一、WBYD2000諧振變壓器基本原理
耐(nai)壓試(shi)(shi)驗是利用電(dian)(dian)(dian)(dian)(dian)抗器的(de)電(dian)(dian)(dian)(dian)(dian)感與(yu)被試(shi)(shi)品(pin)電(dian)(dian)(dian)(dian)(dian)容(rong)組成(cheng)LC串聯回路,調(diao)節變頻(pin)電(dian)(dian)(dian)(dian)(dian)源輸出的(de)電(dian)(dian)(dian)(dian)(dian)壓頻(pin)率,在被試(shi)(shi)品(pin)上(shang)獲得高電(dian)(dian)(dian)(dian)(dian)壓,是當前高電(dian)(dian)(dian)(dian)(dian)壓試(shi)(shi)驗的(de)一種新(xin)方(fang)法,深(shen)受專家(jia)好(hao)評,在國內外已經得到(dao)廣泛(fan)的(de)使用。
根(gen)據(ju)諧振(zhen)原理,我(wo)們知(zhi)道當電(dian)抗(kang)器L的感抗(kang)值Xl與(yu)回路中的容抗(kang)值Xc相等時(shi),回路達(da)到諧振(zhen)狀態,此(ci)時(shi)回路中僅回路電(dian)阻(zu)R消耗有(you)功(gong)功(gong)率,而(er)(er)無功(gong)功(gong)率則(ze)在(zai)電(dian)抗(kang)器與(yu)試(shi)品電(dian)容之(zhi)間來(lai)回振(zhen)蕩,從而(er)(er)在(zai)試(shi)品上(shang)產生高壓。
二、WBYD2000諧振變壓器系統構成
全套試(shi)驗系統(tong)由調(diao)頻電(dian)源主機、電(dian)抗器、分壓器、激勵(li)變壓器和補償電(dian)容器(可選器件)組成(cheng),接(jie)入被(bei)試(shi)品后(hou)組成(cheng)一個諧振(zhen)系統(tong)進行交流耐壓實驗。
主機: 就(jiu)是一(yi)臺幅值和頻(pin)率可調的正弦波交(jiao)流調頻(pin)電(dian)源,給諧振(zhen)回路提(ti)供(gong)激勵源,同(tong)時(shi)提(ti)供(gong)電(dian)壓顯示、電(dian)流顯示、計時(shi)、保護、報警(jing)等功能。
電(dian)(dian)抗器:就(jiu)是一個大電(dian)(dian)感線圈,與被試品(相當于電(dian)(dian)容)構成回路,可配置(zhi)電(dian)(dian)抗器多(duo)節電(dian)(dian)抗器,使用(yong)時通(tong)過不(bu)同(tong)的(de)(de)串聯、并聯組合、實現不(bu)同(tong)的(de)(de)電(dian)(dian)感量以適(shi)用(yong)不(bu)同(tong)的(de)(de)試驗條(tiao)件。
分(fen)壓(ya)器(qi):內部通(tong)過電容器(qi)分(fen)壓(ya),從(cong)試品(pin)上(shang)高電壓(ya)分(fen)得低電壓(ya)供主機測量、控(kong)制(zhi)使用。
勵(li)磁變壓器:隔離主(zhu)(zhu)機(ji)電源與諧振回路電源,并升高主(zhu)(zhu)機(ji)的(de)輸出電壓。
補(bu)償電(dian)(dian)(dian)容(rong)器:當(dang)試品(pin)電(dian)(dian)(dian)容(rong)量(liang)很小時,如果(guo)要實(shi)現(xian)系(xi)統(tong)諧振可能要求(qiu)的(de)電(dian)(dian)(dian)源頻率(lv)超出試驗標準的(de)規定,可在試品(pin)上并聯一個(ge)補(bu)償電(dian)(dian)(dian)容(rong),以實(shi)現(xian)試驗要求(qiu),稱(cheng)此電(dian)(dian)(dian)容(rong)器為補(bu)償電(dian)(dian)(dian)容(rong)器。
三、WBYD2000諧振變壓器主要技術性能
功率電(dian)源電(dian)壓:AC380V±10%、50Hz;
儀器(qi)電源:220V±10%、50Hz;
諧振輸出容量:200kVA;
儀(yi)器額定電壓:0~200kV;
輸出頻(pin)率范圍(wei):30~300Hz;
輸(shu)出電壓波形(xing):正弦(xian)波,波形(xing)畸(ji)變率(lv)<0.5%;
頻(pin)率調節靈敏(min)度:0.1Hz,不穩定度≤0.05%;
系(xi)統噪(zao)聲:≤60db;
9、系統測(ce)量精度(du):<1級;
10.輸出(chu)電壓不穩(wen)定:<0.5%;
11.保(bao)護響應時間(jian):1us;
12.電感非(fei)線性度:≤0.05%;;
13.滿功率輸出下,連續工作時間(jian)為60min
14.環(huan)境(jing)溫度:-15℃~+50℃;
15.相對濕度:≤90%RH;
16.海拔高度:≤2000米(mi)。
四、WBYD2000諧振變壓器面板及部件名稱
五、WBYD2000諧振變壓器操作步驟
1、正確連線,檢(jian)查無誤后方可送電。
必要時工作(zuo)電源的跳(tiao)過現場漏電保安器(qi),以免不(bu)必要的跳(tiao)閘。
2、打開(kai)電源開(kai)關,主(zhu)機開(kai)始工作,液晶屏顯示版權頁(ye),該頁(ye)標明本裝置的軟件版本號(hao)。
觸(chu)按確認(ren)鍵(jian),進(jin)入系統菜(cai)單(dan),該主菜(cai)單(dan)下有(you):試(shi)(shi)驗(yan)方(fang)案(an)、開始試(shi)(shi)驗(yan)、試(shi)(shi)驗(yan)幫助、系統設置、實用工(gong)具和試(shi)(shi)驗(yan)記(ji)錄等六(liu)個子菜(cai)單(dan)項。
3、 系(xi)統設(she)置(zhi)菜單(dan)下(xia)有電抗器電感、日期時(shi)間設(she)置(zhi)和采樣(yang)系(xi)數(shu)(shu)設(she)置(zhi)等三個子(zi)菜單(dan)項(xiang)(xiang)。按(an)上下(xia)鍵(jian),上下(xia)移動光標系(xi)統參(can)數(shu)(shu)設(she)置(zhi)菜單(dan)項(xiang)(xiang),觸按(an)確定鈕后,進入(ru)系(xi)統參(can)數(shu)(shu)設(she)置(zhi)菜單(dan),可以分(fen)別設(she)定電抗器的(de)電感—H、-年-月-日、-時(shi)-分(fen)-秒和電壓(ya)和電流的(de)采樣(yang)系(xi)數(shu)(shu)也就是(shi)采樣(yang)倍率,設(she)定完成后,觸按(an)返(fan)還鍵(jian)返(fan)回上**菜單(dan)。
電抗器電感量的(de)設定(ding)(ding)(ding):按(an)確定(ding)(ding)(ding)鍵選擇(ze)到此項,按(an)左右鍵移動光標需要改變的(de)數(shu)位,按(an)上下鍵改變數(shu)值,達到所要達到的(de)數(shu)值按(an)確定(ding)(ding)(ding)鍵確認。
日期時間的設定:按(an)(an)(an)確定鍵選(xuan)擇到(dao)此項,按(an)(an)(an)左右鍵移動光標需要改變(bian)的數(shu)位,按(an)(an)(an)上下鍵改變(bian)數(shu)值,按(an)(an)(an)照所要設置的年月(yue)日時間數(shu)值按(an)(an)(an)確定鍵確認。
采(cai)樣(yang)系數的設定(ding)(ding):按確定(ding)(ding)鍵選擇到高壓(ya)/電(dian)流(liu)采(cai)樣(yang)系數項,此項為電(dian)壓(ya)或電(dian)流(liu)采(cai)樣(yang)倍率(lv)的設定(ding)(ding)。一(yi)般出(chu)廠前設定(ding)(ding)好了。如需修改(gai),要輸入密碼。(密碼廠家與設備一(yi)起提供一(yi)般設定(ding)(ding)為:188888)
警告(gao)(gao):系統默(mo)認上一次電抗(kang)器(qi)電感、日期時間和采樣系數設(she)(she)定值。如果需改變要(yao)重新設(she)(she)定。電抗(kang)器(qi)電感量(liang)設(she)(she)定值與實際使用的電抗(kang)器(qi)電感量(liang)不(bu)對,會導(dao)(dao)致(zhi)試(shi)(shi)驗報告(gao)(gao)中(zhong)的被(bei)試(shi)(shi)品電容量(liang)不(bu)準(zhun)。其他并不(bu)會影響。采樣系數設(she)(she)置(zhi)不(bu)正(zheng)確,會導(dao)(dao)致(zhi)顯示(shi)電壓電流不(bu)準(zhun)將很有可能會對被(bei)試(shi)(shi)品或試(shi)(shi)驗設(she)(she)備(bei)造成損(sun)壞。
4、試(shi)(shi)驗(yan)(yan)方案(an)菜單下有預置(zhi)(zhi)保護(hu)(hu)電流、找(zhao)(zhao)頻(pin)起(qi)始(shi)(shi)頻(pin)率(lv)、找(zhao)(zhao)頻(pin)結束頻(pin)率(lv)、預定(ding)起(qi)始(shi)(shi)功(gong)率(lv)四個(ge)子(zi)菜單項,分別(bie)設定(ding)本次試(shi)(shi)驗(yan)(yan)的保護(hu)(hu)電流、找(zhao)(zhao)頻(pin)起(qi)始(shi)(shi)頻(pin)率(lv)、找(zhao)(zhao)頻(pin)結束頻(pin)率(lv)、輸出起(qi)始(shi)(shi)功(gong)率(lv),全部設定(ding)完成后,觸按返(fan)還鍵進入(ru)預置(zhi)(zhi)試(shi)(shi)驗(yan)(yan)電壓和預置(zhi)(zhi)試(shi)(shi)驗(yan)(yan)時間設置(zhi)(zhi)菜單。
可以(yi)分(fen)3段時(shi)間設置(zhi)試驗(yan)電壓(ya)和試驗(yan)時(shi)間, 實際(ji)試驗(yan)時(shi),若設定為自動試驗(yan), 裝置(zhi)將按(an)設定的(de)3段電壓(ya)及時(shi)間,按(an)順序分(fen)別加壓(ya), 全部完(wan)成后自動退出.
如果**段(duan)電(dian)壓設(she)(she)為0, 或時間設(she)(she)為0, 那么執行完(wan)**段(duan)試(shi)驗(yan)電(dian)壓加壓后退(tui)出試(shi)驗(yan), 只加壓**段(duan)設(she)(she)定的電(dian)壓.
如(ru)果第三(san)段(duan)電壓(ya)(ya)設為0, 或(huo)時(shi)間設為0, 不執行第三(san)段(duan)加(jia)壓(ya)(ya).
試驗(yan)(yan)方案(an)設置的(de)(de)設定:在試驗(yan)(yan)電壓項中,按確定單鈕(niu)(niu),移動左右光標到需要改變的(de)(de)數(shu)(shu)(shu)位,按上下(xia)單鈕(niu)(niu)以改變當前數(shu)(shu)(shu)位的(de)(de)數(shu)(shu)(shu)值(zhi)大(da)小,觸按返回鈕(niu)(niu)完(wan)成當前數(shu)(shu)(shu)位的(de)(de)數(shu)(shu)(shu)值(zhi)設定,依次(ci)選擇下(xia)一項數(shu)(shu)(shu)值(zhi)的(de)(de)設定,直(zhi)至(zhi)分別完(wan)成試驗(yan)(yan)時間、起始(shi)(shi)頻率、起始(shi)(shi)功率的(de)(de)設置,方可完(wan)成本次(ci)試驗(yan)(yan)的(de)(de)試驗(yan)(yan)方案(an)設置的(de)(de)設定。
出(chu)廠默認(ren)值:試驗電(dian)壓(ya) 20kV、加壓(ya)時間 2min、激勵強度 2%、輸出(chu)電(dian)流20A、頻率范圍30-300Hz。
5、實(shi)用工具菜單下有(you)
頻(pin)率(lv)(lv)計算:在實驗前可對諧(xie)振頻(pin)率(lv)(lv)進(jin)行計算。只需輸(shu)入(ru)具(ju)體參與試驗的(de)電感、電容(rong)值并按確定(ding)鍵試驗頻(pin)率(lv)(lv)即直接生成(cheng)。
6、開始試驗(yan)(yan)菜單下有自動試驗(yan)(yan)模式(shi)和手動試驗(yan)(yan)模式(shi)兩種子(zi)菜單可(ke)供(gong)選擇。
按確認鍵(jian)進入所選試驗步驟.
自(zi)(zi)動(dong)試(shi)驗模式的(de)操作:選中自(zi)(zi)動(dong)試(shi)驗模式后,觸(chu)按菜單鈕進入正在自(zi)(zi)動(dong)尋找諧(xie)(xie)振(zhen)點(dian)菜單項,裝置在設定(ding)的(de)頻(pin)率(lv)(lv)范圍內自(zi)(zi)動(dong)尋找諧(xie)(xie)振(zhen)點(dian)(如果(guo)被試(shi)品(pin)電容C和電抗器電感L的(de)實際(ji)諧(xie)(xie)振(zhen)頻(pin)率(lv)(lv)不(bu)在設定(ding)的(de)頻(pin)率(lv)(lv)范圍內,將找不(bu)到諧(xie)(xie)振(zhen)點(dian),此時(shi)根據需(xu)要(yao)調整頻(pin)率(lv)(lv)范圍或調整被試(shi)品(pin)回路(lu)的(de)LC參數(shu))。當(dang)找到諧(xie)(xie)振(zhen)點(dian)時(shi),會有聲(sheng)音提示。
找到諧振點后(hou),裝置自動(dong)進(jin)入正(zheng)在自動(dong)升(sheng)壓菜單項,當升(sheng)到試驗電壓設定的電壓時,裝置停止加壓。
當裝置升到試(shi)(shi)驗(yan)(yan)電壓(ya)設(she)(she)定的電壓(ya)時,設(she)(she)備(bei)停止(zhi)加壓(ya),自動進入(ru)正在加壓(ya)試(shi)(shi)驗(yan)(yan)菜單項(xiang),并(bing)自動記(ji)錄試(shi)(shi)驗(yan)(yan)的加壓(ya)時間,當加壓(ya)時間到達設(she)(she)定時間時,設(she)(she)備(bei)逐步降壓(ya)退(tui)出試(shi)(shi)驗(yan)(yan),完成本(ben)次試(shi)(shi)驗(yan)(yan),進入(ru)試(shi)(shi)驗(yan)(yan)結束菜單項(xiang)。并(bing)可(ke)選(xuan)擇保(bao)存試(shi)(shi)驗(yan)(yan)數(shu)據(ju)或打(da)印試(shi)(shi)驗(yan)(yan)數(shu)據(ju)。
試驗時間的(de)一(yi)(yi)行(xing)顯(xian)示末(mo)端(duan),會(hui)顯(xian)示[一(yi)(yi)段(duan)(duan)(duan)]或[二(er)段(duan)(duan)(duan)]或[三(san)(san)段(duan)(duan)(duan)]字樣,表示當前正在進行(xing)的(de)加壓試驗是預置的(de)一(yi)(yi)段(duan)(duan)(duan),二(er)段(duan)(duan)(duan)或三(san)(san)段(duan)(duan)(duan).
手(shou)(shou)動(dong)試(shi)(shi)驗模式(shi)的(de)操作:選中手(shou)(shou)動(dong)試(shi)(shi)驗模式(shi)后觸按(an)確定鈕(niu),進(jin)入正在試(shi)(shi)驗菜單(dan)項;手(shou)(shou)動(dong)按(an)調(diao)頻(pin)鈕(niu),對應的(de)光標隨之改變到輸(shu)出頻(pin)率(lv)項,可以通過(guo)上(shang)下左右鍵改變頻(pin)率(lv)大小使其試(shi)(shi)驗電(dian)(dian)壓逐步(bu)升高(gao),當升到*高(gao)電(dian)(dian)壓時(shi),繼續(xu)向上(shang)或向下調(diao)整(zheng)頻(pin)率(lv)按(an)鈕(niu),直(zhi)至(zhi)試(shi)(shi)驗電(dian)(dian)壓開始下降;這時(shi)反(fan)調(diao)頻(pin)率(lv),試(shi)(shi)驗電(dian)(dian)壓又逐步(bu)回(hui)升,上(shang)下回(hui)調(diao)頻(pin)率(lv),從(cong)頻(pin)率(lv)的(de)高(gao)位(wei)到低位(wei)逐位(wei)調(diao)整(zheng)*高(gao)電(dian)(dian)壓值時(shi)的(de)頻(pin)率(lv)就是當前的(de)諧振頻(pin)率(lv)。
找到諧振點后(hou),手動(dong)按電(dian)壓(ya)(ya)鈕(niu),光標(biao)到了輸(shu)出功率,隨(sui)之按上下鍵增加(jia)輸(shu)出功率,試(shi)驗(yan)(yan)電(dian)壓(ya)(ya)也逐(zhu)步升高(gao),當升到試(shi)驗(yan)(yan)電(dian)壓(ya)(ya)設(she)定電(dian)壓(ya)(ya)值時(shi),裝置停止(zhi)加(jia)壓(ya)(ya),并有屏幕顯(xian)示提示和聲音提示;自(zi)動(dong)進入(ru)正(zheng)在(zai)加(jia)壓(ya)(ya)試(shi)驗(yan)(yan)菜(cai)單項,并自(zi)動(dong)記(ji)錄試(shi)驗(yan)(yan)的加(jia)壓(ya)(ya)時(shi)間(jian)(jian),當到達加(jia)壓(ya)(ya)時(shi)間(jian)(jian)設(she)定時(shi)間(jian)(jian)時(shi),設(she)備逐(zhu)步降(jiang)壓(ya)(ya)退(tui)出試(shi)驗(yan)(yan),完(wan)成本次試(shi)驗(yan)(yan),進入(ru)試(shi)驗(yan)(yan)結(jie)束菜(cai)單項。
注意:在調(diao)(diao)(diao)(diao)(diao)節(jie)頻(pin)率(lv)調(diao)(diao)(diao)(diao)(diao)整鈕(niu)(niu)的(de)過程(cheng)中,觸按(an)(an)左右(you)鈕(niu)(niu),可(ke)以(yi)改變頻(pin)率(lv)調(diao)(diao)(diao)(diao)(diao)節(jie)的(de)速度(du)實現(xian)(xian)(xian)粗細調(diao)(diao)(diao)(diao)(diao)的(de)切(qie)換。在調(diao)(diao)(diao)(diao)(diao)節(jie)電壓(ya)調(diao)(diao)(diao)(diao)(diao)整鈕(niu)(niu)的(de)過程(cheng)中,向(xiang)下觸按(an)(an)左右(you)鈕(niu)(niu),可(ke)以(yi)改變電壓(ya)的(de)升降(jiang)的(de)速度(du)實現(xian)(xian)(xian)粗細調(diao)(diao)(diao)(diao)(diao)的(de)切(qie)換。觸按(an)(an)調(diao)(diao)(diao)(diao)(diao)頻(pin)、調(diao)(diao)(diao)(diao)(diao)壓(ya)鈕(niu)(niu),實現(xian)(xian)(xian)調(diao)(diao)(diao)(diao)(diao)頻(pin)與調(diao)(diao)(diao)(diao)(diao)壓(ya)間的(de)切(qie)換。
7、進(jin)入試驗(yan)記錄查(cha)詢(xun)(xun)菜單項,查(cha)詢(xun)(xun)以往(wang)和當(dang)前(qian)(qian)試驗(yan)數據(ju)。選擇上(shang)下鍵翻看前(qian)(qian)一(yi)組數據(ju)后(hou)一(yi)組數據(ju);選擇左右鍵可(ke)選擇打印或(huo)刪除當(dang)前(qian)(qian)頁(ye)的內容。
125/456為試(shi)驗數(shu)據(ju)庫(ku)指(zhi)針,分(fen)子是試(shi)驗數(shu)據(ju)的在數(shu)據(ju)庫(ku)的順序數(shu),分(fen)母是當(dang)前的數(shu)據(ju)總數(shu),*多可儲存999組試(shi)驗數(shu)據(ju)。
8、裝置(zhi)和(he)試驗(yan)狀(zhuang)態(tai)菜(cai)單提(ti)示:設備(bei)的(de)(de)使用和(he)升壓(ya)(ya)和(he)耐壓(ya)(ya)試驗(yan)過程中,如果出現影(ying)響試驗(yan)設備(bei)、被試驗(yan)設備(bei)以(yi)及操作人的(de)(de)**情況(kuang),設備(bei)可能出現自動保(bao)護轉臺,并在屏幕(mu)有(you)相應的(de)(de)提(ti)示。
不能諧(xie)振(zhen):如果諧(xie)振(zhen)點不在(zai)諧(xie)振(zhen)頻率設置的范圍內(nei);系(xi)統(tong)連線不正確(que)等現象,裝(zhuang)(zhuang)置將找不到諧(xie)振(zhen)點,這時裝(zhuang)(zhuang)置和試驗(yan)狀態菜單中的不能諧(xie)振(zhen)項被(bei)反白并閃爍。
輸(shu)出保(bao)(bao)護(hu)(hu):如(ru)果裝置(zhi)的電源輸(shu)出電流大于輸(shu)出保(bao)(bao)護(hu)(hu)設定的電流值,裝置(zhi)自動保(bao)(bao)護(hu)(hu),這時裝置(zhi)和試驗狀(zhuang)態菜單中的輸(shu)出保(bao)(bao)護(hu)(hu)項(xiang)被反白并(bing)閃爍。
試(shi)驗(yan)中止:如果在(zai)試(shi)驗(yan)升壓或加壓過程出現閃(shan)絡現象,裝置自動(dong)保護,這時裝置和(he)試(shi)驗(yan)狀(zhuang)態菜單中的輸出保護項被(bei)反白并閃(shan)爍。
9、試(shi)(shi)驗幫助內容包括五(wu)大項分(fen)(fen)別為(wei):1.版本信息(xi)2.接(jie)線示(shi)意3.使用說明4.常(chang)見(jian)問題5.參(can)考(kao)資料.如(ru)常(chang)見(jian)問題FAQ分(fen)(fen)五(wu)幅畫面(mian)顯示(shi)、各(ge)種被試(shi)(shi)品電(dian)力電(dian)纜、變壓(ya)器、發電(dian)機電(dian)容參(can)數(shu)的查(cha)詢:
接(jie)線(xian)示意圖:
10、設(she)備出(chu)廠(chang)參(can)(can)數(shu)設(she)置(zhi)是(shi)生產廠(chang)家的出(chu)廠(chang)設(she)置(zhi)參(can)(can)術和(he)校驗參(can)(can)數(shu),不適(shi)當的設(she)置(zhi)和(he)修改會影響設(she)備性能和(he)高壓試驗的**性,未經廠(chang)家授權(quan)密碼,無法(fa)修改。
警告:正(zheng)常試(shi)驗狀態下,按返回鍵即可(ke)中止(zhi)試(shi)驗。中止(zhi)或(huo)結(jie)束試(shi)驗后,應分離刀閘(zha)切斷電源。在(zai)升壓(ya)或(huo)加壓(ya)過程(cheng)中,非(fei)緊急(ji)情(qing)況,不(bu)要按下急(ji)停鍵。
六、本說明書的專屬名詞的定義
自(zi)動(dong)試驗:高壓試驗全(quan)過(guo)程由主機按程序和預置(zhi)參數自(zi)動(dong)完成。
自(zi)動(dong)調諧:調諧由主(zhu)機按程序自(zi)動(dong)完成(cheng),升壓(ya)手動(dong)完成(cheng)。
手(shou)(shou)動(dong)試驗:尋找諧(xie)振點和升壓均為手(shou)(shou)動(dong),通(tong)過面板旋鈕(niu)完成。
系統參(can)(can)數設置(zhi)(zhi)是指(zhi)對設備部件參(can)(can)數的設置(zhi)(zhi)。
試驗(yan)參數(shu)設置是指對試驗(yan)過程參數(shu)的設置。
試(shi)驗(yan)(yan)模式選擇是(shi)指對試(shi)驗(yan)(yan)模式的選擇。
試驗結果查(cha)詢是指對試驗數據的查(cha)詢。
分(fen)壓器變比是指(zhi)對(dui)分(fen)壓器的分(fen)壓比設置。
電抗(kang)(kang)器電感(gan)是指(zhi)對電抗(kang)(kang)器電抗(kang)(kang)值的(de)設置。
激勵變變比是指對勵磁(ci)變壓器的變比設置。
設置(zhi)電壓(ya)是高壓(ya)試(shi)驗時的保護電壓(ya)設置(zhi)。
試驗(yan)電(dian)壓是高壓試驗(yan)時(shi)的試驗(yan)電(dian)壓。
加壓時間是施加試驗(yan)電壓的時間。
激(ji)勵(li)強度是(shi)指主(zhu)機電源(yuan)輸出的大小。
輸出(chu)電(dian)流是(shi)主(zhu)機電(dian)源的輸出(chu)電(dian)流。
頻率范(fan)(fan)圍(wei)是試驗的頻率范(fan)(fan)圍(wei)。
自動試(shi)驗(yan)模(mo)式是指試(shi)驗(yan)過程全部自動完成。
自(zi)動(dong)調諧(xie)模式是指自(zi)動(dong)尋找諧(xie)振點后(hou),手動(dong)加壓(ya)完成(cheng)試驗。
手動試驗(yan)模式全(quan)部(bu)由人(ren)工(gong)完(wan)成試驗(yan)過程。
未接地線主機電源為接地。
不能諧(xie)(xie)振(zhen)未能找到(dao)諧(xie)(xie)振(zhen)點。
輸出保護主機電源輸出電流大于整定電流。
試驗中(zhong)止指在升壓或加壓過程裝置自(zi)動保護。
設(she)備(bei)(bei)出廠參數(shu)設(she)置是廠家對設(she)備(bei)(bei)有關(guan)參數(shu)的(de)設(she)置。
確認鍵:確認當前操作。
返回(hui)鍵:返回(hui)上**菜單。
七、變頻(pin)電源技(ji)術參數:
1.額定輸出容量:15kvA;
2.儀(yi)器電源:220v±10% 50Hz;
功率電源:380v±10% 50Hz;
3.額定輸(shu)入電流:39.5A;
4.額(e)定輸出電(dian)(dian)壓(ya):0-340v可(ke)調(diao)、單相、輸出電(dian)(dian)壓(ya)不穩定度0.05%;
5.額定輸(shu)出(chu)電流(liu):44A;
6.頻率(lv)調節范(fan)圍:25~320Hz;
7.額定容量下連續運行為規定工作時(shi)間(jian)下*高溫升≤60K;
8.顯示以(yi)下(xia)參數:
a.經變頻輸出的頻率(lv)、電壓、電流;
b.過(guo)壓(ya)保(bao)(bao)護(hu)電壓(ya)值(zhi),并可任(ren)意整定(ding),當成套裝置的(de)輸出(chu)電壓(ya)值(zhi)達到保(bao)(bao)護(hu)整定(ding)時,可自動切除成套裝置;
c.過流(liu)保護:當調頻電源的輸出電流(liu)達到保護整定值時,可自動切除成套裝置(zhi);
d.擊(ji)穿保(bao)護(hu):當高壓側(ce)發生對(dui)地閃(shan)絡時,可自動切除(chu)成(cheng)套(tao)裝(zhuang)(zhuang)置(zhi),裝(zhuang)(zhuang)置(zhi)帶(dai)有隔離裝(zhuang)(zhuang)置(zhi),可確保(bao)設備和人身不(bu)受損害;
e.具有全電壓輸出保護,在(zai)調(diao)壓過程(cheng)中(zhong),一旦調(diao)壓失控(kong),調(diao)頻電源立即閉鎖;
9.可實現(xian)以下操作(zuo):
a.頻率(lv)(lv)的調(diao)節,上(shang)升(sheng)和下降頻率(lv)(lv)調(diao)節分粗調(diao)和細調(diao)兩種,并可(ke)自動(dong)尋找(zhao)試驗諧振點(dian),保證(zheng)諧振頻率(lv)(lv)在整(zheng)個試驗過(guo)程中不發生(sheng)漂移;
b.帶(dai)有設(she)(she)置電壓、設(she)(she)置時間,電壓自動(dong)上升到設(she)(she)置值而(er)停止(zhi)并(bing)自動(dong)計時;
c.帶有各種保護(hu)功(gong)能的整定(ding)按(an)鈕(niu),可在面(mian)板上對各種保護(hu)值進(jin)行(xing)整定(ding);
d.帶有手(shou)動試驗功(gong)能(neng)和自動試驗功(gong)能(neng);
e.帶有試(shi)驗數據打印功(gong)能。
八(ba)、勵磁變壓器技術參數(shu):
1.結構(gou)形式:干式;
2.額定容量:15kVA;
3.輸入(ru)電(dian)壓:0~340V;
4.輸出電(dian)壓:四(si)組(zu)并(bing)聯3.75KV;四(si)組(zu)串聯15KV;二串二并(bing)7.5KV;
5.輸出電流:四組并聯(lian)4A;四組串聯(lian)1A;二串二并2A;
6.工作頻率范圍(wei):30~300Hz;
勵磁(ci)變(bian)壓器(qi)的接線端(duan)子,如圖所示:
1.輸出端尾—與接地(di)端連接。
2.輸出端(duan)頭(tou)—與電抗器連(lian)接。
3.接(jie)地端—與變(bian)頻電(dian)源、分壓器及(ji)被試品(pin)共同接(jie)地。
4.輸入(ru)端—接調頻電(dian)源功率輸出端。
九、諧振電(dian)抗器技術參數:
額定容(rong)量:55KVA;
額定電壓(ya):55kV;
額定電流:1.5A;
電(dian) 感 量(liang):160H;
品質因數:Q≥30
采用(yong)環氧干式。
7.接線端了如圖所示:
a.高壓側接(jie)線端子(zi)—與被試(shi)品高壓端連接(jie)。
b.低壓側接線端子—與勵磁變(bian)輸(shu)出端連接。
c.多臺電抗器串聯時上節的低壓(ya)側與(yu)下(xia)節高壓(ya)側連(lian)接(jie)。諧振電抗器采用多臺串聯或并聯的連(lian)接(jie)方式(shi)。
8.額定(ding)容量下(xia)連續運(yun)行為規定(ding)工作(zuo)時間下(xia),電抗(kang)器對空氣(qi)的(de)溫(wen)升不大于60K;
9.性能及特點:電(dian)抗(kang)器設計干式(shi)、環(huan)氧(yang)(yang)澆(jiao)鑄,電(dian)抗(kang)器可(ke)以自由方便疊裝。環(huan)氧(yang)(yang)樹脂絕緣筒外(wai)殼,具有足(zu)夠的(de)電(dian)氣、機械強度,必要的(de)散熱能力(li)以及油熱脹(zhang)冷縮的(de)裕度。外(wai)殼上下蓋板(ban),顏色(se)為橘紅色(se)。
十、電(dian)容分(fen)壓(ya)器技術參數:
額定電壓:200kV;
工作頻率:30~300Hz;
分壓比:2000:1;
分(fen)壓比誤差:1%;
電(dian)容分壓器接線端子如圖所示:
高(gao)壓端(duan)—與電抗(kang)器高(gao)壓側(ce)及被(bei)試品高(gao)壓側(ce)相連。
測(ce)量(liang)插座(zuo)—采(cai)用專配的測(ce)量(liang)電纜與控制(zhi)箱背(bei)板測(ce)量(liang)輸入端連接。
接(jie)(jie)地(di)端—采用專配接(jie)(jie)地(di)線按(an)接(jie)(jie)線圖(tu)指(zhi)示接(jie)(jie)地(di)。
4.性能及特點:
a.額定電壓下可連續(xu)運行2小(xiao)時。
b.在30~300Hz范圍內(nei),其精度(du)和穩定度(du)保(bao)持不變。
c.在20℃溫度(du)下電(dian)容分壓器介(jie)質損耗(hao)值≤0.0025
d.電容分壓器配有(you)支撐底架,具有(you)足夠的(de)穩定性(xing)。
e.電壓測(ce)量通(tong)過專用測(ce)試引(yin)線引(yin)至調頻電源進行測(ce)量。
試(shi)驗接(jie)線(xian)圖:
110kv主變、GIS試驗(yan)接線
35kv電(dian)纜試驗接(jie)線圖(tu)
10kv電纜試驗接線(xian)圖
十二、設備保存和維(wei)護(hu)
1、存放于干燥、清潔場(chang)地,防止(zhi)雨水、灰塵(chen)進入部件內部;
2、如(ru)若長(chang)期不(bu)使(shi)用,正常天氣至少(shao)2個月(yue)應通(tong)電(dian)一次時間(jian)不(bu)少(shao)于半小時,雨季(ji)及潮(chao)濕(shi)期應每(mei)隔一個月(yue)通(tong)電(dian)一次,通(tong)電(dian)時間(jian)半小時,以驅(qu)除(chu)設備內的潮(chao)氣防止電(dian)子元器件的銹蝕,影響正常使(shi)用。
3、定期檢查裝(zhuang)置(zhi)各(ge)部件,確保各(ge)接頭緊(jin)固(gu)無松動(dong);
4、更換打印紙(zhi),機器采用(yong)熱(re)敏打印紙(zhi)并且是(shi)前(qian)換紙(zhi)式(shi)當需要換紙(zhi)時只要按(an)POST鍵鈕打印紙(zhi)艙(cang)門就會打開(kai)可(ke)以將(jiang)新打印紙(zhi)裝(zhuang)入(ru);
十(shi)三、常見故障排除
故障現(xian)象
|
發 生 原 因
|
排 除(chu) 方 法(fa)
|
找不到(dao)諧振點
|
接線有誤。
輸出開關(guan)未開,;
3、做GIS時(shi)PT二次回(hui)路未打開;
4、試品Q值太低;
5、起(qi)始激勵功率太(tai)低;
6、試驗回路有短路現象;
7、找(zhao)頻范(fan)圍不對(dui)。
|
退出試驗狀態(tai),合上輸(shu)出開(kai)關,檢查接線(xian);打開(kai)PT二次回路;
調高起始(shi)功率(∠30%);
用兆(zhao)歐(ou)表測量試(shi)品(pin)絕緣
重新設置找頻(pin)范圍
|
諧振后,電壓升不上去
|
1、試品Q值太低;
2、激勵電壓不夠(gou);
3、電抗器底部有鐵(tie)磁(ci)物體(ti);
4、3次諧波諧振(zhen)。
|
檢(jian)查試(shi)品;
改變激(ji)勵變壓(ya)(ya)器繞組接法(fa),提(ti)高勵磁電(dian)壓(ya)(ya)
絕緣筒(tong)架高電抗器或(huo)離開鐵磁物體。
|
主機自動復位
|
供電(dian)電(dian)源容(rong)量(liang)不夠;
電源引線(xian)(xian)過(guo)(guo)長(chang)或線(xian)(xian)徑(jing)過(guo)(guo)小;
接(jie)頭處接(jie)觸**;
供電電壓波動;
按(an)鍵死(si)接觸。
|
增加供電電源容量;
換較粗導線(xian),減小導線(xian)長度;
檢查(cha)接頭;
減小(xiao)供電電壓波(bo)動。
|
開機后(hou)線路跳閘
|
線路漏電保護(hu)器較為敏感;
空(kong)氣(qi)開(kai)關容量不夠。
|
跨過(guo)漏(lou)電保護(hu)器或空氣(qi)開關(guan)的(de)接(jie)線;
改換較大(da)容量(liang)的空氣開關。
|
電壓跌(die)落
|
試品放電或擊穿
|
檢查試品
|
輸(shu)出(chu)短路(lu)
|
電流(liu)超過本(ben)機限流(liu)值。
|
檢查接線和試(shi)品(pin)。
|
試品電(dian)壓(ya)不(bu)準
|
分壓比設(she)置錯誤(wu)或分壓器信號(hao)傳輸有問題。
|
重設分壓比或檢(jian)查(cha)分壓器接線(xian)。
|
電壓閃變(bian)
|
試(shi)驗電壓劇烈波(bo)動(dong),變化率超(chao)過本機限定值。
|
檢查供(gong)電電源電壓穩定性(xing)或試品(pin)參數的(de)變化。
|
回路無電流
|
|
檢(jian)查接線和試品(pin)。
|
未接好(hao)地(di)線
|
|
檢查接(jie)地(di)線和地(di)樁,按說明書要求連接(jie)。
|
試(shi)品過電壓
|
手動升壓(ya)太快或失(shi)控(kong)。
|
改(gai)變調壓(ya)步(bu)距或改(gai)用自動(dong)升(sheng)壓(ya) 。
|
系統不諧振
|
接(jie)線有誤或試品(pin)Q值太低。
|
檢(jian)查接線(xian)和試品(pin)
|
十四、常(chang)用設備(bei)資料參考
交聯聚乙(yi)烯電(dian)纜單(dan)位(wei)長度電(dian)容量
電纜導體截面(mian)積(平方(fang)毫米)
|
電(dian) 容 (μ/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
1×35
|
0.212
|
0.173
|
0.152
|
|
|
1×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
1×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
1×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
1×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
1×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
1×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
1×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
1×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
1×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
1×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
1×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
2、交聯聚(ju)乙烯電(dian)纜(lan)單位長度電(dian)容量
電纜導(dao)體截(jie)面積(平方毫米(mi))
|
電 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
3×35
|
0.212
|
0.173
|
0.152
|
|
|
3×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
3×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
3×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
3×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
3×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
3×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
3×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
3×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
3×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
3×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
3×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
3、交聯聚乙烯電纜單位(wei)長度電容量
電纜導體(ti)截(jie)面積(平方毫(hao)米)
|
電 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
64/110kV
|
128/220kV
|
3×240
|
0.129
|
|
3×300
|
0.139
|
|
3×400
|
0.156
|
0.118
|
3×500
|
0.169
|
0.124
|
3×630
|
0.188
|
0.138
|
3×800
|
0.214
|
0.155
|
3×1000
|
0.231
|
0.172
|
3×1200
|
0.242
|
0.179
|
3×1400
|
0.259
|
0.190
|
3×1600
|
0.273
|
0.198
|
3×1800
|
0.284
|
0.297
|
3×2000
|
0.296
|
0.215
|
3×2200
|
|
0.221
|
3×2500
|
|
0.232
|
4、60kV級全絕緣變壓器的(de)電容(rong)(pF)
類(lei) 型
|
變 壓 器 容 量 kVA
|
630
|
2000
|
3150
|
6300
|
8000
|
1600
|
高壓-地
|
2700
|
4100
|
4600
|
5900
|
7000
|
8200
|
低壓-地
|
4200
|
6600
|
7900
|
10000
|
11000
|
15300
|
對于(yu)表中(zhong)沒有的產(chan)(chan)品(pin)(pin),可根據表中(zhong)的上(shang)、下容量(liang)近似地(di)估算。同容量(liang)的雙繞組(zu)變壓器,其繞組(zu)電容要(yao)比三繞組(zu)產(chan)(chan)品(pin)(pin)小。
5、110kV級中性點分(fen)級絕緣變壓器(qi)的(de)電(dian)容(pF)
類 型
|
變 壓 器 容 量(liang)kVA
|
50000
|
31500
|
20000
|
10000
|
5600
|
高壓-中壓、低壓、地
|
14200
|
11400
|
8700
|
6150
|
4200
|
中壓-高壓、低(di)壓、地
|
24800
|
11800
|
13200
|
9600
|
-
|
低壓-高壓、中壓、地
|
19300
|
19300
|
12000
|
9400
|
6800
|
6、220kV級中性點非全(quan)級絕(jue)緣部分變壓器(qi)的電容(pF)
試(shi) 品(pin) 型 號
|
SEPSL-63000
|
SSPSL-120000
|
SSPSL-240000
|
類 型
|
高(gao)壓-中壓、低壓及地(di)
|
12100
|
13500
|
17050
|
中壓(ya)-高壓(ya)、低壓(ya)及地
|
18500
|
19700
|
23260
|
低壓-高壓、中(zhong)壓及(ji)地
|
18200
|
23600
|
29940
|
試 品 型 號
|
SFPL-240000
|
SFP-360000
|
SFPSZL-120000
|
類 型(xing)
|
高壓(ya)(ya)-中壓(ya)(ya)、低(di)壓(ya)(ya)及(ji)地
|
32230
|
33910
|
38020
|
中壓(ya)-高壓(ya)、低(di)壓(ya)及地(di)
|
-
|
-
|
23260
|
低壓(ya)(ya)-高壓(ya)(ya)、中壓(ya)(ya)及地
|
22470
|
23790
|
22160
|
7、油(you)浸式電力(li)變壓器交流試驗電壓
額定電(dian)壓
(k V)
|
*高工作
電壓(ya)(k V)
|
線(xian)端(duan)交流試(shi)驗電壓值(kV)
|
中性點交流(liu)試驗電壓值(zhi)(kV)
|
全部更換(huan)繞(rao)組
|
部分(fen)更換繞(rao)組(zu)或交(jiao)接
|
全(quan)部(bu)更換(huan)繞組
|
部分更換繞組或交接(jie)
|
<1
|
≤1
|
3
|
2.5
|
3
|
2.5
|
3
|
3.5
|
18
|
15
|
18
|
15
|
6
|
6.9
|
25
|
21
|
25
|
21
|
10
|
11.5
|
35
|
30
|
35
|
30
|
15
|
17.5
|
45
|
38
|
45
|
38
|
20
|
23.0
|
55
|
47
|
55
|
47
|
35
|
40.5
|
85
|
72
|
85
|
72
|
110
|
126.0
|
200
|
170(195)
|
95
|
80
|
220
|
252.0
|
360
|
306
|
85
|
72
|
395
|
336
|
(200)
|
(170)
|
500
|
550.0
|
630
|
536
|
85
|
72
|
680
|
578
|
140
|
120
|
8、部分型號發(fa)電(dian)機定子繞組的單(dan)相對地電(dian)容量(liang)
類(lei)別
|
發 電(dian) 機
|
型號
|
生(sheng)產廠家
|
額定容量(MW)
|
額定電(dian)壓(kV)
|
相(xiang)電容(rong)(mF)
|
火
力
發
電(dian)
機
|
QFS-125-2
|
上海電(dian)機廠(chang)
|
125
|
13.8
|
0.08-0.12
|
QFSN-200-2
|
哈爾濱(bin)電(dian)機廠
|
200
|
15.75
|
0.19-0.21
|
QFQS-200-2
|
東(dong)方(fang)電(dian)機廠(chang)
|
200
|
15.75
|
0.1928-0.21
|
QFQS-200-2
|
北京(jing)重型電機(ji)廠
|
200
|
15.75
|
0.18-0.19
|
QFS-300-2
|
上海電機廠
|
300
|
18.0
|
0.16-0.20
|
QFSN-300-2
|
上海(hai)電機廠
|
300
|
18.0
|
0.18-0.20
|
ATB-2
|
美(mei)國GE公司
|
352
|
23.0
|
0.268(設計值)
|
TBB-320-2
|
(前蘇聯)
|
320
|
20.0
|
0.31
|
2-105×234
|
美(mei)國西屋(wu)公(gong)司
|
600
|
20.0
|
0.2(工(gong)廠試(shi)驗值)
|
50WT23E-138
|
ABB
|
600
|
22.0
|
0.253(設計值)
|
水 發(fa)
力 電
機
|
|
|
72.5 - 85
|
10.5
|
0.694
|
|
|
300
|
15.75
|
1.7-2.5
|
|
|
400
|
18.0
|
2-2.5
|
9、同步(bu)發電(dian)機定子繞(rao)組交流試驗電(dian)壓
1
|
全部(bu)更換定子繞組并修(xiu)好后的試驗電壓
|
容量kW或kVA
|
小于10000
|
10000及以上(shang)
|
額定電壓Un (V)
|
36以上(shang)
|
6000以下
|
6000~18000
|
18000以上
|
試驗電壓(ya)V
|
2Un+1000但*低為(wei)1500
|
2.5Un
|
2Un
+3000
|
按專門協議(yi)
|
2
|
大修前或局(ju)部更換(huan)定子(zi)繞組(zu)并修好后的(de)試驗(yan)電壓(ya)
|
運行20年(nian)及以下者(zhe)
|
1.5 Un
|
運行20年(nian)以上(shang)與架空(kong)線路(lu)直接(jie)連接(jie)者
|
1.5 Un
|
運行20年以上(shang)不與(yu)架空線路直接連接者(zhe)
|
(1.3~1.5)Un
|
十五、設(she)備成套性:
變頻電源 1臺
勵磁變壓器 1臺(tai)
電抗器 4臺
電容分壓(ya)器 1臺
附件及測試線(xian) 1套
支架 15KV 1只(zhi)
均壓(ya)罩 200KV 2只
絕緣底板 2塊
一(yi)、產(chan)品概述
YDQC系列(lie)輕型(xing)交直(zhi)流高(gao)壓(ya)(ya)試(shi)驗(yan)(yan)變壓(ya)(ya)器(qi)是(shi)在同類產(chan)品YDJ(G)型(xing)高(gao)壓(ya)(ya)試(shi)驗(yan)(yan)變壓(ya)(ya)器(qi)的基(ji)礎上,按試(shi)驗(yan)(yan)變壓(ya)(ya)器(qi)國家標準(zhun)ZBK41006—89要求(qiu),經改進后生產(chan)的一種新型(xing)產(chan)品,本系列(lie)產(chan)品具有體積小、重量輕、結構(gou)緊(jin)湊、功能齊全(quan)、使用(yong)方(fang)便等特點。實(shi)用(yong)于電(dian)力、工(gong)礦(kuang)、科(ke)研等部門,對各種高(gao)壓(ya)(ya)電(dian)氣設備、電(dian)氣元件、絕緣材料進行工(gong)頻耐壓(ya)(ya)試(shi)驗(yan)(yan)和直(zhi)流泄漏試(shi)驗(yan)(yan),是(shi)高(gao)壓(ya)(ya)試(shi)驗(yan)(yan)中(zhong)必不可少的儀器(qi)。
二、產品結構(gou)
YDQC系列(lie)輕型高(gao)壓試驗變壓器鐵(tie)芯為單框(kuang)式(shi)。線(xian)圈采用同(tong)芯圓筒多(duo)層塔式(shi)結構,初級(ji)低壓繞(rao)組(zu)(zu)繞(rao)在鐵(tie)芯上,次級(ji)高(gao)壓繞(rao)組(zu)(zu)繞(rao)在低壓繞(rao)組(zu)(zu)外(wai)側,這種同(tong)軸布置減(jian)少了繞(rao)組(zu)(zu)間的藕合損耗。高(gao)壓硅堆(dui)用特(te)殊工(gong)藝封裝在套(tao)管內,產品的外(wai)殼制(zhi)成與器芯配合較佳的八角形(xing)結構,整(zheng)體外(wai)型美觀大方。其(qi)內外(wai)部結構見圖1。
1-均壓(ya)球;2-硅堆(dui)短路桿(gan);3-高(gao)壓(ya)套管;4-油(you)閥;5-殼(ke)體;6、7-調(diao)整(zheng)電壓(ya)輸(shu)(shu)入a、x端(duan)(duan)子(zi);8、9-儀(yi)(yi)表測量(liang)E、F端(duan)(duan)子(zi);10-高(gao)壓(ya)尾X端(duan)(duan)子(zi);11-變(bian)壓(ya)器外(wai)殼(ke)接地端(duan)(duan);12-高(gao)壓(ya)輸(shu)(shu)出A端(duan)(duan)子(zi);13-高(gao)壓(ya)整(zheng)流硅堆(dui);14-內部均壓(ya)環;15-變(bian)壓(ya)器鐵芯;16-初級低(di)壓(ya)繞(rao)組(zu);17-測量(liang)儀(yi)(yi)表繞(rao)組(zu);18-二次級高(gao)壓(ya)繞(rao)組(zu);19-變(bian)壓(ya)器油(you)。
三、工(gong)作原理(li)
YDQC系列輕型高壓(ya)(ya)(ya)(ya)(ya)試驗(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)為單(dan)相(xiang)變(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi),聯結組標號II。單(dan)臺高壓(ya)(ya)(ya)(ya)(ya)試驗(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)的工(gong)作過程,用交(jiao)流220V(10KVA以上(shang)為380V)電(dian)壓(ya)(ya)(ya)(ya)(ya)接入電(dian)源(yuan)控制(zhi)箱(臺),經(jing)電(dian)源(yuan)控制(zhi)箱(臺)內自藕調(diao)壓(ya)(ya)(ya)(ya)(ya)器(qi)(50KVA以上(shang)調(diao)壓(ya)(ya)(ya)(ya)(ya)器(qi)外附)調(diao)節0~200V(10KVA以上(shang)0~400V)電(dian)壓(ya)(ya)(ya)(ya)(ya)至試驗(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)的初級繞組,根據電(dian)磁感應(ying)原理(li),在試驗(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)高壓(ya)(ya)(ya)(ya)(ya)繞組可獲得(de)試驗(yan)所需的高電(dian)壓(ya)(ya)(ya)(ya)(ya)。其工(gong)作原理(li)圖見圖2所示。
1、單臺YDQC高壓(ya)試驗變壓(ya)器工作原理示意圖
在試驗變(bian)壓(ya)器中:a、x為低(di)壓(ya)輸入(ru)端(duan);A、X 為高壓(ya)輸出端(duan);E、F為儀(yi)表測量端(duan)。
2、單臺交直流兩用型高壓試驗變壓器工作原理見圖3。圖中所示:高壓套管內裝有高壓硅堆,串接在高壓回路中作高壓整流,以獲得直流高電壓。當用一短路桿將高壓硅堆短接時,可獲得交流高電壓,其狀態為交流輸出;反之在抽出短路桿時,其狀態為直流輸出。
3、三臺高壓試驗變壓器串激獲得更高電壓原理見圖4,串激高壓試驗變壓器有很大的優越性,因為整個試驗裝置由多個單臺串激式試驗變壓器組成,單臺試驗變壓器有著體積小、重量輕、便于運輸的特點,它既可以串接成高出幾倍的單臺試驗變壓器輸出電壓組合使用,又可以分開單獨使用。整套試驗裝置投資小、經濟實惠。圖3所示:在三臺串激式試驗變壓器串激使用中,單臺試驗變壓器B1、B2、B3的輸出電壓都是U,**、二級的試驗變壓器內部都有一個激磁繞組,分別為A1、C1 和A2、C2。當控制電壓加在第**試驗變壓器B1的初級繞組a1、x1上,激磁繞組A1、C1給予試驗變壓器B2初級繞組供電,**級試驗變壓器B2的激磁繞組A2、C2給試驗變壓器B3的初級繞組供電。由于第**試驗變壓器B1的高壓尾及殼體接地,**、三級的試驗變壓器B2和B3對地有絕緣支架的隔離,這樣試驗變壓器B1、B2、B3對地輸出電壓分別為1U、2U、3U。
B1、B2、B3- 串(chuan)激式高壓變壓器;1U、2U、3U-各(ge)級對(dui)地電壓;
PV- 高壓示值表(KV); ZJ1、ZJ2-絕緣(yuan)支架。
四、使用方法(fa)及注(zhu)意事項(xiang)
1、YDQC高(gao)壓(ya)(ya)(ya)(ya)試驗變壓(ya)(ya)(ya)(ya)器做(zuo)工頻耐壓(ya)(ya)(ya)(ya)試驗使用接線方法見圖5。做(zuo)工頻耐壓(ya)(ya)(ya)(ya)試驗前,先根據試驗變壓(ya)(ya)(ya)(ya)器的(de)(de)(de)額定容量選擇好(hao)限(xian)流(liu)電(dian)阻(zu)(zu),(水電(dian)阻(zu)(zu))的(de)(de)(de)阻(zu)(zu)值,再根據被試品需加(jia)的(de)(de)(de)高(gao)壓(ya)(ya)(ya)(ya)電(dian)壓(ya)(ya)(ya)(ya)值調整好(hao)放(fang)電(dian)球隙的(de)(de)(de)球間距(ju),為了提(ti)高(gao)對(dui)被試品施(shi)加(jia)電(dian)壓(ya)(ya)(ya)(ya)的(de)(de)(de)測(ce)量精度,應在高(gao)壓(ya)(ya)(ya)(ya)側接入FRC阻(zu)(zu)容分壓(ya)(ya)(ya)(ya)器來(lai)測(ce)量電(dian)壓(ya)(ya)(ya)(ya)。
R1、R2- 限流電阻; Qx- 放電球隙; Zx- 被試品(pin);
FRC- 阻容分壓器; V- 分壓器高壓表。
按照圖4、結合圖2所進行的工頻耐壓試驗接好工作線路,試驗變壓器的高壓繞阻的X端(高壓尾)、儀表測量繞組的F端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
用三臺試驗變壓器串激做工頻耐壓試驗時、**、三級試驗變壓器的初級繞組X端,儀表測量繞組的F端,以及高壓繞組的X端(高壓尾)均接本級試驗變壓器的外殼,**、三級試驗變壓器的主體必須放置在絕緣支架上。除第**以外、**、三級試驗變壓器的主體不要接地線。其接線方式見圖3所示。
接電源前,電源控制箱(臺)的調壓器必須調到零位。接通電源后,綠色指示燈亮,按一下啟動按鈕,紅色指示燈亮,表示試驗變壓器已接通控制電源,開始升壓。
從零位開始按順時針方向勻速旋轉調壓器手輪升壓。(升壓方式有:快速升壓法,即20S逐級升壓法,慢速升壓法,即60S逐級升壓法,極慢速升壓法供選用)電壓從零開始按選定的升壓速度升到您所需額定試驗電壓的75%后,再以每秒2%額定試驗電壓的速度升到您所需試驗電壓,并密切注意測量儀表的指示以及被試品的情況,被試品施加電壓的時間到后。應在數秒內勻速將調壓器返回,高壓降至1/3試驗電壓以下,按一下停止按鈕,高壓、低壓輸出停止,然后切斷電源線,試驗完畢。
工頻耐壓試(shi)驗操作(zuo)過程(cheng)注意事(shi)項
1、試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
2、被試品主要部位應**干凈,保持**干燥,以免損壞被試品和帶來試驗數值的誤差。
3、對大型設備的試驗,一般都應先進行試驗變壓器的空升試驗,即不接試品時升壓至試驗電壓,以便校對好儀表的指示精度,調整好放電球隙的球間距。
4、做耐壓試驗時升壓速度不能過快,并防止突然加壓,例如調壓器不在零位的突然合閘,也不能突然斷電,一般應在調壓器降至零位時分閘。
5、在升壓或耐壓試驗過程中,如發現下列不正常情況,1 電壓、電流表指針擺動很大,2 被試品發出不正常響聲,3 發現絕緣有燒焦或冒煙現象,應立即降壓,切斷電源,停止試驗并查明原因。
6、使用本產品做高壓試驗時,除熟悉本說明書外,還必須嚴格執行國家有關標準和操作規程。
2、YDQ交(jiao)(jiao)直流(liu)(liu)兩用高(gao)(gao)壓(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)器做直流(liu)(liu)耐壓(ya)(ya)和泄(xie)漏試(shi)(shi)(shi)驗(yan)(yan)使用接(jie)線方法見圖5。由于是交(jiao)(jiao)直流(liu)(liu)兩用高(gao)(gao)壓(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)器,應把(ba)高(gao)(gao)壓(ya)(ya)硅堆短(duan)路(lu)桿從套管中抽出,使試(shi)(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)器為直流(liu)(liu)輸出狀態。做直流(liu)(liu)泄(xie)漏試(shi)(shi)(shi)驗(yan)(yan)前,先根(gen)(gen)據泄(xie)漏試(shi)(shi)(shi)驗(yan)(yan)中輸出端斷(duan)路(lu)電(dian)流(liu)(liu)不超(chao)過高(gao)(gao)壓(ya)(ya)硅堆的(de)*大整(zheng)流(liu)(liu)為宜,選(xuan)擇(ze)好限流(liu)(liu)電(dian)阻(zu)(水電(dian)阻(zu))的(de)阻(zu)值,再(zai)根(gen)(gen)據被試(shi)(shi)(shi)品對直流(liu)(liu)高(gao)(gao)壓(ya)(ya)波形的(de)要求(qiu)選(xuan)擇(ze)好高(gao)(gao)壓(ya)(ya)濾波電(dian)容(rong)的(de)電(dian)容(rong)值。為了提高(gao)(gao)對被試(shi)(shi)(shi)品施(shi)加電(dian)壓(ya)(ya)的(de)測量精度,應在高(gao)(gao)壓(ya)(ya)側接(jie)入FRC阻(zu)容(rong)分壓(ya)(ya)器來測量電(dian)壓(ya)(ya)。
R- 限流(liu)電阻; C- 高壓濾波電容; Zx- 被試品(pin); G- 硅堆短路桿;
FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高壓整流硅堆。
按照圖5、結合圖3所進行的直流泄漏試驗接好工作線路。試驗變壓器的高壓繞組的X端(高壓尾)、儀表測量繞組的F 端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
接(jie)電(dian)源(yuan)前、電(dian)源(yuan)控(kong)制箱(臺)的(de)調壓器必須調到零位。接(jie)通(tong)電(dian)源(yuan)后,綠色(se)指示(shi)(shi)燈(deng)亮,按一下(xia)啟動按鈕,紅色(se)指示(shi)(shi)燈(deng)亮,表(biao)示(shi)(shi)試(shi)驗變壓器已接(jie)通(tong)控(kong)制電(dian)源(yuan),開(kai)始升壓。
從零位開始按(an)順(shun)時針方(fang)向勻速(su)(su)(su)旋轉調壓(ya)(ya)(ya)(ya)(ya)(ya)器手輪升(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)。(升(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)方(fang)式有:快速(su)(su)(su)升(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa)即20S逐級升(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa);慢速(su)(su)(su)升(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa),即60S逐級升(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa);級慢速(su)(su)(su)升(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa)供(gong)選用)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)從零開始按(an)選定(ding)的升(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)速(su)(su)(su)度升(sheng)到您所需(xu)額(e)定(ding)試(shi)驗(yan)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)或額(e)定(ding)直流(liu)電(dian)(dian)(dian)流(liu)下(xia)的參考(kao)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)。試(shi)驗(yan)中應嚴密注意(yi)直流(liu)高壓(ya)(ya)(ya)(ya)(ya)(ya)表、泄漏(lou)電(dian)(dian)(dian)流(liu)表指示以及(ji)被試(shi)品的情況(kuang)。試(shi)驗(yan)完(wan)畢(bi)后,應訊(xun)速(su)(su)(su)均勻將高壓(ya)(ya)(ya)(ya)(ya)(ya)降至零位,按(an)一下(xia)停止按(an)鈕,高壓(ya)(ya)(ya)(ya)(ya)(ya)、低壓(ya)(ya)(ya)(ya)(ya)(ya)輸出停止,然后切斷電(dian)(dian)(dian)源。此時應用直流(liu)高壓(ya)(ya)(ya)(ya)(ya)(ya)放**給(gei)被試(shi)品及(ji)試(shi)驗(yan)裝置(zhi)本身(shen)充分放電(dian)(dian)(dian)。
直流(liu)泄漏(lou)試驗操作過(guo)程注(zhu)意(yi)事項
(1)試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
(2)被試品做試驗前,應拆除所有對外連線,并充分放電,主要部位應**干凈,保持**干燥,以免損壞被試品及帶來試驗數值的誤差。
(3)對于大容量試品(電容器、超長電纜等)試驗時應緩慢升壓,防止被試品的充電電流過大而燒壞微安表,必要時應分級加壓分別讀取各電壓下微安表的穩定讀數。
(4)試驗過程中,應嚴密監視被試品、微安表及試驗裝置等,一旦發生閃爍、擊穿等現象應立即降壓,切斷電源,并查明原因。
五、配套(tao)選(xuan)購產品
下列產品僅供選擇,購買時需另行計價。
1.KZX系列電源控制箱 容量:1KVA-5KVA、輸入電壓:220V
2.KZT系列電源控制臺 容量:10KVA~300KVA輸入電壓:220V或380V
3.數字微安表:SWB-II
4.高壓濾波電容: 0.01MF、40 ~ 100KV
5.高壓直流放**: FBR— 70、140、210KV
6.放電球隙: Q—50、100、150、200、250、500
7.標準試油杯: 400ml
8.折疊式手推車: 150、300型
9.絕緣支架: 50、100、200、300、400KV
10.阻容分壓器: FRC —50、100、150、200KV
11.高壓硅堆: 2DL—150、300、450KV
12.水 電 阻: 50、100
六、主要試驗(yan)設備的選擇
1、試驗變壓器
其高壓側額定電壓應不小于被試品的*高試驗電壓,額定電流不小于被試品的*大電容電流。被試品的電容電流和試驗變壓器所需容量計算式為:
被試品電容量Cx可由交流(liu)電橋測出。常用的被試品電容量按表(biao)1選(xuan)取。
幾種常用被試品的電(dian)容量(liang)(pF) 表1
2、調壓設(she)備
(1)自藕調壓器。其調壓范圍廣、功率損耗小、波形畸變小、選擇這種調壓方式為*好。自藕調壓器的容量按0.75 ~ 1倍的試驗變壓器的容量選擇,適用于容量為100KVA以下的試驗變壓器的調壓。
(2)感應調壓器。其調壓范圍大,波形畸形小、但結構復雜、價格較貴,當試驗變壓器的容量較大時(如100KVA以上)使用。
3、限流電阻
限流電阻的作用是,當被試品擊穿時,限制斷路電流,從而保護試驗變壓器,防止故障的擴大。其數值以*高試驗電壓為準,按0.5 ~ 1 Ω / V(有效值)選擇,限流電阻可用水電阻。注意水不能充滿玻璃管,應留有余地,以防爆裂。
4、放電球隙
放電球隙的布置方式有垂直和水平兩種,球隙間距S和球的直徑D的關系應保護在0.05D ≤S ≤0.5D范圍內,球隙上的水電阻阻值一般按0.1 ~ 1Ω/V選取,設置放電球隙的目的是為了對重要的被試品起保護作用,可以將由于誤操作或被試品擊穿引起的過電壓限制在允許的范圍內。
七、試驗變壓器技術指(zhi)示
型號
|
容量
|
高壓(ya)電(dian)壓(ya)
|
高壓電流
|
低壓(ya)輸入(ru)
|
變比
|
溫升℃
|
(KVA)
|
(KV)
|
(mA)
|
電壓(V)
|
電(dian)流(A)
|
高/儀(yi)
|
30分鐘
|
YDQC-1.5/50
|
1.5
|
50
|
30
|
200
|
7.5
|
500
|
10
|
YDQC-3/50
|
3
|
50
|
60
|
200
|
15
|
500
|
10
|
YDQC-5/50
|
5
|
50
|
100
|
200
|
25
|
500
|
10
|
YDQC-10/50
|
10
|
50
|
200
|
200
|
50
|
500
|
10
|
YDQC-15/50
|
15
|
50
|
300
|
200
|
75
|
500
|
10
|
YDQC-20/50
|
20
|
50
|
400
|
380
|
53
|
500
|
10
|
YDQC-30/50
|
30
|
50
|
600
|
380
|
79
|
500
|
10
|
YDQC-50/50
|
50
|
50
|
1000
|
380
|
12
|
500
|
10
|
YDQC-5/100
|
5
|
100
|
50
|
200
|
25
|
1000
|
10
|
YDQC-10/100
|
10
|
100
|
100
|
200
|
50
|
1000
|
10
|
YDQC-20/100
|
20
|
100
|
200
|
400
|
50
|
1000
|
10
|
YDQC-30/100
|
30
|
100
|
300
|
400
|
75
|
1000
|
10
|
YDQC-50/100
|
50
|
100
|
500
|
400
|
125
|
1000
|
10
|
YDQC-20/150
|
20
|
150
|
133
|
400
|
50
|
1500
|
10
|
YDQC-30/150
|
30
|
150
|
200
|
400
|
75
|
1500
|
10
|
YDQC-50/150
|
50
|
150
|
333
|
400
|
125
|
1500
|
10
|
YDQC-100/150
|
100
|
150
|
667
|
400
|
250
|
1500
|
10
|
YDQC-50/200
|
50
|
200
|
250
|
400
|
125
|
2000
|
10
|
YDQC-100/200
|
100
|
200
|
500
|
400
|
250
|
2000
|
10
|
YDQC-150/200
|
150
|
200
|
750
|
400
|
375
|
2000
|
10
|
YDQC-200/200
|
200
|
200
|
1000
|
400
|
500
|
2000
|
10
|
YDQC-300/200
|
300
|
200
|
1500
|
400
|
600
|
2000
|
10
|
YDQC-50/300
|
50
|
300
|
170
|
400
|
125
|
3000
|
10
|
YDQC-100/300
|
100
|
300
|
333
|
400
|
250
|
3000
|
10
|
YDQC-150/300
|
150
|
300
|
500
|
400
|
375
|
3000
|
10
|
YDQC-200/300
|
200
|
300
|
667
|
400
|
500
|
3000
|
10
|
YDQC-300/300
|
300
|
300
|
3000
|
500
|
600
|
3000
|
10
|
1、使用環境條件
環境溫度不高于+40℃、不低于—20℃;空氣相對濕度不大于90%;海拔高度不超過2000米;
2、工作電壓
電源控制箱(臺)輸入電壓為工頻220V或380V、相對誤差不超過±10%;(具體使用電壓根據用戶所定試驗變壓器規格選取)
八、隨貨文件
YDQC 系列試驗變壓器產品說明書 1份
產品出廠試驗報告 1份
產品合格證 1份
裝箱單 1份
一(yi)、概述(shu)
YDQ系列高(gao)壓(ya)(ya)(ya)試(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)器(qi)是(shi)(shi)根(gen)據《試(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)器(qi)》標(biao)準,在油浸(jin)式試(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)器(qi)的(de)(de)(de)基礎(chu)上而(er)設(she)計生產(chan)(chan)的(de)(de)(de)。SF6氣(qi)(qi)體(ti)具(ju)有(you)良好的(de)(de)(de)電氣(qi)(qi)絕(jue)(jue)緣性能(neng)及(ji)優(you)異的(de)(de)(de)滅弧性能(neng),其耐壓(ya)(ya)(ya)強(qiang)度(du)(du)為(wei)同一(yi)(yi)壓(ya)(ya)(ya)力下氮氣(qi)(qi)的(de)(de)(de)2.5倍,擊(ji)穿(chuan)電壓(ya)(ya)(ya)的(de)(de)(de)空氣(qi)(qi)的(de)(de)(de)2.5倍。在0.25MPa下與油的(de)(de)(de)擊(ji)穿(chuan)電壓(ya)(ya)(ya)相(xiang)等(deng),在0.45MPa壓(ya)(ya)(ya)力下是(shi)(shi)油的(de)(de)(de)擊(ji)穿(chuan)電壓(ya)(ya)(ya)的(de)(de)(de)2倍,是(shi)(shi)一(yi)(yi)種優(you)于油的(de)(de)(de)新一(yi)(yi)代(dai)(dai)超高(gao)壓(ya)(ya)(ya)絕(jue)(jue)緣介(jie)質(zhi)材料。該產(chan)(chan)品(pin)技(ji)術要求完全符(fu)合《ZBK-41006-89》標(biao)準,它(ta)是(shi)(shi)油浸(jin)式輕(qing)型試(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)器(qi)的(de)(de)(de)換代(dai)(dai)產(chan)(chan)品(pin)。該產(chan)(chan)品(pin)具(ju)有(you)體(ti)積小、重量輕(qing)、不受氣(qi)(qi)候變(bian)(bian)(bian)化影響(xiang)、電暈(yun)小、現場搬運無(wu)需靜(jing)止可(ke)使用,使用壽命長、免維修等(deng)特點。適用于電力系統、工礦(kuang)企業(ye)、科研部門(men)等(deng)對各種高(gao)壓(ya)(ya)(ya)電氣(qi)(qi)設(she)備、電氣(qi)(qi)元件(jian)、絕(jue)(jue)緣材料進(jin)行工頻或直流高(gao)壓(ya)(ya)(ya)下的(de)(de)(de)絕(jue)(jue)緣強(qiang)度(du)(du)試(shi)(shi)驗(yan)(yan)。
二、產品結(jie)構
YDQ系(xi)列高壓試驗變壓器采用單框(kuang)芯式鐵(tie)芯結(jie)構,初級(ji)繞組(zu)繞在(zai)鐵(tie)芯上,高壓繞組(zu)在(zai)外,這種(zhong)同(tong)軸布置減少了漏磁通(tong),因(yin)而增大(da)了繞組(zu)間的(de)耦合。產品(pin)的(de)外殼為圓柱灌式容器結(jie)構,能(neng)耐受0.8MPa以上壓力。其結(jie)構見(jian)圖1:
三(san)、工作原(yuan)理
YDQ系列高(gao)壓(ya)(ya)試驗(yan)變壓(ya)(ya)器(qi)為單相變壓(ya)(ya)器(qi),聯結組(zu)(zu)標(biao)號Ⅰ.Ⅰ. 用(yong)工頻220V(10kVA以上(shang)為380V)電(dian)(dian)源接入 (為本公司生產的試驗(yan)變壓(ya)(ya)器(qi)配(pei)套專用(yong)設備,詳細資(zi)料請見(jian)其具體使用(yong)說明書)系列操作(zuo)箱(xiang)(臺(tai)),經操作(zuo)箱(xiang)內自偶調壓(ya)(ya)器(qi)(50kVA以上(shang)調壓(ya)(ya)器(qi)外附)調節至(zhi)0~200V(或0~400V)電(dian)(dian)壓(ya)(ya)輸出至(zhi)YDQ試驗(yan)變壓(ya)(ya)器(qi)的初(chu)級繞組(zu)(zu),根據電(dian)(dian)磁(ci)感應原理,在試驗(yan)變壓(ya)(ya)器(qi)高(gao)壓(ya)(ya)繞組(zu)(zu)可獲(huo)得試驗(yan)所需(xu)的高(gao)電(dian)(dian)壓(ya)(ya)。
單臺YDQ系列交(jiao)直流(liu)(liu)高(gao)壓(ya)試驗(yan)變壓(ya)器的工作原理圖見圖3,圖中(zhong)高(gao)壓(ya)套管中(zhong)裝有高(gao)壓(ya)硅堆,串接(jie)在高(gao)壓(ya)回路(lu)中(zhong)作半波整流(liu)(liu),以(yi)獲得直流(liu)(liu)高(gao)電壓(ya)。當用一短路(lu)桿將高(gao)壓(ya)硅堆短接(jie)時,可獲得工頻高(gao)電壓(ya),作為交(jiao)流(liu)(liu)輸出狀態(tai);取(qu)消短路(lu)桿時,作為直流(liu)(liu)輸出狀態(tai)。
圖中:D—短路桿 VD—高壓硅(gui)堆(dui)
試驗(yan)變壓(ya)器(qi)高(gao)壓(ya)套(tao)管中的高(gao)壓(ya)硅(gui)堆(dui)未畫出,其原理與上圖相同。
三(san)臺(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)串級(ji)(ji)(ji)獲得更(geng)高(gao)電(dian)壓(ya)(ya)(ya)的(de)(de)(de)接(jie)(jie)線原(yuan)理(li)見圖(tu)4。串級(ji)(ji)(ji)高(gao)壓(ya)(ya)(ya)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)有(you)(you)很(hen)大的(de)(de)(de)優越性(xing),因為(wei)整個試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)裝(zhuang)置由幾(ji)臺(tai)單(dan)(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)組(zu)(zu)成,單(dan)(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)容量(liang)小、電(dian)壓(ya)(ya)(ya)低、重量(liang)輕,便于運輸和安裝(zhuang)。它既然可串接(jie)(jie)成高(gao)出(chu)幾(ji)倍(bei)的(de)(de)(de)單(dan)(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)輸出(chu)電(dian)壓(ya)(ya)(ya)組(zu)(zu)合使(shi)用,又可分開成幾(ji)套(tao)單(dan)(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)單(dan)(dan)(dan)獨使(shi)用。整套(tao)裝(zhuang)置投資小,經濟實惠。圖(tu)5中,在(zai)第**和**級(ji)(ji)(ji)的(de)(de)(de)每(mei)個單(dan)(dan)(dan)元試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)中都(dou)有(you)(you)一個勵(li)磁繞(rao)(rao)組(zu)(zu)A1、C1和A2、C2。在(zai)三(san)臺(tai)串級(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)基(ji)本原(yuan)理(li)中,低壓(ya)(ya)(ya)電(dian)源加(jia)在(zai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)Ⅰ的(de)(de)(de)初(chu)級(ji)(ji)(ji)繞(rao)(rao)組(zu)(zu)a1x1上,單(dan)(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)Ⅰ、Ⅱ、Ⅲ的(de)(de)(de)輸出(chu)電(dian)壓(ya)(ya)(ya)都(dou)是V。勵(li)磁繞(rao)(rao)組(zu)(zu)A1、C1給(gei)**級(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)Ⅱ的(de)(de)(de)初(chu)級(ji)(ji)(ji)繞(rao)(rao)組(zu)(zu)供(gong)電(dian);**級(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)Ⅱ的(de)(de)(de)勵(li)磁繞(rao)(rao)組(zu)(zu)A2、C2給(gei)第三(san)級(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)Ⅲ的(de)(de)(de)初(chu)級(ji)(ji)(ji)繞(rao)(rao)組(zu)(zu)供(gong)電(dian)。**級(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)Ⅱ和第三(san)級(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)Ⅲ的(de)(de)(de)箱(xiang)體(ti)分別(bie)處在(zai)對地為(wei)1V和2V的(de)(de)(de)高(gao)電(dian)位(wei)上,所以箱(xiang)體(ti)對地是絕緣的(de)(de)(de),試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)Ⅰ的(de)(de)(de)箱(xiang)體(ti)是接(jie)(jie)地的(de)(de)(de)。這樣第**、**級(ji)(ji)(ji)、第三(san)級(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)對地的(de)(de)(de)額(e)定輸出(chu)電(dian)壓(ya)(ya)(ya)分別(bie)為(wei)1V、2V、3V;其(qi)額(e)定容量(liang)分別(bie)為(wei)3P、2P、1P。
YDQ系列高壓(ya)(ya)試驗變壓(ya)(ya)器做被試品的工頻(pin)耐壓(ya)(ya)試驗使用接線(xian)原理圖(tu)見(jian)圖(tu)5。
圖中(zhong):R1—限流(liu)電阻 FRC—阻容分壓(ya)器(qi) RF—球間隙(xi)保護電阻 G—球間隙(xi) CX—被試品
注:高壓尾必須(xu)可(ke)靠接(jie)地
工頻耐壓(ya)(ya)試驗中限(xian)(xian)流電(dian)阻(zu)(zu)(zu)R1應(ying)根據(ju)試驗變壓(ya)(ya)器(qi)的(de)額定(ding)(ding)容量(liang)來選(xuan)擇。如高壓(ya)(ya)側額定(ding)(ding)輸(shu)(shu)出電(dian)流在100~300mA時(shi),可(ke)取0.5~1Ω/V(試驗電(dian)壓(ya)(ya));高壓(ya)(ya)側額定(ding)(ding)輸(shu)(shu)出電(dian)流為1A以上時(shi),可(ke)取1Ω/V(試驗電(dian)壓(ya)(ya))。常(chang)用(yong)水電(dian)阻(zu)(zu)(zu)作為限(xian)(xian)流電(dian)阻(zu)(zu)(zu),管(guan)子長度(du)可(ke)按150kV/m考慮,管(guan)子粗細應(ying)具有足夠的(de)熱容量(liang)(水阻(zu)(zu)(zu)液配(pei)制方法:用(yong)蒸餾水加入(ru)適量(liang)硫酸(suan)銅配(pei)制成(cheng)各種(zhong)不同的(de)阻(zu)(zu)(zu)值)。
球(qiu)間隙及保(bao)護(hu)電(dian)阻(zu):當電(dian)壓超(chao)過(guo)球(qiu)間隙整(zheng)定值時(shi)(一般取試(shi)驗電(dian)壓的110%~120%),球(qiu)間隙放(fang)電(dian),對(dui)被試(shi)品(pin)起到(dao)保(bao)護(hu)作用。球(qiu)間隙保(bao)護(hu)電(dian)阻(zu)可(ke)按(an)1Ω/V(試(shi)驗電(dian)壓)選取。
在(zai)(zai)工頻耐壓(ya)(ya)(ya)試(shi)驗(yan)(yan)中,低電(dian)(dian)壓(ya)(ya)(ya)側測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(儀表電(dian)(dian)壓(ya)(ya)(ya))不是(shi)(shi)非常準確(que)的(de)(de),其原因是(shi)(shi)由于(yu)試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)器存在(zai)(zai)著漏抗,在(zai)(zai)這(zhe)個漏抗上必(bi)然存在(zai)(zai)著壓(ya)(ya)(ya)降或(huo)容(rong)(rong)升(sheng)(sheng),使試(shi)品(pin)(pin)上的(de)(de)電(dian)(dian)壓(ya)(ya)(ya)低于(yu)或(huo)高于(yu)低壓(ya)(ya)(ya)側測(ce)量電(dian)(dian)壓(ya)(ya)(ya)表上反映出來的(de)(de)電(dian)(dian)壓(ya)(ya)(ya)。工頻耐壓(ya)(ya)(ya)試(shi)驗(yan)(yan)時(shi),被(bei)試(shi)品(pin)(pin)上的(de)(de)電(dian)(dian)壓(ya)(ya)(ya)高于(yu)試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)器的(de)(de)輸(shu)出電(dian)(dian)壓(ya)(ya)(ya),也就是(shi)(shi)所(suo)謂容(rong)(rong)升(sheng)(sheng)現象。感應(ying)耐壓(ya)(ya)(ya)試(shi)驗(yan)(yan)時(shi),試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)器的(de)(de)漏抗必(bi)然存在(zai)(zai)著壓(ya)(ya)(ya)降。為了(le)準確(que)測(ce)量被(bei)試(shi)品(pin)(pin)上所(suo)施加的(de)(de)電(dian)(dian)壓(ya)(ya)(ya),因此常在(zai)(zai)高壓(ya)(ya)(ya)側接(jie)入FRC阻容(rong)(rong)分壓(ya)(ya)(ya)器來測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(見圖(tu)5)。
工頻耐壓試驗操(cao)作注意(yi)事項
1)試驗(yan)人員(yuan)應做好分工(gong),明確相互(hu)間(jian)聯系方(fang)法。并有專門人監護現場**及觀察試品(pin)狀態。
2)被試(shi)品應先(xian)清掃干凈,并(bing)**干燥,以免(mian)損壞(huai)被試(shi)品和試(shi)驗帶來(lai)的誤差(cha)。
3)對(dui)于大(da)型試(shi)驗(yan)(yan),一般都(dou)應先進行空升試(shi)驗(yan)(yan)。即不接試(shi)品(pin)時升壓至(zhi)試(shi)驗(yan)(yan)電(dian)壓,校對(dui)各種表計,調整球間隙。
4)升壓速度(du)不(bu)(bu)能太快,并必須防止突然加壓。例如(ru)調壓器不(bu)(bu)在(zai)零位(wei)時突然合閘。也不(bu)(bu)能突然切斷(duan)電源,一般應在(zai)調壓器降至零位(wei)時拉閘。
5)當電(dian)壓(ya)升至試(shi)驗電(dian)壓(ya)時(shi),開始計時(shi),到1min后,迅(xun)速降(jiang)壓(ya)到1/3試(shi)驗電(dian)壓(ya)以(yi)下時(shi),才能(neng)拉開電(dian)源(yuan)。
6)在升(sheng)壓(ya)(ya)或耐壓(ya)(ya)試(shi)驗(yan)過程中,如發現(xian)下列不(bu)正(zheng)常情況(kuang)時,應立即降壓(ya)(ya),切斷(duan)電源。停止(zhi)試(shi)驗(yan)并查(cha)明原(yuan)因:①電壓(ya)(ya)表指針(zhen)擺動很大;②發現(xian)絕(jue)緣燒焦或冒(mao)煙;③被試(shi)品內(nei)有不(bu)正(zheng)常的(de)聲音(yin)。
7)耐壓試(shi)驗(yan)前后應(ying)測量(liang)絕(jue)緣(yuan)電阻(zu),檢(jian)查絕(jue)緣(yuan)情況。
試驗變壓(ya)器在(zai)做被試品(pin)的直流(liu)耐壓(ya)或泄露試驗時接線原(yuan)理(li)圖如(ru)圖6。
注(zhu):此(ci)試驗應先抽出(chu)短路桿“D”,圖6中所示。
圖中:VD—高壓(ya)硅堆 R1—限流電(dian)阻 C1—高壓(ya)濾波(bo)電(dian)容 FRC—阻容分壓(ya)器 CX—被試品(pin) μA—帶保護微安表
泄露試(shi)驗(yan)中(zhong)限流(liu)(liu)電(dian)阻(zu)R1選(xuan)擇在額定(ding)輸出(chu)電(dian)壓時,輸出(chu)端短路電(dian)流(liu)(liu)不超過高(gao)壓硅(gui)堆的*大整(zheng)流(liu)(liu)。如電(dian)壓硅(gui)堆的*大整(zheng)流(liu)(liu)電(dian)流(liu)(liu)為100mA時用于60kV的試(shi)驗(yan)裝置中(zhong),限流(liu)(liu)電(dian)阻(zu)按R1=60/0.1=600kΩ選(xuan)擇。限流(liu)(liu)電(dian)阻(zu)還應具有(you)足夠的容量(liang)和沿面放電(dian)距(ju)離。
高壓濾波電(dian)容(rong)(rong)C1一般(ban)選擇在0.01~0.1μF,當(dang)被試品(pin)的電(dian)容(rong)(rong)量(liang)很大時(shi),C1可(ke)省略(lve)不(bu)用。
泄(xie)露試驗的操作及注意事項
1)試(shi)驗前應先檢查被試(shi)品是否(fou)停電,接地放(fang)電,一切對(dui)外連線是否(fou)擦干凈。要嚴防將試(shi)驗電壓(ya)加(jia)到有(you)人工作的部位上去。
2)接好試(shi)驗(yan)裝置(zhi)的(de)(de)接線后,應復(fu)查無誤后才可(ke)加壓。應特別注(zhu)意檢查高壓設備及引線與地、與操作(zuo)人員的(de)(de)**距離,被(bei)試(shi)品的(de)(de)外殼是否可(ke)靠(kao)接地,要按**規程(cheng)中所規定的(de)(de)內容(rong)進(jin)行(xing)試(shi)驗(yan)。
3)對于大電(dian)(dian)容量設備應緩慢(man)升壓,防止被試(shi)品(pin)的(de)充電(dian)(dian)電(dian)(dian)流燒壞微安(an)表。必(bi)要時(shi)應分級(ji)加(jia)壓,分別讀取各(ge)級(ji)電(dian)(dian)壓下微安(an)表的(de)穩定(ding)讀數。
4)試(shi)(shi)驗過程中,應密切監視被試(shi)(shi)品(pin)、試(shi)(shi)驗裝置(zhi)、微(wei)安表(biao),一旦發生擊(ji)穿、閃爍等異常現(xian)象(xiang)應立即(ji)降壓,切斷電源(yuan),并查明(ming)原因,詳(xiang)細記錄。
5)試(shi)驗完畢(bi),降壓,切斷電源后(hou)應將被試(shi)品及試(shi)驗裝(zhuang)置本身充分放(fang)電。
四、注(zhu)意事項
1、按照您所進行的(de)試驗(yan)接好工作線路。試驗(yan)變壓(ya)器的(de)外殼以及(ji)操作系統的(de)外殼必(bi)須(xu)可靠接地。試驗(yan)變壓(ya)器高壓(ya)繞組的(de)X端(duan)(高壓(ya)尾(wei))以及(ji)測量繞組的(de)F端(duan)必(bi)須(xu)可靠接地。
2、做串級試驗(yan)時,**級、第三(san)級試驗(yan)變(bian)(bian)壓(ya)器(qi)的(de)低(di)壓(ya)繞組(zu)的(de)X端,測(ce)量(liang)繞組(zu)的(de)F端以及高(gao)壓(ya)繞組(zu)的(de)X端(高(gao)壓(ya)尾)均(jun)接(jie)本級試驗(yan)變(bian)(bian)壓(ya)器(qi)的(de)外殼(ke)。**級、第三(san)級試驗(yan)變(bian)(bian)壓(ya)器(qi)的(de)外殼(ke)必(bi)須通過絕緣支架接(jie)地。
3、接通(tong)電源前(qian),操作系(xi)統的調壓器必須(xu)調到零(ling)位(wei)后方可(ke)接通(tong)電源,合閘,開始升(sheng)壓。
4、從零(ling)開(kai)始均勻旋轉調壓(ya)(ya)(ya)器手輪升(sheng)壓(ya)(ya)(ya)。升(sheng)壓(ya)(ya)(ya)方(fang)法(fa)有:快速(su)升(sheng)壓(ya)(ya)(ya)法(fa),即(ji)20s逐級升(sheng)壓(ya)(ya)(ya)法(fa);慢(man)速(su)升(sheng)壓(ya)(ya)(ya)法(fa),即(ji)60s逐級升(sheng)壓(ya)(ya)(ya)法(fa);極慢(man)速(su)升(sheng)壓(ya)(ya)(ya)法(fa)供選用。電壓(ya)(ya)(ya)從零(ling)開(kai)始按(an)一定的(de)升(sheng)壓(ya)(ya)(ya)方(fang)式和速(su)度(du)上升(sheng)到您所需的(de)額定試(shi)驗電壓(ya)(ya)(ya)的(de)75%后,在以每秒(miao)2%額定試(shi)驗電壓(ya)(ya)(ya)的(de)速(su)度(du)升(sheng)到您所需的(de)額定電壓(ya)(ya)(ya),并密切注意測(ce)(ce)量(liang)儀表的(de)指(zhi)示以及(ji)被(bei)試(shi)品(pin)的(de)情況(kuang)。升(sheng)壓(ya)(ya)(ya)過程(cheng)中或試(shi)驗過程(cheng)中如(ru)發現測(ce)(ce)量(liang)儀表的(de)指(zhi)示及(ji)被(bei)試(shi)品(pin)情況(kuang)異(yi)常,應立(li)即(ji)降壓(ya)(ya)(ya),切斷電源(yuan),查(cha)明(ming)情況(kuang)。
5、試(shi)驗完畢后(hou),應在數秒內勻(yun)速的將調壓(ya)器返回至零位(wei),然后(hou)切斷電源(yuan)。
6、本產品(pin)不(bu)得(de)超過額定參數(shu)使(shi)用。除試驗(yan)必(bi)須外,決不(bu)允(yun)許全電壓(ya)通電或斷(duan)電。
7、 再升壓或耐壓試驗(yan)過程(cheng)中,如(ru)發現以下不正(zheng)常情況時,應立即降壓,切斷(duan)電源,停止(zhi)試驗(yan)并查明原因(yin)。
⑴電壓表指針擺動(或數字(zi)跳動)很大
⑵電流(liu)表直(zhi)線上升
被試品內有不正常的(de)聲(sheng)音
8、圖1中第9項系壓(ya)力(li)閥(fa)及壓(ya)力(li)表,為長期(qi)關(guan)閉(bi)狀態。每6個(ge)月開閥(fa)一次,以檢(jian)查SF6壓(ya)力(li),應(ying)不小于0.2MPa(檢(jian)查壓(ya)力(li)后立即(ji)關(guan)閉(bi)閥(fa)門),低于0.2MPa時應(ying)加SF6氣體,以增加氣絕(jue)緣。
9、耐壓實(shi)驗前后(hou)應測量被(bei)試設備的(de)絕緣(yuan)電(dian)阻(zu),檢查絕緣(yuan)情況。
10、當(dang)試驗變壓器(qi)長期(qi)不使用時,應(ying)放置于通風、干(gan)燥、無陽(yang)光直射的地方(fang)。
11、該產品不允(yun)許在高于45℃的溫度下長期存(cun)放、使用、放氣。
12、運輸搬運途中(zhong)不得重(zhong)力沖擊。
13、產品(pin)緊固件及壓力閥、壓力表不(bu)得(de)擅自(zi)松(song)動。
14、使(shi)用本產品做高(gao)壓試(shi)驗時,出熟悉本說明書(shu)外,還必須嚴格執行國(guo)家有關標(biao)準和操作規程(cheng)。可參照(zhao)GB311-83《高(gao)壓輸(shu)變設(she)備的絕緣配合,高(gao)壓試(shi)驗技術》;《電氣設(she)備預防性試(shi)驗規程(cheng)》等。
五、試驗變壓器的容量選(xuan)擇
標稱(cheng)試驗變(bian)壓器(qi)容量Pn的確定公式(shi):Pn=kVn 2ωCt×10-9
式中:
Pn——標稱試驗(yan)變(bian)壓器容(rong)量(liang)(kVA)
Vn——試驗變壓(ya)器的額(e)定(ding)輸出高壓(ya)的有效值(kV)
k ——**系數(shu)。k≥1,標稱(cheng)電壓(ya)Vn≥1MV時(shi),k=2;標稱(cheng)電壓(ya)較(jiao)低(di)時(shi),k值可(ke)取(qu)高一些。
Ct——被試(shi)品的電(dian)容量(pF)
ω——角頻率,ω=2πf,f——試(shi)驗(yan)電(dian)源(yuan)的頻率
被試設(she)備的(de)電容量Ct可由交流電橋測出(chu)。Ct的(de)變化很大,
可由設備的類型而定。
典型數據(ju)如下(xia):
簡單的棒式或(huo)懸式絕緣子 幾十微法
簡(jian)單(dan)的分級套(tao)管 100~1000pF
電壓互感(gan)器(qi) 200 ~ 500pF
電力變壓器 < 1000kVA~1000pF
> 1000kVA 1000~10000pF
高壓(ya)電(dian)力電(dian)纜和油浸紙絕緣 250~300pF/m
氣體絕緣(yuan) ~60pF/m
封閉變電(dian)站(zhan),SF6氣(qi)體(ti)絕緣 100~10000Pf;
對于不同的試(shi)驗電壓Vn,選(xuan)擇不同的(適當的)**系數k。
以下列出不同的(de)Vn所選用(yong)的(de)k值(zhi)供(gong)參考(kao)。
Vn =50~100kV k = 4
Vn =150~300kV k = 3
Vn > 300kV k = 2
一、概(gai)述
工頻耐壓試驗(yan)是鑒定(ding)電力設(she)備絕緣(yuan)強度的(de)(de)*嚴格、*有效和*直接的(de)(de)方法。它(ta)能(neng)檢查出那些危險性(xing)較大的(de)(de)集中(zhong)缺陷,對判斷(duan)電力設(she)備能(neng)否繼(ji)續參加運行具(ju)有決定(ding)性(xing)作用,是保證設(she)備絕緣(yuan)水平、避免發生絕緣(yuan)事故的(de)(de)重要手段。
本(ben)裝置是根據國家(jia)*新電(dian)力(li)(li)行(xing)(xing)業標準而設(she)計的(de)、性能先(xian)進的(de)耐壓(ya)試(shi)(shi)驗(yan)設(she)備,用于對(dui)各種電(dian)器產品(pin)、電(dian)氣(qi)元件、絕(jue)(jue)緣(yuan)材料等進行(xing)(xing)規定(ding)電(dian)壓(ya)下(xia)的(de)絕(jue)(jue)緣(yuan)強度試(shi)(shi)驗(yan),以考(kao)核產品(pin)的(de)絕(jue)(jue)緣(yuan)水平,發現被試(shi)(shi)品(pin)的(de)絕(jue)(jue)緣(yuan)缺陷(xian),衡量(liang)過(guo)電(dian)壓(ya)的(de)能力(li)(li)。
二(er)、產品特(te)點
監(jian)視功能:高壓電壓 低壓電流 零位指(zhi)示 電源指(zhi)示 工(gong)作(zuo)指(zhi)示 計時指(zhi)示
保(bao)護功(gong)能(neng):過流保(bao)護、零(ling)位啟動(dong)保(bao)護、聲光語言報(bao)警(jing)提醒
采用新型(xing)時間繼電(dian)器,計(ji)時范圍更廣(1S~99H)
采用新型電流繼電器,更**、更可靠,確保人身及設備**。
試驗(yan)變(bian)壓(ya)器高(gao)壓(ya)線圈為圓筒(tong)多層塔式,由上等聚酯(zhi)漆包線及高(gao)耐壓(ya)值絕緣材(cai)料繞(rao)制而成。
試驗變壓器(5kVA以(yi)上)裝有(you)(you)可移(yi)動(dong)的鐵輪。具有(you)(you)重量輕、體積小、移(yi)動(dong)方便、性能優越等特點。
三、設備組成
1、選型配置
標準配置(zhi)
|
□ 分(fen)體式
|
操作部(bu)分:
□箱式(不大于5kVA) / □臺式
容量: kVA(小(xiao)于200kVA)
輸入:□AC220V / □AC380V
|
試驗變壓器(qi):
□交流 / □交直流
□油(you)變(bian) / □干變(bian) / □氣變(bian)
容(rong)量: kVA(小于(yu)200kVA)
輸(shu)出:AC kV(小于300kVA)
|
□ 一體式(shi)
|
□箱(xiang)式(不(bu)大于(yu)20kV) / □臺式(不(bu)大于(yu)30kV)
容(rong)量(liang): kVA(小(xiao)于300kVA)
輸(shu)(shu)入:□AC220V / □AC380V 輸(shu)(shu)出:AC kV(不大于(yu)30kV)
|
客(ke)戶(hu)選配
|
□標準高壓分壓器
|
□保護(hu)球隙
|
□直流微安表
|
□放**
|
□保護水(shui)阻
|
□高壓濾波電容
|
其它:
|
2、對(dui)應實物
四、技術指標
1、使用條件:
(1)工作場所應無嚴重(zhong)影響(xiang)絕緣(yuan)的氣體、蒸(zheng)汽、化學性(xing)塵埃及其它爆炸性(xing)和腐(fu)蝕性(xing)介質。
(2)環境溫度(du) -20~+50℃
(3)環境濕度 ≤85% RH(無凝(ning)結水)
2、控制箱(臺)參數(shu):(常規參數(shu)見下表)
規格(ge)
|
容量(liang)
|
輸 入 電 源(yuan)
|
輸 出 電 壓
|
重(zhong)量(kg)
|
相(xiang)數(shu)
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說明(ming):如(ru)有特殊(shu)參(can)數(shu)要求,可按(an)用(yong)戶(hu)的技術(shu)參(can)數(shu)進行(xing)設計制作。
3、試驗(yan)變壓(ya)器參數:(常(chang)規參數見(jian)下表)
規(gui)格
|
容量
kVA
|
低壓側
|
高壓側
|
高壓(ya)側(交直流變壓(ya)器)
|
測量變比
|
60分鐘溫升℃
|
阻抗電壓%
|
空載電流
%
|
質量
kg
|
電壓(ya)
V
|
電流(liu)
A
|
交(jiao)流輸(shu)出
|
直(zhi)流輸出
|
電(dian)壓kV
|
電流
|
電壓kV
|
電流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如有(you)特殊參數要求,可按(an)用(yong)戶的(de)技術(shu)參數進行設計(ji)制作。
上(shang)表的重量以油浸式(shi)試(shi)驗(yan)(yan)變(bian)壓器為例,干式(shi)試(shi)驗(yan)(yan)變(bian)壓器和充氣式(shi)試(shi)驗(yan)(yan)變(bian)壓器稍(shao)有不(bu)同。
五、接線(xian)及工作原理(li)
1、調壓部分接(jie)線及原理(li)
調(diao)(diao)壓部分(fen)由控制(zhi)部分(fen)和試(shi)驗(yan)變(bian)壓器組(zu)(zu)成(cheng)。控制(zhi)部分(fen)是由接觸式調(diao)(diao)壓器及其(qi)控制(zhi)、保(bao)護、測量(liang)、信號電路(lu)組(zu)(zu)成(cheng)。試(shi)驗(yan)變(bian)壓器由低壓繞(rao)組(zu)(zu)、高壓繞(rao)組(zu)(zu)、儀表繞(rao)組(zu)(zu)三部分(fen)組(zu)(zu)成(cheng)。
試驗(yan)(yan)變(bian)(bian)(bian)(bian)壓(ya)器為交直(zhi)流(liu)兩(liang)用時(shi),試驗(yan)(yan)變(bian)(bian)(bian)(bian)壓(ya)器配置(zhi)了高(gao)壓(ya)硅堆(油(you)變(bian)(bian)(bian)(bian)、氣變(bian)(bian)(bian)(bian)為內置(zhi),干(gan)變(bian)(bian)(bian)(bian)為外置(zhi)),高(gao)壓(ya)可輸(shu)出交流(liu)和直(zhi)流(liu)。輸(shu)出交流(liu)時(shi),要求接入(ru)短(duan)(duan)路(lu)桿(油(you)變(bian)(bian)(bian)(bian)、氣變(bian)(bian)(bian)(bian))或(huo)去掉外置(zhi)硅堆(干(gan)變(bian)(bian)(bian)(bian));輸(shu)出直(zhi)流(liu)時(shi),要求擰出短(duan)(duan)路(lu)桿(油(you)變(bian)(bian)(bian)(bian)、氣變(bian)(bian)(bian)(bian))或(huo)加上外置(zhi)硅堆(干(gan)變(bian)(bian)(bian)(bian))
通(tong)過(guo)接(jie)入工(gong)頻電源,調(diao)節調(diao)壓器,以獲(huo)得所需要的試驗高壓電壓值。其工(gong)作(zuo)原(yuan)理見圖1:
2、試驗(yan)部分(fen)接線及原理
做(zuo)耐(nai)壓(ya)(ya)試驗時,控制部分、變壓(ya)(ya)器的接(jie)地(di)端及(ji)高壓(ya)(ya)尾(wei)必須可靠(kao)接(jie)地(di)。有(you)條件的情況(kuang)下(xia),做(zuo)工頻耐(nai)壓(ya)(ya)試驗請加上(shang)限流電阻、標準高壓(ya)(ya)分壓(ya)(ya)器、球(qiu)隙(xi)保護電阻及(ji)保護球(qiu)隙(xi),如圖3。
做直(zhi)流耐(nai)壓試驗請另(ling)外加上微安表(biao),微安表(biao)必須接(jie)在(zai)硅(gui)堆和被試器(qi)之(zhi)間(jian),油變或氣(qi)變一般(ban)擰在(zai)高(gao)壓頭上面(mian)(要(yao)求擰出(chu)短路(lu)桿),干變擰在(zai)外置硅(gui)堆上面(mian);為了更準確顯(xian)示高(gao)壓直(zhi)流泄漏(lou)電流,請將分(fen)壓器(qi)的高(gao)壓線(xian)接(jie)在(zai)微安表(biao)和硅(gui)堆之(zhi)間(jian),(油變、氣(qi)變)如圖4,(干變)如圖5。
耐壓(ya)(ya)(ya)試驗中限流(liu)(liu)電(dian)(dian)阻R1應根據試驗變壓(ya)(ya)(ya)器的額定(ding)容量(liang)來(lai)選擇。如高壓(ya)(ya)(ya)側額定(ding)輸出電(dian)(dian)流(liu)(liu)在(zai)100~300mA時(shi),可(ke)取0.5~1Ω/V(試驗電(dian)(dian)壓(ya)(ya)(ya));高壓(ya)(ya)(ya)側額定(ding)輸出電(dian)(dian)流(liu)(liu)為1A以上時(shi),可(ke)取1Ω/V(試驗電(dian)(dian)壓(ya)(ya)(ya))。常(chang)用(yong)水(shui)電(dian)(dian)阻作為限流(liu)(liu)電(dian)(dian)阻,管(guan)子長度可(ke)按150kV/m考慮,管(guan)子粗細應具(ju)有(you)足夠的熱容量(liang)(水(shui)阻液配制(zhi)方(fang)法:用(yong)蒸餾水(shui)加入適量(liang)硫酸銅配制(zhi)成各種不(bu)同(tong)的阻值)。
球(qiu)(qiu)(qiu)間隙(xi)及保護電(dian)阻:當(dang)電(dian)壓超過(guo)球(qiu)(qiu)(qiu)間隙(xi)整定值時(一般取(qu)試(shi)(shi)驗電(dian)壓的(de)110%~120%),球(qiu)(qiu)(qiu)間隙(xi)放電(dian),對被試(shi)(shi)品起到保護作用。球(qiu)(qiu)(qiu)間隙(xi)保護電(dian)阻可按1Ω/V(試(shi)(shi)驗電(dian)壓)選取(qu)。
在(zai)工(gong)(gong)頻耐(nai)壓(ya)(ya)(ya)試(shi)(shi)驗中,低電(dian)(dian)壓(ya)(ya)(ya)側測(ce)量(liang)電(dian)(dian)壓(ya)(ya)(ya)(儀(yi)表(biao)電(dian)(dian)壓(ya)(ya)(ya))不是非常準確的(de),其(qi)原因是由(you)于(yu)試(shi)(shi)驗變壓(ya)(ya)(ya)器(qi)(qi)存(cun)在(zai)著(zhu)漏抗(kang)(kang),在(zai)這個漏抗(kang)(kang)上(shang)必然存(cun)在(zai)著(zhu)壓(ya)(ya)(ya)降(jiang)或容升(sheng),使試(shi)(shi)品(pin)上(shang)的(de)電(dian)(dian)壓(ya)(ya)(ya)低于(yu)或高于(yu)低壓(ya)(ya)(ya)側測(ce)量(liang)電(dian)(dian)壓(ya)(ya)(ya)表(biao)上(shang)反映出來的(de)電(dian)(dian)壓(ya)(ya)(ya)。工(gong)(gong)頻耐(nai)壓(ya)(ya)(ya)試(shi)(shi)驗時,被試(shi)(shi)品(pin)上(shang)的(de)電(dian)(dian)壓(ya)(ya)(ya)高于(yu)試(shi)(shi)驗變壓(ya)(ya)(ya)器(qi)(qi)的(de)輸出電(dian)(dian)壓(ya)(ya)(ya),也就是所謂容升(sheng)現(xian)象。感應耐(nai)壓(ya)(ya)(ya)試(shi)(shi)驗時,試(shi)(shi)驗變壓(ya)(ya)(ya)器(qi)(qi)的(de)漏抗(kang)(kang)必然存(cun)在(zai)著(zhu)壓(ya)(ya)(ya)降(jiang)。為(wei)了準確測(ce)量(liang)被試(shi)(shi)品(pin)上(shang)所施加的(de)電(dian)(dian)壓(ya)(ya)(ya),因此常在(zai)高壓(ya)(ya)(ya)側接(jie)入(ru)標準高壓(ya)(ya)(ya)分壓(ya)(ya)(ya)器(qi)(qi)來測(ce)量(liang)電(dian)(dian)壓(ya)(ya)(ya)。
五、面(mian)板結構說(shuo)明
1、操(cao)作箱(xiang)面板
控制(zhi)箱(xiang)為箱(xiang)式(shi)鋁(lv)合金(jin)(jin)結構,面(mian)板(ban)采用(yong)拉(la)絲鋁(lv)合金(jin)(jin)工藝,所有電器元(yuan)件(jian)均(jun)裝在骨架上,便于安裝和維修(xiu)。面(mian)板(ban)元(yuan)件(jian)布置(zhi)如下:
2、操(cao)作(zuo)臺面板
操作臺為臺式結構,殼(ke)體為冷扎(zha)鋼板結構,面板采用鋁合(he)金拉絲工藝(yi),面板元件布(bu)置如下:
六、操作指(zhi)南
本裝置(zhi)在操作之前應根據不同被試(shi)品的容(rong)量、電壓等級,先計算好*大工作電流(liu),并調整電流(liu)保護器。其試(shi)驗(yan)接線應參(can)考本說明書中圖(tu)(tu)1、圖(tu)(tu)2、圖(tu)(tu)3、圖(tu)(tu)4、圖(tu)(tu)5,必須可靠接地。
1、操作要點
(1)試(shi)驗(yan)(yan)前(qian),應(ying)了解被(bei)試(shi)品的試(shi)驗(yan)(yan)電壓(ya),同時了解被(bei)試(shi)品的其他試(shi)驗(yan)(yan)項目(mu)及以(yi)前(qian)的試(shi)驗(yan)(yan)結果。若被(bei)試(shi)品有缺陷或異常(chang),應(ying)在消除后再進行耐(nai)壓(ya)試(shi)驗(yan)(yan)。
(2)試驗現場應圍(wei)好(hao)遮攔或圍(wei)繩,掛好(hao)標示牌,并派專(zhuan)人監(jian)護。
(3)試(shi)驗前,被試(shi)品(pin)表面(mian)應(ying)擦拭干凈(jing),將被試(shi)品(pin)的外殼(ke)和非被試(shi)繞(rao)組可靠(kao)接地。被試(shi)品(pin)為新(xin)沖油(you)設備時,應(ying)按《規程(cheng)》規定(ding)使油(you)靜(jing)止一定(ding)時間再(zai)升壓,對110kV及(ji)以下的充油(you)電力(li)(li)設備,在(zai)注滿油(you)后靜(jing)置時間應(ying)不(bu)(bu)少于24小時,對220kV及(ji)330kV的充油(you)電力(li)(li)設備,靜(jing)置時間應(ying)不(bu)(bu)少于48小時。
(4)接好試驗接線后,應由有經(jing)驗的人(ren)員(yuan)檢查,確(que)認無(wu)誤(wu)后方(fang)可升壓。
(5)升(sheng)壓前(qian),首(shou)先檢查調壓器是否在(zai)(zai)零位(wei)。調壓器在(zai)(zai)零位(wei)方可升(sheng)壓。
(6)升壓(ya)(ya)(ya)過程中不(bu)僅要(yao)監視電(dian)(dian)壓(ya)(ya)(ya)表(biao)的(de)(de)變化(hua)(hua),還應監視電(dian)(dian)流表(biao)的(de)(de)變化(hua)(hua),以及被試(shi)品電(dian)(dian)流的(de)(de)變化(hua)(hua)。升壓(ya)(ya)(ya)時(shi)要(yao)均(jun)勻(yun)升壓(ya)(ya)(ya),不(bu)能太(tai)快。升至規定(ding)試(shi)驗電(dian)(dian)壓(ya)(ya)(ya)時(shi),開(kai)始計(ji)算時(shi)間,時(shi)間到(dao)后,緩(huan)慢均(jun)勻(yun)降(jiang)下電(dian)(dian)壓(ya)(ya)(ya)。絕不(bu)允(yun)許(xu)不(bu)降(jiang)壓(ya)(ya)(ya)就先跳開(kai)電(dian)(dian)源開(kai)關。
(7)試(shi)(shi)驗中發現(xian)表針擺動或被試(shi)(shi)品有異常聲(sheng)響(xiang)、冒煙(yan)等應(ying)立即降下電壓(ya),拉開電源,在高壓(ya)側掛上接地線后,再查明原因。
(8)耐壓試驗前后均應(ying)測量被試品的(de)絕(jue)緣(yuan)電阻。
2、操作(zuo)步(bu)驟
(1) 按(an)試(shi)驗要求(qiu)將控制(zhi)部分、試(shi)驗變壓器、被試(shi)品正確(que)接好線,必須可靠接地,請參考圖1、圖2、圖3、圖4、圖5。
(2) 根據試驗的要求,整定“時間繼(ji)電器(qi)”及“過流繼(ji)電器(qi)”。
A 時(shi)間繼電器設(she)置:
T1,T2,T3,T4設置0~9任意數字,T可設置為H(小時),M(分鐘),S(秒)。
根(gen)據試驗要求,在(zai)1S~99H內可以任意設置定(ding)時時間。
B 過流繼電(dian)器(qi)設置:
過(guo)流(liu)(liu)(liu)(liu)動(dong)作設定值=過(guo)流(liu)(liu)(liu)(liu)繼(ji)電(dian)(dian)器(qi)刻度(du)盤讀數(shu)×測量(liang)變比×K,其中K為(wei)電(dian)(dian)流(liu)(liu)(liu)(liu)倍率(lv)/切除開關(guan)的狀態值,分別為(wei)X1,X2,OFF,電(dian)(dian)流(liu)(liu)(liu)(liu)倍率(lv)/切除開關(guan)處于×1,×2位置時(shi),K值分別為(wei)1、2,切換(huan)為(wei)OFF擋時(shi),K值為(wei)+∞。(注(zhu):不要使(shi)用OFF檔,因(yin)為(wei)會(hui)使(shi)變壓器(qi)失去過(guo)流(liu)(liu)(liu)(liu)保護功能而導(dao)致設備損壞。測量(liang)變比為(wei)電(dian)(dian)流(liu)(liu)(liu)(liu)互感(gan)器(qi)的變比,沒有電(dian)(dian)流(liu)(liu)(liu)(liu)互感(gan)器(qi)時(shi)為(wei)1)。
(3) 接入電源,此時(shi),“電源燈(deng)(deng)”亮,表示(shi)外部電源已引(yin)入。如(ru)(ru)“零(ling)位(wei)(wei)燈(deng)(deng)”亮,表示(shi)調壓器在零(ling)位(wei)(wei)。如(ru)(ru)“零(ling)位(wei)(wei)燈(deng)(deng)”不亮,應逆時(shi)針旋轉調節調壓器手(shou)柄(bing)至“零(ling)位(wei)(wei)燈(deng)(deng)”亮,表示(shi)可進(jin)行調壓操作。
(4)按“啟動按鈕(niu)”。此(ci)時,“送(song)電(dian)燈”,“電(dian)源燈”和“零位燈”亮;進入送(song)電(dian)狀(zhuang)態。
(5)以(yi)2kV/S勻速順時(shi)針旋轉(zhuan)調壓器手柄至被試(shi)品規(gui)定的耐(nai)壓值,并密(mi)(mi)切注(zhu)視電(dian)流(liu)(liu)表(直(zhi)流(liu)(liu)耐(nai)壓試(shi)驗時(shi),同(tong)時(shi)密(mi)(mi)切注(zhu)視直(zhi)流(liu)(liu)微安表)。此時(shi),“電(dian)源燈(deng)”,“工(gong)作燈(deng)”亮;“零位燈(deng)”滅(mie)。
(6)根據試驗啟動“計(ji)時按鈕”,計(ji)時開(kai)始(shi),并注意被試品的情況(kuang)。
(7)當耐(nai)壓(ya)計時到時,操作(zuo)臺自動(dong)聲光報警。應立即逆時針(zhen)旋轉調壓(ya)器手柄至(zhi)零位(wei),按下停止(zhi)按鈕(niu)和(he)解除計時按鈕(niu)自鎖狀(zhuang)態(tai)。此時“電源燈”, “零位(wei)燈”亮,“工作(zuo)燈”滅。試驗即告完畢
(8)拔掉電源,拆除接線,試驗(yan)結束。
(9)在升(sheng)壓或耐壓過(guo)程中,如發生短(duan)路、閃絡、擊穿過(guo)流時,過(guo)流繼電器動作,切斷主回路。此時應將調壓器逆時針旋轉至零位,切斷電源,并(bing)查(cha)明原因,并(bing)作詳細記錄。
(10)試驗完畢,降壓,切斷電源(yuan)后應用放(fang)**將被試品及試驗裝(zhuang)置(zhi)本身充分放(fang)電。
七、產品維護
1、開(kai)箱驗(yan)收(shou)時,應檢(jian)查主控回路(lu)接線是(shi)否松動(dong),調(diao)壓器電(dian)刷是(shi)否接觸良好;
2、長期不用時,使(shi)用前應用500V兆(zhao)歐表測量(liang)絕(jue)緣電阻,其阻值不低于0.5MΩ;
3、電(dian)源電(dian)壓應符合(he)控制箱(xiang)(臺)銘牌上的(de)輸入(ru)電(dian)壓值;
4、本裝置(zhi)設(she)(she)有過電流保護(hu),出廠已調整為額(e)定電流的(de)50%。用于(yu)小負載時,應根據(ju)被試(shi)品的(de)額(e)定容量電流重新(xin)設(she)(she)定;
5、使用完(wan)畢(bi)后,應關好控制箱(xiang)(臺)門,以保(bao)持控制箱(xiang)(臺)內部清(qing)潔。
八、注(zhu)意事(shi)項
1、按照您所(suo)進行的(de)(de)(de)(de)試(shi)驗(yan)接好(hao)工作線路。試(shi)驗(yan)變(bian)(bian)壓(ya)器的(de)(de)(de)(de)外殼(ke)以及(ji)操作系統(tong)的(de)(de)(de)(de)外殼(ke)必(bi)須可(ke)靠接地(di)。試(shi)驗(yan)變(bian)(bian)壓(ya)器的(de)(de)(de)(de)高壓(ya)繞(rao)(rao)組的(de)(de)(de)(de)X端(高壓(ya)尾)以及(ji)測量繞(rao)(rao)組的(de)(de)(de)(de)F端必(bi)須可(ke)靠接地(di)。
2、做串(chuan)級(ji)試(shi)驗(yan)時(shi),**級(ji)、第三(san)級(ji)試(shi)驗(yan)變壓(ya)器(qi)的低壓(ya)繞組(zu)成X端(duan),測(ce)量繞組(zu)的F端(duan)以(yi)及(ji)高壓(ya)繞組(zu)的X端(duan)(高壓(ya)端(duan))均接本級(ji)試(shi)驗(yan)變壓(ya)器(qi)具外殼。**級(ji)、第三(san)級(ji)試(shi)驗(yan)變壓(ya)器(qi)的外殼必須通過絕(jue)緣支架接地。
3、接(jie)通電(dian)源(yuan)(yuan)前,操作系(xi)統的(de)(de)調壓(ya)(ya)器必須(xu)調到零(ling)位后方(fang)可接(jie)通電(dian)源(yuan)(yuan),合(he)閘,開(kai)始(shi)升(sheng)(sheng)壓(ya)(ya)。從零(ling)開(kai)始(shi)勻速(su)旋轉調壓(ya)(ya)器手輪升(sheng)(sheng)壓(ya)(ya)。升(sheng)(sheng)壓(ya)(ya)方(fang)式有:快速(su)升(sheng)(sheng)壓(ya)(ya)法,即(ji)20s逐(zhu)級(ji)升(sheng)(sheng)壓(ya)(ya)法;慢(man)速(su)升(sheng)(sheng)壓(ya)(ya)法,即(ji)60s逐(zhu)級(ji)升(sheng)(sheng)壓(ya)(ya)法;極慢(man)速(su)升(sheng)(sheng)壓(ya)(ya)法供選(xuan)用。電(dian)壓(ya)(ya)從零(ling)開(kai)始(shi)按一定(ding)的(de)(de)升(sheng)(sheng)壓(ya)(ya)方(fang)式和速(su)度上升(sheng)(sheng)到您所需的(de)(de)額(e)定(ding)試(shi)(shi)驗(yan)電(dian)壓(ya)(ya)的(de)(de)75%后,再以每秒2%額(e)定(ding)試(shi)(shi)驗(yan)電(dian)壓(ya)(ya)的(de)(de)速(su)度升(sheng)(sheng)到您所需的(de)(de)試(shi)(shi)驗(yan)電(dian)壓(ya)(ya),并(bing)密(mi)切注意測(ce)(ce)量儀表(biao)(biao)的(de)(de)及(ji)被試(shi)(shi)品的(de)(de)情況。升(sheng)(sheng)壓(ya)(ya)過程(cheng)中(zhong)或(huo)試(shi)(shi)驗(yan)過程(cheng)中(zhong)如發現(xian)測(ce)(ce)量儀表(biao)(biao)的(de)(de)指示(shi)及(ji)被試(shi)(shi)品情況異常,應立(li)即(ji)降(jiang)壓(ya)(ya),切斷電(dian)源(yuan)(yuan),查明(ming)情況。
4、試驗完畢(bi)后,應在數秒(miao)內勻(yun)速的將調(diao)壓器返回至零位,然后切(qie)斷電源(yuan)。本產品不得超過(guo)額定參數使用。
5、使(shi)用本產(chan)品做高壓試驗時,除(chu)熟(shu)悉本說明書外,還必(bi)須(xu)嚴格執行國家有關標準(zhun)和操作規(gui)程(cheng)。可參照GB311.1 – 97《高壓輸變設備的絕緣配合,高壓試驗技術》;《電氣設備預防性試驗規(gui)程(cheng)》等
一、概述
智(zhi)(zhi)能耐壓試驗裝置(zhi)是根據國家*新電力行業標準而設(she)計的、性能先進的智(zhi)(zhi)能型耐壓試驗設(she)備,用于對各(ge)種電器產品(pin)、電氣元件、絕(jue)緣材料等進行規(gui)定(ding)電壓下的絕(jue)緣強(qiang)度試驗,以(yi)考核(he)產品(pin)的絕(jue)緣水平(ping),發現被試品(pin)的絕(jue)緣缺陷,衡量過電壓的能力。廣泛應用于電工制(zhi)造部門(men)、電力運行部門(men)、科研單位(wei)和(he)高等院校。
二、產品特點(dian)
1. 320×240液晶顯示器、高速(su)熱敏打印機。
2. 高(gao)(gao)壓電(dian)壓、高(gao)(gao)壓電(dian)流、低壓電(dian)壓、低壓電(dian)流4路測量方式,高(gao)(gao)精度傳感(gan)器和(he)高(gao)(gao)性能14位AD采集(ji)芯片(pian)。
3. 人(ren)機對話全(quan)鍵盤(pan)操作(zuo)方式,智能(neng)化工作(zuo)全(quan)過程,任選自動方式和手(shou)動方式。
4. 實(shi)時(shi)顯(xian)示高(gao)壓(ya)(ya)電(dian)(dian)壓(ya)(ya)、高(gao)壓(ya)(ya)電(dian)(dian)流、低壓(ya)(ya)電(dian)(dian)壓(ya)(ya)、低壓(ya)(ya)電(dian)(dian)流,時(shi)間(jian)及耐壓(ya)(ya)結果,顯(xian)示直觀(guan)明(ming)了。
5. 完善的(de)過(guo)壓、過(guo)流(liu)保護,任意設(she)定輸(shu)出電壓、高壓電流(liu)上(shang)限、低壓電流(liu)上(shang)限和計時時間。
6. 具有回零(ling)檢測功能,回零(ling)確定后才可(ke)(ke)進行試驗,**可(ke)(ke)靠。
7. 具有(you)絕緣電阻測試功(gong)能,直接反映被試品絕緣強度。
8. 逼近式(shi)調壓算法,到達設定電壓后自動耐壓計時,計時結束后自動降壓回零。
9. 超過設(she)定高壓電(dian)(dian)流或(huo)低(di)壓電(dian)(dian)流時(shi)自(zi)動切斷電(dian)(dian)壓輸(shu)出,降壓回零,并發(fa)生聲光報警(jing)。
10. 精良的軟硬件(jian)抗干擾(rao)(rao)設計,多種抗干擾(rao)(rao)手段(duan),適應(ying)惡劣電磁環境。
11. 自(zi)動錯誤診斷(duan),易于發(fa)現和解(jie)決問題。
12. 可選配無線遙(yao)控控制功能、遠程通信、門聯(lian)鎖(suo)警鈴、外接(jie)分(fen)壓器校驗接(jie)口等。
三、設備(bei)組成
1、選(xuan)型配置
標準配置
|
□ 分體式
|
操作部(bu)分:
□箱式(shi)(不大于5kVA) / □臺式(shi)
容(rong)量: kVA(小于200kVA)
輸(shu)入:□AC220V / □AC380V
|
試驗變壓器:
□交(jiao)流 / □交(jiao)直流
□油變(bian)(bian) / □干(gan)變(bian)(bian) / □氣變(bian)(bian)
容量: kVA(小于(yu)200kVA)
輸出:AC kV(小于(yu)300kVA)
|
□ 一體式
|
□箱式(不大于20kV) / □臺式(不大于30kV)
容量(liang): kVA(小于300kVA)
輸入:□AC220V / □AC380V 輸出(chu):AC kV(不大(da)于30kV)
|
客戶選(xuan)配
|
□標準高壓(ya)分壓(ya)器(qi)
|
□保(bao)護球隙
|
□直流微安表
|
□放**
|
□保護水阻
|
□高壓濾(lv)波(bo)電容(rong)
|
其它:
|
2、對(dui)應實物
四、技術指(zhi)標
1、使用條(tiao)件:
(1)工(gong)作(zuo)場所(suo)應無嚴重影響絕(jue)緣(yuan)的氣體、蒸汽(qi)、化(hua)學性(xing)塵埃及其它爆(bao)炸(zha)性(xing)和腐蝕性(xing)介質。
(2)環(huan)境溫度 -20~+50℃
(3)環(huan)境濕度 ≤85% RH(無凝(ning)結水)
2、控(kong)制箱(臺(tai))參數:(常規參數見下表)
(1)計時(shi)范圍:0-999S
(3)電壓精度 ≤1.5% ±1個字(F.S)
(4)電流精度 ≤1.5% ±1個字(zi)(F.S)
規格
|
容量
|
輸 入 電(dian) 源
|
輸(shu) 出(chu) 電 壓
|
重量(liang)(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說明(ming):如有特(te)殊參(can)數(shu)要求,可按用戶的技術參(can)數(shu)進行(xing)設(she)計制作(zuo)。
3、試驗變壓器參數:(常(chang)規(gui)參數見下表)
規格
|
容量(liang)
kVA
|
低壓側
|
高(gao)壓側
|
高壓(ya)側(ce)(交(jiao)直流變壓(ya)器(qi))
|
測(ce)量變比
|
60分鐘溫升℃
|
阻抗(kang)電壓%
|
空載電流
%
|
質量
kg
|
電壓
V
|
電(dian)流
A
|
交流輸出
|
直流(liu)輸出
|
電(dian)壓kV
|
電流
|
電壓kV
|
電流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如有特殊參(can)數要求,可按用戶的(de)技術參(can)數進行(xing)設計制作。
上(shang)表的重(zhong)量(liang)以油(you)浸式試(shi)(shi)驗變壓器為(wei)例,干式試(shi)(shi)驗變壓器和充氣式試(shi)(shi)驗變壓器稍有不同。
五(wu)、接線及工(gong)作原理
1、調壓(ya)部(bu)分接線及(ji)原理
調壓(ya)部(bu)分(fen)由(you)控(kong)制部(bu)分(fen)和試驗變(bian)壓(ya)器(qi)組(zu)(zu)成。控(kong)制部(bu)分(fen)是由(you)接(jie)觸式調壓(ya)器(qi)、單片機(ji)(ji)控(kong)制系統、液(ye)晶(jing)、打印機(ji)(ji)、信號測量、電(dian)路保護組(zu)(zu)成。試驗變(bian)壓(ya)器(qi)由(you)低壓(ya)繞組(zu)(zu)、高壓(ya)繞組(zu)(zu)、儀表(biao)繞組(zu)(zu)三部(bu)分(fen)組(zu)(zu)成。
試驗變(bian)(bian)壓器為交(jiao)直流(liu)兩用(yong)時(shi),試驗變(bian)(bian)壓器配置(zhi)了高壓硅(gui)堆(油變(bian)(bian)、氣(qi)變(bian)(bian)為內置(zhi),干(gan)變(bian)(bian)為外(wai)置(zhi)),高壓可(ke)輸出(chu)(chu)交(jiao)流(liu)和(he)直流(liu)。輸出(chu)(chu)交(jiao)流(liu)時(shi),要(yao)求接入短(duan)路(lu)(lu)桿(gan)(油變(bian)(bian)、氣(qi)變(bian)(bian))或去掉外(wai)置(zhi)硅(gui)堆(干(gan)變(bian)(bian));輸出(chu)(chu)直流(liu)時(shi),要(yao)求擰(ning)出(chu)(chu)短(duan)路(lu)(lu)桿(gan)(油變(bian)(bian)、氣(qi)變(bian)(bian))或加上外(wai)置(zhi)硅(gui)堆(干(gan)變(bian)(bian))
通過(guo)接入(ru)工頻電(dian)源,調節調壓器,以(yi)獲得所需要(yao)的試驗高壓電(dian)壓值。其工作(zuo)原理見圖1:
2、試(shi)驗部分接線及原理
做(zuo)耐壓試(shi)驗時,控制部分(fen)(fen)、變(bian)壓器的(de)接地端(duan)及(ji)高(gao)壓尾必須(xu)可靠接地。有條件的(de)情況下(xia),做(zuo)工頻(pin)耐壓試(shi)驗請(qing)加上限流電阻、標準(zhun)高(gao)壓分(fen)(fen)壓器、球隙保護電阻及(ji)保護球隙,如圖3。
做直(zhi)流耐壓試驗請另外加上微安(an)(an)表,微安(an)(an)表必(bi)須(xu)接(jie)在(zai)硅(gui)堆(dui)和被試器(qi)之(zhi)間,油變或氣變一般(ban)擰在(zai)高(gao)壓頭(tou)上面(要求擰出短路(lu)桿),干變擰在(zai)外置硅(gui)堆(dui)上面;為了更準(zhun)確(que)顯示高(gao)壓直(zhi)流泄漏電流,請將分壓器(qi)的高(gao)壓線接(jie)在(zai)微安(an)(an)表和硅(gui)堆(dui)之(zhi)間,(油變、氣變)如(ru)圖4,(干變)如(ru)圖5。
耐壓(ya)(ya)試(shi)驗(yan)(yan)中限流(liu)電(dian)(dian)阻(zu)R1應根據試(shi)驗(yan)(yan)變壓(ya)(ya)器的額(e)定容(rong)量(liang)來選(xuan)擇。如(ru)高壓(ya)(ya)側額(e)定輸(shu)出電(dian)(dian)流(liu)在100~300mA時,可取(qu)(qu)0.5~1Ω/V(試(shi)驗(yan)(yan)電(dian)(dian)壓(ya)(ya));高壓(ya)(ya)側額(e)定輸(shu)出電(dian)(dian)流(liu)為1A以上時,可取(qu)(qu)1Ω/V(試(shi)驗(yan)(yan)電(dian)(dian)壓(ya)(ya))。常用水(shui)電(dian)(dian)阻(zu)作為限流(liu)電(dian)(dian)阻(zu),管子長度可按(an)150kV/m考慮,管子粗細應具有足夠的熱容(rong)量(liang)(水(shui)阻(zu)液配(pei)制方法:用蒸餾(liu)水(shui)加(jia)入適量(liang)硫酸銅配(pei)制成各種(zhong)不同的阻(zu)值)。
球間(jian)隙及保護(hu)電(dian)阻:當電(dian)壓(ya)超過(guo)球間(jian)隙整定值時(一(yi)般取試(shi)(shi)驗(yan)電(dian)壓(ya)的110%~120%),球間(jian)隙放電(dian),對被試(shi)(shi)品起(qi)到保護(hu)作(zuo)用。球間(jian)隙保護(hu)電(dian)阻可按1Ω/V(試(shi)(shi)驗(yan)電(dian)壓(ya))選(xuan)取。
在(zai)工頻耐壓(ya)(ya)試(shi)驗(yan)中,低電(dian)(dian)(dian)壓(ya)(ya)側(ce)測(ce)量(liang)(liang)電(dian)(dian)(dian)壓(ya)(ya)(儀表電(dian)(dian)(dian)壓(ya)(ya))不是(shi)非常準確(que)的(de)(de)(de),其原(yuan)因是(shi)由于試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)器存在(zai)著(zhu)漏抗,在(zai)這個(ge)漏抗上(shang)(shang)必然存在(zai)著(zhu)壓(ya)(ya)降或(huo)容升(sheng)(sheng),使試(shi)品上(shang)(shang)的(de)(de)(de)電(dian)(dian)(dian)壓(ya)(ya)低于或(huo)高(gao)于低壓(ya)(ya)側(ce)測(ce)量(liang)(liang)電(dian)(dian)(dian)壓(ya)(ya)表上(shang)(shang)反映出來的(de)(de)(de)電(dian)(dian)(dian)壓(ya)(ya)。工頻耐壓(ya)(ya)試(shi)驗(yan)時,被(bei)試(shi)品上(shang)(shang)的(de)(de)(de)電(dian)(dian)(dian)壓(ya)(ya)高(gao)于試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)器的(de)(de)(de)輸出電(dian)(dian)(dian)壓(ya)(ya),也就是(shi)所(suo)謂容升(sheng)(sheng)現(xian)象。感應耐壓(ya)(ya)試(shi)驗(yan)時,試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)器的(de)(de)(de)漏抗必然存在(zai)著(zhu)壓(ya)(ya)降。為(wei)了準確(que)測(ce)量(liang)(liang)被(bei)試(shi)品上(shang)(shang)所(suo)施加的(de)(de)(de)電(dian)(dian)(dian)壓(ya)(ya),因此常在(zai)高(gao)壓(ya)(ya)側(ce)接(jie)入標準高(gao)壓(ya)(ya)分壓(ya)(ya)器來測(ce)量(liang)(liang)電(dian)(dian)(dian)壓(ya)(ya)。
六、操作(zuo)要點
1、試(shi)驗前,應了解被(bei)試(shi)品(pin)的試(shi)驗電壓(ya),同時了解被(bei)試(shi)品(pin)的其他試(shi)驗項目及以(yi)前的試(shi)驗結果。若(ruo)被(bei)試(shi)品(pin)有缺陷或異(yi)常,應在消(xiao)除(chu)后再進行(xing)耐(nai)壓(ya)試(shi)驗。
2、試驗(yan)現場應(ying)圍好遮(zhe)攔或圍繩,掛好標示牌,并派專人監護。
3、試(shi)驗前,被試(shi)品表面應擦拭(shi)干凈,將被試(shi)品的外殼和非被試(shi)繞組(zu)可靠接地。被試(shi)品為新沖油(you)(you)設備(bei)時(shi)(shi),應按《規程》規定使油(you)(you)靜止一定時(shi)(shi)間(jian)再升壓,對(dui)110kV及(ji)以下的充油(you)(you)電力(li)設備(bei),在注滿油(you)(you)后靜置時(shi)(shi)間(jian)應不少于(yu)24小(xiao)時(shi)(shi),對(dui)220kV及(ji)330kV的充油(you)(you)電力(li)設備(bei),靜置時(shi)(shi)間(jian)應不少于(yu)48小(xiao)時(shi)(shi)。
4、接好試驗接線后(hou)(hou),應由(you)有(you)經驗的人(ren)員檢查,確認無誤(wu)后(hou)(hou)方可升壓。
5、升壓(ya)(ya)前,首先檢查調壓(ya)(ya)器是否在零(ling)(ling)位。調壓(ya)(ya)器在零(ling)(ling)位方可升壓(ya)(ya)。
6、升(sheng)(sheng)壓過程中不(bu)僅要(yao)(yao)監視(shi)電(dian)(dian)壓的變(bian)(bian)化(hua),還(huan)應(ying)監視(shi)電(dian)(dian)流的變(bian)(bian)化(hua),以(yi)及被試品泄漏電(dian)(dian)流的變(bian)(bian)化(hua)。升(sheng)(sheng)壓時(shi)(shi)要(yao)(yao)均勻升(sheng)(sheng)壓,不(bu)能太快。升(sheng)(sheng)至規定(ding)試驗(yan)電(dian)(dian)壓時(shi)(shi),開始計時(shi)(shi),時(shi)(shi)間到后,緩慢均勻降(jiang)下電(dian)(dian)壓。絕不(bu)允許不(bu)降(jiang)壓就先(xian)跳開電(dian)(dian)源開關。
7、試驗(yan)中發現被(bei)試品(pin)(pin)有異常聲響(xiang)、冒煙等(deng)應(ying)立即降下電壓,拉開(kai)電源,在高壓側(ce)掛上接地線后,再查明(ming)原(yuan)因。耐壓試驗(yan)前后均(jun)應(ying)測量(liang)被(bei)試品(pin)(pin)的絕緣電阻。
七、面(mian)板(ban)功能(neng)說明
打(da)(da)(da)印機(ji):打(da)(da)(da)印機(ji)是熱(re)敏打(da)(da)(da)印機(ji),當試驗(yan)完成后按(an)(an)鍵盤上的“打(da)(da)(da)印”按(an)(an)鈕打(da)(da)(da)印試驗(yan)結果(guo)。
RS232:RS232是與計(ji)算機相連的(de)串口通信接口,是用戶選配接口,本裝(zhuang)置(zhi)沒有(you)配置(zhi)這個(ge)接口。
LCD對比(bi)度(du):因為液晶顯示屏(ping)在(zai)溫度(du)和光線有(you)所不(bu)同(tong)時稍(shao)有(you)些變化(hua),可以通過LCD對比(bi)度(du)調節背光到適(shi)合亮度(du)。
液晶(jing): 320x240像素點陣(zhen)白色背光(guang)液晶(jing),在強光(guang)和(he)陰暗環境下(xia)都十分清楚。
指(zhi)示燈(deng)(deng):由啟動燈(deng)(deng)、零(ling)位燈(deng)(deng)、指(zhi)示燈(deng)(deng)三個燈(deng)(deng)組成,啟動燈(deng)(deng)和警(jing)示燈(deng)(deng)是高亮七彩燈(deng)(deng)。
操(cao)作提(ti)示:有(you)一些(xie)簡短的提(ti)示語句和(he)安(an)裝接線圖(tu)。
緊(jin)急開(kai)關:在緊(jin)急情況(kuang)下按此開(kai)關,即(ji)可以(yi)切斷變壓器電源,也(ye)可以(yi)切斷工作電源。(箱式(shi)(shi)安裝(zhuang)在面板上,臺式(shi)(shi)安裝(zhuang)在柜體上)
鍵盤:由(you)上、下、左、右、設置、打印(yin)、確定、取(qu)消8個鍵組成,是用戶和設備交互的終端。
電(dian)源開關:工作電(dian)源,帶通電(dian)指示燈。
八、軟件使用(yong)說明
按試驗(yan)要求(qiu)將控制(zhi)部分(fen)、試驗(yan)變壓器、被試品正(zheng)確(que)接(jie)好線,必須(xu)可靠接(jie)地,請參考(kao)圖1、圖2、圖3、圖4、圖5。
1、開機使用
開機處于“歡迎界面”,如圖7:
根據(ju)鍵盤的示圖8,按上↑、下↓、左←,右→可以切換“自動耐壓(ya)試(shi)(shi)(shi)(shi)驗”或“手動耐壓(ya)試(shi)(shi)(shi)(shi)驗”,在“自動試(shi)(shi)(shi)(shi)驗”或“手動試(shi)(shi)(shi)(shi)驗”里面選擇“交(jiao)流(liu)試(shi)(shi)(shi)(shi)驗方(fang)(fang)式”或“直(zhi)流(liu)試(shi)(shi)(shi)(shi)驗方(fang)(fang)式”。如圖9
說(shuo)明:
(1)當配置的是交(jiao)直流(liu)(liu)(liu)兩用控制部分時,使(shi)用直流(liu)(liu)(liu)輸出(chu)(chu)(chu)時軟件操作請進入(ru)直流(liu)(liu)(liu)試驗(yan)方式(shi),交(jiao)流(liu)(liu)(liu)輸出(chu)(chu)(chu)時軟件操作請進入(ru)交(jiao)流(liu)(liu)(liu)試驗(yan)方式(shi),如果選擇(ze)錯誤(wu)會導致儀器顯示電壓會和(he)輸出(chu)(chu)(chu)實際(ji)電壓不一致。
(2)當配置的是交(jiao)直流(liu)兩用變壓(ya)器時(shi),使用直流(liu)時(shi)請將變壓(ya)器的短(duan)路桿取出,當使用交(jiao)流(liu)時(shi)請將短(duan)路桿插入擰緊。
(3)如(ru)果(guo)配置的是交(jiao)流控制部分時(shi),軟件(jian)界(jie)面里就(jiu)沒(mei)有交(jiao)直流試(shi)驗方式(如(ru)圖9)的選擇項。
選(xuan)中試驗(yan)方(fang)式(shi)后,按確(que)定可以進入主界面,如圖(tu)10:
動態顯示區:一直處于采集信(xin)號,并(bing)顯示高壓(ya)(ya)電壓(ya)(ya)、高壓(ya)(ya)電流(liu)、低壓(ya)(ya)電壓(ya)(ya)、低壓(ya)(ya)電流(liu)。
結(jie)果(guo)顯示區(qu):如(ru)果(guo)試驗沒有被擊穿時,顯示平均(jun)(jun)高(gao)壓(ya)(ya)電壓(ya)(ya),平均(jun)(jun)高(gao)壓(ya)(ya)電流,平均(jun)(jun)低(di)(di)壓(ya)(ya)電壓(ya)(ya),平均(jun)(jun)低(di)(di)壓(ya)(ya)電流,絕緣電阻;否(fou)之,顯示峰值(zhi)(zhi)電壓(ya)(ya),峰值(zhi)(zhi)電流,低(di)(di)壓(ya)(ya)電壓(ya)(ya),低(di)(di)壓(ya)(ya)電流。
設置(zhi)數(shu)據區:設置(zhi)試(shi)驗中(zhong)需要的參數(shu)數(shu)據輸出電壓(ya)為(wei)(wei)在自(zi)動(dong)方(fang)式下的升壓(ya)目標耐壓(ya)值耐壓(ya)時(shi)間為(wei)(wei)耐壓(ya)過(guo)程的時(shi)間長(chang)度電流(liu)(liu)(liu)上(shang)限(xian)為(wei)(wei)高壓(ya)電流(liu)(liu)(liu)峰值的上(shang)限(xian),高壓(ya)電流(liu)(liu)(liu)超(chao)過(guo)電流(liu)(liu)(liu)上(shang)限(xian)將(jiang)認為(wei)(wei)擊穿過(guo)流(liu)(liu)(liu)保(bao)護為(wei)(wei)低壓(ya)電流(liu)(liu)(liu)峰值的上(shang)限(xian),低壓(ya)電流(liu)(liu)(liu)超(chao)過(guo)過(guo)流(liu)(liu)(liu)保(bao)護將(jiang)認為(wei)(wei)擊穿
信(xin)息顯示(shi)(shi)區:顯示(shi)(shi)試驗(yan)過程中的試驗(yan)狀態(tai)和提示(shi)(shi)信(xin)息。
試驗操作區:選擇(ze)設置、試驗、回零(ling)命令。
2、設置(zhi)參數
在(zai)主界面上,選中“設置(zhi)”,然后按確(que)定后進入(ru)設置(zhi)界面,如圖11:
按(an)左←,右→時切換光(guang)標(biao)(biao)移(yi)動位置,按(an)上↑、下↓時更改光(guang)標(biao)(biao)位置數據的(de)值(zhi)(zhi)。光(guang)標(biao)(biao)位置和(he)設置的(de)數值(zhi)(zhi)全(quan)部可以自(zi)動循環,前(qian)且在使用時有(you)默認的(de)標(biao)(biao)準值(zhi)(zhi)。如(ru)果(guo)所有(you)的(de)參(can)數都設置完成,按(an)取消(xiao)退出設置回到主界面開始狀態(tai)。
3、手動試驗
零位檢查—當選中“試(shi)驗(yan)(yan)”后,按(an)確定就進入提示試(shi)驗(yan)(yan)狀態(tai)。如果調壓器不(bu)在零位,將提示“試(shi)驗(yan)(yan)前(qian)請先回零”,退(tui)出試(shi)驗(yan)(yan)并且(qie)切換到回零命令。
試驗過程—回(hui)零確(que)認后(hou),可以進(jin)行試驗。選中“試驗”后(hou)按確(que)定(ding),接觸器合閘,這時輸出電壓幾乎為0,如圖12:
按上(shang)↑,高壓(ya)電(dian)壓(ya)將不斷升壓(ya),松開就(jiu)停止升壓(ya),如果到(dao)上(shang)限就(jiu)提示滿(man)量程;
按下(xia)↓,高壓電壓將不斷降壓,松開(kai)就停止降壓,如(ru)果(guo)到(dao)下(xia)限就提示已(yi)回(hui)零;
按計(ji)時(shi)←,計(ji)時(shi)開始工作,到耐壓(ya)時(shi)間(jian)計(ji)時(shi)結束完成試驗;
按取(qu)消→,取(qu)消試驗(yan)過程;
在(zai)升(sheng)壓(ya)(ya)(ya)(ya)(ya)過(guo)(guo)(guo)程(cheng)中,如果高壓(ya)(ya)(ya)(ya)(ya)電(dian)(dian)流(liu)(liu)(liu)峰(feng)值(zhi)(zhi)超過(guo)(guo)(guo)“電(dian)(dian)流(liu)(liu)(liu)上限(xian)”值(zhi)(zhi)或低壓(ya)(ya)(ya)(ya)(ya)電(dian)(dian)流(liu)(liu)(liu)峰(feng)值(zhi)(zhi)超過(guo)(guo)(guo)“過(guo)(guo)(guo)流(liu)(liu)(liu)保護”值(zhi)(zhi)將認(ren)為被試品(pin)被擊(ji)穿,接觸器(qi)立刻分(fen)閘(zha)并顯(xian)示試驗(yan)(yan)結果,包(bao)括峰(feng)值(zhi)(zhi)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)、峰(feng)值(zhi)(zhi)電(dian)(dian)流(liu)(liu)(liu)、低壓(ya)(ya)(ya)(ya)(ya)電(dian)(dian)流(liu)(liu)(liu)等(deng),調壓(ya)(ya)(ya)(ya)(ya)器(qi)開(kai)始回(hui)零,回(hui)零完(wan)(wan)成試驗(yan)(yan)結束。如果在(zai)耐壓(ya)(ya)(ya)(ya)(ya)過(guo)(guo)(guo)程(cheng)中,高壓(ya)(ya)(ya)(ya)(ya)電(dian)(dian)流(liu)(liu)(liu)和低壓(ya)(ya)(ya)(ya)(ya)電(dian)(dian)流(liu)(liu)(liu)峰(feng)值(zhi)(zhi)沒有超設置(zhi)上限(xian)值(zhi)(zhi),認(ren)為被試品(pin)未(wei)擊(ji)穿,結果顯(xian)示區就顯(xian)示耐壓(ya)(ya)(ya)(ya)(ya)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)、高壓(ya)(ya)(ya)(ya)(ya)電(dian)(dian)流(liu)(liu)(liu)、低壓(ya)(ya)(ya)(ya)(ya)電(dian)(dian)流(liu)(liu)(liu)、絕緣電(dian)(dian)阻等(deng),調壓(ya)(ya)(ya)(ya)(ya)器(qi)開(kai)始回(hui)零,回(hui)零完(wan)(wan)成后接觸器(qi)分(fen)閘(zha)試驗(yan)(yan)結束。
4、自動試驗
自動(dong)試(shi)驗(yan)和(he)手動(dong)試(shi)驗(yan)的試(shi)驗(yan)過程類似,首先也進行回零檢查,確認后進入如下界(jie)面,如圖13:
按上方法切換到(dao)“開始”確定后(hou)進(jin)行(xing)試(shi)驗,與(yu)手(shou)動試(shi)驗不同(tong)之處就是升壓過(guo)程將自動升壓到(dao)“輸(shu)出電(dian)壓”值,然后(hou)進(jin)行(xing)計時(shi)。
升(sheng)壓(ya)過程為(wei)逼近方式(shi),首(shou)先(xian)升(sheng)到到接近目標值,然后再進行(xing)微調,保證高壓(ya)電(dian)壓(ya)值幾(ji)乎為(wei)輸(shu)出電(dian)壓(ya)值。
5、功能選(xuan)擇
按鍵盤上的(de)“設置”就進入功能界面,如圖(tu)14:
進(jin)入功能界(jie)面(mian)后(hou),可(ke)以選擇“時鐘設置”、“注意(yi)事項”等界(jie)面(mian)。
時鐘設(she)置:設(she)置時鐘的時間(jian),為打印報表提(ti)供時間(jian)依(yi)據。
注意(yi)事項(xiang)(xiang):為用戶提供一(yi)些操作規(gui)范和**注意(yi)事項(xiang)(xiang)。
6、打(da)印
按鍵盤“打印(yin)”按鍵可以打印(yin)試驗果,在此不贅述。
七、產品維護
1、開箱驗收時,應檢(jian)查主控回路接線是(shi)否(fou)松動(dong),調壓器電(dian)刷是(shi)否(fou)接觸良好。
2.、長期不用時,使(shi)用前應用500V兆歐(ou)表(biao)測量絕緣電阻,其阻值不低于0.5MΩ。
3、電源電壓應(ying)符合控制(zhi)箱(臺)說明書上的輸入(ru)電壓值要求。
4、本(ben)控(kong)制箱(臺)設有過(guo)電流(liu)保護,出廠已調整為額(e)定(ding)電流(liu)的50%。用于小負(fu)載時(shi),應根據(ju)被試品的額(e)定(ding)容(rong)量電流(liu)重(zhong)新設定(ding);
5、使用完畢后,應關(guan)好控制箱(臺(tai))門蓋,以保持內部清潔。
八、注(zhu)意事項
1、按(an)照您所(suo)進行的(de)(de)試驗接(jie)(jie)好工作(zuo)線路。試驗變壓(ya)器的(de)(de)外殼以及操作(zuo)系(xi)統的(de)(de)外殼必須可靠(kao)接(jie)(jie)地(di)。試驗變壓(ya)器的(de)(de)測(ce)量繞(rao)組的(de)(de)F端(duan)和外殼必須可靠(kao)接(jie)(jie)地(di)。
2、做(zuo)串級(ji)試(shi)驗(yan)時(shi),**級(ji)、第三級(ji)試(shi)驗(yan)變壓器(qi)的(de)低壓繞組(zu)成X端,測量(liang)繞組(zu)的(de)F端以及高(gao)(gao)壓繞組(zu)的(de)X端(高(gao)(gao)壓端)均(jun)接本級(ji)試(shi)驗(yan)變壓器(qi)具外(wai)殼。**級(ji)、第三級(ji)試(shi)驗(yan)變壓器(qi)的(de)外(wai)殼必須(xu)通過絕緣支架接地(di)。
接(jie)通(tong)電(dian)源前(qian),控制箱(臺)的調(diao)壓器必須調(diao)到零位后方可接(jie)通(tong)電(dian)源,合閘,開始升(sheng)壓。
3、從零(ling)開(kai)始(shi)(shi)勻(yun)速(su)旋(xuan)轉調壓(ya)(ya)器手輪(lun)升(sheng)(sheng)壓(ya)(ya)。升(sheng)(sheng)壓(ya)(ya)方式(shi)有:快(kuai)速(su)升(sheng)(sheng)壓(ya)(ya)法,即20s逐級升(sheng)(sheng)壓(ya)(ya)法;慢速(su)升(sheng)(sheng)壓(ya)(ya)法,即60s逐級升(sheng)(sheng)壓(ya)(ya)法;極慢速(su)升(sheng)(sheng)壓(ya)(ya)法供選用。電(dian)壓(ya)(ya)從零(ling)開(kai)始(shi)(shi)按一定的(de)(de)升(sheng)(sheng)壓(ya)(ya)方式(shi)和速(su)度上升(sheng)(sheng)到您(nin)所需(xu)的(de)(de)額(e)定試(shi)(shi)驗(yan)電(dian)壓(ya)(ya)的(de)(de)75%后,再以每(mei)秒2%額(e)定試(shi)(shi)驗(yan)電(dian)壓(ya)(ya)的(de)(de)速(su)度升(sheng)(sheng)到您(nin)所需(xu)的(de)(de)試(shi)(shi)驗(yan)電(dian)壓(ya)(ya),并(bing)密切(qie)注意(yi)測量(liang)儀表(biao)的(de)(de)及被試(shi)(shi)品(pin)的(de)(de)情況。升(sheng)(sheng)壓(ya)(ya)過(guo)程中或試(shi)(shi)驗(yan)過(guo)程中如發現測量(liang)儀表(biao)的(de)(de)指示及被試(shi)(shi)品(pin)情況異(yi)常,應立即降壓(ya)(ya),切(qie)斷電(dian)源(yuan),查明情況。
4、試驗完畢后,應在等調壓(ya)器返回至(zhi)零位(wei),然后切斷電(dian)源。
5、本產品不得超過額定(ding)參(can)數使用。
6、使(shi)用本(ben)產(chan)品做高壓試驗時,除熟(shu)悉本(ben)說明書外,還(huan)必須嚴格執行國(guo)家有關標準和操作(zuo)規程(cheng)(cheng)。可(ke)參照GB311.1 – 97《高壓輸(shu)變設(she)備的(de)絕緣配合,高壓試驗技術(shu)》;《電氣(qi)設(she)備預防性試驗規程(cheng)(cheng)》等。
7、控制箱(xiang)(臺(tai))應與試驗變壓器配套使用,控制箱(xiang)(臺(tai))的(de)使用方(fang)法,請詳細(xi)參閱控制器的(de)使用說明書(shu)。