一、WBYD2000變頻串聯諧振耐壓裝置基本原理
耐壓試驗是(shi)利(li)用電(dian)(dian)(dian)(dian)抗器的電(dian)(dian)(dian)(dian)感與(yu)被試品電(dian)(dian)(dian)(dian)容(rong)組成LC串聯回路,調節變(bian)頻(pin)電(dian)(dian)(dian)(dian)源輸(shu)出的電(dian)(dian)(dian)(dian)壓頻(pin)率,在被試品上(shang)獲得(de)高電(dian)(dian)(dian)(dian)壓,是(shi)當前高電(dian)(dian)(dian)(dian)壓試驗的一種(zhong)新方(fang)法,深受(shou)專家好(hao)評,在國內外已(yi)經得(de)到廣泛的使用。
根據諧(xie)振(zhen)(zhen)原(yuan)理,我們知道當電(dian)(dian)抗器(qi)(qi)L的(de)感(gan)抗值Xl與回(hui)(hui)路中(zhong)的(de)容抗值Xc相等時,回(hui)(hui)路達到諧(xie)振(zhen)(zhen)狀態,此時回(hui)(hui)路中(zhong)僅(jin)回(hui)(hui)路電(dian)(dian)阻(zu)R消耗有功功率(lv),而無(wu)功功率(lv)則在電(dian)(dian)抗器(qi)(qi)與試(shi)品電(dian)(dian)容之間來回(hui)(hui)振(zhen)(zhen)蕩,從而在試(shi)品上(shang)產生高壓。
二、WBYD2000變頻串聯諧振耐壓裝置系統構成
全套(tao)試(shi)驗(yan)系統由調頻電源主機(ji)、電抗(kang)器、分壓器、激勵(li)變壓器和補償電容器(可選(xuan)器件)組(zu)成,接入(ru)被(bei)試(shi)品后組(zu)成一個諧振(zhen)系統進行交流耐壓實驗(yan)。
主機: 就(jiu)是(shi)一臺幅值和頻(pin)率可調(diao)的正弦波交流調(diao)頻(pin)電(dian)源(yuan),給諧振回路提(ti)供激(ji)勵源(yuan),同(tong)時(shi)提(ti)供電(dian)壓顯示(shi)、電(dian)流顯示(shi)、計時(shi)、保護(hu)、報警等功能。
電(dian)抗器(qi)(qi):就是(shi)一個大電(dian)感線(xian)圈,與被試(shi)品(pin)(相當于電(dian)容)構成回路,可(ke)配(pei)置電(dian)抗器(qi)(qi)多節電(dian)抗器(qi)(qi),使(shi)用(yong)時通過不同的串(chuan)聯(lian)、并(bing)聯(lian)組(zu)合、實現(xian)不同的電(dian)感量以適用(yong)不同的試(shi)驗條件。
分壓(ya)器(qi):內(nei)部通(tong)過電(dian)容器(qi)分壓(ya),從(cong)試品(pin)上高電(dian)壓(ya)分得低電(dian)壓(ya)供主機測量、控制使用。
勵磁(ci)變(bian)壓器:隔離(li)主(zhu)(zhu)機電源(yuan)(yuan)與諧振回路電源(yuan)(yuan),并升高主(zhu)(zhu)機的輸出(chu)電壓。
補(bu)償電(dian)(dian)容(rong)器(qi):當試(shi)品(pin)電(dian)(dian)容(rong)量很小時(shi),如果要(yao)實現系(xi)統諧(xie)振可(ke)能要(yao)求的電(dian)(dian)源頻率超出試(shi)驗標準的規(gui)定,可(ke)在試(shi)品(pin)上(shang)并(bing)聯(lian)一(yi)個補(bu)償電(dian)(dian)容(rong),以實現試(shi)驗要(yao)求,稱(cheng)此電(dian)(dian)容(rong)器(qi)為(wei)補(bu)償電(dian)(dian)容(rong)器(qi)。
三、WBYD2000變頻串聯諧振耐壓裝置主要技術性能
功率(lv)電源電壓(ya):AC380V±10%、50Hz;
儀器電源:220V±10%、50Hz;
諧振輸出容量:200kVA;
儀器額(e)定電壓(ya):0~200kV;
輸出(chu)頻率范(fan)圍:30~300Hz;
輸出電壓(ya)波形:正弦波,波形畸變率<0.5%;
頻率(lv)調節靈敏度(du):0.1Hz,不穩定度(du)≤0.05%;
系(xi)統(tong)噪聲:≤60db;
9、系統測(ce)量精度(du):<1級;
10.輸出電壓不穩(wen)定:<0.5%;
11.保護響應時間:1us;
12.電感非線(xian)性度:≤0.05%;;
13.滿(man)功率輸出下,連續工作時(shi)間為60min
14.環境溫度:-15℃~+50℃;
15.相對濕(shi)度:≤90%RH;
16.海拔(ba)高度:≤2000米。
四、WBYD2000變頻串聯諧振耐壓裝置面板及部件名稱
五、WBYD2000變頻串聯諧振耐壓裝置操作步驟
1、正確連線,檢查無誤后方可(ke)送電。
必(bi)要(yao)時工作電源的(de)跳(tiao)過現場漏電保安器,以免(mian)不必(bi)要(yao)的(de)跳(tiao)閘。
2、打開(kai)電源開(kai)關,主機開(kai)始工作,液(ye)晶屏顯示版權(quan)頁,該頁標明本裝置的軟件版本號(hao)。
觸按確認鍵,進(jin)入系統菜單(dan),該主(zhu)菜單(dan)下有(you):試驗(yan)方(fang)案、開始試驗(yan)、試驗(yan)幫助、系統設置、實用(yong)工具和試驗(yan)記錄(lu)等六個子菜單(dan)項。
3、 系(xi)統設(she)(she)置菜(cai)(cai)單(dan)下有電(dian)抗(kang)(kang)器電(dian)感(gan)、日期時間設(she)(she)置和(he)采(cai)樣(yang)系(xi)數(shu)(shu)設(she)(she)置等(deng)三個(ge)子菜(cai)(cai)單(dan)項。按(an)上(shang)下鍵(jian),上(shang)下移動光標系(xi)統參數(shu)(shu)設(she)(she)置菜(cai)(cai)單(dan)項,觸按(an)確定鈕后,進入系(xi)統參數(shu)(shu)設(she)(she)置菜(cai)(cai)單(dan),可以分別(bie)設(she)(she)定電(dian)抗(kang)(kang)器的(de)電(dian)感(gan)—H、-年-月-日、-時-分-秒和(he)電(dian)壓和(he)電(dian)流的(de)采(cai)樣(yang)系(xi)數(shu)(shu)也(ye)就是(shi)采(cai)樣(yang)倍率,設(she)(she)定完成(cheng)后,觸按(an)返(fan)還(huan)鍵(jian)返(fan)回上(shang)**菜(cai)(cai)單(dan)。
電抗器電感(gan)量(liang)的設定:按確定鍵(jian)(jian)選擇(ze)到此項(xiang),按左(zuo)右鍵(jian)(jian)移動光標(biao)需要改變的數(shu)位,按上下鍵(jian)(jian)改變數(shu)值,達(da)到所要達(da)到的數(shu)值按確定鍵(jian)(jian)確認。
日期時間(jian)的(de)設定(ding):按(an)(an)確定(ding)鍵(jian)選擇到此項,按(an)(an)左右鍵(jian)移動光(guang)標需要改(gai)(gai)變的(de)數位,按(an)(an)上下鍵(jian)改(gai)(gai)變數值,按(an)(an)照所要設置(zhi)的(de)年(nian)月日時間(jian)數值按(an)(an)確定(ding)鍵(jian)確認(ren)。
采(cai)樣系數(shu)的設(she)定(ding):按(an)確定(ding)鍵選擇到(dao)高壓/電流采(cai)樣系數(shu)項,此項為電壓或電流采(cai)樣倍率的設(she)定(ding)。一(yi)般出廠前設(she)定(ding)好(hao)了。如需修改,要輸入密碼。(密碼廠家(jia)與設(she)備一(yi)起(qi)提供一(yi)般設(she)定(ding)為:188888)
警告:系統默(mo)認上一(yi)次(ci)電(dian)抗器電(dian)感(gan)、日期時間(jian)和采樣系數設(she)定(ding)值。如果(guo)需改(gai)變要(yao)重新設(she)定(ding)。電(dian)抗器電(dian)感(gan)量(liang)設(she)定(ding)值與實際使(shi)用的電(dian)抗器電(dian)感(gan)量(liang)不(bu)(bu)對(dui),會(hui)導(dao)致試(shi)驗報告中的被試(shi)品(pin)電(dian)容量(liang)不(bu)(bu)準(zhun)。其他并不(bu)(bu)會(hui)影響。采樣系數設(she)置不(bu)(bu)正確,會(hui)導(dao)致顯示電(dian)壓電(dian)流(liu)不(bu)(bu)準(zhun)將很(hen)有可能會(hui)對(dui)被試(shi)品(pin)或試(shi)驗設(she)備造成損壞。
4、試(shi)(shi)驗方案菜單(dan)下(xia)有預(yu)置(zhi)保(bao)護電流、找頻(pin)(pin)(pin)(pin)起(qi)始(shi)(shi)頻(pin)(pin)(pin)(pin)率(lv)、找頻(pin)(pin)(pin)(pin)結(jie)束(shu)頻(pin)(pin)(pin)(pin)率(lv)、預(yu)定(ding)(ding)起(qi)始(shi)(shi)功(gong)率(lv)四個子菜單(dan)項,分別設(she)定(ding)(ding)本次試(shi)(shi)驗的保(bao)護電流、找頻(pin)(pin)(pin)(pin)起(qi)始(shi)(shi)頻(pin)(pin)(pin)(pin)率(lv)、找頻(pin)(pin)(pin)(pin)結(jie)束(shu)頻(pin)(pin)(pin)(pin)率(lv)、輸出(chu)起(qi)始(shi)(shi)功(gong)率(lv),全(quan)部設(she)定(ding)(ding)完成(cheng)后,觸按返還鍵進入預(yu)置(zhi)試(shi)(shi)驗電壓和預(yu)置(zhi)試(shi)(shi)驗時間設(she)置(zhi)菜單(dan)。
可(ke)以分3段時間(jian)設(she)(she)置試(shi)(shi)驗(yan)(yan)電(dian)壓(ya)和試(shi)(shi)驗(yan)(yan)時間(jian), 實(shi)際試(shi)(shi)驗(yan)(yan)時,若設(she)(she)定為(wei)自動(dong)試(shi)(shi)驗(yan)(yan), 裝(zhuang)置將按(an)設(she)(she)定的3段電(dian)壓(ya)及時間(jian),按(an)順(shun)序(xu)分別(bie)加壓(ya), 全部完成后自動(dong)退出.
如果**段(duan)電(dian)壓(ya)(ya)(ya)設(she)為0, 或時間設(she)為0, 那(nei)么執(zhi)行完(wan)**段(duan)試(shi)驗(yan)電(dian)壓(ya)(ya)(ya)加(jia)壓(ya)(ya)(ya)后退(tui)出試(shi)驗(yan), 只(zhi)加(jia)壓(ya)(ya)(ya)**段(duan)設(she)定的電(dian)壓(ya)(ya)(ya).
如果第三段電壓設(she)(she)為(wei)0, 或(huo)時間設(she)(she)為(wei)0, 不執行第三段加壓.
試驗方案設置(zhi)的設定:在試驗電壓(ya)項中,按(an)確定單(dan)鈕(niu),移動左(zuo)右光標到(dao)需(xu)要改(gai)變的數(shu)(shu)位,按(an)上(shang)下(xia)單(dan)鈕(niu)以改(gai)變當(dang)(dang)前數(shu)(shu)位的數(shu)(shu)值(zhi)大小(xiao),觸按(an)返回(hui)鈕(niu)完成(cheng)當(dang)(dang)前數(shu)(shu)位的數(shu)(shu)值(zhi)設定,依(yi)次選擇下(xia)一(yi)項數(shu)(shu)值(zhi)的設定,直至分別完成(cheng)試驗時間、起(qi)始(shi)頻率、起(qi)始(shi)功率的設置(zhi),方可(ke)完成(cheng)本次試驗的試驗方案設置(zhi)的設定。
出(chu)廠默認值:試驗電壓 20kV、加壓時間(jian) 2min、激勵強度(du) 2%、輸(shu)出(chu)電流20A、頻率范(fan)圍30-300Hz。
5、實用工具菜單下有
頻率計(ji)算(suan):在(zai)實驗前可對諧振頻率進行計(ji)算(suan)。只需輸入具體參與(yu)試(shi)驗的電(dian)感(gan)、電(dian)容值(zhi)并(bing)按確定鍵試(shi)驗頻率即直接生成。
6、開始(shi)試驗菜單下有自動(dong)試驗模式和手動(dong)試驗模式兩種(zhong)子菜單可供選擇。
按確認(ren)鍵(jian)進入所選試(shi)驗步驟(zou).
自(zi)動試(shi)驗模(mo)式的(de)操作(zuo):選中自(zi)動試(shi)驗模(mo)式后,觸按(an)菜(cai)單(dan)鈕進入正在(zai)自(zi)動尋(xun)找(zhao)諧(xie)振(zhen)(zhen)點(dian)菜(cai)單(dan)項(xiang),裝(zhuang)置在(zai)設定(ding)的(de)頻(pin)率范圍(wei)內自(zi)動尋(xun)找(zhao)諧(xie)振(zhen)(zhen)點(dian)(如果被試(shi)品電(dian)容C和電(dian)抗器電(dian)感L的(de)實際諧(xie)振(zhen)(zhen)頻(pin)率不(bu)在(zai)設定(ding)的(de)頻(pin)率范圍(wei)內,將找(zhao)不(bu)到諧(xie)振(zhen)(zhen)點(dian),此時(shi)根(gen)據需要調(diao)整(zheng)頻(pin)率范圍(wei)或調(diao)整(zheng)被試(shi)品回(hui)路的(de)LC參(can)數)。當找(zhao)到諧(xie)振(zhen)(zhen)點(dian)時(shi),會有(you)聲音提(ti)示(shi)。
找到諧振點后,裝置自(zi)動(dong)進入正在自(zi)動(dong)升壓菜單項,當升到試驗(yan)電壓設定的(de)電壓時,裝置停止加壓。
當(dang)裝置(zhi)升到(dao)試(shi)(shi)驗(yan)(yan)電(dian)壓設定的(de)電(dian)壓時,設備(bei)停止(zhi)加壓,自(zi)動進(jin)入正在加壓試(shi)(shi)驗(yan)(yan)菜單(dan)項,并自(zi)動記(ji)錄試(shi)(shi)驗(yan)(yan)的(de)加壓時間(jian),當(dang)加壓時間(jian)到(dao)達設定時間(jian)時,設備(bei)逐步降壓退出試(shi)(shi)驗(yan)(yan),完成本次試(shi)(shi)驗(yan)(yan),進(jin)入試(shi)(shi)驗(yan)(yan)結束菜單(dan)項。并可選擇(ze)保存試(shi)(shi)驗(yan)(yan)數據或打印試(shi)(shi)驗(yan)(yan)數據。
試(shi)驗(yan)時(shi)間的一行顯示末端,會顯示[一段(duan)]或(huo)(huo)[二(er)段(duan)]或(huo)(huo)[三段(duan)]字樣(yang),表示當前正在進行的加壓試(shi)驗(yan)是(shi)預置(zhi)的一段(duan),二(er)段(duan)或(huo)(huo)三段(duan).
手動(dong)試驗模式的(de)操作:選中(zhong)手動(dong)試驗模式后觸按確定鈕(niu),進入正在試驗菜單(dan)項;手動(dong)按調(diao)(diao)頻(pin)(pin)(pin)鈕(niu),對應的(de)光標隨(sui)之改變到(dao)輸(shu)出頻(pin)(pin)(pin)率(lv)(lv)(lv)項,可以通過(guo)上下(xia)(xia)左右鍵改變頻(pin)(pin)(pin)率(lv)(lv)(lv)大小使其(qi)試驗電(dian)壓逐(zhu)步(bu)升(sheng)高(gao),當升(sheng)到(dao)*高(gao)電(dian)壓時,繼續(xu)向上或向下(xia)(xia)調(diao)(diao)整頻(pin)(pin)(pin)率(lv)(lv)(lv)按鈕(niu),直至(zhi)試驗電(dian)壓開始下(xia)(xia)降;這時反調(diao)(diao)頻(pin)(pin)(pin)率(lv)(lv)(lv),試驗電(dian)壓又(you)逐(zhu)步(bu)回(hui)升(sheng),上下(xia)(xia)回(hui)調(diao)(diao)頻(pin)(pin)(pin)率(lv)(lv)(lv),從頻(pin)(pin)(pin)率(lv)(lv)(lv)的(de)高(gao)位到(dao)低位逐(zhu)位調(diao)(diao)整*高(gao)電(dian)壓值(zhi)時的(de)頻(pin)(pin)(pin)率(lv)(lv)(lv)就是(shi)當前的(de)諧振頻(pin)(pin)(pin)率(lv)(lv)(lv)。
找(zhao)到諧振點后(hou),手動按電壓鈕,光標到了輸出功率,隨之按上下(xia)鍵增加輸出功率,試(shi)(shi)(shi)驗(yan)(yan)(yan)電壓也逐步升高,當(dang)升到試(shi)(shi)(shi)驗(yan)(yan)(yan)電壓設(she)定電壓值(zhi)時,裝置停止加壓,并有屏幕(mu)顯示(shi)提(ti)(ti)示(shi)和聲音提(ti)(ti)示(shi);自(zi)(zi)動進入正(zheng)在加壓試(shi)(shi)(shi)驗(yan)(yan)(yan)菜單項(xiang),并自(zi)(zi)動記錄試(shi)(shi)(shi)驗(yan)(yan)(yan)的加壓時間,當(dang)到達(da)加壓時間設(she)定時間時,設(she)備逐步降壓退出試(shi)(shi)(shi)驗(yan)(yan)(yan),完成(cheng)本次試(shi)(shi)(shi)驗(yan)(yan)(yan),進入試(shi)(shi)(shi)驗(yan)(yan)(yan)結束菜單項(xiang)。
注意:在調(diao)節頻(pin)率調(diao)整鈕(niu)的(de)過程(cheng)中,觸(chu)按左右鈕(niu),可以改變(bian)頻(pin)率調(diao)節的(de)速度(du)實(shi)現(xian)粗細調(diao)的(de)切(qie)換(huan)(huan)。在調(diao)節電壓調(diao)整鈕(niu)的(de)過程(cheng)中,向下觸(chu)按左右鈕(niu),可以改變(bian)電壓的(de)升降的(de)速度(du)實(shi)現(xian)粗細調(diao)的(de)切(qie)換(huan)(huan)。觸(chu)按調(diao)頻(pin)、調(diao)壓鈕(niu),實(shi)現(xian)調(diao)頻(pin)與調(diao)壓間的(de)切(qie)換(huan)(huan)。
7、進入試驗記(ji)錄查詢菜單項,查詢以往和當(dang)前(qian)試驗數據(ju)(ju)。選擇上下鍵翻看前(qian)一組(zu)數據(ju)(ju)后一組(zu)數據(ju)(ju);選擇左右鍵可選擇打印或(huo)刪除當(dang)前(qian)頁(ye)的內容(rong)。
125/456為(wei)試驗數(shu)(shu)(shu)(shu)據庫(ku)(ku)指針,分子是試驗數(shu)(shu)(shu)(shu)據的(de)在數(shu)(shu)(shu)(shu)據庫(ku)(ku)的(de)順(shun)序(xu)數(shu)(shu)(shu)(shu),分母是當前的(de)數(shu)(shu)(shu)(shu)據總數(shu)(shu)(shu)(shu),*多可儲(chu)存999組試驗數(shu)(shu)(shu)(shu)據。
8、裝置和(he)試(shi)驗(yan)(yan)(yan)狀(zhuang)態菜單(dan)提(ti)示(shi):設(she)(she)備(bei)(bei)的使(shi)用(yong)和(he)升壓和(he)耐(nai)壓試(shi)驗(yan)(yan)(yan)過程(cheng)中,如果出現(xian)影響試(shi)驗(yan)(yan)(yan)設(she)(she)備(bei)(bei)、被試(shi)驗(yan)(yan)(yan)設(she)(she)備(bei)(bei)以及操作人的**情況,設(she)(she)備(bei)(bei)可能(neng)出現(xian)自動保護轉(zhuan)臺,并在屏幕有相應的提(ti)示(shi)。
不能諧(xie)(xie)振(zhen):如果諧(xie)(xie)振(zhen)點(dian)不在諧(xie)(xie)振(zhen)頻率設置的(de)范圍(wei)內;系統連(lian)線不正(zheng)確等(deng)現象,裝置將找不到諧(xie)(xie)振(zhen)點(dian),這時裝置和試驗狀態菜單中(zhong)的(de)不能諧(xie)(xie)振(zhen)項被反白并閃(shan)爍。
輸出(chu)保(bao)護:如果(guo)裝(zhuang)(zhuang)置的(de)電源(yuan)輸出(chu)電流大(da)于輸出(chu)保(bao)護設定的(de)電流值,裝(zhuang)(zhuang)置自動保(bao)護,這時裝(zhuang)(zhuang)置和試驗狀(zhuang)態(tai)菜單中的(de)輸出(chu)保(bao)護項被反白并閃爍(shuo)。
試(shi)驗中止:如果在試(shi)驗升壓或加(jia)壓過程出現閃絡現象,裝置自(zi)動保護(hu),這時裝置和試(shi)驗狀態菜單中的輸出保護(hu)項被(bei)反白并(bing)閃爍。
9、試(shi)驗幫助內容包括五大(da)項分(fen)別為(wei):1.版(ban)本(ben)信(xin)息2.接線示意3.使(shi)用說明4.常見問題5.參(can)考資料(liao).如常見問題FAQ分(fen)五幅畫(hua)面顯(xian)示、各種被(bei)試(shi)品(pin)電力電纜、變壓器、發電機(ji)電容參(can)數的查詢(xun):
接線示意圖:
10、設(she)備出廠(chang)(chang)(chang)參(can)數設(she)置是生產廠(chang)(chang)(chang)家的出廠(chang)(chang)(chang)設(she)置參(can)術和校驗(yan)參(can)數,不(bu)適當的設(she)置和修改(gai)會影(ying)響(xiang)設(she)備性(xing)(xing)能和高壓試驗(yan)的**性(xing)(xing),未經廠(chang)(chang)(chang)家授權密碼,無法修改(gai)。
警告:正常試驗狀(zhuang)態下,按(an)返回鍵即可中止試驗。中止或結(jie)束試驗后(hou),應分離(li)刀閘切斷電源(yuan)。在升壓或加壓過程中,非緊(jin)急情況,不(bu)要(yao)按(an)下急停鍵。
六、本說明書(shu)的專(zhuan)屬名(ming)詞的定義
自(zi)動(dong)試(shi)驗:高壓(ya)試(shi)驗全過程(cheng)由主機按程(cheng)序和預置參數自(zi)動(dong)完成。
自動(dong)調諧:調諧由(you)主機按程(cheng)序自動(dong)完成,升壓手動(dong)完成。
手動(dong)試驗:尋找諧振點和升壓(ya)均為(wei)手動(dong),通(tong)過面板旋(xuan)鈕完成(cheng)。
系統參數(shu)設(she)置(zhi)是指對設(she)備部件參數(shu)的(de)設(she)置(zhi)。
試(shi)驗(yan)參數設置是指對(dui)試(shi)驗(yan)過程(cheng)參數的設置。
試驗模式選擇(ze)(ze)是指對試驗模式的選擇(ze)(ze)。
試驗結果查(cha)詢是指對試驗數(shu)據的查(cha)詢。
分壓(ya)器變(bian)比是指(zhi)對分壓(ya)器的分壓(ya)比設置。
電(dian)抗(kang)(kang)器電(dian)感是指對(dui)電(dian)抗(kang)(kang)器電(dian)抗(kang)(kang)值的(de)設置。
激勵(li)(li)變(bian)變(bian)比是(shi)指對勵(li)(li)磁變(bian)壓(ya)器(qi)的變(bian)比設置(zhi)。
設置(zhi)電壓是高壓試驗時的保護電壓設置(zhi)。
試驗(yan)電壓(ya)是高(gao)壓(ya)試驗(yan)時的(de)試驗(yan)電壓(ya)。
加壓(ya)(ya)時(shi)間(jian)是施加試驗電壓(ya)(ya)的時(shi)間(jian)。
激(ji)勵強(qiang)度是(shi)指主機電源輸出(chu)的大(da)小(xiao)。
輸(shu)出(chu)電流是主(zhu)機電源(yuan)的輸(shu)出(chu)電流。
頻率范(fan)圍是(shi)試(shi)驗的(de)頻率范(fan)圍。
自(zi)動(dong)試驗(yan)模式是指試驗(yan)過(guo)程全部自(zi)動(dong)完成。
自動調諧(xie)模式是指(zhi)自動尋找諧(xie)振點后,手動加(jia)壓完(wan)成試驗。
手動試(shi)驗模式(shi)全部(bu)由人工完(wan)成(cheng)試(shi)驗過程。
未接(jie)地線主機電源(yuan)為(wei)接(jie)地。
不能(neng)諧振未能(neng)找到諧振點。
輸出(chu)保護(hu)主機電源輸出(chu)電流大于整定電流。
試驗中(zhong)止指在升(sheng)壓或加壓過程裝置(zhi)自動保護。
設(she)(she)備出(chu)廠(chang)參數設(she)(she)置是廠(chang)家對設(she)(she)備有(you)關參數的設(she)(she)置。
確認(ren)鍵:確認(ren)當前操作。
返回鍵:返回上**菜單。
七、變頻電(dian)源技術參數:
1.額定輸出容量:15kvA;
2.儀器電源:220v±10% 50Hz;
功率電源:380v±10% 50Hz;
3.額定輸入電流:39.5A;
4.額定(ding)(ding)輸出電壓(ya):0-340v可(ke)調(diao)、單(dan)相、輸出電壓(ya)不(bu)穩(wen)定(ding)(ding)度0.05%;
5.額定輸出(chu)電流:44A;
6.頻(pin)率調節(jie)范圍:25~320Hz;
7.額定容量(liang)下連續運行為規定工作時間下*高溫升≤60K;
8.顯示(shi)以下參數:
a.經(jing)變頻(pin)輸出的頻(pin)率、電壓、電流;
b.過壓(ya)保(bao)護電壓(ya)值(zhi),并可(ke)任意整定,當(dang)成套裝(zhuang)置的(de)輸(shu)出電壓(ya)值(zhi)達到保(bao)護整定時,可(ke)自(zi)動切除成套裝(zhuang)置;
c.過流保護(hu):當(dang)調頻電(dian)源(yuan)的輸出電(dian)流達(da)到保護(hu)整定值時(shi),可(ke)自動(dong)切除(chu)成套裝置;
d.擊穿保護:當高壓側發生對地(di)閃絡(luo)時,可自動切除成套(tao)裝置(zhi),裝置(zhi)帶有隔離(li)裝置(zhi),可確保設備(bei)和人身不受損害(hai);
e.具有全電壓輸出保護,在調(diao)壓過(guo)程中,一旦調(diao)壓失控,調(diao)頻電源立即(ji)閉鎖(suo);
9.可實現以下操(cao)作(zuo):
a.頻率的調節,上升和(he)下降(jiang)頻率調節分粗(cu)調和(he)細調兩種,并可自(zi)動尋找試(shi)驗(yan)諧(xie)(xie)振點,保證諧(xie)(xie)振頻率在整(zheng)個試(shi)驗(yan)過程中不(bu)發(fa)生漂移;
b.帶有設置電(dian)壓、設置時(shi)間,電(dian)壓自動(dong)上(shang)升(sheng)到設置值而(er)停止并自動(dong)計時(shi);
c.帶有各種保(bao)護功能的整定(ding)(ding)按鈕,可在面板上對(dui)各種保(bao)護值進行整定(ding)(ding);
d.帶(dai)有手動(dong)試驗功能(neng)和(he)自動(dong)試驗功能(neng);
e.帶有(you)試驗數據(ju)打(da)印功能(neng)。
八、勵磁變壓(ya)器技術參(can)數(shu):
1.結構(gou)形式(shi):干式(shi);
2.額定容量(liang):15kVA;
3.輸入電(dian)壓:0~340V;
4.輸出電壓:四組并(bing)聯3.75KV;四組串(chuan)聯15KV;二串(chuan)二并(bing)7.5KV;
5.輸出電流:四組并聯(lian)4A;四組串聯(lian)1A;二(er)串二(er)并2A;
6.工作頻率范圍:30~300Hz;
勵磁變(bian)壓器的接線(xian)端子(zi),如圖所示:
1.輸(shu)出(chu)端(duan)尾(wei)—與接地端(duan)連接。
2.輸出端(duan)頭—與(yu)電(dian)抗(kang)器(qi)連(lian)接(jie)。
3.接(jie)地端—與(yu)變頻電源、分壓(ya)器及被試品共同接(jie)地。
4.輸入端(duan)—接調頻電源(yuan)功率(lv)輸出端(duan)。
九、諧振(zhen)電(dian)抗器技術參(can)數:
額定容(rong)量:55KVA;
額定電壓:55kV;
額定電(dian)流:1.5A;
電 感 量:160H;
品質因數(shu):Q≥30
采(cai)用環氧干(gan)式。
7.接線端了如圖所示(shi):
a.高(gao)(gao)壓側(ce)接(jie)線端子—與被試品高(gao)(gao)壓端連接(jie)。
b.低壓側接線端(duan)子(zi)—與勵磁變輸出端(duan)連接。
c.多臺(tai)電抗器串(chuan)聯(lian)時上節的低壓側與(yu)下節高(gao)壓側連(lian)(lian)接(jie)。諧振電抗器采用多臺(tai)串(chuan)聯(lian)或并聯(lian)的連(lian)(lian)接(jie)方式。
8.額定容量下連續運行(xing)為規定工作時間下,電抗器對空氣(qi)的溫升不大于60K;
9.性能(neng)及(ji)特點:電抗器(qi)設計干式、環(huan)氧澆鑄(zhu),電抗器(qi)可以(yi)自由方便疊裝(zhuang)。環(huan)氧樹脂絕緣筒外(wai)殼,具有足夠的電氣、機械強度,必要的散熱能(neng)力(li)以(yi)及(ji)油熱脹冷縮的裕(yu)度。外(wai)殼上下蓋板,顏色為橘紅色。
十(shi)、電容分壓器技術參數:
額定電壓:200kV;
工作頻率:30~300Hz;
分壓比:2000:1;
分壓比(bi)誤(wu)差:1%;
電容(rong)分壓器接線(xian)端子(zi)如(ru)圖(tu)所(suo)示:
高(gao)(gao)壓(ya)端—與電抗器高(gao)(gao)壓(ya)側及被(bei)試品(pin)高(gao)(gao)壓(ya)側相連。
測量插(cha)座(zuo)—采用(yong)專配的測量電纜與控制箱背板(ban)測量輸入端連接。
接地(di)端—采(cai)用專配接地(di)線按接線圖指示接地(di)。
4.性能及特點:
a.額定(ding)電(dian)壓(ya)下可連續運行2小時。
b.在30~300Hz范(fan)圍內,其精(jing)度和穩定(ding)度保持不變。
c.在20℃溫度(du)下電容分(fen)壓(ya)器介質(zhi)損耗值≤0.0025
d.電容分(fen)壓(ya)器配有支撐底(di)架(jia),具有足(zu)夠的穩定(ding)性。
e.電(dian)壓測量(liang)通過專用測試引線引至(zhi)調頻電(dian)源進行測量(liang)。
試驗接線圖:
110kv主變(bian)、GIS試驗接線
35kv電(dian)纜試驗接(jie)線圖
10kv電纜試驗(yan)接(jie)線(xian)圖
十(shi)二、設備保(bao)存(cun)和(he)維護
1、存(cun)放于干燥、清潔場(chang)地(di),防止雨(yu)水、灰塵進入(ru)部(bu)(bu)件(jian)內部(bu)(bu);
2、如若長期(qi)不(bu)(bu)使(shi)(shi)用(yong),正常天氣至少(shao)2個月應通電一次時(shi)間不(bu)(bu)少(shao)于半(ban)小時(shi),雨季及潮濕(shi)期(qi)應每隔一個月通電一次,通電時(shi)間半(ban)小時(shi),以驅(qu)除設(she)備內的(de)潮氣防止(zhi)電子元器(qi)件(jian)的(de)銹(xiu)蝕,影響正常使(shi)(shi)用(yong)。
3、定期檢查裝置各(ge)部件,確(que)保各(ge)接頭緊(jin)固(gu)無松動;
4、更(geng)換打(da)(da)印紙(zhi)(zhi),機器采用(yong)熱敏(min)打(da)(da)印紙(zhi)(zhi)并且是前(qian)換紙(zhi)(zhi)式(shi)當需要換紙(zhi)(zhi)時(shi)只要按(an)POST鍵鈕打(da)(da)印紙(zhi)(zhi)艙門就會打(da)(da)開可以將(jiang)新打(da)(da)印紙(zhi)(zhi)裝入;
十三、常見(jian)故障(zhang)排除
故障現象
|
發 生 原 因
|
排 除 方(fang) 法
|
找(zhao)不到諧振點
|
接線有誤。
輸出開(kai)關未開(kai),;
3、做(zuo)GIS時PT二次回(hui)路未打開;
4、試品Q值太低;
5、起始激勵(li)功率太低;
6、試驗(yan)回路(lu)有短(duan)路(lu)現象(xiang);
7、找頻范圍不(bu)對。
|
退出試驗(yan)狀(zhuang)態,合上輸出開關,檢查接線;打開PT二(er)次回路;
調(diao)高起(qi)始功(gong)率(∠30%);
用(yong)兆歐表測量試品(pin)絕(jue)緣
重新(xin)設(she)置找頻范(fan)圍
|
諧振后,電壓升不上去
|
1、試品Q值(zhi)太低;
2、激勵電壓不(bu)夠;
3、電抗器(qi)底部有鐵磁物體;
4、3次諧波諧振。
|
檢查(cha)試品;
改(gai)變激勵變壓器繞(rao)組接法,提高勵磁電壓
絕緣筒架高電抗器或離開鐵磁物體。
|
主機自動復位(wei)
|
供電電源容量(liang)不夠(gou);
電源引(yin)線過長或線徑過小;
接頭處接觸**;
供電電壓波動;
按鍵死(si)接觸。
|
增加(jia)供電(dian)電(dian)源容量(liang);
換較(jiao)粗導(dao)線,減小(xiao)導(dao)線長度(du);
檢查接頭;
減小供電(dian)電(dian)壓波動。
|
開機后線路跳閘
|
線路漏電保護(hu)器較(jiao)為敏(min)感;
空氣開關容量不(bu)夠。
|
跨過漏電保護器或(huo)空氣開(kai)關(guan)的接線;
改換較大(da)容量的空氣開關。
|
電壓跌落
|
試品(pin)放(fang)電(dian)或擊穿
|
檢查試品(pin)
|
輸出短(duan)路(lu)
|
電流超過(guo)本機限流值。
|
檢查接線和試(shi)品。
|
試品電壓不(bu)準
|
分壓比設置錯誤或分壓器信(xin)號傳(chuan)輸有(you)問題。
|
重設(she)分壓(ya)比或檢查(cha)分壓(ya)器接線。
|
電壓閃變(bian)
|
試驗電(dian)壓劇烈波(bo)動,變化率超(chao)過(guo)本機限定值。
|
檢查(cha)供電(dian)電(dian)源(yuan)電(dian)壓穩定性或試品(pin)參數的變(bian)化。
|
回路無電流
|
|
檢(jian)查接線和試品。
|
未接(jie)好(hao)地線
|
|
檢查(cha)接地(di)線和地(di)樁,按說明書要求連(lian)接。
|
試品過電壓(ya)
|
手動升壓太(tai)快或(huo)失控。
|
改變調壓步距(ju)或改用自動升壓 。
|
系統不諧振(zhen)
|
接線有(you)誤(wu)或(huo)試品(pin)Q值太低。
|
檢查(cha)接(jie)線和試品
|
十四、常用設備(bei)資(zi)料參(can)考
交聯聚乙烯(xi)電纜(lan)單(dan)位長度電容量
電纜導體截面積(平(ping)方(fang)毫米)
|
電(dian) 容 (μ/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
1×35
|
0.212
|
0.173
|
0.152
|
|
|
1×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
1×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
1×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
1×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
1×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
1×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
1×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
1×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
1×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
1×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
1×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
2、交(jiao)聯聚(ju)乙(yi)烯電纜單位長度(du)電容(rong)量
電纜(lan)導(dao)體截面(mian)積(ji)(平方毫米)
|
電 容(rong) (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
3×35
|
0.212
|
0.173
|
0.152
|
|
|
3×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
3×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
3×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
3×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
3×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
3×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
3×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
3×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
3×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
3×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
3×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
3、交聯(lian)聚乙烯(xi)電(dian)纜單位長度電(dian)容量
電(dian)纜導體截面積(平方毫米(mi))
|
電 容(rong) (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
64/110kV
|
128/220kV
|
3×240
|
0.129
|
|
3×300
|
0.139
|
|
3×400
|
0.156
|
0.118
|
3×500
|
0.169
|
0.124
|
3×630
|
0.188
|
0.138
|
3×800
|
0.214
|
0.155
|
3×1000
|
0.231
|
0.172
|
3×1200
|
0.242
|
0.179
|
3×1400
|
0.259
|
0.190
|
3×1600
|
0.273
|
0.198
|
3×1800
|
0.284
|
0.297
|
3×2000
|
0.296
|
0.215
|
3×2200
|
|
0.221
|
3×2500
|
|
0.232
|
4、60kV級全絕緣(yuan)變(bian)壓器的電容(pF)
類 型
|
變 壓(ya) 器 容 量(liang) kVA
|
630
|
2000
|
3150
|
6300
|
8000
|
1600
|
高壓(ya)-地
|
2700
|
4100
|
4600
|
5900
|
7000
|
8200
|
低壓-地(di)
|
4200
|
6600
|
7900
|
10000
|
11000
|
15300
|
對于(yu)表中沒有的(de)產品(pin),可根據表中的(de)上(shang)、下(xia)容量近似(si)地估算。同容量的(de)雙繞組(zu)變壓(ya)器,其繞組(zu)電容要比三(san)繞組(zu)產品(pin)小(xiao)。
5、110kV級中性點分(fen)級絕緣(yuan)變壓器的電容(pF)
類 型
|
變 壓(ya) 器 容 量kVA
|
50000
|
31500
|
20000
|
10000
|
5600
|
高壓-中壓、低壓、地
|
14200
|
11400
|
8700
|
6150
|
4200
|
中壓-高壓、低壓、地
|
24800
|
11800
|
13200
|
9600
|
-
|
低(di)壓(ya)-高壓(ya)、中壓(ya)、地
|
19300
|
19300
|
12000
|
9400
|
6800
|
6、220kV級(ji)中性點(dian)非全級(ji)絕(jue)緣部分變壓(ya)器(qi)的電容(pF)
試 品 型(xing) 號
|
SEPSL-63000
|
SSPSL-120000
|
SSPSL-240000
|
類 型(xing)
|
高壓(ya)-中壓(ya)、低(di)壓(ya)及地
|
12100
|
13500
|
17050
|
中(zhong)壓-高壓、低壓及(ji)地(di)
|
18500
|
19700
|
23260
|
低壓(ya)-高壓(ya)、中(zhong)壓(ya)及地(di)
|
18200
|
23600
|
29940
|
試 品(pin) 型 號
|
SFPL-240000
|
SFP-360000
|
SFPSZL-120000
|
類(lei) 型
|
高壓(ya)-中壓(ya)、低壓(ya)及地
|
32230
|
33910
|
38020
|
中壓-高壓、低壓及地
|
-
|
-
|
23260
|
低壓-高壓、中壓及地
|
22470
|
23790
|
22160
|
7、油浸式電(dian)力變壓(ya)器(qi)交流試(shi)驗電(dian)壓(ya)
額定電壓
(k V)
|
*高工作
電(dian)壓(k V)
|
線端交(jiao)流試驗電(dian)壓(ya)值(kV)
|
中性點交流(liu)試(shi)驗電壓(ya)值(kV)
|
全部(bu)更換繞(rao)組
|
部分更換(huan)繞組(zu)或交接(jie)
|
全部更換(huan)繞組(zu)
|
部(bu)分更換繞組或(huo)交接
|
<1
|
≤1
|
3
|
2.5
|
3
|
2.5
|
3
|
3.5
|
18
|
15
|
18
|
15
|
6
|
6.9
|
25
|
21
|
25
|
21
|
10
|
11.5
|
35
|
30
|
35
|
30
|
15
|
17.5
|
45
|
38
|
45
|
38
|
20
|
23.0
|
55
|
47
|
55
|
47
|
35
|
40.5
|
85
|
72
|
85
|
72
|
110
|
126.0
|
200
|
170(195)
|
95
|
80
|
220
|
252.0
|
360
|
306
|
85
|
72
|
395
|
336
|
(200)
|
(170)
|
500
|
550.0
|
630
|
536
|
85
|
72
|
680
|
578
|
140
|
120
|
8、部分型號發電(dian)機(ji)定子繞組(zu)的單相(xiang)對地電(dian)容量
類別
|
發 電 機(ji)
|
型號(hao)
|
生(sheng)產廠家
|
額(e)定容量(MW)
|
額定(ding)電壓(kV)
|
相電容(mF)
|
火
力
發
電(dian)
機(ji)
|
QFS-125-2
|
上海電機廠
|
125
|
13.8
|
0.08-0.12
|
QFSN-200-2
|
哈爾(er)濱電機廠
|
200
|
15.75
|
0.19-0.21
|
QFQS-200-2
|
東方電機廠
|
200
|
15.75
|
0.1928-0.21
|
QFQS-200-2
|
北京重型電機廠
|
200
|
15.75
|
0.18-0.19
|
QFS-300-2
|
上(shang)海電機廠
|
300
|
18.0
|
0.16-0.20
|
QFSN-300-2
|
上海(hai)電機廠
|
300
|
18.0
|
0.18-0.20
|
ATB-2
|
美國GE公司(si)
|
352
|
23.0
|
0.268(設計值(zhi))
|
TBB-320-2
|
(前蘇聯)
|
320
|
20.0
|
0.31
|
2-105×234
|
美(mei)國西屋公(gong)司
|
600
|
20.0
|
0.2(工廠試驗(yan)值)
|
50WT23E-138
|
ABB
|
600
|
22.0
|
0.253(設計值)
|
水 發
力(li) 電(dian)
機(ji)
|
|
|
72.5 - 85
|
10.5
|
0.694
|
|
|
300
|
15.75
|
1.7-2.5
|
|
|
400
|
18.0
|
2-2.5
|
9、同步(bu)發電機(ji)定子繞組交(jiao)流試驗電壓
1
|
全部更換定子繞組(zu)并修好(hao)后的試驗(yan)電壓
|
容量kW或kVA
|
小于(yu)10000
|
10000及以(yi)上(shang)
|
額定電(dian)壓Un (V)
|
36以上
|
6000以下(xia)
|
6000~18000
|
18000以上
|
試驗電壓V
|
2Un+1000但*低為1500
|
2.5Un
|
2Un
+3000
|
按(an)專門協議
|
2
|
大修(xiu)前或局部更換定子繞組(zu)并修(xiu)好(hao)后的試驗電壓
|
運行20年及以下者
|
1.5 Un
|
運行20年(nian)以上與架空線路直接連接者
|
1.5 Un
|
運(yun)行20年(nian)以(yi)上不(bu)與架空線路直接連(lian)接者
|
(1.3~1.5)Un
|
十五、設備成套(tao)性:
變頻電源 1臺(tai)
勵(li)磁(ci)變壓(ya)器 1臺
電抗器 4臺
電容分壓器 1臺(tai)
附件及(ji)測試線(xian) 1套
支架 15KV 1只
均(jun)壓罩 200KV 2只
絕緣(yuan)底板 2塊(kuai)
一、產品概述
YDQC系列(lie)(lie)輕型(xing)交直流高壓(ya)試(shi)(shi)驗(yan)(yan)變壓(ya)器是在(zai)同(tong)類產品YDJ(G)型(xing)高壓(ya)試(shi)(shi)驗(yan)(yan)變壓(ya)器的基礎(chu)上(shang),按試(shi)(shi)驗(yan)(yan)變壓(ya)器國家(jia)標準ZBK41006—89要求,經(jing)改進后生產的一種新型(xing)產品,本系列(lie)(lie)產品具有(you)體積小、重量輕、結構緊(jin)湊(cou)、功能齊全、使用方(fang)便等特點。實用于電(dian)力、工(gong)礦、科研等部(bu)門(men),對各種高壓(ya)電(dian)氣設備、電(dian)氣元(yuan)件、絕緣材料進行工(gong)頻耐(nai)壓(ya)試(shi)(shi)驗(yan)(yan)和直流泄(xie)漏試(shi)(shi)驗(yan)(yan),是高壓(ya)試(shi)(shi)驗(yan)(yan)中必不可少的儀器。
二、產品(pin)結構(gou)
YDQC系列輕型高壓(ya)試驗變(bian)壓(ya)器鐵(tie)芯(xin)為單框式。線圈采用同(tong)芯(xin)圓(yuan)筒多(duo)層塔式結構(gou)(gou),初級(ji)低壓(ya)繞(rao)(rao)組繞(rao)(rao)在鐵(tie)芯(xin)上,次級(ji)高壓(ya)繞(rao)(rao)組繞(rao)(rao)在低壓(ya)繞(rao)(rao)組外側,這種同(tong)軸布置減少了繞(rao)(rao)組間的(de)藕合損耗。高壓(ya)硅堆用特(te)殊(shu)工藝封裝在套管內,產品的(de)外殼制成與器芯(xin)配合較佳的(de)八角(jiao)形結構(gou)(gou),整體外型美(mei)觀大方。其內外部(bu)結構(gou)(gou)見圖(tu)1。
1-均(jun)壓(ya)(ya)(ya)球;2-硅堆(dui)短路桿;3-高壓(ya)(ya)(ya)套管(guan);4-油(you)閥;5-殼體;6、7-調整電壓(ya)(ya)(ya)輸入a、x端(duan)(duan)子(zi);8、9-儀(yi)表測量E、F端(duan)(duan)子(zi);10-高壓(ya)(ya)(ya)尾X端(duan)(duan)子(zi);11-變壓(ya)(ya)(ya)器(qi)外殼接地端(duan)(duan);12-高壓(ya)(ya)(ya)輸出(chu)A端(duan)(duan)子(zi);13-高壓(ya)(ya)(ya)整流硅堆(dui);14-內部均(jun)壓(ya)(ya)(ya)環(huan);15-變壓(ya)(ya)(ya)器(qi)鐵芯;16-初級低壓(ya)(ya)(ya)繞組;17-測量儀(yi)表繞組;18-二次級高壓(ya)(ya)(ya)繞組;19-變壓(ya)(ya)(ya)器(qi)油(you)。
三、工作原理
YDQC系列(lie)輕型高(gao)壓(ya)(ya)(ya)(ya)試(shi)驗變壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)為單(dan)相(xiang)變壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi),聯結組(zu)標號II。單(dan)臺(tai)高(gao)壓(ya)(ya)(ya)(ya)試(shi)驗變壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)的(de)(de)工(gong)作過程,用交流220V(10KVA以上(shang)為380V)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)接入電(dian)(dian)(dian)源控制箱(xiang)(xiang)(臺(tai)),經電(dian)(dian)(dian)源控制箱(xiang)(xiang)(臺(tai))內自藕調壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(50KVA以上(shang)調壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)外附)調節0~200V(10KVA以上(shang)0~400V)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)至(zhi)試(shi)驗變壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)的(de)(de)初級繞(rao)組(zu),根據電(dian)(dian)(dian)磁(ci)感應原(yuan)理,在試(shi)驗變壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)高(gao)壓(ya)(ya)(ya)(ya)繞(rao)組(zu)可獲(huo)得試(shi)驗所需的(de)(de)高(gao)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)。其工(gong)作原(yuan)理圖見圖2所示。
1、單臺YDQC高壓試驗變壓器工作原理示意圖
在(zai)試驗變壓器中:a、x為低壓輸入(ru)端;A、X 為高壓輸出端;E、F為儀表測量端。
2、單臺交直流兩用型高壓試驗變壓器工作原理見圖3。圖中所示:高壓套管內裝有高壓硅堆,串接在高壓回路中作高壓整流,以獲得直流高電壓。當用一短路桿將高壓硅堆短接時,可獲得交流高電壓,其狀態為交流輸出;反之在抽出短路桿時,其狀態為直流輸出。
3、三臺高壓試驗變壓器串激獲得更高電壓原理見圖4,串激高壓試驗變壓器有很大的優越性,因為整個試驗裝置由多個單臺串激式試驗變壓器組成,單臺試驗變壓器有著體積小、重量輕、便于運輸的特點,它既可以串接成高出幾倍的單臺試驗變壓器輸出電壓組合使用,又可以分開單獨使用。整套試驗裝置投資小、經濟實惠。圖3所示:在三臺串激式試驗變壓器串激使用中,單臺試驗變壓器B1、B2、B3的輸出電壓都是U,**、二級的試驗變壓器內部都有一個激磁繞組,分別為A1、C1 和A2、C2。當控制電壓加在第**試驗變壓器B1的初級繞組a1、x1上,激磁繞組A1、C1給予試驗變壓器B2初級繞組供電,**級試驗變壓器B2的激磁繞組A2、C2給試驗變壓器B3的初級繞組供電。由于第**試驗變壓器B1的高壓尾及殼體接地,**、三級的試驗變壓器B2和B3對地有絕緣支架的隔離,這樣試驗變壓器B1、B2、B3對地輸出電壓分別為1U、2U、3U。
B1、B2、B3- 串激式高壓變壓器(qi);1U、2U、3U-各級對地電(dian)壓;
PV- 高壓示值(zhi)表(KV); ZJ1、ZJ2-絕緣支架。
四、使用(yong)方法及注意事(shi)項
1、YDQC高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器做(zuo)工頻(pin)耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗使用接線方法見(jian)圖5。做(zuo)工頻(pin)耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗前,先根據(ju)試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器的(de)額定(ding)容(rong)量選擇好(hao)限流電(dian)阻(zu),(水電(dian)阻(zu))的(de)阻(zu)值(zhi),再根據(ju)被(bei)試(shi)(shi)品需加的(de)高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)值(zhi)調整好(hao)放電(dian)球隙的(de)球間距,為(wei)了提高(gao)對(dui)被(bei)試(shi)(shi)品施加電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)的(de)測量精度(du),應在高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)側(ce)接入(ru)FRC阻(zu)容(rong)分(fen)壓(ya)(ya)(ya)(ya)(ya)(ya)器來測量電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)。
R1、R2- 限(xian)流(liu)電(dian)阻; Qx- 放(fang)電(dian)球隙; Zx- 被試品(pin);
FRC- 阻容分壓器; V- 分壓器高壓表。
按照圖4、結合圖2所進行的工頻耐壓試驗接好工作線路,試驗變壓器的高壓繞阻的X端(高壓尾)、儀表測量繞組的F端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
用三臺試驗變壓器串激做工頻耐壓試驗時、**、三級試驗變壓器的初級繞組X端,儀表測量繞組的F端,以及高壓繞組的X端(高壓尾)均接本級試驗變壓器的外殼,**、三級試驗變壓器的主體必須放置在絕緣支架上。除第**以外、**、三級試驗變壓器的主體不要接地線。其接線方式見圖3所示。
接電源前,電源控制箱(臺)的調壓器必須調到零位。接通電源后,綠色指示燈亮,按一下啟動按鈕,紅色指示燈亮,表示試驗變壓器已接通控制電源,開始升壓。
從零位開始按順時針方向勻速旋轉調壓器手輪升壓。(升壓方式有:快速升壓法,即20S逐級升壓法,慢速升壓法,即60S逐級升壓法,極慢速升壓法供選用)電壓從零開始按選定的升壓速度升到您所需額定試驗電壓的75%后,再以每秒2%額定試驗電壓的速度升到您所需試驗電壓,并密切注意測量儀表的指示以及被試品的情況,被試品施加電壓的時間到后。應在數秒內勻速將調壓器返回,高壓降至1/3試驗電壓以下,按一下停止按鈕,高壓、低壓輸出停止,然后切斷電源線,試驗完畢。
工頻耐壓試驗操作過程注意事項
1、試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
2、被試品主要部位應**干凈,保持**干燥,以免損壞被試品和帶來試驗數值的誤差。
3、對大型設備的試驗,一般都應先進行試驗變壓器的空升試驗,即不接試品時升壓至試驗電壓,以便校對好儀表的指示精度,調整好放電球隙的球間距。
4、做耐壓試驗時升壓速度不能過快,并防止突然加壓,例如調壓器不在零位的突然合閘,也不能突然斷電,一般應在調壓器降至零位時分閘。
5、在升壓或耐壓試驗過程中,如發現下列不正常情況,1 電壓、電流表指針擺動很大,2 被試品發出不正常響聲,3 發現絕緣有燒焦或冒煙現象,應立即降壓,切斷電源,停止試驗并查明原因。
6、使用本產品做高壓試驗時,除熟悉本說明書外,還必須嚴格執行國家有關標準和操作規程。
2、YDQ交直(zhi)(zhi)(zhi)流兩(liang)用高(gao)(gao)壓(ya)(ya)試(shi)(shi)(shi)驗(yan)變(bian)壓(ya)(ya)器(qi)做直(zhi)(zhi)(zhi)流耐壓(ya)(ya)和泄漏(lou)試(shi)(shi)(shi)驗(yan)使用接線方法見圖5。由于是交直(zhi)(zhi)(zhi)流兩(liang)用高(gao)(gao)壓(ya)(ya)試(shi)(shi)(shi)驗(yan)變(bian)壓(ya)(ya)器(qi),應把(ba)高(gao)(gao)壓(ya)(ya)硅堆短路(lu)桿從套管中抽出(chu)(chu),使試(shi)(shi)(shi)驗(yan)變(bian)壓(ya)(ya)器(qi)為(wei)直(zhi)(zhi)(zhi)流輸出(chu)(chu)狀(zhuang)態。做直(zhi)(zhi)(zhi)流泄漏(lou)試(shi)(shi)(shi)驗(yan)前,先(xian)根據泄漏(lou)試(shi)(shi)(shi)驗(yan)中輸出(chu)(chu)端斷路(lu)電流不超(chao)過高(gao)(gao)壓(ya)(ya)硅堆的*大整流為(wei)宜,選擇(ze)好限流電阻(zu)(zu)(水電阻(zu)(zu))的阻(zu)(zu)值,再根據被試(shi)(shi)(shi)品(pin)對(dui)(dui)直(zhi)(zhi)(zhi)流高(gao)(gao)壓(ya)(ya)波(bo)形的要(yao)求選擇(ze)好高(gao)(gao)壓(ya)(ya)濾(lv)波(bo)電容(rong)的電容(rong)值。為(wei)了提高(gao)(gao)對(dui)(dui)被試(shi)(shi)(shi)品(pin)施加電壓(ya)(ya)的測量精度,應在高(gao)(gao)壓(ya)(ya)側接入FRC阻(zu)(zu)容(rong)分壓(ya)(ya)器(qi)來測量電壓(ya)(ya)。
R- 限流電阻; C- 高壓濾波電容; Zx- 被(bei)試(shi)品; G- 硅堆(dui)短(duan)路桿;
FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高壓整流硅堆。
按照圖5、結合圖3所進行的直流泄漏試驗接好工作線路。試驗變壓器的高壓繞組的X端(高壓尾)、儀表測量繞組的F 端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
接(jie)電源(yuan)前、電源(yuan)控(kong)制箱(臺)的調(diao)壓(ya)器必須(xu)調(diao)到零位。接(jie)通(tong)電源(yuan)后,綠(lv)色指(zhi)示(shi)燈(deng)亮(liang),按(an)一下啟動按(an)鈕,紅色指(zhi)示(shi)燈(deng)亮(liang),表(biao)示(shi)試驗變壓(ya)器已接(jie)通(tong)控(kong)制電源(yuan),開(kai)始升(sheng)壓(ya)。
從(cong)零位開(kai)始按順(shun)時(shi)(shi)針方(fang)向勻速(su)旋轉(zhuan)調壓(ya)器手(shou)輪升(sheng)(sheng)壓(ya)。(升(sheng)(sheng)壓(ya)方(fang)式有:快(kuai)速(su)升(sheng)(sheng)壓(ya)法即20S逐級(ji)升(sheng)(sheng)壓(ya)法;慢(man)速(su)升(sheng)(sheng)壓(ya)法,即60S逐級(ji)升(sheng)(sheng)壓(ya)法;級(ji)慢(man)速(su)升(sheng)(sheng)壓(ya)法供選(xuan)(xuan)用)電壓(ya)從(cong)零開(kai)始按選(xuan)(xuan)定(ding)的(de)(de)升(sheng)(sheng)壓(ya)速(su)度升(sheng)(sheng)到您所需額定(ding)試驗(yan)電壓(ya)或額定(ding)直流(liu)電流(liu)下的(de)(de)參考電壓(ya)。試驗(yan)中(zhong)應(ying)嚴密注意(yi)直流(liu)高(gao)(gao)壓(ya)表、泄(xie)漏電流(liu)表指示以及被(bei)試品(pin)的(de)(de)情況。試驗(yan)完畢(bi)后(hou),應(ying)訊速(su)均勻將高(gao)(gao)壓(ya)降至零位,按一下停(ting)(ting)止按鈕,高(gao)(gao)壓(ya)、低(di)壓(ya)輸出停(ting)(ting)止,然(ran)后(hou)切斷電源。此時(shi)(shi)應(ying)用直流(liu)高(gao)(gao)壓(ya)放**給被(bei)試品(pin)及試驗(yan)裝置本身充分放電。
直流泄漏試驗(yan)操作過程注(zhu)意事項
(1)試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
(2)被試品做試驗前,應拆除所有對外連線,并充分放電,主要部位應**干凈,保持**干燥,以免損壞被試品及帶來試驗數值的誤差。
(3)對于大容量試品(電容器、超長電纜等)試驗時應緩慢升壓,防止被試品的充電電流過大而燒壞微安表,必要時應分級加壓分別讀取各電壓下微安表的穩定讀數。
(4)試驗過程中,應嚴密監視被試品、微安表及試驗裝置等,一旦發生閃爍、擊穿等現象應立即降壓,切斷電源,并查明原因。
五、配套選購產品
下列產品僅供選擇,購買時需另行計價。
1.KZX系列電源控制箱 容量:1KVA-5KVA、輸入電壓:220V
2.KZT系列電源控制臺 容量:10KVA~300KVA輸入電壓:220V或380V
3.數字微安表:SWB-II
4.高壓濾波電容: 0.01MF、40 ~ 100KV
5.高壓直流放**: FBR— 70、140、210KV
6.放電球隙: Q—50、100、150、200、250、500
7.標準試油杯: 400ml
8.折疊式手推車: 150、300型
9.絕緣支架: 50、100、200、300、400KV
10.阻容分壓器: FRC —50、100、150、200KV
11.高壓硅堆: 2DL—150、300、450KV
12.水 電 阻: 50、100
六、主(zhu)要(yao)試驗設(she)備的選(xuan)擇
1、試驗變壓器
其高壓側額定電壓應不小于被試品的*高試驗電壓,額定電流不小于被試品的*大電容電流。被試品的電容電流和試驗變壓器所需容量計算式為:
被試品電容量(liang)Cx可由交流電橋測出。常(chang)用的被試品電容量(liang)按表1選取(qu)。
幾(ji)種常用被試(shi)品的(de)電(dian)容量(liang)(pF) 表1
2、調壓設備
(1)自藕調壓器。其調壓范圍廣、功率損耗小、波形畸變小、選擇這種調壓方式為*好。自藕調壓器的容量按0.75 ~ 1倍的試驗變壓器的容量選擇,適用于容量為100KVA以下的試驗變壓器的調壓。
(2)感應調壓器。其調壓范圍大,波形畸形小、但結構復雜、價格較貴,當試驗變壓器的容量較大時(如100KVA以上)使用。
3、限流電阻
限流電阻的作用是,當被試品擊穿時,限制斷路電流,從而保護試驗變壓器,防止故障的擴大。其數值以*高試驗電壓為準,按0.5 ~ 1 Ω / V(有效值)選擇,限流電阻可用水電阻。注意水不能充滿玻璃管,應留有余地,以防爆裂。
4、放電球隙
放電球隙的布置方式有垂直和水平兩種,球隙間距S和球的直徑D的關系應保護在0.05D ≤S ≤0.5D范圍內,球隙上的水電阻阻值一般按0.1 ~ 1Ω/V選取,設置放電球隙的目的是為了對重要的被試品起保護作用,可以將由于誤操作或被試品擊穿引起的過電壓限制在允許的范圍內。
七、試驗變(bian)壓器(qi)技(ji)術(shu)指(zhi)示
型號(hao)
|
容(rong)量
|
高壓(ya)電壓(ya)
|
高壓(ya)電(dian)流
|
低壓輸入
|
變比
|
溫升(sheng)℃
|
(KVA)
|
(KV)
|
(mA)
|
電壓(V)
|
電(dian)流(liu)(A)
|
高(gao)/儀
|
30分鐘
|
YDQC-1.5/50
|
1.5
|
50
|
30
|
200
|
7.5
|
500
|
10
|
YDQC-3/50
|
3
|
50
|
60
|
200
|
15
|
500
|
10
|
YDQC-5/50
|
5
|
50
|
100
|
200
|
25
|
500
|
10
|
YDQC-10/50
|
10
|
50
|
200
|
200
|
50
|
500
|
10
|
YDQC-15/50
|
15
|
50
|
300
|
200
|
75
|
500
|
10
|
YDQC-20/50
|
20
|
50
|
400
|
380
|
53
|
500
|
10
|
YDQC-30/50
|
30
|
50
|
600
|
380
|
79
|
500
|
10
|
YDQC-50/50
|
50
|
50
|
1000
|
380
|
12
|
500
|
10
|
YDQC-5/100
|
5
|
100
|
50
|
200
|
25
|
1000
|
10
|
YDQC-10/100
|
10
|
100
|
100
|
200
|
50
|
1000
|
10
|
YDQC-20/100
|
20
|
100
|
200
|
400
|
50
|
1000
|
10
|
YDQC-30/100
|
30
|
100
|
300
|
400
|
75
|
1000
|
10
|
YDQC-50/100
|
50
|
100
|
500
|
400
|
125
|
1000
|
10
|
YDQC-20/150
|
20
|
150
|
133
|
400
|
50
|
1500
|
10
|
YDQC-30/150
|
30
|
150
|
200
|
400
|
75
|
1500
|
10
|
YDQC-50/150
|
50
|
150
|
333
|
400
|
125
|
1500
|
10
|
YDQC-100/150
|
100
|
150
|
667
|
400
|
250
|
1500
|
10
|
YDQC-50/200
|
50
|
200
|
250
|
400
|
125
|
2000
|
10
|
YDQC-100/200
|
100
|
200
|
500
|
400
|
250
|
2000
|
10
|
YDQC-150/200
|
150
|
200
|
750
|
400
|
375
|
2000
|
10
|
YDQC-200/200
|
200
|
200
|
1000
|
400
|
500
|
2000
|
10
|
YDQC-300/200
|
300
|
200
|
1500
|
400
|
600
|
2000
|
10
|
YDQC-50/300
|
50
|
300
|
170
|
400
|
125
|
3000
|
10
|
YDQC-100/300
|
100
|
300
|
333
|
400
|
250
|
3000
|
10
|
YDQC-150/300
|
150
|
300
|
500
|
400
|
375
|
3000
|
10
|
YDQC-200/300
|
200
|
300
|
667
|
400
|
500
|
3000
|
10
|
YDQC-300/300
|
300
|
300
|
3000
|
500
|
600
|
3000
|
10
|
1、使用環境條件
環境溫度不高于+40℃、不低于—20℃;空氣相對濕度不大于90%;海拔高度不超過2000米;
2、工作電壓
電源控制箱(臺)輸入電壓為工頻220V或380V、相對誤差不超過±10%;(具體使用電壓根據用戶所定試驗變壓器規格選取)
八、隨貨文件
YDQC 系列試驗變壓器產品說明書 1份
產品出廠試驗報告 1份
產品合格證 1份
裝箱單 1份
一、概(gai)述
YDQ系列高(gao)(gao)壓(ya)(ya)試驗(yan)變壓(ya)(ya)器(qi)(qi)是(shi)(shi)(shi)(shi)根據《試驗(yan)變壓(ya)(ya)器(qi)(qi)》標(biao)準,在(zai)油(you)(you)浸式試驗(yan)變壓(ya)(ya)器(qi)(qi)的(de)(de)(de)(de)(de)基礎上而設計生產(chan)(chan)的(de)(de)(de)(de)(de)。SF6氣(qi)體(ti)具有(you)良好的(de)(de)(de)(de)(de)電(dian)(dian)氣(qi)絕(jue)緣(yuan)性能及(ji)優異的(de)(de)(de)(de)(de)滅弧(hu)性能,其(qi)耐壓(ya)(ya)強(qiang)度為同一(yi)壓(ya)(ya)力下(xia)(xia)氮(dan)氣(qi)的(de)(de)(de)(de)(de)2.5倍,擊(ji)穿電(dian)(dian)壓(ya)(ya)的(de)(de)(de)(de)(de)空氣(qi)的(de)(de)(de)(de)(de)2.5倍。在(zai)0.25MPa下(xia)(xia)與油(you)(you)的(de)(de)(de)(de)(de)擊(ji)穿電(dian)(dian)壓(ya)(ya)相等(deng),在(zai)0.45MPa壓(ya)(ya)力下(xia)(xia)是(shi)(shi)(shi)(shi)油(you)(you)的(de)(de)(de)(de)(de)擊(ji)穿電(dian)(dian)壓(ya)(ya)的(de)(de)(de)(de)(de)2倍,是(shi)(shi)(shi)(shi)一(yi)種優于(yu)油(you)(you)的(de)(de)(de)(de)(de)新一(yi)代超高(gao)(gao)壓(ya)(ya)絕(jue)緣(yuan)介質材料。該產(chan)(chan)品(pin)(pin)技(ji)術要求完(wan)全符合《ZBK-41006-89》標(biao)準,它是(shi)(shi)(shi)(shi)油(you)(you)浸式輕型試驗(yan)變壓(ya)(ya)器(qi)(qi)的(de)(de)(de)(de)(de)換代產(chan)(chan)品(pin)(pin)。該產(chan)(chan)品(pin)(pin)具有(you)體(ti)積小、重量輕、不受氣(qi)候變化影(ying)響、電(dian)(dian)暈小、現場搬(ban)運無需靜止可使(shi)用,使(shi)用壽命長、免維修等(deng)特點。適用于(yu)電(dian)(dian)力系統、工礦企業、科(ke)研(yan)部門等(deng)對各種高(gao)(gao)壓(ya)(ya)電(dian)(dian)氣(qi)設備、電(dian)(dian)氣(qi)元(yuan)件、絕(jue)緣(yuan)材料進行工頻(pin)或直(zhi)流(liu)高(gao)(gao)壓(ya)(ya)下(xia)(xia)的(de)(de)(de)(de)(de)絕(jue)緣(yuan)強(qiang)度試驗(yan)。
二、產品結(jie)構
YDQ系列高(gao)壓(ya)試驗(yan)變壓(ya)器采用單框芯(xin)(xin)式鐵(tie)芯(xin)(xin)結(jie)構(gou)(gou),初(chu)級繞組繞在鐵(tie)芯(xin)(xin)上,高(gao)壓(ya)繞組在外,這種(zhong)同軸布置減少了漏磁通,因而增大(da)了繞組間的耦合(he)。產品的外殼為圓柱灌式容器結(jie)構(gou)(gou),能耐受0.8MPa以上壓(ya)力。其結(jie)構(gou)(gou)見(jian)圖1:
三、工(gong)作(zuo)原理
YDQ系列高壓試驗(yan)(yan)(yan)變(bian)壓器(qi)(qi)為(wei)單(dan)相(xiang)變(bian)壓器(qi)(qi),聯結組標號Ⅰ.Ⅰ. 用(yong)工頻220V(10kVA以上(shang)為(wei)380V)電(dian)源接入 (為(wei)本公(gong)司生產的試驗(yan)(yan)(yan)變(bian)壓器(qi)(qi)配套(tao)專用(yong)設備(bei),詳細資料請見其具(ju)體使用(yong)說明書(shu))系列操作(zuo)箱(xiang)(臺),經操作(zuo)箱(xiang)內(nei)自偶(ou)調(diao)(diao)壓器(qi)(qi)(50kVA以上(shang)調(diao)(diao)壓器(qi)(qi)外附)調(diao)(diao)節至0~200V(或0~400V)電(dian)壓輸出至YDQ試驗(yan)(yan)(yan)變(bian)壓器(qi)(qi)的初級(ji)繞組,根據電(dian)磁感應原理(li),在試驗(yan)(yan)(yan)變(bian)壓器(qi)(qi)高壓繞組可(ke)獲得試驗(yan)(yan)(yan)所(suo)需的高電(dian)壓。
單臺YDQ系列交直(zhi)流(liu)高(gao)(gao)(gao)壓(ya)(ya)(ya)試驗變(bian)壓(ya)(ya)(ya)器的工作(zuo)(zuo)原(yuan)理圖見圖3,圖中高(gao)(gao)(gao)壓(ya)(ya)(ya)套管中裝有高(gao)(gao)(gao)壓(ya)(ya)(ya)硅堆,串(chuan)接(jie)(jie)在高(gao)(gao)(gao)壓(ya)(ya)(ya)回路中作(zuo)(zuo)半波(bo)整流(liu),以獲得直(zhi)流(liu)高(gao)(gao)(gao)電(dian)壓(ya)(ya)(ya)。當用一短路桿將高(gao)(gao)(gao)壓(ya)(ya)(ya)硅堆短接(jie)(jie)時(shi),可獲得工頻高(gao)(gao)(gao)電(dian)壓(ya)(ya)(ya),作(zuo)(zuo)為交流(liu)輸出狀態(tai);取消短路桿時(shi),作(zuo)(zuo)為直(zhi)流(liu)輸出狀態(tai)。
圖中:D—短路桿 VD—高(gao)壓硅堆
試驗變壓器高(gao)壓套管中的高(gao)壓硅堆未畫出,其原理與上圖相同(tong)。
三(san)臺(tai)(tai)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)串(chuan)(chuan)級(ji)(ji)獲得更(geng)高電(dian)壓(ya)(ya)(ya)(ya)(ya)的(de)(de)(de)(de)(de)接(jie)線(xian)原(yuan)理見(jian)圖(tu)(tu)4。串(chuan)(chuan)級(ji)(ji)高壓(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)有很大的(de)(de)(de)(de)(de)優越性,因為整個試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)裝(zhuang)置由幾臺(tai)(tai)單(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)組(zu)(zu)(zu)成,單(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)容量(liang)小、電(dian)壓(ya)(ya)(ya)(ya)(ya)低(di)(di)、重(zhong)量(liang)輕,便于(yu)運輸(shu)(shu)和(he)安裝(zhuang)。它既然可(ke)串(chuan)(chuan)接(jie)成高出幾倍(bei)的(de)(de)(de)(de)(de)單(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)輸(shu)(shu)出電(dian)壓(ya)(ya)(ya)(ya)(ya)組(zu)(zu)(zu)合使用,又可(ke)分開成幾套(tao)單(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)單(dan)獨使用。整套(tao)裝(zhuang)置投資小,經濟實惠。圖(tu)(tu)5中(zhong),在第**和(he)**級(ji)(ji)的(de)(de)(de)(de)(de)每個單(dan)元試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)中(zhong)都有一個勵磁(ci)繞(rao)組(zu)(zu)(zu)A1、C1和(he)A2、C2。在三(san)臺(tai)(tai)串(chuan)(chuan)級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)基本原(yuan)理中(zhong),低(di)(di)壓(ya)(ya)(ya)(ya)(ya)電(dian)源加在試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅰ的(de)(de)(de)(de)(de)初(chu)級(ji)(ji)繞(rao)組(zu)(zu)(zu)a1x1上,單(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅰ、Ⅱ、Ⅲ的(de)(de)(de)(de)(de)輸(shu)(shu)出電(dian)壓(ya)(ya)(ya)(ya)(ya)都是V。勵磁(ci)繞(rao)組(zu)(zu)(zu)A1、C1給(gei)**級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅱ的(de)(de)(de)(de)(de)初(chu)級(ji)(ji)繞(rao)組(zu)(zu)(zu)供(gong)電(dian);**級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅱ的(de)(de)(de)(de)(de)勵磁(ci)繞(rao)組(zu)(zu)(zu)A2、C2給(gei)第三(san)級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅲ的(de)(de)(de)(de)(de)初(chu)級(ji)(ji)繞(rao)組(zu)(zu)(zu)供(gong)電(dian)。**級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅱ和(he)第三(san)級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅲ的(de)(de)(de)(de)(de)箱(xiang)體分別處(chu)在對地(di)為1V和(he)2V的(de)(de)(de)(de)(de)高電(dian)位上,所(suo)以箱(xiang)體對地(di)是絕緣的(de)(de)(de)(de)(de),試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅰ的(de)(de)(de)(de)(de)箱(xiang)體是接(jie)地(di)的(de)(de)(de)(de)(de)。這(zhe)樣第**、**級(ji)(ji)、第三(san)級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)對地(di)的(de)(de)(de)(de)(de)額(e)定輸(shu)(shu)出電(dian)壓(ya)(ya)(ya)(ya)(ya)分別為1V、2V、3V;其額(e)定容量(liang)分別為3P、2P、1P。
YDQ系列高壓試驗變(bian)壓器做(zuo)被試品(pin)的工頻(pin)耐壓試驗使(shi)用(yong)接線原(yuan)理圖(tu)見(jian)圖(tu)5。
圖中:R1—限流電阻 FRC—阻容(rong)分壓器 RF—球間隙保護電阻 G—球間隙 CX—被試品
注:高壓尾(wei)必(bi)須(xu)可靠接地(di)
工頻耐壓試(shi)驗(yan)中(zhong)限(xian)流電阻R1應(ying)根據試(shi)驗(yan)變壓器的額定(ding)(ding)容(rong)量(liang)來選擇。如高壓側額定(ding)(ding)輸(shu)出(chu)電流在100~300mA時(shi),可(ke)取0.5~1Ω/V(試(shi)驗(yan)電壓);高壓側額定(ding)(ding)輸(shu)出(chu)電流為1A以上時(shi),可(ke)取1Ω/V(試(shi)驗(yan)電壓)。常用水電阻作為限(xian)流電阻,管子長度可(ke)按150kV/m考慮,管子粗細應(ying)具有足(zu)夠的熱容(rong)量(liang)(水阻液配(pei)(pei)制(zhi)方(fang)法:用蒸餾水加入適量(liang)硫酸(suan)銅配(pei)(pei)制(zhi)成各種不同的阻值)。
球(qiu)間隙(xi)(xi)及保護電阻:當電壓(ya)超(chao)過球(qiu)間隙(xi)(xi)整定值(zhi)時(一般取試驗(yan)(yan)電壓(ya)的110%~120%),球(qiu)間隙(xi)(xi)放電,對被試品起(qi)到保護作用。球(qiu)間隙(xi)(xi)保護電阻可按1Ω/V(試驗(yan)(yan)電壓(ya))選取。
在(zai)工頻(pin)耐壓(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)中,低電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)側測(ce)量電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(儀表(biao)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya))不是非常準確(que)的(de)(de)(de),其(qi)原因是由于試(shi)(shi)驗(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)存(cun)在(zai)著(zhu)(zhu)漏(lou)抗(kang),在(zai)這個漏(lou)抗(kang)上(shang)必然(ran)存(cun)在(zai)著(zhu)(zhu)壓(ya)(ya)(ya)(ya)降或容(rong)升,使試(shi)(shi)品上(shang)的(de)(de)(de)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)低于或高(gao)于低壓(ya)(ya)(ya)(ya)側測(ce)量電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)表(biao)上(shang)反映(ying)出來的(de)(de)(de)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)。工頻(pin)耐壓(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)時(shi),被(bei)(bei)試(shi)(shi)品上(shang)的(de)(de)(de)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)高(gao)于試(shi)(shi)驗(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)的(de)(de)(de)輸(shu)出電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya),也(ye)就是所謂容(rong)升現象。感應耐壓(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)時(shi),試(shi)(shi)驗(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)的(de)(de)(de)漏(lou)抗(kang)必然(ran)存(cun)在(zai)著(zhu)(zhu)壓(ya)(ya)(ya)(ya)降。為了準確(que)測(ce)量被(bei)(bei)試(shi)(shi)品上(shang)所施(shi)加的(de)(de)(de)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya),因此(ci)常在(zai)高(gao)壓(ya)(ya)(ya)(ya)側接入FRC阻(zu)容(rong)分(fen)壓(ya)(ya)(ya)(ya)器(qi)來測(ce)量電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(見圖5)。
工頻耐壓試驗操(cao)作注意(yi)事項
1)試驗人員(yuan)應做(zuo)好分(fen)工,明確相(xiang)互間聯系方(fang)法。并有專門(men)人監護現場**及觀察試品狀(zhuang)態。
2)被試(shi)品應(ying)先清掃(sao)干凈(jing),并**干燥,以免損壞被試(shi)品和試(shi)驗帶來的(de)誤(wu)差。
3)對于大型試(shi)(shi)驗(yan),一般都應(ying)先(xian)進行空升(sheng)(sheng)試(shi)(shi)驗(yan)。即(ji)不接(jie)試(shi)(shi)品(pin)時升(sheng)(sheng)壓至(zhi)試(shi)(shi)驗(yan)電壓,校對各(ge)種表計,調(diao)整球間隙(xi)。
4)升壓(ya)速度不(bu)能太快,并必須防止突(tu)然加壓(ya)。例如調壓(ya)器不(bu)在零位(wei)時(shi)突(tu)然合(he)閘(zha)。也不(bu)能突(tu)然切(qie)斷電源,一般應在調壓(ya)器降至零位(wei)時(shi)拉閘(zha)。
5)當(dang)電壓(ya)升至(zhi)試驗(yan)電壓(ya)時(shi),開始計時(shi),到(dao)1min后,迅速降壓(ya)到(dao)1/3試驗(yan)電壓(ya)以下時(shi),才(cai)能拉開電源。
6)在升壓(ya)或(huo)耐壓(ya)試驗(yan)過程中,如發現下(xia)列不(bu)正(zheng)常情況時,應立即降壓(ya),切斷電源。停止(zhi)試驗(yan)并查明原(yuan)因:①電壓(ya)表指針擺動很大;②發現絕緣燒焦或(huo)冒煙;③被(bei)試品(pin)內有不(bu)正(zheng)常的聲(sheng)音。
7)耐壓試驗前(qian)后(hou)應測量絕(jue)緣電阻,檢查絕(jue)緣情況(kuang)。
試(shi)驗(yan)變壓(ya)器在做(zuo)被試(shi)品的直流耐(nai)壓(ya)或(huo)泄露試(shi)驗(yan)時接線(xian)原理圖如圖6。
注:此試驗應先抽出短路桿“D”,圖6中所示(shi)。
圖中:VD—高壓(ya)硅堆 R1—限流電阻(zu) C1—高壓(ya)濾波電容 FRC—阻(zu)容分壓(ya)器 CX—被(bei)試品 μA—帶保(bao)護微安表
泄露試(shi)驗中限(xian)流(liu)電阻(zu)(zu)R1選擇(ze)在額定(ding)輸出(chu)電壓(ya)(ya)時,輸出(chu)端短路(lu)電流(liu)不超過高壓(ya)(ya)硅堆(dui)的(de)*大整流(liu)。如(ru)電壓(ya)(ya)硅堆(dui)的(de)*大整流(liu)電流(liu)為100mA時用(yong)于60kV的(de)試(shi)驗裝置中,限(xian)流(liu)電阻(zu)(zu)按R1=60/0.1=600kΩ選擇(ze)。限(xian)流(liu)電阻(zu)(zu)還應(ying)具有足夠的(de)容(rong)量和沿面放電距離。
高壓濾波(bo)電容C1一般(ban)選擇在0.01~0.1μF,當被試品的電容量很(hen)大時,C1可省略不用。
泄露試驗的操作及注意(yi)事(shi)項
1)試(shi)驗前應先(xian)檢查被試(shi)品是否停電(dian)(dian),接(jie)地放(fang)電(dian)(dian),一切對外連(lian)線是否擦干凈。要嚴(yan)防將試(shi)驗電(dian)(dian)壓加到有人工作的部位上去。
2)接(jie)好試驗裝(zhuang)置(zhi)的(de)接(jie)線后,應復查(cha)無誤后才可加壓(ya)。應特別(bie)注意檢查(cha)高壓(ya)設備及引線與(yu)地、與(yu)操(cao)作人員的(de)**距離,被試品的(de)外殼是(shi)否可靠接(jie)地,要按**規程中所規定的(de)內容進(jin)行試驗。
3)對(dui)于大電(dian)容(rong)量設備應(ying)緩慢升(sheng)壓,防(fang)止被(bei)試品的充電(dian)電(dian)流(liu)燒(shao)壞微(wei)(wei)安表。必要時應(ying)分級(ji)加壓,分別讀取各級(ji)電(dian)壓下微(wei)(wei)安表的穩定讀數。
4)試(shi)驗過程中,應密切監視被試(shi)品、試(shi)驗裝置、微安表(biao),一旦發(fa)生擊穿、閃爍等(deng)異常現(xian)象應立即(ji)降(jiang)壓(ya),切斷電源,并(bing)查(cha)明原因,詳細(xi)記(ji)錄。
5)試驗完畢,降壓,切斷電源后應將被試品及(ji)試驗裝置(zhi)本身充分(fen)放(fang)電。
四、注意事(shi)項
1、按照您(nin)所進行的(de)試驗接好工作線路。試驗變壓(ya)器(qi)的(de)外殼以及操作系統的(de)外殼必須可靠(kao)接地(di)(di)。試驗變壓(ya)器(qi)高壓(ya)繞(rao)(rao)組(zu)的(de)X端(高壓(ya)尾)以及測量繞(rao)(rao)組(zu)的(de)F端必須可靠(kao)接地(di)(di)。
2、做串級(ji)(ji)試(shi)驗(yan)時,**級(ji)(ji)、第三級(ji)(ji)試(shi)驗(yan)變壓(ya)器的(de)(de)低壓(ya)繞組的(de)(de)X端,測量繞組的(de)(de)F端以(yi)及高壓(ya)繞組的(de)(de)X端(高壓(ya)尾)均(jun)接本級(ji)(ji)試(shi)驗(yan)變壓(ya)器的(de)(de)外(wai)殼。**級(ji)(ji)、第三級(ji)(ji)試(shi)驗(yan)變壓(ya)器的(de)(de)外(wai)殼必須(xu)通過(guo)絕緣支架接地。
3、接通電(dian)源前,操作(zuo)系統(tong)的(de)調壓(ya)器必須調到零位后方可接通電(dian)源,合閘(zha),開始(shi)升壓(ya)。
4、從零開始(shi)均勻旋轉調壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)手輪(lun)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)。升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)方法(fa)有:快速升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)法(fa),即20s逐級升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)法(fa);慢速升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)法(fa),即60s逐級升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)法(fa);極慢速升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)法(fa)供選用。電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)從零開始(shi)按一定(ding)(ding)的(de)(de)(de)升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)方式(shi)和速度(du)上升(sheng)(sheng)(sheng)到您所(suo)(suo)需的(de)(de)(de)額定(ding)(ding)試(shi)(shi)驗電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)的(de)(de)(de)75%后(hou),在以(yi)每(mei)秒2%額定(ding)(ding)試(shi)(shi)驗電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)的(de)(de)(de)速度(du)升(sheng)(sheng)(sheng)到您所(suo)(suo)需的(de)(de)(de)額定(ding)(ding)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya),并密切(qie)注意測量儀(yi)(yi)表(biao)的(de)(de)(de)指(zhi)示(shi)以(yi)及(ji)被試(shi)(shi)品的(de)(de)(de)情況(kuang)。升(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)過程(cheng)中(zhong)或試(shi)(shi)驗過程(cheng)中(zhong)如發現測量儀(yi)(yi)表(biao)的(de)(de)(de)指(zhi)示(shi)及(ji)被試(shi)(shi)品情況(kuang)異(yi)常,應立即降(jiang)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya),切(qie)斷電(dian)源,查明情況(kuang)。
5、試驗(yan)完畢(bi)后,應在數秒(miao)內勻速的將調壓器返(fan)回至零位(wei),然(ran)后切斷(duan)電源。
6、本產品不得超(chao)過(guo)額定參數使用(yong)。除試驗必須外(wai),決不允許(xu)全電(dian)壓通電(dian)或斷電(dian)。
7、 再升壓(ya)(ya)或耐壓(ya)(ya)試驗過程(cheng)中,如發現以下不(bu)正(zheng)常情況時,應立即降壓(ya)(ya),切(qie)斷電源(yuan),停止試驗并查明原因。
⑴電壓表指針擺動(dong)(或數字跳(tiao)動(dong))很大
⑵電流表直線上升
被試品內有不正常的聲(sheng)音
8、圖1中第9項系壓(ya)力(li)閥及壓(ya)力(li)表,為(wei)長期關(guan)閉(bi)狀(zhuang)態。每6個(ge)月開閥一次,以檢(jian)查SF6壓(ya)力(li),應不小于(yu)0.2MPa(檢(jian)查壓(ya)力(li)后立即關(guan)閉(bi)閥門(men)),低于(yu)0.2MPa時應加(jia)(jia)SF6氣體,以增加(jia)(jia)氣絕緣。
9、耐壓實驗(yan)前后(hou)應測量被試設備的絕(jue)緣電(dian)阻,檢查絕(jue)緣情況(kuang)。
10、當試驗(yan)變壓器長期(qi)不使用時,應放置于通風、干燥(zao)、無(wu)陽(yang)光直射的(de)地方。
11、該(gai)產品不允(yun)許在高于45℃的溫(wen)度下長期存放(fang)、使用、放(fang)氣。
12、運(yun)輸搬(ban)運(yun)途中不得(de)重力(li)沖擊。
13、產品緊固件及壓(ya)力(li)閥、壓(ya)力(li)表(biao)不得擅自松(song)動。
14、使用本(ben)(ben)產品(pin)做(zuo)高(gao)壓(ya)試(shi)驗時(shi),出熟悉本(ben)(ben)說(shuo)明書外(wai),還必(bi)須嚴格執行國家有(you)關標(biao)準(zhun)和(he)操作規程。可參照GB311-83《高(gao)壓(ya)輸變設備的絕緣配合,高(gao)壓(ya)試(shi)驗技(ji)術》;《電氣設備預防(fang)性(xing)試(shi)驗規程》等。
五、試驗變壓器的容(rong)量選擇(ze)
標稱試驗變壓器容量Pn的確定(ding)公(gong)式:Pn=kVn 2ωCt×10-9
式中:
Pn——標稱(cheng)試驗變(bian)壓(ya)器容量(kVA)
Vn——試驗變壓器的額定輸(shu)出高壓的有效值(kV)
k ——**系數。k≥1,標(biao)(biao)稱電(dian)(dian)壓Vn≥1MV時,k=2;標(biao)(biao)稱電(dian)(dian)壓較低時,k值可(ke)取高一些。
Ct——被試品(pin)的電容量(pF)
ω——角頻(pin)率,ω=2πf,f——試驗電源的頻(pin)率
被試設備的(de)電(dian)容量Ct可由交(jiao)流電(dian)橋(qiao)測出(chu)。Ct的(de)變化很大,
可由設備的類型而定(ding)。
典型數據如下:
簡單的棒(bang)式(shi)或懸式(shi)絕(jue)緣子(zi) 幾十微法(fa)
簡單的(de)分級套(tao)管 100~1000pF
電壓互(hu)感器 200 ~ 500pF
電力變壓器 < 1000kVA~1000pF
> 1000kVA 1000~10000pF
高壓電力電纜和油浸紙絕緣 250~300pF/m
氣體絕緣 ~60pF/m
封閉變(bian)電站(zhan),SF6氣體絕緣 100~10000Pf;
對(dui)于不(bu)同(tong)的(de)試驗電壓Vn,選擇不(bu)同(tong)的(de)(適當的(de))**系數k。
以下列出不(bu)同(tong)的(de)Vn所(suo)選用的(de)k值供參(can)考。
Vn =50~100kV k = 4
Vn =150~300kV k = 3
Vn > 300kV k = 2
一(yi)、概(gai)述
工頻(pin)耐壓試驗(yan)是鑒定電(dian)力(li)設(she)備(bei)(bei)絕(jue)緣強度(du)的*嚴(yan)格、*有效和(he)*直接的方法。它能檢(jian)查出那(nei)些危險性(xing)較大(da)的集中缺陷,對判斷電(dian)力(li)設(she)備(bei)(bei)能否繼續參加運行(xing)具有決定性(xing)作(zuo)用,是保(bao)證設(she)備(bei)(bei)絕(jue)緣水平、避免發生絕(jue)緣事故的重要(yao)手段。
本裝置是根據國(guo)家*新電(dian)力行業標(biao)準(zhun)而設計的(de)、性能(neng)先進的(de)耐壓試(shi)驗設備,用于對各種電(dian)器(qi)產品(pin)、電(dian)氣元件、絕緣材料(liao)等(deng)進行規定電(dian)壓下的(de)絕緣強度試(shi)驗,以(yi)考核產品(pin)的(de)絕緣水平,發現被試(shi)品(pin)的(de)絕緣缺(que)陷,衡量過電(dian)壓的(de)能(neng)力。
二(er)、產品(pin)特點
監(jian)視功能:高(gao)壓(ya)電壓(ya) 低(di)壓(ya)電流 零位指(zhi)示(shi) 電源指(zhi)示(shi) 工作指(zhi)示(shi) 計時指(zhi)示(shi)
保(bao)護功能(neng):過流保(bao)護、零(ling)位啟(qi)動(dong)保(bao)護、聲光語言報(bao)警提醒(xing)
采用(yong)新型時(shi)間繼電器,計時(shi)范圍更(geng)廣(1S~99H)
采用新型(xing)電(dian)流(liu)繼電(dian)器,更**、更可(ke)靠,確保人(ren)身及設備**。
試(shi)驗變壓器高壓線圈為圓筒多層塔式,由上等(deng)聚酯漆包線及(ji)高耐壓值絕(jue)緣材(cai)料(liao)繞制而成。
試(shi)驗變壓器(5kVA以上(shang))裝有(you)可移動(dong)的(de)鐵輪。具有(you)重量輕、體積小、移動(dong)方便、性能優越(yue)等特點。
三、設備組成
1、選型配置
標(biao)準配置
|
□ 分體式
|
操作(zuo)部分:
□箱式(shi)(不大于5kVA) / □臺式(shi)
容量: kVA(小于200kVA)
輸(shu)入(ru):□AC220V / □AC380V
|
試驗(yan)變壓器:
□交(jiao)流 / □交(jiao)直(zhi)流
□油(you)變(bian) / □干變(bian) / □氣變(bian)
容量(liang): kVA(小(xiao)于(yu)200kVA)
輸(shu)出:AC kV(小于(yu)300kVA)
|
□ 一體(ti)式(shi)
|
□箱式(不(bu)大于(yu)20kV) / □臺式(不(bu)大于(yu)30kV)
容量: kVA(小(xiao)于300kVA)
輸(shu)(shu)入:□AC220V / □AC380V 輸(shu)(shu)出:AC kV(不大于30kV)
|
客(ke)戶選配
|
□標準(zhun)高壓(ya)分壓(ya)器
|
□保(bao)護球隙
|
□直(zhi)流微安表(biao)
|
□放**
|
□保護水阻
|
□高(gao)壓濾波(bo)電容
|
其它(ta):
|
2、對應實物
四、技術指標
1、使用(yong)條件:
(1)工作場所應無嚴重(zhong)影響絕緣的氣體(ti)、蒸汽、化學(xue)性(xing)(xing)塵(chen)埃及其它爆炸性(xing)(xing)和腐蝕性(xing)(xing)介質(zhi)。
(2)環境溫度 -20~+50℃
(3)環(huan)境濕(shi)度 ≤85% RH(無(wu)凝結(jie)水)
2、控制箱(xiang)(臺(tai))參數(shu):(常規參數(shu)見下表)
規格
|
容量
|
輸 入 電 源
|
輸(shu) 出 電 壓
|
重量(liang)(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說明:如有特殊參(can)數要求,可按用戶的技術參(can)數進行設計制(zhi)作(zuo)。
3、試驗變(bian)壓器(qi)參(can)數:(常規參(can)數見下表)
規(gui)格
|
容量
kVA
|
低壓側
|
高(gao)壓側
|
高壓(ya)側(交(jiao)直流變壓(ya)器(qi))
|
測量變比
|
60分鐘溫升℃
|
阻抗(kang)電壓%
|
空載電流
%
|
質量
kg
|
電壓(ya)
V
|
電(dian)流
A
|
交流輸出
|
直流輸出(chu)
|
電(dian)壓(ya)kV
|
電流(liu)
|
電壓kV
|
電(dian)流(liu)
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如有特(te)殊參(can)數要求,可(ke)按用戶的技術參(can)數進行設計制作。
上表的(de)重量(liang)以油(you)浸(jin)式試(shi)驗變(bian)壓(ya)器為例,干式試(shi)驗變(bian)壓(ya)器和充氣式試(shi)驗變(bian)壓(ya)器稍有(you)不同(tong)。
五(wu)、接線及工作原理
1、調(diao)壓(ya)部分接線(xian)及原理
調壓(ya)部(bu)(bu)分由(you)控(kong)(kong)制(zhi)部(bu)(bu)分和試驗(yan)(yan)變(bian)壓(ya)器組成。控(kong)(kong)制(zhi)部(bu)(bu)分是(shi)由(you)接觸式調壓(ya)器及其控(kong)(kong)制(zhi)、保護、測(ce)量(liang)、信號電路組成。試驗(yan)(yan)變(bian)壓(ya)器由(you)低壓(ya)繞(rao)(rao)組、高壓(ya)繞(rao)(rao)組、儀(yi)表繞(rao)(rao)組三部(bu)(bu)分組成。
試驗變(bian)(bian)(bian)壓器(qi)為交(jiao)直(zhi)(zhi)流兩用時(shi)(shi),試驗變(bian)(bian)(bian)壓器(qi)配置了高壓硅堆(dui)(油(you)變(bian)(bian)(bian)、氣變(bian)(bian)(bian)為內置,干(gan)變(bian)(bian)(bian)為外置),高壓可輸出(chu)交(jiao)流和(he)直(zhi)(zhi)流。輸出(chu)交(jiao)流時(shi)(shi),要求接入(ru)短(duan)路桿(gan)(油(you)變(bian)(bian)(bian)、氣變(bian)(bian)(bian))或(huo)去掉外置硅堆(dui)(干(gan)變(bian)(bian)(bian));輸出(chu)直(zhi)(zhi)流時(shi)(shi),要求擰出(chu)短(duan)路桿(gan)(油(you)變(bian)(bian)(bian)、氣變(bian)(bian)(bian))或(huo)加(jia)上外置硅堆(dui)(干(gan)變(bian)(bian)(bian))
通(tong)過接入工頻(pin)電(dian)源,調(diao)節調(diao)壓(ya)器,以獲得所需要(yao)的(de)試驗(yan)高壓(ya)電(dian)壓(ya)值。其工作原理見圖(tu)1:
2、試驗部分接(jie)線及原理
做(zuo)耐壓(ya)(ya)試(shi)驗(yan)時,控制(zhi)部分、變壓(ya)(ya)器的接(jie)(jie)地(di)端及(ji)高壓(ya)(ya)尾(wei)必須(xu)可(ke)靠接(jie)(jie)地(di)。有條件的情況下,做(zuo)工(gong)頻耐壓(ya)(ya)試(shi)驗(yan)請(qing)加上限流電阻、標(biao)準高壓(ya)(ya)分壓(ya)(ya)器、球(qiu)隙保護電阻及(ji)保護球(qiu)隙,如圖3。
做直流(liu)耐壓(ya)試驗(yan)請(qing)另外加(jia)上(shang)微(wei)安(an)表,微(wei)安(an)表必須接(jie)在(zai)硅(gui)堆(dui)(dui)和(he)(he)被試器(qi)(qi)之間(jian),油變(bian)(bian)或氣變(bian)(bian)一(yi)般擰在(zai)高壓(ya)頭上(shang)面(mian)(要求擰出短路桿),干變(bian)(bian)擰在(zai)外置硅(gui)堆(dui)(dui)上(shang)面(mian);為(wei)了更準確顯(xian)示高壓(ya)直流(liu)泄(xie)漏電流(liu),請(qing)將分壓(ya)器(qi)(qi)的高壓(ya)線接(jie)在(zai)微(wei)安(an)表和(he)(he)硅(gui)堆(dui)(dui)之間(jian),(油變(bian)(bian)、氣變(bian)(bian))如圖(tu)4,(干變(bian)(bian))如圖(tu)5。
耐壓試(shi)(shi)驗(yan)中限(xian)流(liu)(liu)電(dian)(dian)阻(zu)(zu)(zu)R1應(ying)根據試(shi)(shi)驗(yan)變壓器的額(e)定容量(liang)來選擇。如高(gao)壓側額(e)定輸出電(dian)(dian)流(liu)(liu)在100~300mA時(shi),可(ke)取0.5~1Ω/V(試(shi)(shi)驗(yan)電(dian)(dian)壓);高(gao)壓側額(e)定輸出電(dian)(dian)流(liu)(liu)為1A以上時(shi),可(ke)取1Ω/V(試(shi)(shi)驗(yan)電(dian)(dian)壓)。常用(yong)水(shui)電(dian)(dian)阻(zu)(zu)(zu)作為限(xian)流(liu)(liu)電(dian)(dian)阻(zu)(zu)(zu),管(guan)子(zi)長度可(ke)按(an)150kV/m考慮,管(guan)子(zi)粗細(xi)應(ying)具有足(zu)夠的熱(re)容量(liang)(水(shui)阻(zu)(zu)(zu)液配(pei)制方(fang)法:用(yong)蒸餾水(shui)加入適量(liang)硫(liu)酸銅配(pei)制成各種不(bu)同的阻(zu)(zu)(zu)值)。
球間隙(xi)(xi)及(ji)保(bao)護電(dian)(dian)阻(zu):當電(dian)(dian)壓超(chao)過球間隙(xi)(xi)整定值時(一般(ban)取試(shi)驗(yan)電(dian)(dian)壓的110%~120%),球間隙(xi)(xi)放(fang)電(dian)(dian),對被試(shi)品起到保(bao)護作用。球間隙(xi)(xi)保(bao)護電(dian)(dian)阻(zu)可按(an)1Ω/V(試(shi)驗(yan)電(dian)(dian)壓)選(xuan)取。
在工頻耐(nai)壓(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)中,低電(dian)(dian)壓(ya)(ya)(ya)(ya)側測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)(儀表(biao)電(dian)(dian)壓(ya)(ya)(ya)(ya))不(bu)是非常準確(que)的(de),其(qi)原因是由于(yu)(yu)試(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)器存(cun)在著(zhu)漏抗,在這個(ge)漏抗上必然(ran)存(cun)在著(zhu)壓(ya)(ya)(ya)(ya)降(jiang)或容升,使(shi)試(shi)(shi)品(pin)上的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)低于(yu)(yu)或高(gao)(gao)于(yu)(yu)低壓(ya)(ya)(ya)(ya)側測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)表(biao)上反(fan)映出來的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)。工頻耐(nai)壓(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)時(shi),被試(shi)(shi)品(pin)上的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)高(gao)(gao)于(yu)(yu)試(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)器的(de)輸出電(dian)(dian)壓(ya)(ya)(ya)(ya),也就(jiu)是所(suo)謂容升現象。感應耐(nai)壓(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)時(shi),試(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)器的(de)漏抗必然(ran)存(cun)在著(zhu)壓(ya)(ya)(ya)(ya)降(jiang)。為了準確(que)測(ce)量被試(shi)(shi)品(pin)上所(suo)施加(jia)的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya),因此常在高(gao)(gao)壓(ya)(ya)(ya)(ya)側接入(ru)標準高(gao)(gao)壓(ya)(ya)(ya)(ya)分壓(ya)(ya)(ya)(ya)器來測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)。
五(wu)、面(mian)板結構說(shuo)明
1、操作箱面板
控制箱(xiang)為箱(xiang)式鋁(lv)合金結構,面(mian)板采用拉絲鋁(lv)合金工藝,所有電(dian)器元件均裝(zhuang)在骨架上,便于(yu)安裝(zhuang)和維修(xiu)。面(mian)板元件布置(zhi)如下:
2、操作臺面(mian)板
操作(zuo)臺為(wei)臺式結構(gou),殼(ke)體為(wei)冷扎鋼板(ban)結構(gou),面(mian)板(ban)采(cai)用鋁合金拉絲工(gong)藝(yi),面(mian)板(ban)元件(jian)布置(zhi)如(ru)下(xia):
六(liu)、操(cao)作指南
本(ben)裝置在操作之前應(ying)根據(ju)不同被試品的(de)容量、電壓(ya)等級,先(xian)計算(suan)好(hao)*大工作電流,并調整電流保護器。其試驗接線應(ying)參考本(ben)說明書中圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5,必須可靠接地。
1、操作要點(dian)
(1)試驗(yan)(yan)前,應(ying)了(le)(le)解(jie)被(bei)試品(pin)(pin)的試驗(yan)(yan)電(dian)壓(ya),同時了(le)(le)解(jie)被(bei)試品(pin)(pin)的其(qi)他試驗(yan)(yan)項(xiang)目(mu)及以前的試驗(yan)(yan)結果。若(ruo)被(bei)試品(pin)(pin)有缺(que)陷或異常,應(ying)在消除后再進行耐壓(ya)試驗(yan)(yan)。
(2)試驗(yan)現場應圍好(hao)遮攔或圍繩(sheng),掛好(hao)標示牌(pai),并派專人(ren)監護。
(3)試(shi)(shi)驗前(qian),被(bei)試(shi)(shi)品表面應(ying)(ying)擦(ca)拭(shi)干凈,將(jiang)被(bei)試(shi)(shi)品的外(wai)殼和非(fei)被(bei)試(shi)(shi)繞組可靠接地。被(bei)試(shi)(shi)品為新沖油(you)設(she)備時(shi)(shi)(shi),應(ying)(ying)按《規程》規定(ding)使油(you)靜止一定(ding)時(shi)(shi)(shi)間再升壓,對(dui)110kV及以下(xia)的充油(you)電(dian)力(li)設(she)備,在(zai)注滿油(you)后靜置時(shi)(shi)(shi)間應(ying)(ying)不(bu)(bu)少(shao)于24小(xiao)時(shi)(shi)(shi),對(dui)220kV及330kV的充油(you)電(dian)力(li)設(she)備,靜置時(shi)(shi)(shi)間應(ying)(ying)不(bu)(bu)少(shao)于48小(xiao)時(shi)(shi)(shi)。
(4)接好試驗(yan)接線后,應由有經驗(yan)的人員檢查,確認無(wu)誤后方可(ke)升(sheng)壓。
(5)升壓前,首先檢查調壓器是否(fou)在零位。調壓器在零位方可升壓。
(6)升壓(ya)過(guo)程中不僅要(yao)監視電(dian)壓(ya)表(biao)的變化(hua),還應(ying)監視電(dian)流表(biao)的變化(hua),以及被試(shi)品電(dian)流的變化(hua)。升壓(ya)時(shi)要(yao)均(jun)勻升壓(ya),不能太快。升至規定試(shi)驗(yan)電(dian)壓(ya)時(shi),開(kai)(kai)始計算時(shi)間(jian),時(shi)間(jian)到(dao)后,緩(huan)慢均(jun)勻降下電(dian)壓(ya)。絕不允(yun)許不降壓(ya)就先跳開(kai)(kai)電(dian)源開(kai)(kai)關(guan)。
(7)試(shi)驗中(zhong)發現表針擺動或被試(shi)品有異(yi)常聲響、冒煙等應立即降下電(dian)壓(ya)(ya),拉開電(dian)源,在高(gao)壓(ya)(ya)側掛上(shang)接地線后(hou),再查明原因。
(8)耐壓(ya)試驗前后均應測量被試品的(de)絕緣(yuan)電阻。
2、操作步(bu)驟
(1) 按試驗要求將控(kong)制部分(fen)、試驗變壓器(qi)、被試品(pin)正確接好線,必須(xu)可靠(kao)接地(di),請參考圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5。
(2) 根(gen)據(ju)試驗的要求,整(zheng)定“時(shi)間繼電(dian)器(qi)”及(ji)“過流繼電(dian)器(qi)”。
A 時間繼電器設置(zhi):
T1,T2,T3,T4設置0~9任意(yi)數字,T可設置為H(小(xiao)時),M(分鐘),S(秒)。
根據試驗要求,在1S~99H內可以任意設置定時(shi)時(shi)間。
B 過流(liu)繼電器(qi)設置:
過流(liu)動(dong)作設定值(zhi)(zhi)=過流(liu)繼電(dian)(dian)器(qi)刻(ke)度盤讀數×測量(liang)變(bian)比×K,其中K為電(dian)(dian)流(liu)倍率/切除(chu)開關的狀態值(zhi)(zhi),分別為X1,X2,OFF,電(dian)(dian)流(liu)倍率/切除(chu)開關處于(yu)×1,×2位置時(shi),K值(zhi)(zhi)分別為1、2,切換為OFF擋時(shi),K值(zhi)(zhi)為+∞。(注(zhu):不(bu)要使用OFF檔,因為會使變(bian)壓器(qi)失去過流(liu)保護功能而(er)導致(zhi)設備損(sun)壞。測量(liang)變(bian)比為電(dian)(dian)流(liu)互感器(qi)的變(bian)比,沒(mei)有電(dian)(dian)流(liu)互感器(qi)時(shi)為1)。
(3) 接入電(dian)源(yuan),此時,“電(dian)源(yuan)燈”亮(liang),表示外部電(dian)源(yuan)已引入。如“零(ling)位燈”亮(liang),表示調(diao)(diao)壓(ya)器在零(ling)位。如“零(ling)位燈”不(bu)亮(liang),應逆(ni)時針旋轉調(diao)(diao)節(jie)調(diao)(diao)壓(ya)器手(shou)柄至“零(ling)位燈”亮(liang),表示可進行調(diao)(diao)壓(ya)操作(zuo)。
(4)按(an)“啟動(dong)按(an)鈕”。此時,“送(song)電(dian)燈(deng)”,“電(dian)源(yuan)燈(deng)”和“零(ling)位燈(deng)”亮;進入送(song)電(dian)狀態(tai)。
(5)以2kV/S勻速順(shun)時針旋轉調壓器手柄至被(bei)試(shi)(shi)品(pin)規(gui)定的(de)耐壓值,并密切(qie)(qie)注視電(dian)(dian)流(liu)表(直(zhi)(zhi)流(liu)耐壓試(shi)(shi)驗時,同時密切(qie)(qie)注視直(zhi)(zhi)流(liu)微安表)。此時,“電(dian)(dian)源燈”,“工作燈”亮;“零位燈”滅。
(6)根據(ju)試驗啟動“計時(shi)按鈕”,計時(shi)開(kai)始,并注意(yi)被試品(pin)的情(qing)況。
(7)當耐壓計時(shi)到時(shi),操作臺自(zi)動聲光報警(jing)。應立即逆時(shi)針旋(xuan)轉(zhuan)調壓器手柄至零位,按下停止按鈕和解除計時(shi)按鈕自(zi)鎖(suo)狀態。此時(shi)“電源燈(deng)(deng)”, “零位燈(deng)(deng)”亮,“工作燈(deng)(deng)”滅。試驗即告完畢
(8)拔掉電源,拆(chai)除(chu)接線(xian),試(shi)驗結束。
(9)在(zai)升壓或耐壓過(guo)程中,如發(fa)生短路、閃(shan)絡、擊穿過(guo)流時(shi),過(guo)流繼電(dian)器(qi)動作(zuo),切(qie)斷(duan)主回(hui)路。此時(shi)應將調壓器(qi)逆時(shi)針旋轉至零位,切(qie)斷(duan)電(dian)源,并查明(ming)原因(yin),并作(zuo)詳細記錄。
(10)試驗完(wan)畢,降(jiang)壓,切斷電源后應用放**將被(bei)試品(pin)及試驗裝置本(ben)身充分放電。
七(qi)、產(chan)品(pin)維(wei)護
1、開(kai)箱驗收時(shi),應檢查主控(kong)回(hui)路接線是否(fou)松(song)動,調壓器電刷是否(fou)接觸良好;
2、長期不(bu)用時,使用前應用500V兆歐表測量(liang)絕緣(yuan)電(dian)阻,其阻值不(bu)低于0.5MΩ;
3、電源電壓應(ying)符合控(kong)制箱(xiang)(臺)銘牌(pai)上的輸入電壓值;
4、本裝置設(she)有過電流(liu)(liu)保護,出廠已(yi)調整為(wei)額定(ding)電流(liu)(liu)的50%。用于小(xiao)負載(zai)時,應根據被試品的額定(ding)容量(liang)電流(liu)(liu)重(zhong)新(xin)設(she)定(ding);
5、使(shi)用完畢(bi)后,應關好控(kong)制(zhi)箱(xiang)(臺)門,以保持控(kong)制(zhi)箱(xiang)(臺)內部清潔(jie)。
八(ba)、注意事項
1、按照您所進(jin)行的(de)試驗(yan)接好工作(zuo)線路。試驗(yan)變壓(ya)器的(de)外殼以(yi)及操作(zuo)系統(tong)的(de)外殼必須可靠接地。試驗(yan)變壓(ya)器的(de)高壓(ya)繞組(zu)的(de)X端(高壓(ya)尾)以(yi)及測量繞組(zu)的(de)F端必須可靠接地。
2、做(zuo)串級(ji)試驗(yan)時,**級(ji)、第三級(ji)試驗(yan)變壓(ya)(ya)(ya)(ya)器的低(di)壓(ya)(ya)(ya)(ya)繞(rao)組成X端(duan),測量(liang)繞(rao)組的F端(duan)以及高(gao)壓(ya)(ya)(ya)(ya)繞(rao)組的X端(duan)(高(gao)壓(ya)(ya)(ya)(ya)端(duan))均(jun)接本級(ji)試驗(yan)變壓(ya)(ya)(ya)(ya)器具外(wai)殼(ke)。**級(ji)、第三級(ji)試驗(yan)變壓(ya)(ya)(ya)(ya)器的外(wai)殼(ke)必須通過絕(jue)緣(yuan)支架接地。
3、接通電(dian)源(yuan)(yuan)前,操作系統的(de)(de)調(diao)壓(ya)(ya)器必須調(diao)到(dao)零位后(hou)(hou)方(fang)可(ke)接通電(dian)源(yuan)(yuan),合(he)閘,開始升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)。從零開始勻速旋轉調(diao)壓(ya)(ya)器手輪升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)。升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)方(fang)式有(you):快速升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)法(fa)(fa),即(ji)20s逐級(ji)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)法(fa)(fa);慢速升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)法(fa)(fa),即(ji)60s逐級(ji)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)法(fa)(fa);極慢速升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)法(fa)(fa)供(gong)選用(yong)。電(dian)壓(ya)(ya)從零開始按一定的(de)(de)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)方(fang)式和速度上升(sheng)(sheng)(sheng)(sheng)到(dao)您所需的(de)(de)額定試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)電(dian)壓(ya)(ya)的(de)(de)75%后(hou)(hou),再以(yi)每秒2%額定試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)電(dian)壓(ya)(ya)的(de)(de)速度升(sheng)(sheng)(sheng)(sheng)到(dao)您所需的(de)(de)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)電(dian)壓(ya)(ya),并密切注意測量儀(yi)表的(de)(de)及被試(shi)(shi)(shi)(shi)(shi)品(pin)的(de)(de)情(qing)況。升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)過(guo)程(cheng)(cheng)中或試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)過(guo)程(cheng)(cheng)中如發現測量儀(yi)表的(de)(de)指示及被試(shi)(shi)(shi)(shi)(shi)品(pin)情(qing)況異常,應立即(ji)降壓(ya)(ya),切斷(duan)電(dian)源(yuan)(yuan),查明情(qing)況。
4、試驗(yan)完畢后,應在數秒內勻速的將調(diao)壓器(qi)返(fan)回至(zhi)零位,然后切(qie)斷電源。本產品不得(de)超過(guo)額定參(can)數使用。
5、使(shi)用本(ben)(ben)產品(pin)做高(gao)壓試(shi)(shi)驗(yan)時,除熟悉本(ben)(ben)說明書外,還(huan)必須(xu)嚴格(ge)執(zhi)行國(guo)家有關標準和(he)操作(zuo)規程。可(ke)參照GB311.1 – 97《高(gao)壓輸(shu)變設備的絕緣配合,高(gao)壓試(shi)(shi)驗(yan)技術》;《電氣設備預防性試(shi)(shi)驗(yan)規程》等
一、概(gai)述
智(zhi)能(neng)耐(nai)壓(ya)試(shi)驗裝置是根(gen)據(ju)國家*新電力行(xing)業標準而設計的(de)、性(xing)能(neng)先(xian)進的(de)智(zhi)能(neng)型耐(nai)壓(ya)試(shi)驗設備(bei),用于對各種電器(qi)產(chan)品、電氣元(yuan)件、絕(jue)緣(yuan)材(cai)料等進行(xing)規定電壓(ya)下(xia)的(de)絕(jue)緣(yuan)強度試(shi)驗,以考核產(chan)品的(de)絕(jue)緣(yuan)水平,發現被(bei)試(shi)品的(de)絕(jue)緣(yuan)缺陷,衡量過電壓(ya)的(de)能(neng)力。廣泛應用于電工制造(zao)部門、電力運行(xing)部門、科研單位和高等院校。
二、產品特點
1. 320×240液晶(jing)顯示器、高速熱(re)敏打印機(ji)。
2. 高壓(ya)電壓(ya)、高壓(ya)電流(liu)、低(di)壓(ya)電壓(ya)、低(di)壓(ya)電流(liu)4路測(ce)量(liang)方(fang)式,高精度傳感器和高性(xing)能(neng)14位AD采集芯(xin)片(pian)。
3. 人(ren)機對話全(quan)鍵盤操作方式,智能化工(gong)作全(quan)過(guo)程,任(ren)選自動方式和手動方式。
4. 實時顯示(shi)高壓(ya)(ya)電(dian)壓(ya)(ya)、高壓(ya)(ya)電(dian)流(liu)、低壓(ya)(ya)電(dian)壓(ya)(ya)、低壓(ya)(ya)電(dian)流(liu),時間及耐壓(ya)(ya)結(jie)果,顯示(shi)直觀(guan)明了。
5. 完善的過壓(ya)、過流保護,任意設定輸出電壓(ya)、高壓(ya)電流上限(xian)、低壓(ya)電流上限(xian)和計時(shi)時(shi)間。
6. 具有回零檢測功(gong)能,回零確定(ding)后才可(ke)進行試驗,**可(ke)靠(kao)。
7. 具有絕緣(yuan)電阻(zu)測(ce)試(shi)功能,直(zhi)接反(fan)映被試(shi)品(pin)絕緣(yuan)強度。
8. 逼(bi)近式(shi)調壓(ya)算法(fa),到(dao)達(da)設定電(dian)壓(ya)后自動耐壓(ya)計時,計時結束后自動降壓(ya)回零(ling)。
9. 超過(guo)設定高壓電(dian)(dian)流(liu)或(huo)低壓電(dian)(dian)流(liu)時自動切(qie)斷電(dian)(dian)壓輸出,降壓回零,并發生聲光報警。
10. 精良的軟硬件抗(kang)干(gan)擾(rao)設(she)計(ji),多種抗(kang)干(gan)擾(rao)手段,適應惡劣電磁環境(jing)。
11. 自動(dong)錯誤診(zhen)斷,易于發現和(he)解決問題。
12. 可選配無線遙控控制功能(neng)、遠程(cheng)通信、門聯鎖警鈴、外(wai)接(jie)分壓器校驗接(jie)口(kou)等。
三(san)、設(she)備組成
1、選型配置(zhi)
標準配置
|
□ 分體式
|
操作部分(fen):
□箱式(不大于5kVA) / □臺式
容量: kVA(小于200kVA)
輸入:□AC220V / □AC380V
|
試驗變壓(ya)器:
□交(jiao)流(liu) / □交(jiao)直流(liu)
□油變 / □干(gan)變 / □氣變
容量(liang): kVA(小于200kVA)
輸出:AC kV(小于300kVA)
|
□ 一體式
|
□箱式(不大于20kV) / □臺式(不大于30kV)
容量: kVA(小于300kVA)
輸入(ru):□AC220V / □AC380V 輸出(chu):AC kV(不大于30kV)
|
客戶選配
|
□標準高(gao)壓(ya)分壓(ya)器
|
□保護球隙
|
□直流微安表(biao)
|
□放(fang)**
|
□保護水阻
|
□高壓濾波電容(rong)
|
其它:
|
2、對(dui)應實物
四、技術(shu)指標
1、使用條件:
(1)工作場所應無嚴重影響絕緣的(de)氣體、蒸(zheng)汽、化學性(xing)塵埃(ai)及其它爆炸(zha)性(xing)和腐蝕性(xing)介質。
(2)環境(jing)溫度 -20~+50℃
(3)環境濕度 ≤85% RH(無凝結水)
2、控(kong)制(zhi)箱(xiang)(臺)參(can)數:(常(chang)規參(can)數見下(xia)表)
(1)計時范圍(wei):0-999S
(3)電壓精度 ≤1.5% ±1個(ge)字(F.S)
(4)電(dian)流精度 ≤1.5% ±1個字(zi)(F.S)
規格
|
容量(liang)
|
輸 入(ru) 電(dian) 源
|
輸(shu) 出 電 壓(ya)
|
重量(liang)(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說明(ming):如有特殊參數要求,可(ke)按用戶(hu)的技術參數進(jin)行設計制作。
3、試驗(yan)變壓器參(can)數(shu):(常規參(can)數(shu)見下(xia)表)
規格
|
容(rong)量(liang)
kVA
|
低(di)壓側
|
高(gao)壓側
|
高壓側(交直流變壓器)
|
測量變比
|
60分鐘溫升(sheng)℃
|
阻抗電壓%
|
空載電流
%
|
質(zhi)量
kg
|
電壓
V
|
電流
A
|
交流輸出
|
直流輸(shu)出(chu)
|
電(dian)壓kV
|
電流
|
電壓kV
|
電流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如有特殊參(can)數要求,可按用(yong)戶的(de)技術參(can)數進(jin)行設計制作(zuo)。
上表的重量以油浸式(shi)(shi)試驗(yan)變(bian)壓器為例,干式(shi)(shi)試驗(yan)變(bian)壓器和充氣式(shi)(shi)試驗(yan)變(bian)壓器稍有不同(tong)。
五、接線及工(gong)作原理(li)
1、調壓(ya)部(bu)分接線及(ji)原理
調(diao)壓(ya)部分(fen)由(you)控(kong)制部分(fen)和試(shi)驗變(bian)壓(ya)器組(zu)(zu)成(cheng)。控(kong)制部分(fen)是由(you)接觸式調(diao)壓(ya)器、單片(pian)機控(kong)制系統、液(ye)晶(jing)、打(da)印機、信號測量、電路保護(hu)組(zu)(zu)成(cheng)。試(shi)驗變(bian)壓(ya)器由(you)低壓(ya)繞(rao)組(zu)(zu)、高壓(ya)繞(rao)組(zu)(zu)、儀(yi)表繞(rao)組(zu)(zu)三部分(fen)組(zu)(zu)成(cheng)。
試(shi)驗變(bian)(bian)壓(ya)(ya)器為(wei)交(jiao)直流兩用時(shi),試(shi)驗變(bian)(bian)壓(ya)(ya)器配(pei)置(zhi)了高(gao)壓(ya)(ya)硅(gui)堆(油(you)變(bian)(bian)、氣變(bian)(bian)為(wei)內置(zhi),干(gan)變(bian)(bian)為(wei)外(wai)置(zhi)),高(gao)壓(ya)(ya)可輸(shu)出交(jiao)流和直流。輸(shu)出交(jiao)流時(shi),要(yao)求接(jie)入短路桿(油(you)變(bian)(bian)、氣變(bian)(bian))或(huo)去掉外(wai)置(zhi)硅(gui)堆(干(gan)變(bian)(bian));輸(shu)出直流時(shi),要(yao)求擰出短路桿(油(you)變(bian)(bian)、氣變(bian)(bian))或(huo)加上(shang)外(wai)置(zhi)硅(gui)堆(干(gan)變(bian)(bian))
通過(guo)接入(ru)工頻電源,調節調壓(ya)器,以獲得所(suo)需要的(de)試驗高壓(ya)電壓(ya)值。其工作原理(li)見圖1:
2、試驗(yan)部分(fen)接線(xian)及原理
做(zuo)耐(nai)壓試驗時(shi),控制部分、變壓器的接地端及高壓尾(wei)必須可靠接地。有條件的情況下,做(zuo)工頻耐(nai)壓試驗請加上限(xian)流電(dian)阻(zu)、標準(zhun)高壓分壓器、球隙保護(hu)電(dian)阻(zu)及保護(hu)球隙,如圖3。
做直流(liu)耐壓(ya)(ya)試(shi)驗請另外(wai)加上微(wei)安表,微(wei)安表必(bi)須接(jie)在(zai)硅(gui)堆(dui)和(he)被試(shi)器之間(jian)(jian),油(you)變或氣變一般(ban)擰在(zai)高壓(ya)(ya)頭上面(mian)(要求擰出短路(lu)桿(gan)),干(gan)變擰在(zai)外(wai)置硅(gui)堆(dui)上面(mian);為了更準確顯示高壓(ya)(ya)直流(liu)泄漏電(dian)流(liu),請將分壓(ya)(ya)器的高壓(ya)(ya)線接(jie)在(zai)微(wei)安表和(he)硅(gui)堆(dui)之間(jian)(jian),(油(you)變、氣變)如圖(tu)4,(干(gan)變)如圖(tu)5。
耐壓(ya)試驗中限流電(dian)阻R1應(ying)根據試驗變(bian)壓(ya)器(qi)的(de)額定容(rong)量來選擇(ze)。如高壓(ya)側(ce)額定輸出電(dian)流在(zai)100~300mA時,可取0.5~1Ω/V(試驗電(dian)壓(ya));高壓(ya)側(ce)額定輸出電(dian)流為1A以上時,可取1Ω/V(試驗電(dian)壓(ya))。常用水電(dian)阻作為限流電(dian)阻,管(guan)子(zi)長度可按150kV/m考(kao)慮,管(guan)子(zi)粗細(xi)應(ying)具有足夠(gou)的(de)熱容(rong)量(水阻液(ye)配制(zhi)(zhi)方法(fa):用蒸餾水加入適量硫酸銅配制(zhi)(zhi)成各種不同(tong)的(de)阻值(zhi))。
球間隙(xi)(xi)及保(bao)護(hu)電(dian)(dian)阻(zu):當電(dian)(dian)壓超過球間隙(xi)(xi)整(zheng)定值時(一般取試驗電(dian)(dian)壓的110%~120%),球間隙(xi)(xi)放電(dian)(dian),對被試品起到保(bao)護(hu)作用。球間隙(xi)(xi)保(bao)護(hu)電(dian)(dian)阻(zu)可(ke)按1Ω/V(試驗電(dian)(dian)壓)選(xuan)取。
在(zai)(zai)工頻耐壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)驗中,低(di)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)測(ce)量電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(儀表(biao)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya))不(bu)是(shi)非常準(zhun)確的,其原(yuan)因(yin)是(shi)由(you)于試(shi)驗變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)存在(zai)(zai)著(zhu)漏(lou)(lou)抗(kang),在(zai)(zai)這個漏(lou)(lou)抗(kang)上必然(ran)存在(zai)(zai)著(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)降(jiang)或容(rong)升(sheng),使試(shi)品上的電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)低(di)于或高(gao)于低(di)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)測(ce)量電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)表(biao)上反映(ying)出(chu)來的電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)。工頻耐壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)驗時,被(bei)試(shi)品上的電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)高(gao)于試(shi)驗變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)的輸出(chu)電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya),也(ye)就是(shi)所(suo)謂(wei)容(rong)升(sheng)現象。感應耐壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)驗時,試(shi)驗變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)的漏(lou)(lou)抗(kang)必然(ran)存在(zai)(zai)著(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)降(jiang)。為了準(zhun)確測(ce)量被(bei)試(shi)品上所(suo)施加的電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya),因(yin)此常在(zai)(zai)高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)接入標準(zhun)高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)分壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)來測(ce)量電(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)。
六、操作要點
1、試(shi)驗前,應了(le)解被試(shi)品的(de)試(shi)驗電壓,同時了(le)解被試(shi)品的(de)其他試(shi)驗項(xiang)目及以前的(de)試(shi)驗結果。若被試(shi)品有缺陷或異常(chang),應在消除后再進行耐壓試(shi)驗。
2、試驗現場應圍(wei)好遮攔(lan)或圍(wei)繩,掛好標示(shi)牌,并派專人(ren)監護。
3、試(shi)(shi)(shi)驗(yan)前,被(bei)(bei)試(shi)(shi)(shi)品表面應(ying)(ying)擦(ca)拭(shi)干(gan)凈(jing),將被(bei)(bei)試(shi)(shi)(shi)品的外(wai)殼和非被(bei)(bei)試(shi)(shi)(shi)繞組可靠接地。被(bei)(bei)試(shi)(shi)(shi)品為(wei)新(xin)沖(chong)油(you)(you)(you)設備(bei)時(shi),應(ying)(ying)按《規程》規定使油(you)(you)(you)靜(jing)(jing)止一定時(shi)間再升壓,對110kV及以下的充油(you)(you)(you)電力設備(bei),在注(zhu)滿(man)油(you)(you)(you)后(hou)靜(jing)(jing)置時(shi)間應(ying)(ying)不少(shao)于24小(xiao)時(shi),對220kV及330kV的充油(you)(you)(you)電力設備(bei),靜(jing)(jing)置時(shi)間應(ying)(ying)不少(shao)于48小(xiao)時(shi)。
4、接(jie)好試驗(yan)接(jie)線后,應(ying)由有(you)經(jing)驗(yan)的人員(yuan)檢查,確認無(wu)誤(wu)后方(fang)可升壓。
5、升壓(ya)前,首(shou)先檢查調壓(ya)器是否(fou)在(zai)零位(wei)。調壓(ya)器在(zai)零位(wei)方可升壓(ya)。
6、升(sheng)壓過程中(zhong)不(bu)僅要(yao)(yao)監視(shi)電壓的(de)變(bian)化,還應監視(shi)電流的(de)變(bian)化,以及被試品泄(xie)漏(lou)電流的(de)變(bian)化。升(sheng)壓時(shi)要(yao)(yao)均勻(yun)升(sheng)壓,不(bu)能太(tai)快。升(sheng)至規定(ding)試驗電壓時(shi),開始(shi)計時(shi),時(shi)間(jian)到后,緩慢(man)均勻(yun)降下電壓。絕不(bu)允許不(bu)降壓就先跳開電源開關(guan)。
7、試(shi)驗(yan)中(zhong)發(fa)現(xian)被(bei)試(shi)品有異常聲響、冒煙(yan)等應立即(ji)降下電(dian)壓(ya),拉(la)開(kai)電(dian)源(yuan),在高壓(ya)側掛上(shang)接地線后,再查(cha)明原因。耐(nai)壓(ya)試(shi)驗(yan)前后均應測量(liang)被(bei)試(shi)品的絕緣電(dian)阻。
七、面板功能說(shuo)明
打印機(ji):打印機(ji)是熱敏打印機(ji),當試驗完成后按(an)鍵盤上的“打印”按(an)鈕打印試驗結果(guo)。
RS232:RS232是與計算機相連的串口通信接口,是用戶選配(pei)接口,本裝置沒(mei)有配(pei)置這個接口。
LCD對比度(du)(du):因為液(ye)晶(jing)顯示屏在溫度(du)(du)和光線有所不同時(shi)稍有些變化(hua),可以通過(guo)LCD對比度(du)(du)調節背光到適(shi)合(he)亮度(du)(du)。
液晶: 320x240像素(su)點陣白(bai)色背光液晶,在(zai)強(qiang)光和陰暗環境(jing)下都十(shi)分清(qing)楚。
指示燈(deng):由啟動(dong)燈(deng)、零位(wei)燈(deng)、指示燈(deng)三個燈(deng)組成,啟動(dong)燈(deng)和(he)警(jing)示燈(deng)是高亮七彩(cai)燈(deng)。
操作提示:有一(yi)些簡短的提示語句和安裝接線圖。
緊急開關(guan):在緊急情況下按此開關(guan),即(ji)可(ke)以切(qie)斷(duan)變壓(ya)器(qi)電源,也(ye)可(ke)以切(qie)斷(duan)工作電源。(箱式(shi)安裝(zhuang)在面(mian)板上(shang),臺式(shi)安裝(zhuang)在柜體上(shang))
鍵(jian)盤:由上、下、左、右、設置、打印、確定(ding)、取消8個鍵(jian)組成,是用戶(hu)和(he)設備交互的終端(duan)。
電源開關:工作電源,帶通(tong)電指示燈。
八、軟件使用(yong)說明
按試驗要(yao)求將控(kong)制部分、試驗變壓器、被試品正確接好線(xian),必須可(ke)靠接地,請(qing)參(can)考圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5。
1、開機使用(yong)
開機處(chu)于“歡迎界面”,如圖7:
根據鍵盤的示圖8,按上↑、下↓、左←,右→可以切換(huan)“自動耐壓(ya)試驗(yan)”或“手動耐壓(ya)試驗(yan)”,在“自動試驗(yan)”或“手動試驗(yan)”里面選擇“交流試驗(yan)方式”或“直(zhi)流試驗(yan)方式”。如圖9
說明(ming):
(1)當配置的是交(jiao)直(zhi)流兩用(yong)控制部分時(shi),使用(yong)直(zhi)流輸出時(shi)軟件操(cao)(cao)作(zuo)請進入直(zhi)流試(shi)驗(yan)(yan)方式,交(jiao)流輸出時(shi)軟件操(cao)(cao)作(zuo)請進入交(jiao)流試(shi)驗(yan)(yan)方式,如果選擇錯(cuo)誤會導致儀器顯(xian)示電(dian)壓會和(he)輸出實際(ji)電(dian)壓不一致。
(2)當配置(zhi)的是交(jiao)直流兩(liang)用變壓器時,使用直流時請(qing)將(jiang)變壓器的短路(lu)桿取出(chu),當使用交(jiao)流時請(qing)將(jiang)短路(lu)桿插入擰緊。
(3)如(ru)(ru)果配置的是交流控制部(bu)分時(shi),軟件界面里就沒有交直流試驗方(fang)式(如(ru)(ru)圖9)的選擇項。
選(xuan)中試驗方式后,按確定可以進入(ru)主界面(mian),如圖10:
動態(tai)顯示區:一直處于采集信號,并顯示高壓(ya)電壓(ya)、高壓(ya)電流、低壓(ya)電壓(ya)、低壓(ya)電流。
結(jie)果顯示(shi)區:如果試驗(yan)沒有被擊穿時,顯示(shi)平(ping)均高壓(ya)電(dian)(dian)(dian)(dian)壓(ya),平(ping)均高壓(ya)電(dian)(dian)(dian)(dian)流(liu),平(ping)均低(di)(di)壓(ya)電(dian)(dian)(dian)(dian)壓(ya),平(ping)均低(di)(di)壓(ya)電(dian)(dian)(dian)(dian)流(liu),絕緣電(dian)(dian)(dian)(dian)阻;否之,顯示(shi)峰(feng)值電(dian)(dian)(dian)(dian)壓(ya),峰(feng)值電(dian)(dian)(dian)(dian)流(liu),低(di)(di)壓(ya)電(dian)(dian)(dian)(dian)壓(ya),低(di)(di)壓(ya)電(dian)(dian)(dian)(dian)流(liu)。
設置數(shu)據(ju)區(qu):設置試驗(yan)中需要的(de)參(can)數(shu)數(shu)據(ju)輸出電(dian)(dian)壓(ya)(ya)(ya)為在(zai)自(zi)動方式下的(de)升(sheng)壓(ya)(ya)(ya)目標(biao)耐壓(ya)(ya)(ya)值耐壓(ya)(ya)(ya)時間(jian)為耐壓(ya)(ya)(ya)過程的(de)時間(jian)長度電(dian)(dian)流(liu)上(shang)限(xian)為高壓(ya)(ya)(ya)電(dian)(dian)流(liu)峰值的(de)上(shang)限(xian),高壓(ya)(ya)(ya)電(dian)(dian)流(liu)超過電(dian)(dian)流(liu)上(shang)限(xian)將認(ren)為擊(ji)穿(chuan)過流(liu)保護為低(di)(di)壓(ya)(ya)(ya)電(dian)(dian)流(liu)峰值的(de)上(shang)限(xian),低(di)(di)壓(ya)(ya)(ya)電(dian)(dian)流(liu)超過過流(liu)保護將認(ren)為擊(ji)穿(chuan)
信息(xi)顯示(shi)區:顯示(shi)試(shi)驗過程中的試(shi)驗狀態和提示(shi)信息(xi)。
試(shi)驗操作區:選擇設置(zhi)、試(shi)驗、回零命令。
2、設置參數
在主(zhu)界(jie)面上,選中“設(she)(she)置”,然后(hou)按確(que)定后(hou)進入設(she)(she)置界(jie)面,如圖11:
按(an)左←,右(you)→時切換光標(biao)(biao)移動(dong)位置(zhi),按(an)上↑、下↓時更改光標(biao)(biao)位置(zhi)數據的值(zhi)。光標(biao)(biao)位置(zhi)和設置(zhi)的數值(zhi)全部(bu)可以自(zi)動(dong)循(xun)環,前且在使用時有默(mo)認的標(biao)(biao)準值(zhi)。如果所有的參數都(dou)設置(zhi)完(wan)成,按(an)取(qu)消退出設置(zhi)回到主界面開始狀態。
3、手動(dong)試驗
零(ling)(ling)位檢查—當選中“試驗(yan)”后(hou),按確定(ding)就(jiu)進入提(ti)示試驗(yan)狀態。如果調壓器不在零(ling)(ling)位,將(jiang)提(ti)示“試驗(yan)前請先回(hui)零(ling)(ling)”,退出試驗(yan)并且切換到回(hui)零(ling)(ling)命令。
試驗過程—回零確(que)認后,可以進(jin)行試驗。選中“試驗”后按確(que)定(ding),接(jie)觸器合(he)閘(zha),這時輸出電壓(ya)幾乎為0,如圖12:
按上↑,高壓(ya)(ya)電壓(ya)(ya)將不斷升壓(ya)(ya),松開(kai)就(jiu)停止升壓(ya)(ya),如果到上限就(jiu)提示滿量(liang)程;
按下↓,高(gao)壓電壓將不斷(duan)降壓,松開就(jiu)停止降壓,如果到(dao)下限(xian)就(jiu)提示已回(hui)零;
按(an)計時(shi)←,計時(shi)開(kai)始工作,到耐壓時(shi)間計時(shi)結束完成試驗;
按取消→,取消試驗過程;
在升壓(ya)(ya)過程中,如果高壓(ya)(ya)電(dian)(dian)(dian)(dian)流(liu)(liu)峰(feng)(feng)值超過“電(dian)(dian)(dian)(dian)流(liu)(liu)上限(xian)”值或低(di)(di)壓(ya)(ya)電(dian)(dian)(dian)(dian)流(liu)(liu)峰(feng)(feng)值超過“過流(liu)(liu)保護”值將認為被(bei)試(shi)(shi)品(pin)被(bei)擊穿,接(jie)觸(chu)(chu)器(qi)立刻分(fen)閘并顯(xian)示(shi)(shi)試(shi)(shi)驗(yan)結果,包括峰(feng)(feng)值電(dian)(dian)(dian)(dian)壓(ya)(ya)、峰(feng)(feng)值電(dian)(dian)(dian)(dian)流(liu)(liu)、低(di)(di)壓(ya)(ya)電(dian)(dian)(dian)(dian)流(liu)(liu)等,調壓(ya)(ya)器(qi)開始回零(ling),回零(ling)完成試(shi)(shi)驗(yan)結束(shu)(shu)。如果在耐壓(ya)(ya)過程中,高壓(ya)(ya)電(dian)(dian)(dian)(dian)流(liu)(liu)和低(di)(di)壓(ya)(ya)電(dian)(dian)(dian)(dian)流(liu)(liu)峰(feng)(feng)值沒有(you)超設置上限(xian)值,認為被(bei)試(shi)(shi)品(pin)未擊穿,結果顯(xian)示(shi)(shi)區就顯(xian)示(shi)(shi)耐壓(ya)(ya)電(dian)(dian)(dian)(dian)壓(ya)(ya)、高壓(ya)(ya)電(dian)(dian)(dian)(dian)流(liu)(liu)、低(di)(di)壓(ya)(ya)電(dian)(dian)(dian)(dian)流(liu)(liu)、絕緣電(dian)(dian)(dian)(dian)阻等,調壓(ya)(ya)器(qi)開始回零(ling),回零(ling)完成后接(jie)觸(chu)(chu)器(qi)分(fen)閘試(shi)(shi)驗(yan)結束(shu)(shu)。
4、自動試驗
自(zi)動試驗和手動試驗的試驗過程類似,首先(xian)也進(jin)行回零檢查(cha),確認后進(jin)入(ru)如(ru)下界面(mian),如(ru)圖13:
按(an)上方法切換到“開(kai)始”確定后(hou)進行試驗(yan),與(yu)手動試驗(yan)不同之(zhi)處就是升壓(ya)過程將自動升壓(ya)到“輸出電壓(ya)”值(zhi),然(ran)后(hou)進行計時(shi)。
升壓過程為(wei)逼近(jin)方(fang)式,首先升到到接近(jin)目標值,然(ran)后再進行微調,保證高(gao)壓電壓值幾乎為(wei)輸出電壓值。
5、功(gong)能(neng)選擇
按鍵盤上的“設置”就進(jin)入功能界面,如(ru)圖14:
進(jin)入功能界(jie)面后,可以(yi)選(xuan)擇“時(shi)鐘(zhong)設(she)置(zhi)”、“注意事(shi)項”等界(jie)面。
時鐘設置(zhi):設置(zhi)時鐘的時間,為打印報表提供時間依據。
注(zhu)意事(shi)項(xiang):為(wei)用戶提供一些操作規范(fan)和**注(zhu)意事(shi)項(xiang)。
6、打印
按鍵(jian)盤“打印”按鍵(jian)可(ke)以打印試驗(yan)果,在此不贅述。
七、產品維護(hu)
1、開箱驗收時,應檢查主控(kong)回(hui)路接線是否松動,調壓(ya)器(qi)電(dian)刷是否接觸良好(hao)。
2.、長(chang)期(qi)不用(yong)時,使用(yong)前應用(yong)500V兆(zhao)歐(ou)表測量(liang)絕緣電(dian)阻,其阻值不低于0.5MΩ。
3、電源電壓應符合控制箱(xiang)(臺)說(shuo)明書上的輸入電壓值要求。
4、本控(kong)制箱(xiang)(臺(tai))設有過電流(liu)保護,出廠已調整為額(e)定(ding)電流(liu)的50%。用于小負載(zai)時(shi),應根據(ju)被試(shi)品的額(e)定(ding)容量電流(liu)重新設定(ding);
5、使用完畢后,應關好(hao)控制箱(臺)門(men)蓋,以保持內部(bu)清潔。
八、注(zhu)意事項
1、按照您(nin)所進(jin)行(xing)的(de)(de)試(shi)驗接(jie)好工作(zuo)線路。試(shi)驗變(bian)壓器的(de)(de)外殼以及(ji)操作(zuo)系(xi)統的(de)(de)外殼必須可靠接(jie)地(di)。試(shi)驗變(bian)壓器的(de)(de)測量繞組的(de)(de)F端和外殼必須可靠接(jie)地(di)。
2、做串級(ji)(ji)試驗時,**級(ji)(ji)、第三級(ji)(ji)試驗變(bian)壓(ya)(ya)器(qi)的低壓(ya)(ya)繞(rao)(rao)組(zu)成(cheng)X端(duan),測量(liang)繞(rao)(rao)組(zu)的F端(duan)以及高壓(ya)(ya)繞(rao)(rao)組(zu)的X端(duan)(高壓(ya)(ya)端(duan))均接本級(ji)(ji)試驗變(bian)壓(ya)(ya)器(qi)具外(wai)殼。**級(ji)(ji)、第三級(ji)(ji)試驗變(bian)壓(ya)(ya)器(qi)的外(wai)殼必(bi)須(xu)通過(guo)絕緣支架接地(di)。
接通電源前(qian),控制箱(臺)的調(diao)壓(ya)器必須調(diao)到零位后方可接通電源,合閘,開(kai)始升壓(ya)。
3、從零開(kai)始勻速(su)旋轉調壓(ya)器手(shou)輪升(sheng)(sheng)(sheng)壓(ya)。升(sheng)(sheng)(sheng)壓(ya)方(fang)式有:快速(su)升(sheng)(sheng)(sheng)壓(ya)法(fa)(fa)(fa),即(ji)20s逐(zhu)級升(sheng)(sheng)(sheng)壓(ya)法(fa)(fa)(fa);慢速(su)升(sheng)(sheng)(sheng)壓(ya)法(fa)(fa)(fa),即(ji)60s逐(zhu)級升(sheng)(sheng)(sheng)壓(ya)法(fa)(fa)(fa);極(ji)慢速(su)升(sheng)(sheng)(sheng)壓(ya)法(fa)(fa)(fa)供選用。電(dian)壓(ya)從零開(kai)始按一定(ding)(ding)(ding)的(de)升(sheng)(sheng)(sheng)壓(ya)方(fang)式和速(su)度上升(sheng)(sheng)(sheng)到您所需(xu)的(de)額(e)定(ding)(ding)(ding)試(shi)(shi)驗電(dian)壓(ya)的(de)75%后(hou),再以每秒2%額(e)定(ding)(ding)(ding)試(shi)(shi)驗電(dian)壓(ya)的(de)速(su)度升(sheng)(sheng)(sheng)到您所需(xu)的(de)試(shi)(shi)驗電(dian)壓(ya),并密切注意測(ce)量(liang)儀表(biao)的(de)及(ji)被(bei)試(shi)(shi)品的(de)情況。升(sheng)(sheng)(sheng)壓(ya)過程(cheng)中(zhong)(zhong)或試(shi)(shi)驗過程(cheng)中(zhong)(zhong)如(ru)發現測(ce)量(liang)儀表(biao)的(de)指示及(ji)被(bei)試(shi)(shi)品情況異(yi)常,應立即(ji)降壓(ya),切斷電(dian)源,查(cha)明情況。
4、試驗(yan)完畢后,應在等(deng)調(diao)壓(ya)器返回至零位,然后切斷電源。
5、本產品不得超過額定參數使用。
6、使用本產(chan)品做高壓試(shi)(shi)驗(yan)時,除熟(shu)悉(xi)本說明書外,還(huan)必(bi)須嚴格執行(xing)國家有關標準和操(cao)作規程。可(ke)參照GB311.1 – 97《高壓輸變設(she)備的絕(jue)緣配合,高壓試(shi)(shi)驗(yan)技(ji)術》;《電氣設(she)備預(yu)防性試(shi)(shi)驗(yan)規程》等。
7、控制(zhi)箱(xiang)(臺)應與試驗變壓器配套使(shi)用,控制(zhi)箱(xiang)(臺)的使(shi)用方法,請(qing)詳細參閱控制(zhi)器的使(shi)用說明書。