設置試(shi)驗中需要的(de)參數數據輸出電(dian)(dian)(dian)壓(ya)(ya)為在自(zi)動方式下的(de)升壓(ya)(ya)目標(biao)耐(nai)壓(ya)(ya)值耐(nai)壓(ya)(ya)時(shi)間為耐(nai)壓(ya)(ya)過(guo)(guo)程(cheng)的(de)時(shi)間長度電(dian)(dian)(dian)流(liu)(liu)(liu)上(shang)限為高壓(ya)(ya)電(dian)(dian)(dian)流(liu)(liu)(liu)峰(feng)值的(de)上(shang)限,高壓(ya)(ya)電(dian)(dian)(dian)流(liu)(liu)(liu)超過(guo)(guo)電(dian)(dian)(dian)流(liu)(liu)(liu)上(shang)限將認(ren)為擊穿過(guo)(guo)流(liu)(liu)(liu)保護為低(di)壓(ya)(ya)電(dian)(dian)(dian)流(liu)(liu)(liu)峰(feng)值的(de)上(shang)限,低(di)壓(ya)(ya)電(dian)(dian)(dian)流(liu)(liu)(liu)超過(guo)(guo)過(guo)(guo)流(liu)(liu)(liu)保護將認(ren)為擊穿
信(xin)息顯示(shi)區:顯示(shi)試(shi)驗(yan)過程中的試(shi)驗(yan)狀態和提(ti)示(shi)信(xin)息。
試驗操作區(qu):選擇設置(zhi)、試驗、回(hui)零命令。
2、設置參數(shu)
在主界面上(shang),選中“設(she)置”,然后按確定后進入(ru)設(she)置界面,如圖11:
按左←,右→時切換光標(biao)移動位置(zhi),按上↑、下↓時更改光標(biao)位置(zhi)數(shu)(shu)據的(de)值(zhi)。光標(biao)位置(zhi)和(he)設(she)置(zhi)的(de)數(shu)(shu)值(zhi)全部(bu)可(ke)以(yi)自動循環,前(qian)且(qie)在(zai)使用時有默認的(de)標(biao)準值(zhi)。如果所有的(de)參(can)數(shu)(shu)都設(she)置(zhi)完成,按取消退出設(she)置(zhi)回到(dao)主界面(mian)開始(shi)狀態。
3、手動試(shi)驗
零(ling)位(wei)檢查—當(dang)選(xuan)中“試(shi)驗(yan)”后,按確定就進入提(ti)示試(shi)驗(yan)狀態。如(ru)果調壓器不在零(ling)位(wei),將提(ti)示“試(shi)驗(yan)前請先回零(ling)”,退出(chu)試(shi)驗(yan)并且切換到回零(ling)命令(ling)。
試(shi)(shi)驗過程—回零確認后(hou),可以(yi)進行試(shi)(shi)驗。選(xuan)中“試(shi)(shi)驗”后(hou)按(an)確定,接觸(chu)器合閘,這時輸出電壓幾乎為0,如圖12:
按上↑,高壓電壓將(jiang)不斷(duan)升壓,松開(kai)就停止升壓,如(ru)果到上限就提示(shi)滿(man)量程;
按下↓,高壓(ya)電壓(ya)將不斷降壓(ya),松(song)開就(jiu)停止降壓(ya),如果到下限就(jiu)提示已(yi)回(hui)零;
按計時(shi)←,計時(shi)開(kai)始工作,到耐壓時(shi)間計時(shi)結束完成試驗(yan);
按取消(xiao)→,取消(xiao)試(shi)驗過程;
在升(sheng)壓(ya)(ya)過程(cheng)(cheng)中,如果(guo)高壓(ya)(ya)電(dian)(dian)(dian)流(liu)峰(feng)值(zhi)超(chao)過“電(dian)(dian)(dian)流(liu)上限”值(zhi)或低(di)(di)壓(ya)(ya)電(dian)(dian)(dian)流(liu)峰(feng)值(zhi)超(chao)過“過流(liu)保護”值(zhi)將認為被試(shi)品被擊穿(chuan),接觸(chu)器立(li)刻(ke)分(fen)(fen)閘(zha)并顯示試(shi)驗結果(guo),包括峰(feng)值(zhi)電(dian)(dian)(dian)壓(ya)(ya)、峰(feng)值(zhi)電(dian)(dian)(dian)流(liu)、低(di)(di)壓(ya)(ya)電(dian)(dian)(dian)流(liu)等,調壓(ya)(ya)器開(kai)(kai)始回零(ling)(ling),回零(ling)(ling)完成試(shi)驗結束(shu)(shu)。如果(guo)在耐(nai)壓(ya)(ya)過程(cheng)(cheng)中,高壓(ya)(ya)電(dian)(dian)(dian)流(liu)和低(di)(di)壓(ya)(ya)電(dian)(dian)(dian)流(liu)峰(feng)值(zhi)沒有(you)超(chao)設置上限值(zhi),認為被試(shi)品未擊穿(chuan),結果(guo)顯示區(qu)就顯示耐(nai)壓(ya)(ya)電(dian)(dian)(dian)壓(ya)(ya)、高壓(ya)(ya)電(dian)(dian)(dian)流(liu)、低(di)(di)壓(ya)(ya)電(dian)(dian)(dian)流(liu)、絕緣(yuan)電(dian)(dian)(dian)阻等,調壓(ya)(ya)器開(kai)(kai)始回零(ling)(ling),回零(ling)(ling)完成后接觸(chu)器分(fen)(fen)閘(zha)試(shi)驗結束(shu)(shu)。
4、自(zi)動(dong)試驗
自(zi)動(dong)試(shi)驗(yan)和手(shou)動(dong)試(shi)驗(yan)的試(shi)驗(yan)過程(cheng)類似(si),首(shou)先也(ye)進行回(hui)零檢(jian)查,確認后進入如下界面(mian),如圖(tu)13:
按(an)上方法切換到“開(kai)始”確定后進(jin)(jin)行試(shi)驗,與手(shou)動試(shi)驗不同之處就(jiu)是升壓過程將自動升壓到“輸(shu)出電壓”值,然后進(jin)(jin)行計時。
升(sheng)壓(ya)過程為逼近(jin)方式,首先升(sheng)到到接近(jin)目(mu)標值,然后(hou)再進(jin)行微調,保證高壓(ya)電(dian)壓(ya)值幾乎為輸出電(dian)壓(ya)值。
5、功能選擇
按鍵盤上的“設置”就進入功能界面,如(ru)圖(tu)14:
進入功能界面(mian)后,可以選(xuan)擇(ze)“時鐘設置”、“注意事項”等界面(mian)。
時(shi)鐘(zhong)設(she)(she)置:設(she)(she)置時(shi)鐘(zhong)的時(shi)間,為打印報表提供時(shi)間依據。
注意事項:為用戶提供一(yi)些操(cao)作(zuo)規(gui)范和**注意事項。
6、打印
按鍵盤“打印”按鍵可以(yi)打印試驗果,在(zai)此不(bu)贅述。
七、產(chan)品維護
1、開箱驗(yan)收時,應檢(jian)查主控回路接(jie)線(xian)是(shi)否松(song)動,調壓器(qi)電刷(shua)是(shi)否接(jie)觸良好。
2.、長期不用時,使用前應用500V兆(zhao)歐(ou)表測(ce)量絕緣電阻(zu),其阻(zu)值不低于0.5MΩ。
3、電(dian)源(yuan)電(dian)壓(ya)應符(fu)合控制(zhi)箱(xiang)(臺(tai))說明書上的輸(shu)入電(dian)壓(ya)值要求(qiu)。
4、本(ben)控制(zhi)箱(臺)設有過電(dian)流保護,出廠(chang)已調整為(wei)額(e)定電(dian)流的50%。用于小負載時,應根據被試品(pin)的額(e)定容量電(dian)流重新設定;
5、使用完畢后,應(ying)關(guan)好控制箱(臺)門(men)蓋(gai),以保(bao)持(chi)內(nei)部清(qing)潔。
八(ba)、注意(yi)事項(xiang)
1、按照您所進(jin)行的(de)(de)試(shi)(shi)驗(yan)(yan)接好(hao)工作線路。試(shi)(shi)驗(yan)(yan)變壓器(qi)(qi)的(de)(de)外殼以及操作系統的(de)(de)外殼必須(xu)可(ke)靠接地。試(shi)(shi)驗(yan)(yan)變壓器(qi)(qi)的(de)(de)測量繞組的(de)(de)F端和外殼必須(xu)可(ke)靠接地。
2、做串級(ji)試(shi)驗(yan)(yan)時(shi),**級(ji)、第(di)三(san)級(ji)試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)(ya)器(qi)的(de)低壓(ya)(ya)(ya)(ya)繞組成X端(duan)(duan),測量繞組的(de)F端(duan)(duan)以及高壓(ya)(ya)(ya)(ya)繞組的(de)X端(duan)(duan)(高壓(ya)(ya)(ya)(ya)端(duan)(duan))均接(jie)本(ben)級(ji)試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)(ya)器(qi)具外殼。**級(ji)、第(di)三(san)級(ji)試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)(ya)器(qi)的(de)外殼必須通過絕(jue)緣支(zhi)架接(jie)地。
接通電(dian)源前,控制箱(臺)的調壓(ya)(ya)器必須調到零位后方可接通電(dian)源,合(he)閘(zha),開始升壓(ya)(ya)。
3、從零開始(shi)勻速(su)旋轉(zhuan)調壓(ya)(ya)(ya)(ya)(ya)器手輪升(sheng)壓(ya)(ya)(ya)(ya)(ya)。升(sheng)壓(ya)(ya)(ya)(ya)(ya)方式(shi)有:快速(su)升(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa),即20s逐(zhu)(zhu)級(ji)(ji)升(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa);慢(man)速(su)升(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa),即60s逐(zhu)(zhu)級(ji)(ji)升(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa);極慢(man)速(su)升(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa)供選用(yong)。電(dian)壓(ya)(ya)(ya)(ya)(ya)從零開始(shi)按一定(ding)的(de)升(sheng)壓(ya)(ya)(ya)(ya)(ya)方式(shi)和速(su)度(du)(du)上升(sheng)到您(nin)所需的(de)額定(ding)試(shi)驗(yan)電(dian)壓(ya)(ya)(ya)(ya)(ya)的(de)75%后(hou),再以每秒2%額定(ding)試(shi)驗(yan)電(dian)壓(ya)(ya)(ya)(ya)(ya)的(de)速(su)度(du)(du)升(sheng)到您(nin)所需的(de)試(shi)驗(yan)電(dian)壓(ya)(ya)(ya)(ya)(ya),并密切注意測量儀(yi)表(biao)的(de)及被(bei)(bei)試(shi)品的(de)情況(kuang)。升(sheng)壓(ya)(ya)(ya)(ya)(ya)過程(cheng)中(zhong)或試(shi)驗(yan)過程(cheng)中(zhong)如(ru)發(fa)現測量儀(yi)表(biao)的(de)指示及被(bei)(bei)試(shi)品情況(kuang)異常,應立(li)即降壓(ya)(ya)(ya)(ya)(ya),切斷(duan)電(dian)源,查明情況(kuang)。
4、試(shi)驗完畢后(hou),應(ying)在等調壓(ya)器返回(hui)至(zhi)零位,然后(hou)切斷(duan)電源(yuan)。
5、本產品不(bu)得超過額定參數使用(yong)。
6、使用本(ben)產品做高壓試(shi)(shi)驗時,除熟悉本(ben)說明書外,還(huan)必須嚴格執行國家有(you)關標準和操作規程(cheng)。可(ke)參照GB311.1 – 97《高壓輸(shu)變設備的絕緣配合,高壓試(shi)(shi)驗技術》;《電氣(qi)設備預防性試(shi)(shi)驗規程(cheng)》等。
7、控(kong)(kong)制箱(臺)應與試驗變(bian)壓器配套(tao)使用,控(kong)(kong)制箱(臺)的使用方法,請(qing)詳細(xi)參閱控(kong)(kong)制器的使用說明書。