一、WBNYZ-200絕(jue)緣(yuan)工具耐(nai)壓裝置(zhi)概述
絕(jue)(jue)緣(yuan)(yuan)靴(xue)和(he)絕(jue)(jue)緣(yuan)(yuan)手(shou)套(tao)是(shi)電(dian)(dian)力(li)系統操作和(he)檢修必(bi)備的(de)**防(fang)護用(yong)具,DL408《電(dian)(dian)業**工(gong)作規(gui)程(cheng)》規(gui)定了絕(jue)(jue)緣(yuan)(yuan)靴(xue)及絕(jue)(jue)緣(yuan)(yuan)手(shou)套(tao)等常用(yong)**工(gong)器具的(de)試(shi)驗(yan)方法和(he)周(zhou)期。絕(jue)(jue)緣(yuan)(yuan)靴(xue)及絕(jue)(jue)緣(yuan)(yuan)手(shou)套(tao)耐壓試(shi)驗(yan),周(zhou)期為(wei)半年,試(shi)驗(yan)過(guo)程(cheng)中不允許擊穿,同時絕(jue)(jue)緣(yuan)(yuan)靴(xue)泄漏電(dian)(dian)流不大于限定值(zhi)。
儀器采用多路高壓泄流測量(liang)**技(ji)術(shu)和(he)紅(hong)外數據通訊(xun)技(ji)術(shu),實現(xian)了**測量(liang)高壓泄漏(lou)電流的目的。通過本技(ji)術(shu)的應用,測試儀與(yu)高壓系統(tong)完全隔離,不僅可以**測量(liang)多路高壓泄漏(lou)電流,而(er)且確保了試驗人員的人身**。
為了提高工(gong)作效率,一(yi)次可以同(tong)時(shi)進行8只試(shi)(shi)(shi)品的(de)試(shi)(shi)(shi)驗(yan)(yan),為避免重復試(shi)(shi)(shi)驗(yan)(yan),采(cai)用(yong)高壓分斷(duan)**技術,試(shi)(shi)(shi)驗(yan)(yan)過程中可以將擊(ji)(ji)穿(chuan)的(de)試(shi)(shi)(shi)品脫(tuo)離高壓試(shi)(shi)(shi)驗(yan)(yan)系(xi)統,沒有擊(ji)(ji)穿(chuan)的(de)試(shi)(shi)(shi)品繼續試(shi)(shi)(shi)驗(yan)(yan)直到完(wan)成(cheng)試(shi)(shi)(shi)驗(yan)(yan)。
二、WBNYZ-200絕緣工具耐壓(ya)裝置(zhi)主要功(gong)能與技術參數
2.1主要功(gong)能
2.1.1同(tong)時進行8只(zhi)絕(jue)緣(yuan)靴(xue)或絕(jue)緣(yuan)手(shou)套(tao)的試驗,分別測(ce)量泄漏電流。
2.1.2采用大屏幕液晶(jing)全漢(han)字顯示(shi)(shi)(shi),顯示(shi)(shi)(shi)信息量大,一屏同(tong)時(shi)顯示(shi)(shi)(shi)8路高壓(ya)泄漏電流(liu)、試驗電壓(ya)、電流(liu)、計時(shi)時(shi)間等(deng)參(can)數。
2.1.3可測(ce)量試驗電(dian)壓、試驗變壓器一次電(dian)流(liu)等參數。
2.1.4采用紅外(wai)通訊**技術,使操作臺(tai)與高壓系(xi)統徹底隔離(li),確保試驗人員**。
2.1.5全自動(dong)(dong)(dong)進行耐壓試驗。試驗開(kai)(kai)始(shi)后(hou),儀器自動(dong)(dong)(dong)合(he)閘以國(guo)標(biao)要求升壓速度(du)自動(dong)(dong)(dong)升壓,升至預定(ding)電(dian)(dian)壓開(kai)(kai)始(shi)計(ji)時(shi)并(bing)保持試驗電(dian)(dian)壓,時(shi)間(jian)到自動(dong)(dong)(dong)降壓至零并(bing)斷電(dian)(dian),同時(shi)顯示各(ge)試品泄漏電(dian)(dian)流并(bing)自動(dong)(dong)(dong)保存試驗結果(guo)。
2.1.6具(ju)有專用(yong)接地容器,便于(yu)操作。
2.1.7每路試品均具備高壓分斷機構,當(dang)任意一(yi)路擊(ji)穿(chuan)時,該路試品將自動脫離高壓,不(bu)影響(xiang)試驗(yan)的(de)進行。
2.1.8具有過(guo)壓、過(guo)流保護功能。
2.1.9具(ju)有(you)高壓(ya)危險警示燈顯示。
2.1.10可保存60組試(shi)驗數據及結果,隨(sui)時查閱(yue)。
2.1.11實(shi)時(shi)日歷(li)時(shi)鐘功能。
2.2技術參數
額定輸出電(dian)壓:50kV
額定(ding)容量(liang): 5kVA
輸出(chu)電(dian)壓量程:50.0 kV(250V)
電壓測量誤差:<±(0.2%U+0.02%Umax),
其中U為(wei)示值(zhi),Umax為(wei)量程上限值(zhi)
輸入電流量程:25.0A
電(dian)流(liu)測(ce)量誤差:<±(0.2%I+0.02%Imax),
其中I為(wei)示值,Imax為(wei)量程上限(xian)值
泄(xie)漏電(dian)流量(liang)程(cheng):25.0mA
泄漏電流測(ce)量(liang)誤差:±(0.5%I+2個字),
其中I為示值(zhi)
泄(xie)漏電流分辨率:0.1 mA
數顯計時: 10~990 S
三、WBNYZ-200絕(jue)緣工具耐壓裝(zhuang)置設備組成
全自動絕緣靴手套(tao)耐壓(ya)泄(xie)露電流(liu)測試(shi)儀(本文(wen)中簡稱(cheng)測試(shi)儀)1臺
3.2 測控(kong)臺 (本文中簡稱高壓泄流測控(kong)儀(yi)) 1套
3.3 試驗變壓(ya)器(選(xuan)配件) 1套
3.4 絕(jue)緣支架(選配件) 1套
四、WBNYZ-200絕緣工具耐壓裝置面板(ban)布(bu)置
4.1儀器面板布置
液(ye)(ye)晶屏(ping)下(xia)(xia)兩個控(kong)制鍵(jian)(jian)“∧”“∨”鍵(jian)(jian)可(ke)(ke)調節液(ye)(ye)晶屏(ping)的對比(bi)度(du)。液(ye)(ye)晶屏(ping)右側的操作(zuo)鍵(jian)(jian)“∧”“∨”鍵(jian)(jian)及“<”“ > ”鍵(jian)(jian)可(ke)(ke)分別用來(lai)選擇(ze)菜單(dan)和增減選擇(ze)量,“確(que)認”鍵(jian)(jian)用來(lai)確(que)認所選項目、啟動(dong)(dong)等工(gong)作(zuo),“退出”鍵(jian)(jian)用來(lai)停止試驗、返回(hui)上**菜單(dan)。“急(ji)停”鍵(jian)(jian)用于(yu)特殊情況下(xia)(xia)緊急(ji)停止試驗,“升(sheng)壓”“降(jiang)壓”鍵(jian)(jian)用來(lai)手(shou)動(dong)(dong)調節升(sheng)壓、降(jiang)壓。
4.3試驗(yan)接線
測(ce)試(shi)(shi)儀電源輸入端子(zi)接(jie)交流(liu)(liu)220V電源,0 ~ 250V電源輸出(chu)接(jie)試(shi)(shi)驗變壓(ya)器一次輸入,測(ce)量(liang)輸入接(jie)試(shi)(shi)驗變壓(ya)器測(ce)量(liang)線圈;試(shi)(shi)驗變壓(ya)器高壓(ya)輸出(chu)接(jie)高壓(ya)泄流(liu)(liu)測(ce)控儀高壓(ya)輸入;測(ce)試(shi)(shi)儀、試(shi)(shi)驗變壓(ya)器、高壓(ya)泄流(liu)(liu)測(ce)控儀接(jie)地點均接(jie)地。
注意(yi):紅外數據通訊(xun)端(duan)口(kou)之間(jian)(jian)夾角不大(da)于30度,兩(liang)個端(duan)口(kou)間(jian)(jian)距離(li)不超(chao)過(guo)6m。
五、WBNYZ-200絕緣工具耐壓裝置操作說(shuo)明
5.1開機
打開(kai)測控臺電源開(kai)關。接通(tong)全自動絕緣靴(xue)手套耐(nai)壓泄(xie)露電流測試儀220V試驗(yan)電源,打開(kai)測試儀左下腳電源開(kai)關,液晶屏(ping)顯示(shi)開(kai)機畫面,警(jing)示(shi)燈綠燈亮。
屏(ping)幕(mu)右上角顯示紅外(wai)(wai)通(tong)訊(xun)(xun)(xun)狀態,以動(dong)畫(hua)顯示,如看不(bu)到動(dong)畫(hua)顯示,請檢查(cha)高壓泄流測控(kong)儀是(shi)否開(kai)機(ji),紅外(wai)(wai)數(shu)據(ju)通(tong)訊(xun)(xun)(xun)端口是(shi)否對(dui)正(zheng)(zheng)。屏(ping)幕(mu)左下方顯示電池電量(liang)模(mo)擬(ni)條,滿(man)格時(shi)表示電池已充滿(man)。建議用戶(hu)在(zai)剩余一格時(shi)進行充電。電池電量(liang)信息(xi)由(you)紅外(wai)(wai)數(shu)據(ju)通(tong)訊(xun)(xun)(xun)傳遞,在(zai)紅外(wai)(wai)通(tong)訊(xun)(xun)(xun)非正(zheng)(zheng)常(chang)狀態下的(de)顯示不(bu)是(shi)電池電量(liang)實(shi)際信息(xi),請在(zai)紅外(wai)(wai)通(tong)訊(xun)(xun)(xun)正(zheng)(zheng)常(chang)條件下檢查(cha)電池電量(liang)信息(xi)。
開機后(hou),按液晶屏右側控(kong)制鍵盤任(ren)意鍵即可(ke)進入主菜單。
5.2試驗(yan)操作(zuo)
5.2.1主(zhu)菜單的選擇
按“∧”“∨”鍵可選擇主菜單上的選項(試(shi)品(pin)參(can)數設定(ding)、查詢試(shi)驗(yan)結果、全自(zi)動耐壓試(shi)驗(yan)、系統設定(ding)、**試(shi)驗(yan)記錄等),按“確認”鍵進入所(suo)選項目子菜單。
5.2.2試品參數設定
進入主(zhu)菜(cai)單,選(xuan)(xuan)擇“試品參(can)數(shu)(shu)設定”項,按“確(que)(que)認(ren)(ren)”鍵(jian)(jian)進入“試品參(can)數(shu)(shu)設定”子(zi)菜(cai)單。顯(xian)示序(xu)號為當前測試儀內所存(cun)儲的(de)*后(hou)一組試品參(can)數(shu)(shu)。要進行新一組絕緣靴(xue)、手套的(de)試驗須(xu)新建一條記錄,選(xuan)(xuan)定“新建”菜(cai)單按確(que)(que)認(ren)(ren)鍵(jian)(jian),序(xu)號加一,分別進行試品編號、試驗電壓等項目的(de)設定。按“∧”“∨”鍵(jian)(jian)選(xuan)(xuan)擇項目,“<”“ > ”鍵(jian)(jian)選(xuan)(xuan)擇參(can)數(shu)(shu)。然后(hou)按“確(que)(que)認(ren)(ren)”鍵(jian)(jian)保(bao)存(cun)并返(fan)回(hui)。
“試品(pin)編號”為(wei)一組試品(pin)的(de)代(dai)號,可設置(zhi)為(wei)6位(wei)數字;“試驗(yan)(yan)電壓(ya)(ya)(ya)(ya)”為(wei)試驗(yan)(yan)變壓(ya)(ya)(ya)(ya)器(qi)高壓(ya)(ya)(ya)(ya)輸出(chu)電壓(ya)(ya)(ya)(ya),根據(ju)需要進行(xing)設定(ding)。例(li)如,要做1組(8只)絕緣手套的(de)耐(nai)壓(ya)(ya)(ya)(ya)試驗(yan)(yan),需要施加(jia)8kV電壓(ya)(ya)(ya)(ya),“試驗(yan)(yan)電壓(ya)(ya)(ya)(ya)”選(xuan)擇“8kV”,開始耐(nai)壓(ya)(ya)(ya)(ya)試驗(yan)(yan)后(hou)測試儀將(jiang)自動升壓(ya)(ya)(ya)(ya)至試驗(yan)(yan)變壓(ya)(ya)(ya)(ya)器(qi)高壓(ya)(ya)(ya)(ya)輸出(chu)8 kV。
儀器系統配置有絕(jue)緣(yuan)桿耐壓(ya)試驗(yan)功能時(shi),試品(pin)參數設(she)定菜單(dan)中增加了“試品(pin)類型”設(she)定項(xiang)。進行絕(jue)緣(yuan)桿耐壓(ya)試驗(yan)時(shi),設(she)為“絕(jue)緣(yuan)桿類”;進行絕(jue)緣(yuan)手(shou)套(tao)或絕(jue)緣(yuan)靴耐壓(ya)試驗(yan)時(shi),設(she)為“絕(jue)緣(yuan)靴手(shou)套(tao)”。
說(shuo)明:國家標準(zhun)GB10211-2009\GB17622-2008中(zhong)規定了電絕緣鞋和絕緣手套的電性能要求,見附(fu)表。
5.2.3查詢測試(shi)結果
進入(ru)主菜單(dan),選擇“查(cha)(cha)(cha)詢試(shi)(shi)(shi)驗(yan)結(jie)果”項,按“確認”鍵(jian)進入(ru)查(cha)(cha)(cha)詢試(shi)(shi)(shi)驗(yan)結(jie)果子菜單(dan)。可查(cha)(cha)(cha)閱任一序號下(xia)試(shi)(shi)(shi)品參數、全自動耐壓(ya)試(shi)(shi)(shi)驗(yan)記錄及(ji)試(shi)(shi)(shi)驗(yan)結(jie)果以(yi)及(ji)試(shi)(shi)(shi)驗(yan)日(ri)期(qi)等(deng)項目,按確認鍵(jian)返回主菜單(dan)。
5.2.4全自(zi)動耐壓試驗
設(she)(she)定好試品參數進行試驗前,應首先進入“系統設(she)(she)定”菜單(dan)進行“測量線圈(quan)電壓(ya)設(she)(she)定”,根(gen)據所選試驗變壓(ya)器測量線圈(quan)電壓(ya)設(she)(she)定。
5.2.4.1絕(jue)緣(yuan)靴手套(tao)耐壓(ya)試(shi)驗
試驗接線示意(yi)圖見附圖一(yi)。
進入(ru)“主菜(cai)單”,選擇“全(quan)自動(dong)耐壓(ya)試(shi)(shi)驗(yan)”項,按(an)“確認(ren)”鍵進入(ru)耐壓(ya)試(shi)(shi)驗(yan)子(zi)菜(cai)單。設(she)定各試(shi)(shi)驗(yan)參(can)數值(zhi),“試(shi)(shi)驗(yan)時(shi)間”按(an)國標要求設(she)定為“60S”;“分(fen)斷電流”設(she)置(zhi):絕緣(yuan)靴耐壓(ya)試(shi)(shi)驗(yan)設(she)為12mA,絕緣(yuan)手套(tao)耐壓(ya)試(shi)(shi)驗(yan)設(she)為10mA。設(she)定好參(can)數后,按(an)“確認(ren)”鍵保存并(bing)進入(ru)試(shi)(shi)驗(yan)狀態。警示(shi)燈綠燈滅紅(hong)燈亮,檢查(cha)儀器右上角(jiao)顯(xian)示(shi)的(de)紅(hong)外通訊(xun)狀態是否正常(chang),若(ruo)看不到動(dong)畫顯(xian)示(shi)請檢查(cha)紅(hong)外數據通訊(xun)端口是否對正。
閉(bi)合測(ce)試(shi)(shi)(shi)(shi)儀(yi)面(mian)板試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)電(dian)源開(kai)關,按“確認”鍵開(kai)始(shi)(shi)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan),接觸器吸合,測(ce)試(shi)(shi)(shi)(shi)儀(yi)自(zi)動(dong)開(kai)始(shi)(shi)以國(guo)標要求(qiu)速(su)度升壓(ya)(ya),升至(zhi)設(she)定電(dian)壓(ya)(ya)值后保持電(dian)壓(ya)(ya)并(bing)開(kai)始(shi)(shi)計時(shi)(shi)。試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)過(guo)(guo)(guo)程(cheng)(cheng)中高(gao)壓(ya)(ya)泄流測(ce)控儀(yi)通過(guo)(guo)(guo)紅外數據(ju)通訊端口將8路(lu)試(shi)(shi)(shi)(shi)品(pin)泄漏(lou)電(dian)流數據(ju)實時(shi)(shi)傳遞至(zhi)測(ce)試(shi)(shi)(shi)(shi)儀(yi)并(bing)顯示(shi)。計時(shi)(shi)時(shi)(shi)間(jian)到,儀(yi)器自(zi)動(dong)降壓(ya)(ya)并(bing)保存試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)數據(ju)。試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)過(guo)(guo)(guo)程(cheng)(cheng)中如(ru)某一(yi)路(lu)試(shi)(shi)(shi)(shi)品(pin)擊穿(chuan)或泄流值超過(guo)(guo)(guo)設(she)定值時(shi)(shi),該路(lu)高(gao)壓(ya)(ya)分斷機構動(dong)作(zuo),試(shi)(shi)(shi)(shi)品(pin)自(zi)動(dong)脫(tuo)離(li)高(gao)壓(ya)(ya),其余試(shi)(shi)(shi)(shi)品(pin)繼(ji)續試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan),同時(shi)(shi)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)畫面(mian)相應(ying)位置顯示(shi)試(shi)(shi)(shi)(shi)品(pin)脫(tuo)離(li)時(shi)(shi)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)電(dian)壓(ya)(ya)。
注意:試(shi)驗完成后,為(wei)保證**請在不銹鋼導鏈(lian)或彈簧腔上(shang)端的掛鉤位置將每個試(shi)品的高壓接入端分別放電。
5.2.4.2絕緣桿(gan)耐壓試驗(yan)(本(ben)項功能(neng)為選配功能(neng))
試(shi)驗接線示意(yi)圖見附圖二。
進(jin)行(xing)本(ben)項(xiang)(xiang)試驗(yan)前(qian),需確定儀器(qi)系統配置有絕(jue)緣(yuan)桿(gan)耐壓(ya)(ya)(ya)試驗(yan)功能,并配套應(ying)用絕(jue)緣(yuan)桿(gan)耐壓(ya)(ya)(ya)測試架試驗(yan),否則不能進(jin)行(xing)本(ben)項(xiang)(xiang)試驗(yan)。試品(pin)參數設(she)(she)定項(xiang)(xiang)中,“試品(pin)類別”選擇“絕(jue)緣(yuan)桿(gan)類”。“試驗(yan)電壓(ya)(ya)(ya)”根據試品(pin)實際需要(yao)設(she)(she)定。
進入(ru)(ru)“主(zhu)菜單”,選擇(ze)“全自動耐壓(ya)試(shi)(shi)驗(yan)(yan)(yan)”項,按(an)“確認(ren)”鍵進入(ru)(ru)耐壓(ya)試(shi)(shi)驗(yan)(yan)(yan)子菜單。設(she)(she)定各(ge)試(shi)(shi)驗(yan)(yan)(yan)參數(shu)值,“試(shi)(shi)驗(yan)(yan)(yan)時間”按(an)國(guo)標要(yao)求設(she)(she)定為“60S”;“測(ce)量變(bian)比”按(an)配(pei)套使用(yong)的交流升壓(ya)器實際高壓(ya)輸(shu)出(chu)比測(ce)量變(bian)比進行設(she)(she)定。設(she)(she)定好參數(shu)后(hou),按(an)“確認(ren)”鍵保存并進入(ru)(ru)試(shi)(shi)驗(yan)(yan)(yan)狀態。警(jing)示燈綠燈滅(mie)紅燈亮。
閉合測(ce)(ce)試儀面板試驗(yan)電源(yuan)開關,按“確認”鍵開始(shi)試驗(yan),接觸(chu)器吸合,測(ce)(ce)試儀自動(dong)升(sheng)壓(ya),升(sheng)至設定電壓(ya)值后保持電壓(ya)并開始(shi)計時。計時時間到,儀器自動(dong)降壓(ya)并保存試驗(yan)數據。
本套設備可同時進行(xing)8根絕緣(yuan)桿(gan)耐壓試(shi)驗,試(shi)驗過程(cheng)中(zhong),若其中(zhong)一根發生閃絡或放電等(deng),應立(li)即按“急停”鍵停止試(shi)驗。將耐壓測試(shi)架放電后,剔除異常的(de)絕緣(yuan)桿(gan),對其余的(de)繼續重新進行(xing)試(shi)驗。
5.2.5系統設定
進入主(zhu)菜單,選(xuan)擇“系統(tong)設(she)定”項(xiang),按(an)“確認”鍵進入系統(tong)設(she)定程(cheng)序。使用“∧”、“∨”鍵選(xuan)擇設(she)定項(xiang),根據(ju)屏幕提示(shi)分別進行高壓分斷自檢、時間設(she)定、系統(tong)校準、系統(tong)校驗、測量(liang)線圈(quan)設(she)定等項(xiang)目的設(she)定。
5.2.5.1高壓(ya)分(fen)斷自檢
選擇(ze)“高壓分斷(duan)(duan)自(zi)檢(jian)”項,按確認鍵進入高壓分斷(duan)(duan)自(zi)檢(jian)程序開始自(zi)檢(jian),8路分斷(duan)(duan)機構依次斷(duan)(duan)開。
5.2.5.2時間設定
進(jin)入“時(shi)間(jian)(jian)設定(ding)”子菜(cai)單,根據屏幕提示,使用“<”、“>”鍵(jian)(jian)選擇修改的時(shi)間(jian)(jian)參數,使用“∧”、“∨”鍵(jian)(jian)進(jin)行時(shi)間(jian)(jian)參數的加減。確(que)定(ding)當前年、月、日(ri)及時(shi)間(jian)(jian)。設定(ding)完成(cheng)按“確(que)認”鍵(jian)(jian)保存并返(fan)回(hui)系統設定(ding)菜(cai)單。
5.2.5.3系統校準(zhun)
儀器(qi)采(cai)用高智能(neng)化測量方式,具有軟件(jian)自動校準功能(neng),擯棄了采(cai)用電位(wei)器(qi)調校的(de)方式,不(bu)會(hui)產生(sheng)因電位(wei)器(qi)老化或振動阻值改變降低測量精度,可保(bao)證(zheng)儀器(qi)的(de)長期穩定。
注(zhu)意(yi):儀器出廠前進(jin)行了嚴格的校準(zhun)和老化,用戶不(bu)具備校準(zhun)條件(jian),請勿進(jin)入(ru)系統校準(zhun)程序。
5.2.5.4系統校驗
本項功能(neng)專為儀器(qi)檢(jian)(jian)定(ding)設(she)置,應用單相標準電源和(he)單相校驗(yan)儀進(jin)行檢(jian)(jian)定(ding)。選(xuan)擇“系(xi)(xi)統檢(jian)(jian)驗(yan)”項,按確認鍵(jian)進(jin)入系(xi)(xi)統校驗(yan)程序。接線如(ru)圖3,需(xu)打開儀器(qi)底(di)部(bu)固定(ding)螺栓(shuan)將(jiang)儀器(qi)拉出外包箱進(jin)行校驗(yan)接線。
泄(xie)(xie)漏電(dian)流的校驗需將測(ce)(ce)試(shi)儀(yi)主機和(he)高(gao)壓(ya)泄(xie)(xie)漏電(dian)流測(ce)(ce)控儀(yi)聯機測(ce)(ce)試(shi),通過(guo)紅外信號傳遞泄(xie)(xie)漏電(dian)流測(ce)(ce)試(shi)數據。
5.2.5.5測(ce)量(liang)線圈電壓設(she)定(ding)
選(xuan)擇“測(ce)量線(xian)(xian)圈(quan)(quan)電壓(ya)設定(ding)(ding)”項,按確認(ren)鍵(jian)進入測(ce)量線(xian)(xian)圈(quan)(quan)電壓(ya)設定(ding)(ding)程序,按“<”、“>”鍵(jian)選(xuan)擇線(xian)(xian)圈(quan)(quan)電壓(ya),可選(xuan)擇100V、200V、220V、250V,按照配(pei)套(tao)交(jiao)流(liu)升壓(ya)器測(ce)量線(xian)(xian)圈(quan)(quan)電壓(ya)設定(ding)(ding)。
如(ru)用戶自(zi)行配置的試(shi)(shi)驗變(bian)壓(ya)器,必須保證試(shi)(shi)驗變(bian)高壓(ya)輸出對測(ce)量(liang)線圈電壓(ya)比誤(wu)差(cha)不低于3%。
5.2.5.6 系統參數設定
通(tong)過本項(xiang)參數(shu)的設置(zhi),為(wei)儀器(qi)配(pei)置(zhi)絕緣(yuan)桿耐壓試(shi)驗(yan)功能。按(an)“確認”鍵(jian)更改參數(shu),按(an)“退出”鍵(jian)返回上**菜單。
“絕(jue)緣桿(gan)試驗(yan)”選擇為“有(you)”,軟件將配置有(you)絕(jue)緣桿(gan)耐(nai)壓(ya)試驗(yan)功能(neng),反之則無。
說明:本項參數為系(xi)統參數,設置(zhi)完成需(xu)**測試結果方可生效。請在設置(zhi)本參數前,將儀器內存儲(chu)的(de)數據(ju)轉存到數據(ju)卡上傳至PC機,進行妥善保管(guan)。
5.2.6**試驗記錄
進入主菜單,選擇(ze)“**試驗記錄”項,按“確認(ren)”鍵屏幕將出(chu)現“確認(ren)?”提(ti)示,此時若(ruo)再次按下確認(ren)鍵,將**所有保存的試驗記錄。
六、裝箱清單(dan)
全自動(dong)絕緣(yuan)靴手(shou)套耐壓試驗裝置裝箱單:
名稱
|
數量
|
主機
|
1臺
|
絕緣靴(xue)專用耐壓(ya)測試(shi)桶
|
8只
|
絕緣手套專用(yong)耐壓測試桶(tong)
|
8只(zhi)
|
鋰電池(chi)專(zhuan)用充電器
|
1只
|
測試線
|
1條(tiao)
|
電(dian)源線
|
1根
|
接地(di)線
|
1根
|
升(sheng)流器專用(yong)接地線
|
1條
|
接(jie)地桿專用接(jie)地線
|
1條
|
備用保險管3A
|
6只
|
鋼珠
|
1箱
|
產(chan)品說(shuo)明書(shu)
|
1份
|
出廠檢(jian)測報告
|
1份
|
高壓泄流測控臺裝箱(xiang)單:
名稱
|
數量
|
測控臺(tai)主機
|
1臺
|
分斷(duan)機構固(gu)定桿
|
2套
|
分斷機構(gou)支撐(cheng)臂
|
2套
|
高壓導線
|
9條
|
加(jia)強橫板(ban)
|
1條
|
金屬接地桿
|
2條(tiao)
|
立柱
|
2條
|
底腳
|
2只
|
內六角(jiao)扳(ban)手(shou)
|
1只
|
備用固定(ding)旋鈕
|
3只
|
接地桿
|
1條
|
接地(di)桿支(zhi)撐臂
|
2只
|
備用分斷機構動接(jie)點
|
1只
|
備用(yong)螺(luo)絲(si)
|
6條
|
備用插頭
|
1只
|
7.**保護措施
本套設(she)(she)備(bei)對(dui)試品及試驗(yan)設(she)(she)備(bei)做了相應保護措施,儀器設(she)(she)有
過(guo)流(liu)(liu)(liu)及放(fang)(fang)電保(bao)護,當出現過(guo)流(liu)(liu)(liu)或(huo)放(fang)(fang)電情(qing)況時儀器會提示(shi)“過(guo)流(liu)(liu)(liu)”。或(huo)“放(fang)(fang)電”。
測試(shi)(shi)儀面板配置有“急停(ting)”按鈕(niu),有意(yi)外情況時可(ke)緊急停(ting)止試(shi)(shi)驗(yan),以(yi)保護試(shi)(shi)品及試(shi)(shi)驗(yan)人員**。
8.售后服(fu)務
8.1.本產品自售出之(zhi)日(ri)起,一年(nian)之(zhi)內免(mian)費(fei)維修(xiu)。若非儀器(qi)正(zheng)常使用情況損壞,酌收成本費(fei)。
8.2.保修期外,終身維修,只收成本(ben)費。
附(fu)圖一、絕(jue)緣靴手套(tao)耐壓試驗接線示意(yi)圖
附圖二(er)、絕緣桿雙段耐壓試驗接線示意圖
附圖三、驗電器(qi)及絕緣桿單(dan)段耐(nai)壓試驗接線示(shi)意(yi)圖
附表1 電絕緣皮鞋(xie)和電絕緣布(bu)面膠鞋(xie)的電性(xing)能要求(qiu)(GB12011-2009)
項(xiang)目名稱
|
出廠(chang)檢驗
|
預防性檢驗
|
皮鞋
|
布(bu)面膠鞋
|
皮鞋
|
布(bu)面膠鞋(xie)
|
測試電壓(ya)(工頻(pin))/kV
|
6
|
5
|
15
|
5
|
3.5
|
12
|
泄漏電流(liu)/mA
|
≤1.8
|
≤1.5
|
≤4.5
|
≤1.5
|
≤1.1
|
≤3.6
|
測(ce)試時間/min
|
1
|
附表2 電絕(jue)緣全橡(xiang)膠膠鞋和電絕(jue)緣全聚(ju)合材料鞋的(de)電性能(neng)要求(GB12011-2009)
項目名稱
|
出(chu)廠(chang)檢驗(yan)
|
預防性檢驗
|
測試電壓(ya)(工頻)/kV
|
6
|
10
|
15
|
20
|
30
|
4.5
|
8
|
12
|
15
|
25
|
泄漏電(dian)流/mA
|
≤2.4
|
≤4
|
≤6
|
≤8
|
≤10
|
≤1.8
|
≤3.2
|
≤4.8
|
≤6
|
≤10
|
測試時間/min
|
1
|
附(fu)表3 絕緣(yuan)手套(tao)電氣絕緣(yuan)性能要求(qiu)(GB17622-2008)
適用電壓(ya)等級
AC/V
|
交流(liu)試驗(yan)
|
直流試(shi)驗
|
驗(yan)證試(shi)驗(yan)電(dian)壓/kV
|
*低耐受電壓(ya)/kV
|
驗證電壓(ya)下泄漏電流/mA
|
驗(yan)證試驗(yan)電(dian)壓(ya)/kV
|
*低耐(nai)受電(dian)壓/kV
|
手套(tao)長度/mm
|
280
|
360
|
410
|
≥460
|
380
|
5
|
10
|
12
|
14
|
16
|
18
|
10
|
20
|
3000
|
10
|
20
|
N/a
|
16
|
18
|
20
|
20
|
40
|
10000
|
20
|
30
|
N/a
|
18
|
20
|
22
|
30
|
60
|
20000
|
30
|
40
|
N/a
|
20
|
22
|
24
|
40
|
70
|
35000
|
40
|
50
|
N/a
|
N/a
|
24
|
26
|
60
|
90
|
a本表中(zhong)所規(gui)定的泄漏電(dian)流值僅適用于絕緣手套(tao),對復合絕緣手套(tao)另(ling)有規(gui)定。
|
注(zhu)1:N/a表示(shi)無適用值。
注2:在正常使(shi)用時(shi),其泄漏電(dian)流(liu)值會(hui)比(bi)試(shi)(shi)驗值要小,因(yin)為試(shi)(shi)驗時(shi)試(shi)(shi)品與水的接(jie)觸(chu)面(mian)積比(bi)在進行(xing)帶電(dian)作業時(shi)的接(jie)觸(chu)面(mian)積大,并且驗證試(shi)(shi)驗電(dian)壓(ya)比(bi)*大使(shi)用電(dian)壓(ya)要高。
注(zhu)3:對于預防性試驗(手套沒有經過預(yu)濕處(chu)理),泄漏電流(liu)規(gui)定值(zhi)應(ying)(ying)相應(ying)(ying)降低2mA。
|
附(fu)表4 絕緣桿試(shi)驗項目、周期和要(yao)求
項目(mu)
|
周期
|
要求
|
說(shuo)明
|
工(gong)頻(pin)耐壓(ya)試(shi)驗
|
1年(nian)
|
額定電壓/KV
|
試(shi)驗(yan)長度(du)/m
|
工頻耐壓/KV
|
|
1min
|
5min
|
10
|
0.7
|
45
|
--
|
35
|
0.9
|
95
|
--
|
63
|
1.0
|
175
|
--
|
110
|
1.3
|
220
|
--
|
220
|
2.1
|
440
|
--
|
330
|
3.2
|
--
|
380
|
500
|
4.1
|
--
|
580
|
注:當(dang)變壓(ya)器的輸出電壓(ya)值(zhi)達不(bu)到試驗電壓(ya)值(zhi)時,可分(fen)段(duan)進行(xing)試驗,*多分(fen)四(si)段(duan),分(fen)段(duan)試驗電壓(ya)值(zhi)
U =1.2×u總/4(u總為整體試驗電壓值)。
|